959 resultados para CMF, molecular cloud, extraction algorithm


Relevância:

30.00% 30.00%

Publicador:

Resumo:

High performance liquid chromatography (HPLC) is the reference method for measuring concentrations of antimicrobials in blood. This technique requires careful sample preparation. Protocols using organic solvents and/or solid extraction phases are time consuming and entail several manipulations, which can lead to partial loss of the determined compound and increased analytical variability. Moreover, to obtain sufficient material for analysis, at least 1 ml of plasma is required. This constraint makes it difficult to determine drug levels when blood sample volumes are limited. However, drugs with low plasma-protein binding can be reliably extracted from plasma by ultra-filtration with a minimal loss due to the protein-bound fraction. This study validated a single-step ultra-filtration method for extracting fluconazole (FLC), a first-line antifungal agent with a weak plasma-protein binding, from plasma to determine its concentration by HPLC. Spiked FLC standards and unknowns were prepared in human and rat plasma. Samples (240 microl) were transferred into disposable microtube filtration units containing cellulose or polysulfone filters with a 5 kDa cut-off. After centrifugation for 60 min at 15000g, FLC concentrations were measured by direct injection of the filtrate into the HPLC. Using cellulose filters, low molecular weight proteins were eluted early in the chromatogram and well separated from FLC that eluted at 8.40 min as a sharp single peak. In contrast, with polysulfone filters several additional peaks interfering with the FLC peak were observed. Moreover, the FLC recovery using cellulose filters compared to polysulfone filters was higher and had a better reproducibility. Cellulose filters were therefore used for the subsequent validation procedure. The quantification limit was 0.195 mgl(-1). Standard curves with a quadratic regression coefficient > or = 0.9999 were obtained in the concentration range of 0.195-100 mgl(-1). The inter and intra-run accuracies and precisions over the clinically relevant concentration range, 1.875-60 mgl(-1), fell well within the +/-15% variation recommended by the current guidelines for the validation of analytical methods. Furthermore, no analytical interference was observed with commonly used antibiotics, antifungals, antivirals and immunosuppressive agents. Ultra-filtration of plasma with cellulose filters permits the extraction of FLC from small volumes (240 microl). The determination of FLC concentrations by HPLC after this single-step procedure is selective, precise and accurate.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

BACKGROUND: Surveillance of multiple congenital anomalies is considered to be more sensitive for the detection of new teratogens than surveillance of all or isolated congenital anomalies. Current literature proposes the manual review of all cases for classification into isolated or multiple congenital anomalies. METHODS: Multiple anomalies were defined as two or more major congenital anomalies, excluding sequences and syndromes. A computer algorithm for classification of major congenital anomaly cases in the EUROCAT database according to International Classification of Diseases (ICD)v10 codes was programmed, further developed, and implemented for 1 year's data (2004) from 25 registries. The group of cases classified with potential multiple congenital anomalies were manually reviewed by three geneticists to reach a final agreement of classification as "multiple congenital anomaly" cases. RESULTS: A total of 17,733 cases with major congenital anomalies were reported giving an overall prevalence of major congenital anomalies at 2.17%. The computer algorithm classified 10.5% of all cases as "potentially multiple congenital anomalies". After manual review of these cases, 7% were agreed to have true multiple congenital anomalies. Furthermore, the algorithm classified 15% of all cases as having chromosomal anomalies, 2% as monogenic syndromes, and 76% as isolated congenital anomalies. The proportion of multiple anomalies varies by congenital anomaly subgroup with up to 35% of cases with bilateral renal agenesis. CONCLUSIONS: The implementation of the EUROCAT computer algorithm is a feasible, efficient, and transparent way to improve classification of congenital anomalies for surveillance and research.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

L'algorisme de McLachlan per a l'alineament de dos conjunts de coordenades atòmiques és interpretat sota l'òptica de l'Anàlisi Multivariant, que posa de manifest que el plantejament d'aquest problema és equivalent al de l'anàlisi de Procrustes i que la solució proposada per Kabsch és anàloga a la de Sibson, desenvolupada independentment

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The objective of the present work was to characterize banana accessions from the Germplasm Bank at Embrapa Mandioca e Fruticultura Tropical (Brazil), using agronomical, physical and physicochemical characteristics of fruit and simple sequence repeats (SSR) markers. Twenty-six accessions were analyzed, in which high genetic variability was found, especially for the agronomical characters number of fruit and weight of bunch. Accessions with high contents of carotenoids (diploid 'Jaran'), polyphenols (triploid 'Caipira' and tetraploid 'Teparod') and vitamin C (diploid 'Tuugia' and an unknown triploid AAA) in the fruit were identified. Thirteen microsatellite primers revealed an average of 7.23 alleles, which showed high variability. A dendrogram was prepared using the Gower algorithm for the distance matrices obtained from the agronomical, physical and physicolchemical analysis of fruit and SSR markers. Adopting the average genetic divergence as the cut-off point, three clusters were found: G1, formed by the diploids 'Jaran', 028003-01 and M-48; G2, by the diploids 'Malbut' and 'Ido 110'; and G3, by 21 tri-and tetraploid accessions, including one diploid, 'Tuugia'. The triploids with the B genome 'Thap Maeo', 'Walha', 'Pacha Nadan' and 'Champa Madras' were grouped in G2. Results from this work can be used for breeding hybrids with good agronomical traits and fruit quality.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Tässä diplomityössä tutkitaan tekniikoita, joillavesileima lisätään spektrikuvaan, ja menetelmiä, joilla vesileimat tunnistetaanja havaitaan spektrikuvista. PCA (Principal Component Analysis) -algoritmia käyttäen alkuperäisten kuvien spektriulottuvuutta vähennettiin. Vesileiman lisääminen spektrikuvaan suoritettiin muunnosavaruudessa. Ehdotetun mallin mukaisesti muunnosavaruuden komponentti korvattiin vesileiman ja toisen muunnosavaruuden komponentin lineaarikombinaatiolla. Lisäyksessä käytettävää parametrijoukkoa tutkittiin. Vesileimattujen kuvien laatu mitattiin ja analysoitiin. Suositukset vesileiman lisäykseen esitettiin. Useita menetelmiä käytettiin vesileimojen tunnistamiseen ja tunnistamisen tulokset analysoitiin. Vesileimojen kyky sietää erilaisia hyökkäyksiä tarkistettiin. Diplomityössä suoritettiin joukko havaitsemis-kokeita ottamalla huomioon vesileiman lisäyksessä käytetyt parametrit. ICA (Independent Component Analysis) -menetelmää pidetään yhtenä mahdollisena vaihtoehtona vesileiman havaitsemisessa.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

A simple non-targeted differential HPLC-APCI/MS approach has been developed in order to survey metabolome modifications that occur in the leaves of Arabidopsis thaliana following wound-induced stress. The wound-induced accumulation of metabolites, particularly oxylipins, was evaluated by HPLC-MS analysis of crude leaf extracts. A generic, rapid and reproducible pressure liquid extraction procedure was developed for the analysis of restricted leaf samples without the need for specific sample preparation. The presence of various oxylipins was determined by head-to-head comparison of the HPLC-MS data, filtered with a component detection algorithm, and automatically compared with the aid of software searching for small differences in similar HPLC-MS profiles. Repeatability was verified in several specimens belonging to different series. Wound-inducible jasmonates were efficiently highlighted by this non-targeted approach without the need for complex sample preparation as is the case for the 'oxylipin signature' procedure based on GC-MS. Furthermore this HPLC-MS screening technique allowed the isolation of induced compounds for further characterisation by capillary-scale NMR (CapNMR) after HPLC scale-up. In this paper, the screening method is described and applied to illustrate its potential for monitoring polar and non-polar stress-induced constituents as well as its use in combination with CapNMR for the structural assignment of wound-induced compounds of interest

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Due to the low genetic variability reported in the commercial plantations of papaya (Carica papaya L.), the objective of this study was analyze the genetic diversity of 32 genotypes including cultivars, landraces, inbred lines, and improved germplasm using the AFLP technique (Amplified Fragment Length Polymorphism). The genetic distance matrix was obtained using the Nei and Li genetic distance and clustering was performed using the unweighted pair-method with arithmetic mean (UPGMA). Using 11 combinations of EcoRI/MseI primers, 383 polymorphic bands were obtained. On average, 34.8 polymorphic bands were obtained per primer combination. Five clusters were formed. The traditional cultivar 'Sunrise' and the inbred line CMF-L30-08 were the closest genotypes, and the improved germplasm (CMF041) and landrace (CMF233) the most distant. The main papaya cultivars commercially grown in Brazil, as well as four inbred lines and three improved germplasm, were clustered together, however, were not grouped in the same branch. The genetic distance between the Sunrise and Golden cultivars was 0.329, and even arising from mutation and selection within the Sunrise variety, the Golden stores considerable genetic variability. Additional variability was observed in the inbred lines derived from papaya breeding program at Embrapa Cassava and Fruits.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

When a bloodstream infection (BSI) is suspected, most of the laboratory results-biochemical and haematologic-are available within the first hours after hospital admission of the patient. This is not the case for diagnostic microbiology, which generally takes a longer time because blood culture, which is to date the reference standard for the documentation of the BSI microbial agents, relies on bacterial or fungal growth. The microbial diagnosis of BSI directly from blood has been proposed to speed the determination of the etiological agent but was limited by the very low number of circulating microbes during these paucibacterial infections. Thanks to recent advances in molecular biology, including the improvement of nucleic acid extraction and amplification, several PCR-based methods for the diagnosis of BSI directly from whole blood have emerged. In the present review, we discuss the advantages and limitations of these new molecular approaches, which at best complement the culture-based diagnosis of BSI.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The purpose of this research was to study the genetic diversity and genetic relatedness of 60 genotypes of grapevines derived from the Germplasm Bank of Embrapa Semiárido, Juazeiro, BA, Brazil. Seven previously characterized microsatellite markers were used: VVS2, VVMD5, VVMD7, VVMD27, VVMD3, ssrVrZAG79 and ssrVrZAG62. The expected heterozygosity (He) and polymorphic information content (PIC) were calculated, and the cluster analysis were processed to generate a dendrogram using the algorithm UPGMA. The He ranged from 81.8% to 88.1%, with a mean of 84.8%. The loci VrZAG79 and VVMD7 were the most informative, with a PIC of 87 and 86%, respectively, while VrZAG62 was the least informative, with a PIC value of 80%. Cluster analysis by UPGMA method allowed separation of the genotypes according to their genealogy and identification of possible parentage for the cultivars 'Dominga', 'Isaura', 'CG 26916', 'CG28467' and 'Roni Redi'.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

We investigated the decayed historical church window glasses of two Catalonian churches, both under Mediterranean climate. Glass surfaces were studied by scanning electron microscopy (SEM), energy dispersive spectrometry (EDS), and X-ray diffraction (XRD). Their chemical composition was determined by avelength-dispersive spectrometry (WDS) microprobe analysis. The biodiversity was investigated by molecular methods: DNA extraction from glass, amplification by PCR targeting the16S rRNA and ITS regions, and fingerprint analyses by denaturing gradient gel electrophoresis (DGGE). Clone libraries containing either PCR fragments of the bacterial 16S rDNA or the fungal ITS regions were screened by DGGE. Clone inserts were sequenced and compared with the EMBL database.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

We address the challenges of treating polarization and covalent interactions in docking by developing a hybrid quantum mechanical/molecular mechanical (QM/MM) scoring function based on the semiempirical self-consistent charge density functional tight-binding (SCC-DFTB) method and the CHARMM force field. To benchmark this scoring function within the EADock DSS docking algorithm, we created a publicly available dataset of high-quality X-ray structures of zinc metalloproteins ( http://www.molecular-modelling.ch/resources.php ). For zinc-bound ligands (226 complexes), the QM/MM scoring yielded a substantially improved success rate compared to the classical scoring function (77.0% vs 61.5%), while, for allosteric ligands (55 complexes), the success rate remained constant (49.1%). The QM/MM scoring significantly improved the detection of correct zinc-binding geometries and improved the docking success rate by more than 20% for several important drug targets. The performance of both the classical and the QM/MM scoring functions compare favorably to the performance of AutoDock4, AutoDock4Zn, and AutoDock Vina.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Despite the development of novel typing methods based on whole genome sequencing, most laboratories still rely on classical molecular methods for outbreak investigation or surveillance. Reference methods for Clostridium difficile include ribotyping and pulsed-field gel electrophoresis, which are band-comparing methods often difficult to establish and which require reference strain collections. Here, we present the double locus sequence typing (DLST) scheme as a tool to analyse C. difficile isolates. Using a collection of clinical C. difficile isolates recovered during a 1-year period, we evaluated the performance of DLST and compared the results to multilocus sequence typing (MLST), a sequence-based method that has been used to study the structure of bacterial populations and highlight major clones. DLST had a higher discriminatory power compared to MLST (Simpson's index of diversity of 0.979 versus 0.965) and successfully identified all isolates of the study (100 % typeability). Previous studies showed that the discriminatory power of ribotyping was comparable to that of MLST; thus, DLST might be more discriminatory than ribotyping. DLST is easy to establish and provides several advantages, including absence of DNA extraction [polymerase chain reaction (PCR) is performed on colonies], no specific instrumentation, low cost and unambiguous definition of types. Moreover, the implementation of a DLST typing scheme on an Internet database, such as that previously done for Staphylococcus aureus and Pseudomonas aeruginosa ( http://www.dlst.org ), will allow users to easily obtain the DLST type by submitting directly sequencing files and will avoid problems associated with multiple databases.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

In this paper the authors propose a new closed contour descriptor that could be seen as a Feature Extractor of closed contours based on the Discrete Hartley Transform (DHT), its main characteristic is that uses only half of the coefficients required by Elliptical Fourier Descriptors (EFD) to obtain a contour approximation with similar error measure. The proposed closed contour descriptor provides an excellent capability of information compression useful for a great number of AI applications. Moreover it can provide scale, position and rotation invariance, and last but not least it has the advantage that both the parameterization and the reconstructed shape from the compressed set can be computed very efficiently by the fast Discrete Hartley Transform (DHT) algorithm. This Feature Extractor could be useful when the application claims for reversible features and when the user needs and easy measure of the quality for a given level of compression, scalable from low to very high quality.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Cyclosporine-A-loaded PLGA implants were developed intended for ocular route. Implants were prepared using solvent extraction/evaporation technique followed by casting of the cake into rods in a heated surface. XRD patterns showed that cyclosporine-A was completely incorporated into PLGA. FTIR and DSC results indicated alterations on drug molecular conformation aiming to reach the most stable thermodynamic conformation at polymer/drug interface. Implants provided controlled/sustained in vitro release of the drug. During the first 7 weeks, the drug release was controlled by the diffusion of the cyclosporine-A; and between 7-23 week period, the drug diffusion and degradation of PLGA controlled the drug release.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This paper describes selective molecularly imprinted solid-phase extraction of ttMA from urine samples followed by derivatization and analysis by gas chromatography/mass spectrometry (GC/MS). The analytical calibration curve ranged from 0.3 to 7.0 mg L-1 (r = 0.999) and the limit of quantitation (LOQ) was 0.3 mg L-1. The method was applied for the determination of ttMA in urine samples from smokers and concentrations detected ranged from < LOQ to 1.64 mg L-1. Thus, the proposed method proved adequate for the determination of urinary ttMA in the biomonitoring of occupational exposure to low levels of benzene.