956 resultados para Automated community detection


Relevância:

30.00% 30.00%

Publicador:

Resumo:

The present work demonstrates the successful application of automated biocompatible in-tube solid-phase microextraction coupled with liquid chromatography (in-tube SPME/LC) for determination of interferon alpha(2a) (IFN alpha(2a)) in plasma samples for therapeutic drug monitoring. A restricted access material (RAM, protein-coated silica) was employed for preparation of a lab-made biocompatible in-tube SPME capillary that enables the direct injection of biological fluids as well as the simultaneous exclusion of macromolecules by chemical diffusion barrier and drug pre-concentration. The in-tube SPME variables, such as sample volume, draw/eject volume, number of draw-eject cycles, and desorption mode were optimized, to improve the sensitivity of the proposed method. The IFN alpha(2a) analyses in plasma sample were carried out within 25 min (sample preparation and LC analyses). The response of the proposed method was linear over a dynamic range, from 0.06 to 3.0 MIU mL(-1), with correlation coefficient equal to 0.998. The interday precision of the method presented coefficient of variation lower than 8%. The proposed automated method has adequate analytical sensitivity and selectivity for determination of IFN alpha(2a) in plasma samples for therapeutic drug monitoring. (C) 2010 Elsevier B.V. All rights reserved.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Formal methods and software testing are tools to obtain and control software quality. When used together, they provide mechanisms for software specification, verification and error detection. Even though formal methods allow software to be mathematically verified, they are not enough to assure that a system is free of faults, thus, software testing techniques are necessary to complement the process of verification and validation of a system. Model Based Testing techniques allow tests to be generated from other software artifacts such as specifications and abstract models. Using formal specifications as basis for test creation, we can generate better quality tests, because these specifications are usually precise and free of ambiguity. Fernanda Souza (2009) proposed a method to define test cases from B Method specifications. This method used information from the machine s invariant and the operation s precondition to define positive and negative test cases for an operation, using equivalent class partitioning and boundary value analysis based techniques. However, the method proposed in 2009 was not automated and had conceptual deficiencies like, for instance, it did not fit in a well defined coverage criteria classification. We started our work with a case study that applied the method in an example of B specification from the industry. Based in this case study we ve obtained subsidies to improve it. In our work we evolved the proposed method, rewriting it and adding characteristics to make it compatible with a test classification used by the community. We also improved the method to support specifications structured in different components, to use information from the operation s behavior on the test case generation process and to use new coverage criterias. Besides, we have implemented a tool to automate the method and we have submitted it to more complex case studies

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Objectives:The aim of this in vitro study was to assess the inter- and intra-examiner reproducibility and the accuracy of the International Caries Detection and Assessment System-II (ICDAS-II) in detecting occlusal caries.Methods:One hundred and sixty-three molars were independently assessed twice by two experienced dentists using the 0- to 6-graded ICDAS-II. The teeth were histologically prepared and classified using two different histological systems [Ekstrand et al. (1997) Caries Research vol. 31, pp. 224-231; Lussi et al. (1999) Caries Research vol. 33, pp. 261-266] and assessed for caries extension. Sensitivity, specificity, accuracy and area under the ROC curve (A(z)) were obtained at D(2) and D(3) thresholds. Unweighted kappa coefficient was used to assess inter- and intra-examiner reproducibility.Results:For the Ekstrand et al. histological classification the sensitivity was 0.99 and 1.00, specificity 1.00 and 0.69 and accuracy 0.99 and 0.76 at D(2) and D(3), respectively. For the Lussi et al. histological classification the sensitivity was 0.91 and 0.75, specificity 0.47 and 0.62 and accuracy 0.86 and 0.68 at D(2) and D(3), respectively. The A(z) varied from 0.54 to 0.73. The inter- and intra-examiner kappa values were 0.51 and 0.58, respectively.Conclusions:ICDAS-II presented good reproducibility and accuracy in detecting occlusal caries, especially caries lesions in the outer half of the enamel.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

An automated system with a C-18 bonded silica gel packed minicolumn is proposed for spectrophotometric detection of arsenic using flow-injection hydride generation following sorbent extraction preconcentration. Complexes formed between arsenic(III) and ammonium diethyl dithiophosphate (ADDP) are retained on a C-18 sorbent. The eluted As-DDP complexes are merged with a 1.5% (w/v) NaBH4 and the resulting solution is thereafter injected into the hydride generator/gas-liquid separator. The arsine generated is carried out by a stream of N-2 and trapped in an alkaline iodine solution in which the analyte is determined by the arsenomolybdenum blue method. With preconcentration time of 120 s, calibration in the 5.00-50.0 mu g As l(-1) range and sampling rate of about 20 samples h(-1) are achieved, corresponding to 36 mg ADDP plus 36 mg ammonium heptamolybdate plus 7 mg hydrazine sulfate plus 0.7 mg stannous chloride and about 7 mi sample consumed per determination. The detection limit is 0.06 mu g l(-1) and the relative standard deviation (n = 12) for a typical 17.0 mu g As l(-1) sample is ca. 6%. The accuracy was checked for arsenic determination in plant materials from the NIST (1572 citrus leaves; 1573 tomato leaves) and the results were in agreement with the certified values at 95% confidence level. Good recoveries (94-104%) of spiked tap waters, sugars and synthetic mixtures of trivalent and pentavalent arsenic were also found. (C) 1999 Elsevier B.V. B.V. All rights reserved.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Toxoplasma gondii infection may lead to important pathological questions, especially in rural areas, where several sources of infection exist. Therefore, it is important to determine risk factors in order to establish adequate prophylactic measures. The present study aimed to assess the prevalence and risk factors involved in human toxoplasmosis infection in a rural community, in Eldorado, Mato Grosso do Sul State, Brazil. This community was composed of 185 farms - with 671 inhabitants - from which 20 were randomly chosen. In these farms, blood samples were collected from rural workers, who also answered a risk factor questionnaire. Serum samples were analyzed by means of direct agglutination test for the detection of anti-Toxoplasma gondii antibodies. From 73 samples collected, 79.45% were positive. None of the studied variables was significantly associated with the prevalence of the infection. However, among the individuals who reported eyesight impairments, 94.4% had anti-T. gondii antibodies, compared with 74.0% who did not report eyesight changes (p = 0.0594). Moreover, most individuals in the study (68.20%) were older than 18 years and presented 84.44% positivity, compared with 66.67% of positive individuals younger than 18 years old. We were able to conclude that a high prevalence of antibodies did not imply significant associations with the risk factors studied.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

A simple, rapid, and automated assay for hydrogen peroxide in pharmaceutical samples was developed by combining the multicommutation system with a chemiluminescence (CL) detector. The detection was performed using a spiral flow-cell reactor made from polyethylene tubing that was positioned in front of a photodiode. It allows the rapid mixing of CL reagent and analyte and simultaneous detection of the emitted light. The chemiluminescence was based on the reaction of luminol with hydrogen peroxide catalyzed by hexacyanoferrate(III). The feasibility of the flow system was ascertained by analyzing a set of pharmaceutical samples. A linear response within the range of 2.2-210 μmol l-1 H2O2 with a LD of 1.8 μmol l-1 H2O2 and coefficient of variations smaller than 0.8% for 1.0×10-5 mol l-1 and 6.8×10-5 mol l-1 hydrogen peroxide solutions (n=10) were obtained. Reagents consumption of 90 μg of luminol and 0.7 mg of hexacyanoferrate(III) per determination and sampling rate of 200 samples per hour were also achieved. Copyright © Taylor & Francis Group, LLC.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

C-reactive protein (CRP) is an acute phase protein whose levels are increased in many disorders. There exists, in particular, a great deal of interest in the correlation between blood serum levels and the severity of risk for cardiovascular disease. A sensitive, label-free, non-amplified and reusable electrochemical impedimetric biosensor for the detection of CRP in blood serum was developed herein based on controlled and coverage optimised antibody immobilization on standard polycrystalline gold electrodes. Charge transfer resistance changes were highly target specific, linear with log. CRP. concentration across a 0.5-50. nM range and associated with a limit of detection of 176. pM. Significantly, the detection limits are better than those of current CRP clinical methods and the assays are potentially cheap, relatively automated, reusable, multiplexed and highly portable. The generated interfaces were capable not only of comfortably quantifying CRP across a clinically relevant range of concentrations but also of doing this in whole blood serum with interfaces that were, subsequently, reusable. The importance of optimising receptor layer resistance in maximising assay sensitivity is also detailed. © 2012.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Members of the Staphylococcus genus, especially Staphylococcus aureus, are the most common pathogens found in hospitals and in community-acquired infections. Some of their pathogenicity is associated with enzyme and toxin production. Until recently, S. aureus was the most studied species in the genus; however, in last few years, the rise of infections caused by coagulase-negative staphylococci has pointed out the need for further studies on virulence factors that have not yet been completely elucidated so as to better characterize the pathogenic potential of this group of microorganisms. Several staphylococcal species produce enterotoxins, a family of related proteins responsible for many diseases, such as the toxic-shock syndrome, septicemia and food poisoning. To this date, 23 different enterotoxin types have been identified besides toxic-shock syndrome toxin-1 (TSST-1), and they can be divided into five phylogenetic groups. The mechanism of action of these toxins includes superantigen activity and emetic properties, which can lead to biological effects of infection. Various methods can detect genes that encode enterotoxins and their production. Molecular methods are the most frequently used at present. This review article has the objective to describe aspects related to the classification, structure and regulation of enterotoxins and toxic-shock syndrome toxin-1 detection methods.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

BACKGROUND: Dengue is the most important arboviral disease in the world. Dengue viruses (DENVs) have produced huge outbreaks in Brazil in the past 25 years with more than 5 million reported cases. During these epidemics, asymptomatic individuals infected with DENV could donate blood and serve as a source of virus dissemination in the community. Here, we studied the circulation of DENV in healthy individuals during an epidemic outbreak. STUDY DESIGN AND METHODS: The study included 500 serum samples from healthy blood donors collected at the Hemotherapy Center of Ribeirao Preto, Brazil, during a dengue outbreak. The presence of DENV RNA in the serum samples was screened by real-time reverse transcriptionpolymerase chain reaction (PCR). The virus serotype was determined by a heminested PCR procedure. A partial fragment of the NS5 gene sequence was used for phylogenetic analysis. RESULTS: DENV RNA was detected in the serum sample of 2 of 500 (0.4%) individuals. Both of them were infected with DENV-3 Genotype III, a virus that has been circulating in Brazil in the past decade. CONCLUSION: Individuals with asymptomatic DENV infection can be blood donors and serve as a source of virus dissemination in the community. Further studies are needed to determine the risk of recipient infection by DENV as a result of transfusion in Brazil, especially during epidemic periods.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

A thin-layer electrochemical flow cell coupled to capillary electrophoresis with contactless conductivity detection (EC-CE-(CD)-D-4) was applied for the first time to the derivatization and quantification of neutral species using aliphatic alcohols as model compounds. The simultaneous electrooxidation of four alcohols (ethanol, 1-propanol, 1-butanol, and 1-pentanol) to the corresponding carboxylates was carried out on a platinum working electrode in acid medium. The derivatization step required 1 min at 1.6 V vs. Ag/AgCl under stopped flow conditions, which was preceded by a 10 s activation at 0 V. The solution close to the electrode surface was then hydrodynamically injected into the capillary, and a 2.5 min electrophoretic separation was carried out. The fully automated flow system operated at a frequency of 12 analyses per hour. Simultaneous determination of the four alcohols presented detection limits of about 5 x 10(-5) mol As a practical application with a complex matrix, ethanol concentrations were determined in diluted pale lager beer and in nonalcoholic beer. No statistically significant difference was observed between the EC-CE-(CD)-D-4 and gas chromatography with flame ionization detection (GC-FID) results for these samples. The derivatization efficiency remained constant over several hours of continuous operation with lager beer samples (n = 40).

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Background: The Beck Depression Inventory (BDI) is used worldwide for detecting depressive symptoms. This questionnaire has been revised (1996) to match the DSM-IV criteria for a major depressive episode. We assessed the reliability and the validity of the Brazilian Portuguese version of the BDI-II for non-clinical adults. Methods: The questionnaire was applied to 60 college students on two occasions. Afterwards, 182 community-dwelling adults completed the BDI-II, the Self-Report Questionnaire, and the K10 Scale. Trained psychiatrists performed face-to-face interviews with the respondents using the Structured Clinical Interview (SCID-I), the Montgomery-angstrom sberg Depression Scale, and the Hamilton Anxiety Scale. Descriptive analysis, signal detection analysis (Receiver Operating Characteristics), correlation analysis, and discriminant function analysis were performed to investigate the psychometric properties of the BDI-II. Results: The intraclass correlation coefficient of the BDI-II was 0.89, and the Cronbach's alpha coefficient of internal consistency was 0.93. Taking the SCID as the gold standard, the cut-off point of 10/11 was the best threshold for detecting depression, yielding a sensitivity of 70% and a specificity of 87%. The concurrent validity (a correlation of 0.63-0.93 with scales applied simultaneously) and the predictive ability of the severity level (over 65% correct classification) were acceptable. Conclusion: The BDI-II is reliable and valid for measuring depressive symptomatology among Portuguese-speaking Brazilian non-clinical populations.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The proportion of Plasmodium vivax-infected subjects that carry mature gametocytes, and thus are potentially infectious, remains poorly characterized in endemic settings. Here, we describe a quantitative reverse transcriptase (RI) real-time PCR (qRT-PCR) that targets transcripts of the mature gametocyte-specific pvs25 gene. We found mature gametocytes in 42 of 44 (95.4%) P. vivax infections diagnosed during an ongoing cohort study in northwestern Brazil. SYBR green qRT-PCR was more sensitive than a conventional RT-PCR that targets the same gene. Molecular detection of gametocytes failed, however, when dried bloodspots were used for RNA isolation and complementary DNA synthesis. Estimating the number of pvs25 gene transcripts allowed for examining the potential infectiousness of gametocyte carriers in a quantitative way. We found that most (61.9%) gametocyte carriers were either asymptomatic or had subpatent parasitemias and would have been missed by routine malaria control strategies. However, potentially undiagnosed gametocyte carriers usually had low-density infections and contributed a small fraction (up to 4%) to the overall gametocyte burden in the community. Further studies are required to determine the relative contribution to malaria transmission of long-lasting but low-density gametocytemias in asymptomatic carriers that are left undiagnosed and untreated. (C) 2012 Elsevier Inc. All rights reserved.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Background. Respiratory syncytial virus (RSV) has been implicated in the etiology of adult community-acquired pneumonia (CAP). We investigated RSV infection in Chilean adults with CAP using direct viral detection, real-time reverse-transcription polymerase chain reaction (rtRT-PCR), and serology (microneutralization assay). Methods. RSV, other respiratory viruses, and bacteria were studied by conventional and molecular techniques in adults aged >= 18 years presenting with CAP to the healthcare facilities in Santiago, Chile from February 2005 through December 2007. Results. All 356 adults with CAP enrolled had an acute blood sample collected at enrollment, and 184 had a convalescent blood sample. RSV was detected in 48 cases (13.4%). Immunofluorescence assay and viral isolation each detected only 1 infection (0.2%), whereas rtRT-PCR was positive in 32 (8.9%) cases and serology was positive in 20 (10.8%) cases. CAP clinical characteristics were similar in RSV-infected and non-RSV-infected cases. RSV-specific geometric mean serum-neutralizing antibody titer (GMST) was significantly lower at admission in the 48 RSV-infected cases compared with 308 non-RSV-infected adults (GMST in log(2): RSV/A 8.1 vs 8.9, and RSV/B 9.3 vs 10.4; P < .02). Conclusions. RSV infection is frequent in Chilean adults with CAP. Microneutralization assay was as sensitive as rtRT-PCR in detecting RSV infection and is a good adjunct assay for diagnostic research. High RSV-specific serum-neutralizing antibody levels were associated with protection against common and severe infection. The development of a vaccine could prevent RSV-related CAP in adults.