988 resultados para Breast imaging


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objective: To assess the health-related quality of life (HRQoL) of regional and rural breast cancer survivors at 12 months post-diagnosis and to identify correlates of HRQoL. Methods: 323 (202 regional and 121 rural) Queensland women diagnosed with unilateral breast cancer in 2006/2007 participated in a population-based, cross-sectional study. HRQoL was measured using the Functional Assessment of Cancer Therapy, Breast plus arm morbidity (FACT-B+4) self-administered questionnaire. Results: In age-adjusted analyses, mean HRQoL scores of regional breast cancer survivors were comparable to their rural counterparts 12 months post-diagnosis (122.9, 95% CI: 119.8, 126.0 vs. 123.7, 95% CI: 119.7, 127.8; p>0.05). Irrespective of residence, younger (<50 years) women reported lower HRQoL than older (50+ years) women (113.5, 95% CI: 109.3, 117.8 vs. 128.2, 95%CI: 125.1, 131.2; p<0.05). Those women who received chemotherapy, reported two complications post-surgery, had poorer upper-body function than most, reported more stress, reduced coping, who were socially isolated, had no confidante for social-emotional support, had unmet healthcare needs, and low health self-efficacy reported lower HRQoL scores. Together, these factors explained 66% of the variance in overall HRQoL. The pattern of results remained similar for younger and older age groups. Conclusions and Implications: The results underscore the importance of supporting and promoting regional and rural breast cancer programs that are designed to improve physical functioning, reduce stress and provide psychosocial support following diagnosis. Further, the information can be used by general practitioners and other allied health professionals for identifying women at risk of poorer HRQoL.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose: Physical activity has become a focus of cancer recovery research as it has the potential to reduce treatment-related burden and optimize health-related quality of life (HRQoL). However, the potential for physical activity to influence recovery may be age-dependent. This paper describes physical activity levels and HRQoL among younger and older women after surgery for breast cancer and explores the correlates of physical inactivity. Methods: A population-based sample of breast cancer patients diagnosed in South-East Queensland, Australia, (n=287) were assessed once every three months, from 6 to 18 months post-surgery. The Functional Assessment of Cancer Therapy-Breast questionnaire (FACTB+4) and items from the Behavioral Risk Factor Surveillance System (BRFSS) questionnaire were used to measure HRQoL and physical activity, respectively. Physical activity was assigned metabolic equivalent task (MET) values, and categorized as < 3, 3 to 17.9 and 18+ MET-hours/weeks. Descriptive statistics, generalized linear models with age stratification (<50 years versus 50+ years), and logistic regression were used for analyses (p=0.05, two-tailed). Results: Younger women who engaged in 3 or more MET-hours/week of physical activity reported a higher HRQoL at 18 months compared to their more sedentary counterparts (p<0.05). Older women reported similar HRQoL irrespective of activity level and consistently reported clinically higher HRQoL than younger women. Increasing age, being overweight or obese, and restricting use of the treated side at six months post-surgery increased the likelihood of sedentary behavior (OR>3, p<0.05). Conclusions: Age influences the potential to observe HRQoL benefits related to physical activity participation. These results also provide relevant information for the design of exercise interventions for breast cancer survivors and highlights that some groups of women are at greater risk of long-term sedentary behavior.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Swelling or lymphedema of the limb, trunk, or breast is considered the most problematic and dreaded concern after treatment for breast cancer and has significant physical, psychological, and social ramifications. Conservative incidence estimates suggest that 20%-30% of breast cancer survivors will experience lymphedema, with the majority of cases (up to 80%) occurring within the first year after surgery. The etiology of secondary lymphedema seems to be multifactorial, with acquired abnormalities as well as preexisting conditions being contributory factors.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose To assess the repeatability and validity of lens densitometry derived from the Pentacam Scheimpflug imaging system. Setting Eye Clinic, Queensland University of Technology, Brisbane, Australia. Methods This prospective cross-sectional study evaluated 1 eye of subjects with or without cataract. Scheimpflug measurements and slitlamp and retroillumination photographs were taken through a dilated pupil. Lenses were graded with the Lens Opacities Classification System III. Intraobserver and interobserver reliability of 3 observers performing 3 repeated Scheimpflug lens densitometry measurements each was assessed. Three lens densitometry metrics were evaluated: linear, for which a line was drawn through the visual axis and a mean lens densitometry value given; peak, which is the point at which lens densitometry is greatest on the densitogram; 3-dimensional (3D), in which a fixed, circular 3.0 mm area of the lens is selected and a mean lens densitometry value given. Bland and Altman analysis of repeatability for multiple measures was applied; results were reported as the repeatability coefficient and relative repeatability (RR). Results Twenty eyes were evaluated. Repeatability was high. Overall, interobserver repeatability was marginally lower than intraobserver repeatability. The peak was the least reliable metric (RR 37.31%) and 3D, the most reliable (RR 5.88%). Intraobserver and interobserver lens densitometry values in the cataract group were slightly less repeatable than in the noncataract group. Conclusion The intraobserver and interobserver repeatability of Scheimpflug lens densitometry was high in eyes with cataract and eyes without cataract, which supports the use of automated lens density scoring using the Scheimpflug system evaluated in the study

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background: Zoledronic acid is used to prevent the bone loss associated with antioestrogen treatments in subjects with breast cancer. Preclinical studies suggest that zoledronic acid may have anticancer activity in its own right. This anticancer possibility with zoledronic acid has not been investigated extensively in clinical trials. Objectives/methods: This evaluation is of a large clinical trial that investigated the effect of zoledronic acid on cancer outcomes in premenopausal women with breast cancer. Results: The trial showed that after 4 years, 94.0% of subjects who were treated with zoledronic acid were disease-free compared with 90.8% of those not treated with zoledronic acid. Recurrence survival was a secondary end point; this occurred in 94.0% with, and 90.9% without, zoledronic acid treatment. Conclusions: Zoledronic acid does have anticancer activity in premenopausal women with cancer.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The anti-estrogen treatment for hormone-sensitive breast cancer and the androgen deprivation therapy for prostate cancer can lead to the development of osteoporosis and bone fractures. Metastases associated with prostate and breast cancer can also occur in bone. Bisphosphonates are used in these types of bone dysfunction. Zoledronic acid is the most potent bisphosphonate. In osteoporosis, zoledronic acid inhibits bone reabsorption and increases bone mineral density for at least a year after intravenous administration. The efficacy and safety of zoledronic acid in osteoporosis secondary to hormone-sensitive cancers (prostate and breast), and in the bone metastases associated with these cancers are reviewed.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Established Monte Carlo user codes BEAMnrc and DOSXYZnrc permit the accurate and straightforward simulation of radiotherapy experiments and treatments delivered from multiple beam angles. However, when an electronic portal imaging detector (EPID) is included in these simulations, treatment delivery from non-zero beam angles becomes problematic. This study introduces CTCombine, a purpose-built code for rotating selected CT data volumes, converting CT numbers to mass densities, combining the results with model EPIDs and writing output in a form which can easily be read and used by the dose calculation code DOSXYZnrc. The geometric and dosimetric accuracy of CTCombine’s output has been assessed by simulating simple and complex treatments applied to a rotated planar phantom and a rotated humanoid phantom and comparing the resulting virtual EPID images with the images acquired using experimental measurements and independent simulations of equivalent phantoms. It is expected that CTCombine will be useful for Monte Carlo studies of EPID dosimetry as well as other EPID imaging applications.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Over the last few years various research groups around the world have employed X-ray Computed Tomography (CT) imaging in the study of mummies – Toronto-Boston (1,2), Manchester(3). Prior to the development of CT scanners, plane X-rays were used in the investigation of mummies. Xeroradiography has also been employed(4). In a xeroradiograph, objects of similar X-ray density (very difficult to see on a conventional X-ray) appear edge-enhanced and so are seen much more clearly. CT scanners became available in the early 1970s. A CT scanner produces cross-sectional X-rays of objects. On a conventional X-radiograph individual structures are often very difficult to see because all the structures lying in the path of the X-ray beam are superimposed, a problem that does not occur with CT. Another advantage of CT is that the information in a series of consecutive images may be combined to produce a three-dimensional reconstruction of an object. Slices of different thickness and magnification may be chosen. Why CT a mummy? Prior to the availability of CT scanners, the only way of finding out about the inside of a mummy in any detail was to unwrap and dissect it. This has been done by various research groups – most notably the Manchester, UK and Pennsylvania University, USA mummy projects(5,6). Unwrapping a mummy and carrying out an autopsy is obviously very destructive. CT studies hold the possibility of producing a lot more information than is possible from plain X-rays and are able to show the undisturbed arrangement of the wrapped body. CT is also able to provide information about the internal structure of bones, organ packs, etc that wouldn’t be possible without sawing through the bones etc. The mummy we have scanned is encased in a coffin which would have to have been broken open in order to remove the body.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE: To compare the repeatability within anterior corneal topography measurements and agreement between measurements with the Pentacam HR rotating Scheimpflug camera and with a previously validated Placido disk–based videokeratoscope (Medmont E300). ------ SETTING: Contact Lens and Visual Optics Laboratory, School of Optometry, Queensland University of Technology, Brisbane, Queensland, Australia. ----- METHODS: Normal eyes in 101 young adult subjects had corneal topography measured using the Scheimpflug camera (6 repeated measurements) and videokeratoscope (4 repeated measurements). The best-fitting axial power corneal spherocylinder was calculated and converted into power vectors. Corneal higher-order aberrations (HOAs) (up to the 8th Zernike order) were calculated using the corneal elevation data from each instrument. ----- RESULTS: Both instruments showed excellent repeatability for axial power spherocylinder measurements (repeatability coefficients <0.25 diopter; intraclass correlation coefficients >0.9) and good agreement for all power vectors. Agreement between the 2 instruments was closest when the mean of multiple measurements was used in analysis. For corneal HOAs, both instruments showed reasonable repeatability for most aberration terms and good correlation and agreement for many aberrations (eg, spherical aberration, coma, higher-order root mean square). For other aberrations (eg, trefoil and tetrafoil), the 2 instruments showed relatively poor agreement. ----- CONCLUSIONS: For normal corneas, the Scheimpflug system showed excellent repeatability and reasonable agreement with a previously validated videokeratoscope for the anterior corneal axial curvature best-fitting spherocylinder and several corneal HOAs. However, for certain aberrations with higher azimuthal frequencies, the Scheimpflug system had poor agreement with the videokeratoscope; thus, caution should be used when interpreting these corneal aberrations with the Scheimpflug system.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Free-radical processes underpin the thermo-oxidative degradation of polyolefins. Thus, to extend the lifetime of these polymers, stabilizers are generally added during processing to scavenge the free radicals formed as the polymer degrades. Nitroxide radical precursors, such as hindered amine stabilizers (HAS),1,2 are common polypropylene additives as the nitroxide moiety is a potent scavenger of polymer alkyl radicals (R¥). Oxidation of HAS by radicals formed during polypropylene degradation yields nitroxide radicals (RRNO¥), which rapidly trap the polymer degradation species to produce alkoxyamines, thus retarding oxidative polymer degradation. This increase in polymer stability is demonstrated by a lengthening of the “induction period” of the polymer (the time prior to a sharp rise in the oxidation of the polymer). Instrumental techniques such as chemiluminescence or infrared spectroscopy are somewhat limited in detecting changes in the polymer during the initial stages of degradation. Therefore, other methods for observing polymer degradation have been sought as the useful life of a polymer does not extend far beyond its “induction period”

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A technique is described whereby micro-ATR/FTIR imaging can be used to follow polymer degradation reactions in situ in real time. The internal reflection element (IRE) assembly is removed from the ATR objective and polymer is solvent cast directly onto the IRE surface. The polymer is then subjected to degradation conditions and molecular structural changes monitored by periodically replacing the IRE assembly back in the ATR objective and collecting spectra which can be used to construct images. This approach has the benefit that the same part of the sample is always studied, and that contact by pressure which might damage the polymer surface is not required. The technique is demonstrated using the polymer Topas which was degraded by exposure to UVC light in air.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Diffraction tomographic imaging is applied to the imaging of shallowly buried targets with multi-bistatic arrays of transmitters and receivers.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A parametric study was carried out to investigate the effects on reconstructed images from a ground penetrating radar (GPR) due to (a) the centre frequency of the GPR excitation pulse, (b) the height of transmitting and receiving antennas above ground level, and (c) the proximity of the buried objects. An integrated software package was developed to streamline the computer simulation based on synthetic data generated by GPRMax.