This study reports characteristics of inertia-gravity waves (IGWs) in the atmospheric boundary layer during the passage of Tropical Cylone-03B, using the Doppler Sound Detection and Ranging (SODAR) observations at the Indian tropical station of Gadanki (13.45 degrees N, 79.2 degrees E; near the east coast of India). Wavelet analysis of horizontal winds indicates significant wave motion (60h) near the characteristic inertial period. The hodograph analysis of the filtered winds shows an anti-cyclonic turning of horizontal wind with height and time, indicating the presence of IGW. This study finds important implications in boundary layer dynamics during the passage of tropical cyclones.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In the present work, the spray structure of diesel from a 200-mu m, single-hole solenoid injector is studied using microscopic imaging at injection pressures of 700, 1000 and 1400 bar for various gas pressures. A long-distance microscope with a high resolution camera is used for spray visualization with a direct imaging technique. This study shows that even at very high injection pressures, the spray structure in an ambient environment of atmospheric pressure reveals presence of entangled ligaments and non-spherical droplets during the injection period. With increase in the injection pressure, the ligaments tend to get smaller and spread radially. The spray structure studies are also conducted at high gas pressures in a specially designed high pressure chamber with optical access. The near nozzle spray structure at the end of the injection shows that the liquid jet breakup is improved with increase in gas density. The droplet size measurement is possible only late in the injection duration when the breakup appears to be complete and mostly spherical droplets are observed. Hence, droplet size measurements are performed after 1.3 ms from start of the injection pulse. Spatial and temporal variation in Sauter Mean `Diameter (SMD) is observed and reported for the case corresponding to an injection pressure of 700 bar. Overall, this study has highlighted the importance of verifying the extentof atomization and droplet shape even in dense sprays before using conventional dropsizing methods such as PDPA.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Strong atmospheric turbulence is a major hindrance in wireless optical communication systems. In this paper, the performance of a wireless optical communication system is analyzed using different modulation formats such as, binary phase shift keying-subcarrier intensity modulation (BPSK-SIM), differential phase shift keying (DPSK), differential phase shift keying-subcarrier intensity modulation (DPSK-SIM), Mary pulse position modulation (M-PPM) and polarization shift keying (PoISK). The atmospheric channel is modeled for strong atmospheric turbulences with combined effect of turbulence and pointing errors. Novel closed-form analytical expressions for average bit error rate (BER), channel capacity and outage probability for the various modulation techniques, viz. BPSK-SIM, DPSK, DPSK-SIM, PoISK and M-PPM are derived. The simulated results for BER, channel capacity and outage probability of various modulation techniques are plotted and analyzed. (C) 2014 Elsevier GmbH. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Tradeoffs are examined between mitigating black carbon (BC) and carbon dioxide (CO2) for limiting peak global mean warming, using the following set of methods. A two-box climate model is used to simulate temperatures of the atmosphere and ocean for different rates of mitigation. Mitigation rates for BC and CO2 are characterized by respective timescales for e-folding reduction in emissions intensity of gross global product. There are respective emissions models that force the box model. Lastly there is a simple economics model, with cost of mitigation varying inversely with emission intensity. Constant mitigation timescale corresponds to mitigation at a constant annual rate, for example an e-folding timescale of 40 years corresponds to 2.5% reduction each year. Discounted present cost depends only on respective mitigation timescale and respective mitigation cost at present levels of emission intensity. Least-cost mitigation is posed as choosing respective e-folding timescales, to minimize total mitigation cost under a temperature constraint (e.g. within 2 degrees C above preindustrial). Peak warming is more sensitive to mitigation timescale for CO2 than for BC. Therefore rapid mitigation of CO2 emission intensity is essential to limiting peak warming, but simultaneous mitigation of BC can reduce total mitigation expenditure. (c) 2015 Elsevier B.V. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Biodiesel run engines are gaining popularity since the last few years as a viable alternative to conventional petro-diesel based engines. In biodiesel exhaust the content of volatile organic compounds, oil mist, and mass of particulate matter is considerably lower. However, the concentration of oxides of nitrogen (NOx) is relatively higher. In this paper the biodiesel exhaust from a stationary engine is treated under controlled laboratory conditions for removal of NOx using dielectric barrier discharge plasma in cascade with adsorbents prepared from abundantly available industrial waste byproducts like red mud and copper slag. Results were compared with gamma-alumina, a commercial adsorbent. Two different dielectric barrier discharge (DBD) reactors were tested for their effectiveness under Repetitive pulses /AC energization. NOx removal as high as 80% was achieved with pulse energized reactors when cascaded with red mud as adsorbent.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Gas discharge plasmas used for thinfilm deposition by plasma-enhanced chemical vapor deposition (PECVD) must be devoid of contaminants, like dust or active species which disturb the intended chemical reaction. In atmospheric pressure plasma systems employing an inert gas, the main source of such contamination is the residual air inside the system. To enable the construction of an atmospheric pressure plasma (APP) system with minimal contamination, we have carried out fluid dynamic simulation of the APP chamber into which an inert gas is injected at different mass flow rates. On the basis of the simulation results, we have designed and built a simple, scaled APP system, which is capable of holding a 100 mm substrate wafer, so that the presence of air (contamination) in the APP chamber is minimized with as low a flow rate of argon as possible. This is examined systematically by examining optical emission from the plasma as a function of inert gas flow rate. It is found that optical emission from the plasma shows the presence of atmospheric air, if the inlet argon flow rate is lowered below 300 sccm. That there is minimal contamination of the APP reactor built here, was verified by conducting an atmospheric pressure PECVD process under acetylene flow, combined with argon flow at 100 sccm and 500 sccm. The deposition of a polymer coating is confirmed by infrared spectroscopy. X-ray photoelectron spectroscopy shows that the polymer coating contains only 5% of oxygen, which is comparable to the oxygen content in polymer deposits obtained in low-pressure PECVD systems. (C) 2015 AIP Publishing LLC.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

利用特殊设计的等离子体发生器,选择等离子体产生的工艺参数,实现工艺过程的精确控制,在大气压环境下获得了性能稳定的氖气直流层流等离子体射流。与湍流等离子体射流长度较短、径向尺寸较大、工作噪音高等特点相比,层流等离于体射流长度可达到550mm,而且沿整个射流长度其径向尺寸维持不变,工作噪音很小。当气流量为120cm~3/s、弧电流在70-200A的范围时,射流长度随弧电流的增加而增加,热效率起初略有降低然后维持平稳。随气流量的增加,层流等离子体射流的热效率也增加,在弧电流为200A时,可以达到40%。实验中测

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The generation, jet length and flow-regime change characteristics of argon plasma issuing into ambient air have been experimentally examined. Different torch structures have been used in the tests. Laminar plasma jets can be generated within a rather wide range of working-gas flow rates, and an unsteady transitional flow state exists between the laminar and turbulent flow regimes. The high-temperature region length of the laminar plasma jet can be over an order longer than that of the turbulent plasma jet and increases with increasing argon flow rate or arc current, while the jet length of the turbulent plasma is less influenced by the generating parameters. The flow field of the plasma jet has very high radial gradients of plasma parameters, and a Reynolds number alone calculated in the ordinary manner may not adequately serve as a criterion for transition. The laminar plasma jet can have a higher velocity than that of an unsteady or turbulent jet. The long laminar plasma jet has good stiffness to withstand the impact of laterally injected cold gas and particulate matter. It could be used as a rather ideal object for fundamental studies and be applied to novel materials processing due to its attractive stable and adjustable properties.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Long, laminar plasma jets at atmospheric pressure of pure argon and a mixture of argon and nitrogen with jet length up to 45 fi,Hes its diameter could be generated with a DC are torch by! restricting the movement of arc root in the torch channel. Effects of torch structure, gas feeding, and characteristics of power supply on the length of plasma jets were experimentally examined. Plasma jets of considerable length and excellent stability could be obtained by regulating the generating parameters, including are channel geometry gas flow I ate, and feeding methods, etc. Influence of flow turbulence at the torch,nozzle exit on the temperature distribution of plasma jets was numerically simulated. The analysis indicated that laminar flow plasma with very low initial turbulent kinetic energy will produce a long jet, with low axial temperature gradient. This kind of long laminar plasma jet could greatly improve the controllability for materials processing, compared with a short turbulent are let.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

An efficient method for solving the spatially inhomogeneous Boltzmann equation in a two-term approximation for low-pressure inductively coupled plasmas has been developed. The electron distribution function (EDF), a function of total electron energy and two spatial coordinates, is found self-consistently with the static space-charge potential which is computed from a 2D fluid model, and the rf electric field profile which is calculated from the Maxwell equations. The EDF and the spatial distributions of the electron density, potential, temperature, ionization rate, and the inductive electric field are calculated and discussed. (C) 1996 American Institute of Physics.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The center of low pressure of a tropical disturbance which moved northward in the Gulf of Mexico, reached land between Panama City and Port St. Joe, Florida, on September 20, 1969. This system was nearly stationary for 48 hours producing heavy rainfall in the Quincy-Havana area, 70-80 miles northeast of the center. Rainfall associated with the tropical disturbance exceeded 20 inches over a part of Gadsden County, Florida, during September 20 through 23, 1969, and the maximum rainfall of record occurred at Quincy with 10.87 inches during a 6-hour period on September 21. The 48-hour maximum of 17.71 inches exceeded the 1 in 100-year probability of 16 inches for a 7-day period. The previous maximum rainfall of record at Quincy (more than 12 inches) was on September 14-15, 1924. The characteristics of this historical storm were similar in path and effect to the September 1969 tropical disturbance. Peak runoff from a 1.4-square mile area near Midway, Florida, was 1,540 cfs (cubic feet per second) per square mile. A peak discharge of 45,600 cfs on September 22 at the gaging station on the Little River near Quincy exceeded the previous peak of 25,400 cfs which occurred on December 4, 1964. The peak discharge of 89,400 cfs at Ochlockonee River near Bloxham exceeded the April 1948 peak of 50,200 cfs, which was the previous maximum of record, by 1.8 times. Many flood-measurement sites had peak discharges in excess of that of a 50-year flood. Nearly $200,000 was spent on emergency repairs to roads. An additional $520,000 in contractual work was required to replace four bridges that were destroyed. Agricultural losses were estimated at $1,000,000. (44 page document)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Floods occurred on streams in the vicinity of Perry, Taylor County, Florida, on June 9, 1957, as a result of heavy rains from atropical disturbance. Serious flooding occurred in Perry along Spring and Pimple creeks as outlined by the shaded area in figure 1, requiring the evacuation of about ZOO families from the lowland area. No loss of life was reported. The damages to residential and commercial properties were estimated at several million dollars. Most of the damage was confined to residential areas (fig. 2); however, several stores in the area were damaged by flood waters (fig. 3). This report presents data pertaining to the rainfall accompanying this storm and peak flows of Spring and Pimple creeks in Perry. It contains flood elevations at several points, and peak discharges of the two creeks flowing through Perry. The report also contains a discussion of the rainfall associated with the flood and a description of the general features of the flood. (PDF contains 16 pages.)