969 resultados para Bone regeneration, Bone defect, Platelet-rich plasma, Collagen, Animal model, Sheep


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Tithonia diversifolia, also known as Mexican arnica, has been used in traditional medicine to treat inflammatory refractory with absence of citotoxicity. The possible health risks associated with the consumption of ingestion of the infusion (tea) plant makes it is necessary to identify the potential pharmacological activity or toxicity to prove certain plants that are acclimated in Brazil. Considering the limited number of pharmacological studies regarding the Tithonia diversifolia, the aim of this study was evaluate the effects of this infusion in platelet aggregation. Venous blood was collected with informed consent from healthy volunteers who denied taking any medication in the previous 14 days. Whole blood was transferred into polypropylene tubes containing one-tenth of final volume of acid citrate dextrose (ACD-C; citric acid 3%, trisodium citrate 4%, glucose 2%; 1:9 v/v) and centrifuged at 200g for 15 min. Platelet rich plasma was added of wash buffer solution (NaCl 140mM, KCl 5mM, sodium citrate 12mM, glucose 10mM and saccharose 12mM; pH 6; 5:7 v/v) and centrifuged at 800g for 12 min at 20°C. Platelet pellet was gently resuspended in Krebs-Ringer solution and counts were performed on a Neubauer chamber. Aggregation assay was carried out with 400 μL of platelet suspension (1.2x10 8 platelets/mL) in a cuvette at 37°C with constant stirring. Platelet suspension was incubated for 3 min with aqueous extract infusion (0.6-20μg/mL) prior to addition of thrombin (100 mU/mL). Percentage of platelet aggregation was recorded with an aggregometer (Chrono-log Lumi-Aggregometer model 560-Ca, USA). Our results show an inhibition of thrombin induced platelet aggregation in the presence of 0.6-20 ug/mL Tithonia diversifolia infusion leaves. The Tithonia diversifolia infusion leaves inhibits thrombin induced washed platelet aggregation.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Pós-graduação em Pesquisa e Desenvolvimento (Biotecnologia Médica) - FMB

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The aim of this work is to study a still little known technique in the Brazilian Veterinary Medicine, that is the use of the Platelet Rich Plasma (PRP), specifically in the small animals orthopedics, including the concept of PRP, why its use in orthopedics, its production method and application, its indications, vantages and disadvantages, and also evaluate the results achieved through the use of PRP both in Human Medicine as in Veterinary Medicine. Moreover, it aims to establish the feasibility of this technique for its use in veterinary orthopedic surgery, especially as an adjunct in fracture repair

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Pós-graduação em Cirurgia Veterinária - FCAV

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Objective: To evaluate the efficacy of platelet-rich plasma regarding healing, pain and hemostasis after total knee arthroplasty, by means of a blinded randomized controlled and blinded clinical study. Methods: Forty patients who were going to undergo implantation of a total knee prosthesis were selected and randomized. In 20 of these patients, platelet-rich plasma was applied before the joint capsule was closed. The hemoglobin (mg/dL) and hematocrit (%) levels were assayed before the operation and 24 and 48hours afterwards. The Womac questionnaire and a verbal pain scale were applied and knee range of motion measurements were made up to the second postoperative month. The statistical analysis compared the results with the aim of determining whether there were any differences between the groups at each of the evaluation times. Results: The hemoglobin (mg/dL) and hematocrit (%) measurements made before the operation and 24 and 48hours afterwards did not show any significant differences between the groups (p > 0.05). The Womac questionnaire and the range of motion measured before the operation and up to the first two months also did not show any statistical differences between the groups (p > 0.05). The pain evaluation using the verbal scale showed that there was an advantage for the group that received platelet-rich plasma, 24hours, 48hours, one week, three weeks and two months after the operation (p < 0.05). Conclusions: In the manner in which the platelet-rich plasma was used, it was not shown to be effective for reducing bleeding or improving knee function after arthroplasty, in comparison with the controls. There was an advantage on the postoperative verbal pain scale.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

OBJETIVO: Avaliar os resultados funcionais e o índice de rerrotura do reparo do manguito rotador por via artroscópica associado ao uso do PRP. MÉTODOS: Série de casos prospectiva, avaliando os resultados do reparo artroscópico do manguito rotador em fileira simples associada ao uso do PRP. Foram incluídas apenas roturas isoladas do supraespinal, com retração inferior a 3cm. O PRP utilizado foi obtido pelo método de aférese, e aplicado em sua forma ativada, com a adição de trombina autóloga, na consistência líquida. A avaliação pós-operatória foi realizada de maneira padronizada, aos 12 meses de seguimento. Foram utilizadas as escalas de Constant-Murley, UCLA e EVA, além da análise da incidência de rerroturas através da ressonância magnética. RESULTADOS: Foram avaliados 14 pacientes (14 ombros). A escala de Constant-Murley evoluiu em média de 45,64 ± 12,29 no pré-operatório para 80,78 ± 13,22 no pós-operatório (p < 0,001). A escala de UCLA sofreu um incremento de 13,78 ± 5,66 para 31, 43 ± 3,9 (p < 0,001). A dor dos pacientes apresentou uma melhora significativa de acordo com a EVA (p = 0,0013), decrescendo de uma mediana de 7,5 (p25% = 6, p75% = 8) para 0,5 (p25% = 0, p75% = 3). Nenhum dos pacientes apresentou rerrotura completa. Em três pacientes (21,4%) foi observada uma rerrotura parcial, sem transfixação. Apenas um paciente evoluiu com complicação (capsulite adesiva). CONCLUSÃO: Os pacientes submetidos ao reparo do manguito rotador por via artroscópica associado ao uso do PRP apresentaram uma melhora funcional significativa e nenhuma rerrotura completa.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Glycoprotein (GP) VI, the primary collagen receptor on platelets, has been shown to have variable expression, possibly as a consequence of immune modulation. The present study was designed to determine the mechanism by which GP VI clearance occurs. We found that direct activation of GP VI both by a GP VI-specific antibody and by GP VI ligands (collagen and convulxin) reduced binding of biotinylated convulxin to the stimulated platelets. Analysis of immunoblots of platelets and supernatants showed that the stimulated platelets contained less GP VI, while the soluble fraction contained a 57-kDa cleavage product. Stimulation of platelets with PAR-1 agonists (TRAP peptide and thrombin) also caused GP VI cleavage, although the amount of GP VI loss was less than that observed with direct GP VI ligands. The metalloproteinase (MMP) inhibitors GM6001 and TAPI prevented both the clearance of GP VI from the platelet surface and the appearance of the soluble cleavage product. Induction of GP VI cleavage caused specific down-regulation of collagen-induced platelet aggregation, providing a mechanism for the modulation of platelet responsiveness to this important platelet agonist.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

BACKGROUND: Complete investigation of thrombophilic or hemorrhagic clinical presentations is a time-, apparatus-, and cost-intensive process. Sensitive screening tests for characterizing the overall function of the hemostatic system, or defined parts of it, would be very useful. For this purpose, we are developing an electrochemical biosensor system that allows measurement of thrombin generation in whole blood as well as in plasma. METHODS: The measuring system consists of a single-use electrochemical sensor in the shape of a strip and a measuring unit connected to a personal computer, recording the electrical signal. Blood is added to a specific reagent mixture immobilized in dry form on the strip, including a coagulation activator (e.g., tissue factor or silica) and an electrogenic substrate specific to thrombin. RESULTS: Increasing thrombin concentrations gave standard curves with progressively increasing maximal current and decreasing time to reach the peak. Because the measurement was unaffected by color or turbidity, any type of blood sample could be analyzed: platelet-poor plasma, platelet-rich plasma, and whole blood. The test strips with the predried reagents were stable when stored for several months before testing. Analysis of the combined results obtained with different activators allowed discrimination between defects of the extrinsic, intrinsic, and common coagulation pathways. Activated protein C (APC) predried on the strips allowed identification of APC-resistance in plasma and whole blood samples. CONCLUSIONS: The biosensor system provides a new method for assessing thrombin generation in plasma or whole blood samples as small as 10 microL. The assay is easy to use, thus allowing it to be performed in a point-of-care setting.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Nanomedicine is a new branch of medicine, based on the potentiality and intrinsic properties of nanomaterials. Indeed, the nanomaterials ( i.e. the materials with nano and under micron size) can be suitable to different applications in biomedicine. The nanostructures can be used by taking advantage of their properties (for example superparamagnetic nanoparticles) or functionalized to deliver the drug in a specific target, thanks the ability to cross biological barriers. The size and the shape of 1D-nanostructures (nanotubes and nanowires) have an important role on the cell fate: their morphology plays a key role on the interaction between nanostructure and the biological system. For this reason the 1D nanostructure are interesting for their ability to mime the biological system. An implantable material or device must therefore integrate with the surrounding extracellular matrix (ECM), a complex network of proteins with structural and signaling properties. Innovative techniques allow the generation of complex surface patterns that can resemble the structure of the ECM, such as 1D nanostructures. NWs based on cubic silicon carbide (3C-SiC), either bare (3C-SiC NWs) or surrounded by an amorphous shell (3C-SiC/SiO2 core/shell NWs), and silicon oxycarbide nanowires (SiOxCy NWs) can meet the chemical, mechanical and electrical requirements for tissue engineering and have a strong potential to pave the way for the development of a novel generation of implantable nano-devices. Silicon oxycarbide shows promising physical and chemical properties as elastic modulus, bending strength and hardness, chemical durability superior to conventional silicate glasses in aggressive environments and high temperature stability up to 1300 °C. Moreover, it can easily be engineered through functionalization and decoration with macro-molecules and nanoparticles. Silicon carbide has been extensively studied for applications in harsh conditions, as chemical environment, high electric field and high and low temperature, owing to its high hardness, high thermal conductivity, chemical inertness and high electron mobility. Also, its cubic polytype (3C) is highly biocompatible and hemocompatible, and some prototypes of biomedical applications and biomedical devices have been already realized starting from 3C-SiC thin films. Cubic SiC-based NWs can be used as a biomimetic biomaterial, providing a robust and novel biocompatible biological interface . We cultured in vitro A549 human lung adenocarcinoma epithelial cells and L929 murine fibroblast cells over core/shell SiC/SiO2, SiOxCy and bare 3C-SiC nanowire platforms, and analysed the cytotoxicity, by indirect and direct contact tests, the cell adhesion, and the cell proliferation. These studies showed that all the nanowires are biocompatible according to ISO 10993 standards. We evaluated the blood compatibility through the interaction of the nanowires with platelet rich plasma. The adhesion and activation of platelets on the nanowire bundles, assessed via SEM imaging and soluble P-selectin quantification, indicated that a higher platelet activation is induced by the core/shell structures compared to the bare ones. Further, platelet activation is higher with 3C-SiC/SiO2 NWs and SiOxCyNWs, which therefore appear suitable in view of possible tissue regeneration. On the contrary, bare 3C-SiC NWs show a lower platelet activation and are therefore promising in view of implantable bioelectronics devices, as cardiovascular implantable devices. The NWs properties are suitable to allow the design of a novel subretinal Micro Device (MD). This devices is based on Si NWs and PEDOT:PSS, though the well know principle of the hybrid ordered bulk heterojunction (OBHJ). The aim is to develop a device based on a well-established photovoltaic technology and to adapt this know-how to the prosthetic field. The hybrid OBHJ allows to form a radial p–n junction on a nanowire/organic structure. In addition, the nanowires increase the light absorption by means of light scattering effects: a nanowires based p-n junction increases the light absorption up to the 80%, as previously demonstrated, overcoming the Shockley-Queisser limit of 30 % of a bulk p-n junction. Another interesting employment of these NWs is to design of a SiC based epicardial-interacting patch based on teflon that include SiC nanowires. . Such contact patch can bridge the electric conduction across the cardiac infarct as nanowires can ‘sense’ the direction of the wavefront propagation on the survival cardiac tissue and transmit it to the downstream surivived regions without discontinuity. The SiC NWs are tested in terms of toxicology, biocompatibility and conductance among cardiomyocytes and myofibroblasts.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Objectives:The aim of this study was to assess the biological rationale for the use of platelet-rich plasma (PRP) by evaluating the effect of different concentrations of PRP on osteoblasts (OB) and fibroblasts (FB) function in vitro. Materials and methods:PRP was obtained from volunteer donors using standard protocols. Primary human cultures of oral FBs and OBs were exposed to both activated and non-activated plasma as well as various concentrations of PRP (2.5 x, 3.5 x and max (4.2-5.5 x)). Cell proliferation was evaluated after 24 and 72 h using an MTT proliferation assay. Production of osteocalcin (OCN), osteoprotegerin (OPG) and transforming growth factor beta 1 (TGF-beta 1) was evaluated in OB after 24 and 72 h. Statistical analysis was performed using one-way ANOVA. Results:PRP-stimulated cell proliferation in both OBs and FBs. The effect of different PRP concentrations on cell proliferation was most notable at 72 h. The maximum effect was achieved with a concentration of 2.5 x, with higher concentrations resulting in a reduction of cell proliferation. Upregulation of OCN levels and downregulation of OPG levels were noted with increasing PRP concentrations at both 24 and 72 h. TGF-beta 1 levels were stimulated by increasing concentrations of PRP, with the increased levels being maintained at 72 h. Conclusions:PRP preparations exert a dose-specific effect on oral FBs and OBs. Optimal results were observed at a platelet concentration of 2.5 x, which was approximately half of the maximal concentrate that could be obtained. Increased concentrations resulted in a reduction in proliferation and a suboptimal effect on OB function. Hence, different PRP concentrations may have an impact on the results that can be obtained in vivo.