897 resultados para Agreement error


Relevância:

20.00% 20.00%

Publicador:

Resumo:

The effect of basis set superposition error (BSSE) on molecular complexes is analyzed. The BSSE causes artificial delocalizations which modify the first order electron density. The mechanism of this effect is assessed for the hydrogen fluoride dimer with several basis sets. The BSSE-corrected first-order electron density is obtained using the chemical Hamiltonian approach versions of the Roothaan and Kohn-Sham equations. The corrected densities are compared to uncorrected densities based on the charge density critical points. Contour difference maps between BSSE-corrected and uncorrected densities on the molecular plane are also plotted to gain insight into the effects of BSSE correction on the electron density

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The basis set superposition error-free second-order MØller-Plesset perturbation theory of intermolecular interactions was studied. The difficulties of the counterpoise (CP) correction in open-shell systems were also discussed. The calculations were performed by a program which was used for testing the new variants of the theory. It was shown that the CP correction for the diabatic surfaces should be preferred to the adiabatic ones

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Geometries, vibrational frequencies, and interaction energies of the CNH⋯O3 and HCCH⋯O3 complexes are calculated in a counterpoise-corrected (CP-corrected) potential-energy surface (PES) that corrects for the basis set superposition error (BSSE). Ab initio calculations are performed at the Hartree-Fock (HF) and second-order Møller-Plesset (MP2) levels, using the 6-31G(d,p) and D95++(d,p) basis sets. Interaction energies are presented including corrections for zero-point vibrational energy (ZPVE) and thermal correction to enthalpy at 298 K. The CP-corrected and conventional PES are compared; the unconnected PES obtained using the larger basis set including diffuse functions exhibits a double well shape, whereas use of the 6-31G(d,p) basis set leads to a flat single-well profile. The CP-corrected PES has always a multiple-well shape. In particular, it is shown that the CP-corrected PES using the smaller basis set is qualitatively analogous to that obtained with the larger basis sets, so the CP method becomes useful to correctly describe large systems, where the use of small basis sets may be necessary

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We describe a simple method to automate the geometric optimization of molecular orbital calculations of supermolecules on potential surfaces that are corrected for basis set superposition error using the counterpoise (CP) method. This method is applied to the H-bonding complexes HF/HCN, HF/H2O, and HCCH/H2O using the 6-31G(d,p) and D95 + + (d,p) basis sets at both the Hartree-Fock and second-order Møller-Plesset levels. We report the interaction energies, geometries, and vibrational frequencies of these complexes on the CP-optimized surfaces; and compare them with similar values calculated using traditional methods, including the (more traditional) single point CP correction. Upon optimization on the CP-corrected surface, the interaction energies become more negative (before vibrational corrections) and the H-bonding stretching vibrations decrease in all cases. The extent of the effects vary from extremely small to quite large depending on the complex and the calculational method. The relative magnitudes of the vibrational corrections cannot be predicted from the H-bond stretching frequencies alone

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Recently, the surprising result that ab initio calculations on benzene and other planar arenes at correlated MP2, MP3, configuration interaction with singles and doubles (CISD), and coupled cluster with singles and doubles levels of theory using standard Pople’s basis sets yield nonplanar minima has been reported. The planar optimized structures turn out to be transition states presenting one or more large imaginary frequencies, whereas single-determinant-based methods lead to the expected planar minima and no imaginary frequencies. It has been suggested that such anomalous behavior can be originated by two-electron basis set incompleteness error. In this work, we show that the reported pitfalls can be interpreted in terms of intramolecular basis set superposition error (BSSE) effects, mostly between the C–H moieties constituting the arenes. We have carried out counterpoise-corrected optimizations and frequency calculations at the Hartree–Fock, B3LYP, MP2, and CISD levels of theory with several basis sets for a number of arenes. In all cases, correcting for intramolecular BSSE fixes the anomalous behavior of the correlated methods, whereas no significant differences are observed in the single-determinant case. Consequently, all systems studied are planar at all levels of theory. The effect of different intramolecular fragment definitions and the particular case of charged species, namely, cyclopentadienyl and indenyl anions, respectively, are also discussed

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The clinical demand for a device to monitor Blood Pressure (BP) in ambulatory scenarios with minimal use of inflation cuffs is increasing. Based on the so-called Pulse Wave Velocity (PWV) principle, this paper introduces and evaluates a novel concept of BP monitor that can be fully integrated within a chest sensor. After a preliminary calibration, the sensor provides non-occlusive beat-by-beat estimations of Mean Arterial Pressure (MAP) by measuring the Pulse Transit Time (PTT) of arterial pressure pulses travelling from the ascending aorta towards the subcutaneous vasculature of the chest. In a cohort of 15 healthy male subjects, a total of 462 simultaneous readings consisting of reference MAP and chest PTT were acquired. Each subject was recorded at three different days: D, D+3 and D+14. Overall, the implemented protocol induced MAP values to range from 80 ± 6 mmHg in baseline, to 107 ± 9 mmHg during isometric handgrip maneuvers. Agreement between reference and chest-sensor MAP values was tested by using intraclass correlation coefficient (ICC = 0.78) and Bland-Altman analysis (mean error = 0.7 mmHg, standard deviation = 5.1 mmHg). The cumulative percentage of MAP values provided by the chest sensor falling within a range of ±5 mmHg compared to reference MAP readings was of 70%, within ±10 mmHg was of 91%, and within ±15mmHg was of 98%. These results point at the fact that the chest sensor complies with the British Hypertension Society (BHS) requirements of Grade A BP monitors, when applied to MAP readings. Grade A performance was maintained even two weeks after having performed the initial subject-dependent calibration. In conclusion, this paper introduces a sensor and a calibration strategy to perform MAP measurements at the chest. The encouraging performance of the presented technique paves the way towards an ambulatory-compliant, continuous and non-occlusive BP monitoring system.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In vivo dosimetry is a way to verify the radiation dose delivered to the patient in measuring the dose generally during the first fraction of the treatment. It is the only dose delivery control based on a measurement performed during the treatment. In today's radiotherapy practice, the dose delivered to the patient is planned using 3D dose calculation algorithms and volumetric images representing the patient. Due to the high accuracy and precision necessary in radiation treatments, national and international organisations like ICRU and AAPM recommend the use of in vivo dosimetry. It is also mandatory in some countries like France. Various in vivo dosimetry methods have been developed during the past years. These methods are point-, line-, plane- or 3D dose controls. A 3D in vivo dosimetry provides the most information about the dose delivered to the patient, with respect to ID and 2D methods. However, to our knowledge, it is generally not routinely applied to patient treatments yet. The aim of this PhD thesis was to determine whether it is possible to reconstruct the 3D delivered dose using transmitted beam measurements in the context of narrow beams. An iterative dose reconstruction method has been described and implemented. The iterative algorithm includes a simple 3D dose calculation algorithm based on the convolution/superposition principle. The methodology was applied to narrow beams produced by a conventional 6 MV linac. The transmitted dose was measured using an array of ion chambers, as to simulate the linear nature of a tomotherapy detector. We showed that the iterative algorithm converges quickly and reconstructs the dose within a good agreement (at least 3% / 3 mm locally), which is inside the 5% recommended by the ICRU. Moreover it was demonstrated on phantom measurements that the proposed method allows us detecting some set-up errors and interfraction geometry modifications. We also have discussed the limitations of the 3D dose reconstruction for dose delivery error detection. Afterwards, stability tests of the tomotherapy MVCT built-in onboard detector was performed in order to evaluate if such a detector is suitable for 3D in-vivo dosimetry. The detector showed stability on short and long terms comparable to other imaging devices as the EPIDs, also used for in vivo dosimetry. Subsequently, a methodology for the dose reconstruction using the tomotherapy MVCT detector is proposed in the context of static irradiations. This manuscript is composed of two articles and a script providing further information related to this work. In the latter, the first chapter introduces the state-of-the-art of in vivo dosimetry and adaptive radiotherapy, and explains why we are interested in performing 3D dose reconstructions. In chapter 2 a dose calculation algorithm implemented for this work is reviewed with a detailed description of the physical parameters needed for calculating 3D absorbed dose distributions. The tomotherapy MVCT detector used for transit measurements and its characteristics are described in chapter 3. Chapter 4 contains a first article entitled '3D dose reconstruction for narrow beams using ion chamber array measurements', which describes the dose reconstruction method and presents tests of the methodology on phantoms irradiated with 6 MV narrow photon beams. Chapter 5 contains a second article 'Stability of the Helical TomoTherapy HiArt II detector for treatment beam irradiations. A dose reconstruction process specific to the use of the tomotherapy MVCT detector is presented in chapter 6. A discussion and perspectives of the PhD thesis are presented in chapter 7, followed by a conclusion in chapter 8. The tomotherapy treatment device is described in appendix 1 and an overview of 3D conformai- and intensity modulated radiotherapy is presented in appendix 2. - La dosimétrie in vivo est une technique utilisée pour vérifier la dose délivrée au patient en faisant une mesure, généralement pendant la première séance du traitement. Il s'agit de la seule technique de contrôle de la dose délivrée basée sur une mesure réalisée durant l'irradiation du patient. La dose au patient est calculée au moyen d'algorithmes 3D utilisant des images volumétriques du patient. En raison de la haute précision nécessaire lors des traitements de radiothérapie, des organismes nationaux et internationaux tels que l'ICRU et l'AAPM recommandent l'utilisation de la dosimétrie in vivo, qui est devenue obligatoire dans certains pays dont la France. Diverses méthodes de dosimétrie in vivo existent. Elles peuvent être classées en dosimétrie ponctuelle, planaire ou tridimensionnelle. La dosimétrie 3D est celle qui fournit le plus d'information sur la dose délivrée. Cependant, à notre connaissance, elle n'est généralement pas appliquée dans la routine clinique. Le but de cette recherche était de déterminer s'il est possible de reconstruire la dose 3D délivrée en se basant sur des mesures de la dose transmise, dans le contexte des faisceaux étroits. Une méthode itérative de reconstruction de la dose a été décrite et implémentée. L'algorithme itératif contient un algorithme simple basé sur le principe de convolution/superposition pour le calcul de la dose. La dose transmise a été mesurée à l'aide d'une série de chambres à ionisations alignées afin de simuler la nature linéaire du détecteur de la tomothérapie. Nous avons montré que l'algorithme itératif converge rapidement et qu'il permet de reconstruire la dose délivrée avec une bonne précision (au moins 3 % localement / 3 mm). De plus, nous avons démontré que cette méthode permet de détecter certaines erreurs de positionnement du patient, ainsi que des modifications géométriques qui peuvent subvenir entre les séances de traitement. Nous avons discuté les limites de cette méthode pour la détection de certaines erreurs d'irradiation. Par la suite, des tests de stabilité du détecteur MVCT intégré à la tomothérapie ont été effectués, dans le but de déterminer si ce dernier peut être utilisé pour la dosimétrie in vivo. Ce détecteur a démontré une stabilité à court et à long terme comparable à d'autres détecteurs tels que les EPIDs également utilisés pour l'imagerie et la dosimétrie in vivo. Pour finir, une adaptation de la méthode de reconstruction de la dose a été proposée afin de pouvoir l'implémenter sur une installation de tomothérapie. Ce manuscrit est composé de deux articles et d'un script contenant des informations supplémentaires sur ce travail. Dans ce dernier, le premier chapitre introduit l'état de l'art de la dosimétrie in vivo et de la radiothérapie adaptative, et explique pourquoi nous nous intéressons à la reconstruction 3D de la dose délivrée. Dans le chapitre 2, l'algorithme 3D de calcul de dose implémenté pour ce travail est décrit, ainsi que les paramètres physiques principaux nécessaires pour le calcul de dose. Les caractéristiques du détecteur MVCT de la tomothérapie utilisé pour les mesures de transit sont décrites dans le chapitre 3. Le chapitre 4 contient un premier article intitulé '3D dose reconstruction for narrow beams using ion chamber array measurements', qui décrit la méthode de reconstruction et présente des tests de la méthodologie sur des fantômes irradiés avec des faisceaux étroits. Le chapitre 5 contient un second article intitulé 'Stability of the Helical TomoTherapy HiArt II detector for treatment beam irradiations'. Un procédé de reconstruction de la dose spécifique pour l'utilisation du détecteur MVCT de la tomothérapie est présenté au chapitre 6. Une discussion et les perspectives de la thèse de doctorat sont présentées au chapitre 7, suivies par une conclusion au chapitre 8. Le concept de la tomothérapie est exposé dans l'annexe 1. Pour finir, la radiothérapie «informationnelle 3D et la radiothérapie par modulation d'intensité sont présentées dans l'annexe 2.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background: The COSMIN checklist is a tool for evaluating the methodological quality of studies on measurement properties of health-related patient-reported outcomes. The aim of this study is to determine the inter-rater agreement and reliability of each item score of the COSMIN checklist (n = 114). Methods: 75 articles evaluating measurement properties were randomly selected from the bibliographic database compiled by the Patient-Reported Outcome Measurement Group, Oxford, UK. Raters were asked to assess the methodological quality of three articles, using the COSMIN checklist. In a one-way design, percentage agreement and intraclass kappa coefficients or quadratic-weighted kappa coefficients were calculated for each item. Results: 88 raters participated. Of the 75 selected articles, 26 articles were rated by four to six participants, and 49 by two or three participants. Overall, percentage agreement was appropriate (68% was above 80% agreement), and the kappa coefficients for the COSMIN items were low (61% was below 0.40, 6% was above 0.75). Reasons for low inter-rater agreement were need for subjective judgement, and accustom to different standards, terminology and definitions.Conclusions: Results indicated that raters often choose the same response option, but that it is difficult on item level to distinguish between articles. When using the COSMIN checklist in a systematic review, we recommend getting some training and experience, completing it by two independent raters, and reaching consensus on one final rating. Instructions for using the checklist are improved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE: To evaluate accuracy and reproducibility of flow velocity and volume measurements in a phantom and in human coronary arteries using breathhold velocity-encoded (VE) MRI with spiral k-space sampling at 3 Tesla. MATERIALS AND METHODS: Flow velocity assessment was performed using VE MRI with spiral k-space sampling. Accuracy of VE MRI was tested in vitro at five constant flow rates. Reproducibility was investigated in 19 healthy subjects (mean age 25.4 +/- 1.2 years, 11 men) by repeated acquisition in the right coronary artery (RCA). RESULTS: MRI-measured flow rates correlated strongly with volumetric collection (Pearson correlation r = 0.99; P < 0.01). Due to limited sample resolution, VE MRI overestimated the flow rate by 47% on average when nonconstricted region-of-interest segmentation was used. Using constricted region-of-interest segmentation with lumen size equal to ground-truth luminal size, less than 13% error in flow rate was found. In vivo RCA flow velocity assessment was successful in 82% of the applied studies. High interscan, intra- and inter-observer agreement was found for almost all indices describing coronary flow velocity. Reproducibility for repeated acquisitions varied by less than 16% for peak velocity values and by less than 24% for flow volumes. CONCLUSION: 3T breathhold VE MRI with spiral k-space sampling enables accurate and reproducible assessment of RCA flow velocity.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose: To evaluate the suitability of an improved version of an automatic segmentation method based on geodesic active regions (GAR) for segmenting cerebral vasculature with aneurysms from 3D X-ray reconstruc-tion angiography (3DRA) and time of °ight magnetic resonance angiography (TOF-MRA) images available in the clinical routine.Methods: Three aspects of the GAR method have been improved: execution time, robustness to variability in imaging protocols and robustness to variability in image spatial resolutions. The improved GAR was retrospectively evaluated on images from patients containing intracranial aneurysms in the area of the Circle of Willis and imaged with two modalities: 3DRA and TOF-MRA. Images were obtained from two clinical centers, each using di®erent imaging equipment. Evaluation included qualitative and quantitative analyses ofthe segmentation results on 20 images from 10 patients. The gold standard was built from 660 cross-sections (33 per image) of vessels and aneurysms, manually measured by interventional neuroradiologists. GAR has also been compared to an interactive segmentation method: iso-intensity surface extraction (ISE). In addition, since patients had been imaged with the two modalities, we performed an inter-modality agreement analysis with respect to both the manual measurements and each of the two segmentation methods. Results: Both GAR and ISE di®ered from the gold standard within acceptable limits compared to the imaging resolution. GAR (ISE, respectively) had an average accuracy of 0.20 (0.24) mm for 3DRA and 0.27 (0.30) mm for TOF-MRA, and had a repeatability of 0.05 (0.20) mm. Compared to ISE, GAR had a lower qualitative error in the vessel region and a lower quantitative error in the aneurysm region. The repeatabilityof GAR was superior to manual measurements and ISE. The inter-modality agreement was similar between GAR and the manual measurements. Conclusions: The improved GAR method outperformed ISE qualitatively as well as quantitatively and is suitable for segmenting 3DRA and TOF-MRA images from clinical routine.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We investigate the problem of finding minimum-distortion policies for streaming delay-sensitive but distortion-tolerant data. We consider cross-layer approaches which exploit the coupling between presentation and transport layers. We make the natural assumption that the distortion function is convex and decreasing. We focus on a single source-destination pair and analytically find the optimum transmission policy when the transmission is done over an error-free channel. This optimum policy turns out to be independent of the exact form of the convex and decreasing distortion function. Then, for a packet-erasure channel, we analytically find the optimum open-loop transmission policy, which is also independent of the form of the convex distortion function. We then find computationally efficient closed-loop heuristic policies and show, through numerical evaluation, that they outperform the open-loop policy and have near optimal performance.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In the assessment of medical malpractice imaging methods can be used for the documentation of crucial morphological findings which are indicative for or against an iatrogenically caused injury. The clarification of deaths in this context can be usefully supported by postmortem imaging (primarily native computed tomography, angiography, magnetic resonance imaging). Postmortem imaging offers significant additional information compared to an autopsy in the detection of iatrogenic air embolisms and documentation of misplaced medical aids before dissection with an inherent danger of relocation. Additional information is supplied by postmortem imaging in the search for sources of bleeding as well as the documentation of perfusion after cardiovascular surgery. Key criteria for the decision to perform postmortem imaging can be obtained from the necessary preliminary inspection of clinical documentation.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Résumé Les glissements de terrain représentent un des principaux risques naturels dans les régions montagneuses. En Suisse, chaque année les glissements de terrains causent des dégâts qui affectent les infrastructures et ont des coûts financiers importants. Une bonne compréhension des mécanismes des glissements peut permettre d'atténuer leur impact. Celle-ci passe notamment par la connaissance de la structure interne du glissement, la détermination de son volume et de son ou ses plans de glissement. Dans un glissement de terrain, la désorganisation et la présence de fractures dans le matériel déplacé engendre un changement des paramètres physiques et en particulier une diminution des vitesses de propagation des ondes sismiques ainsi que de la densité du matériel. Les méthodes sismiques sont de ce fait bien adaptées à l'étude des glissements de terrain. Parmi les méthodes sismiques, l'analyse de la dispersion des ondes de surface est une méthode simple à mettre en oeuvre. Elle présente l'avantage d'estimer les variations des vitesses de cisaillement avec la profondeur sans avoir spécifiquement recours à l'utilisation d'une source d'onde S et de géophones horizontaux. Sa mise en oeuvre en trois étapes implique la mesure de la dispersion des ondes de surface sur des réseaux étendus, la détermination des courbes de dispersion pour finir par l'inversion de ces courbes. Les modèles de vitesse obtenus à partir de cette procédure ne sont valides que lorsque les milieux explorés ne présentent pas de variations latérales. En pratique cette hypothèse est rarement vérifiée, notamment pour un glissement de terrain dans lequel les couches remaniées sont susceptibles de présenter de fortes hétérogénéités latérales. Pour évaluer la possibilité de déterminer des courbes de dispersion à partir de réseaux de faible extension des mesures testes ont été effectuées sur un site (Arnex, VD) équipé d'un forage. Un profil sismique de 190 m de long a été implanté dans une vallée creusée dans du calcaire et remplie par des dépôts glacio-lacustres d'une trentaine de mètres d'épaisseur. Les données acquises le long de ce profil ont confirmé que la présence de variations latérales sous le réseau de géophones affecte l'allure des courbes de dispersion jusqu'à parfois empêcher leur détermination. Pour utiliser l'analyse de la dispersion des ondes de surface sur des sites présentant des variations latérales, notre approche consiste à déterminer les courbes de dispersions pour une série de réseaux de faible extension, à inverser chacune des courbes et à interpoler les différents modèles de vitesse obtenus. Le choix de la position ainsi que de l'extension des différents réseaux de géophones est important. Il tient compte de la localisation des hétérogénéités détectées à partir de l'analyse de sismique réfraction, mais également d'anomalies d'amplitudes observées sur des cartes qui représentent dans le domaine position de tir - position du récepteur, l'amplitude mesurée pour différentes fréquences. La procédure proposée par Lin et Lin (2007) s'est avérée être une méthode efficace permettant de déterminer des courbes de dispersion à partir de réseaux de faible extension. Elle consiste à construire à partir d'un réseau de géophones et de plusieurs positions de tir un enregistrement temps-déports qui tient compte d'une large gamme de distances source-récepteur. Au moment d'assembler les différentes données une correction de phase est appliquée pour tenir compte des hétérogénéités situées entre les différents points de tir. Pour évaluer cette correction nous suggérons de calculer pour deux tir successif la densité spectrale croisée des traces de même offset: Sur le site d'Arnex, 22 courbes de dispersions ont été déterminées pour de réseaux de géophones de 10 m d'extension. Nous avons également profité du forage pour acquérir un profil de sismique verticale en ondes S. Le modèle de vitesse S déduit de l'interprétation du profil de sismique verticale est utilisé comme information à priori lors l'inversion des différentes courbes de dispersion. Finalement, le modèle en deux dimension qui a été établi grâce à l'analyse de la dispersion des ondes de surface met en évidence une structure tabulaire à trois couches dont les limites coïncident bien avec les limites lithologiques observées dans le forage. Dans celui-ci des argiles limoneuses associées à une vitesse de propagation des ondes S de l'ordre de 175 m/s surmontent vers 9 m de profondeur des dépôts de moraine argilo-sableuse caractérisés par des vitesses de propagation des ondes S de l'ordre de 300 m/s jusqu'à 14 m de profondeur et supérieur ou égal à 400 m/s entre 14 et 20 m de profondeur. Le glissement de la Grande Combe (Ballaigues, VD) se produit à l'intérieur du remplissage quaternaire d'une combe creusée dans des calcaires Portlandien. Comme dans le cas du site d'Arnex les dépôts quaternaires correspondent à des dépôts glacio-lacustres. Dans la partie supérieure la surface de glissement a été localisée à une vingtaine de mètres de profondeur au niveau de l'interface qui sépare des dépôts de moraine jurassienne et des dépôts glacio-lacustres. Au pied du glissement 14 courbes de dispersions ont été déterminées sur des réseaux de 10 m d'extension le long d'un profil de 144 m. Les courbes obtenues sont discontinues et définies pour un domaine de fréquence de 7 à 35 Hz. Grâce à l'utilisation de distances source-récepteur entre 8 et 72 m, 2 à 4 modes de propagation ont été identifiés pour chacune des courbes. Lors de l'inversion des courbes de dispersion la prise en compte des différents modes de propagation a permis d'étendre la profondeur d'investigation jusqu'à une vingtaine de mètres de profondeur. Le modèle en deux dimensions permet de distinguer 4 couches (Vs1 < 175 m/s, 175 m/s < Vs2 < 225 m/s, 225 m/s < Vs3 < 400 m/s et Vs4 >.400 m/s) qui présentent des variations d'épaisseur. Des profils de sismiques réflexion en ondes S acquis avec une source construite dans le cadre de ce travail, complètent et corroborent le modèle établi à partir de l'analyse de la dispersion des ondes de surface. Un réflecteur localisé entre 5 et 10 m de profondeur et associé à une vitesse de sommation de 180 m/s souligne notamment la géométrie de l'interface qui sépare la deuxième de la troisième couche du modèle établi à partir de l'analyse de la dispersion des ondes de surface. Abstract Landslides are one of the main natural hazards in mountainous regions. In Switzerland, landslides cause damages every year that impact infrastructures and have important financial costs. In depth understanding of sliding mechanisms may help limiting their impact. In particular, this can be achieved through a better knowledge of the internal structure of the landslide, the determination of its volume and its sliding surface or surfaces In a landslide, the disorganization and the presence of fractures in the displaced material generate a change of the physical parameters and in particular a decrease of the seismic velocities and of the material density. Therefoe, seismic methods are well adapted to the study of landslides. Among seismic methods, surface-wave dispersion analysis is a easy to implement. Through it, shearwave velocity variations with depth can be estimated without having to resort to an S-wave source and to horizontal geophones. Its 3-step implementation implies measurement of surface-wave dispersion with long arrays, determination of the dispersion curves and finally inversion of these curves. Velocity models obtained through this approach are only valid when the investigated medium does not include lateral variations. In practice, this assumption is seldom correct, in particular for landslides in which reshaped layers likely include strong lateral heterogeneities. To assess the possibility of determining dispersion curves from short array lengths we carried out tests measurements on a site (Arnex, VD) that includes a borehole. A 190 m long seismic profile was acquired in a valley carved into limestone and filled with 30 m of glacio-lacustrine sediments. The data acquired along this profile confirmed that the presence of lateral variations under the geophone array influences the dispersion-curve shape so much that it sometimes preventes the dispersion curves determination. Our approach to use the analysis of surface-wave dispersion on sites that include lateral variations consists in obtaining dispersion curves for a series of short length arrays; inverting each so obtained curve and interpolating the different obtained velocity model. The choice of the location as well as the geophone array length is important. It takes into account the location of the heterogeneities that are revealed by the seismic refraction interpretation of the data but also, the location of signal amplitude anomalies observed on maps that represent, for a given frequency, the measured amplitude in the shot position - receiver position domain. The procedure proposed by Lin and Lin (2007) turned out to be an efficient one to determine dispersion curves using short extension arrays. It consists in building a time-offset from an array of geophones with a wide offset range by gathering seismograms acquired with different source-to-receiver offsets. When assembling the different data, a phase correction is applied in order to reduce static phase error induced by lateral variation. To evaluate this correction, we suggest to calculate, for two successive shots, the cross power spectral density of common offset traces. On the Arnex site, 22 curves were determined with 10m in length geophone-arrays. We also took advantage of the borehole to acquire a S-wave vertical seismic profile. The S-wave velocity depth model derived from the vertical seismic profile interpretation is used as prior information in the inversion of the dispersion-curves. Finally a 2D velocity model was established from the analysis of the different dispersion curves. It reveals a 3-layer structure in good agreement with the observed lithologies in the borehole. In it a clay layer with a shear-wave of 175 m/s shear-wave velocity overlies a clayey-sandy till layer at 9 m depth that is characterized down to 14 m by a 300 m/s S-wave velocity; these deposits have a S-wave velocity of 400 m/s between depths of 14 to 20 m. The La Grand Combe landslide (Ballaigues, VD) occurs inside the Quaternary filling of a valley carved into Portlandien limestone. As at the Arnex site, the Quaternary deposits correspond to glaciolacustrine sediments. In the upper part of the landslide, the sliding surface is located at a depth of about 20 m that coincides with the discontinuity between Jurassian till and glacio-lacustrine deposits. At the toe of the landslide, we defined 14 dispersion curves along a 144 m long profile using 10 m long geophone arrays. The obtained curves are discontinuous and defined within a frequency range of 7 to 35 Hz. The use of a wide range of offsets (from 8 to 72 m) enabled us to determine 2 to 4 mode of propagation for each dispersion curve. Taking these higher modes into consideration for dispersion curve inversion allowed us to reach an investigation depth of about 20 m. A four layer 2D model was derived (Vs1< 175 m/s, 175 m/s <Vs2< 225 m/s, 225 m/s < Vs3 < 400 m/s, Vs4> 400 m/s) with variable layer thicknesses. S-wave seismic reflection profiles acquired with a source built as part of this work complete and the velocity model revealed by surface-wave analysis. In particular, reflector at a depth of 5 to 10 m associated with a 180 m/s stacking velocity image the geometry of the discontinuity between the second and third layer of the model derived from the surface-wave dispersion analysis.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The first AO comprehensive pediatric long-bone fracture classification system has been proposed following a structured path of development and validation with experienced pediatric surgeons. A Web-based multicenter agreement study involving 70 surgeons in 15 clinics and 5 countries was conducted to assess the reliability and accuracy of this classification when used by a wide range of surgeons with various levels of experience. Training was provided at each clinic before the session. Using the Internet, participants could log in at any time and classify 275 supracondylar, radius, and tibia fractures at their own pace. The fracture diagnosis was made following the hierarchy of the classification system using both clinical terminology and codes. kappa coefficients for the single-surgeon diagnosis of epiphyseal, metaphyseal, or diaphyseal fracture type were 0.66, 0.80, and 0.91, respectively. Median accuracy estimates for each bone and type were all greater than 80%. Depending on their experience and specialization, surgeons greatly varied in their ability to classify fractures. Pediatric training and at least 2 years of experience were associated with significant improvement in reliability and accuracy. Kappa coefficients for diagnosis of specific child patterns were 0.51, 0.63, and 0.48 for epiphyseal, metaphyseal, and diaphyseal fractures, respectively. Identified reasons for coding discrepancies were related to different understandings of terminology and definitions, as well as poor quality radiographic images. Results supported some minor adjustments in the coding of fracture type and child patterns. This classification system received wide acceptance and support among the surgeons involved. As long as appropriate training could be performed, the system classification was reliable, especially among surgeons with a minimum of 2 years of clinical experience. We encourage broad-based consultation between surgeons' international societies and the use of this classification system in the context of clinical practice as well as prospectively for clinical studies.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Many complex systems may be described by not one but a number of complex networks mapped on each other in a multi-layer structure. Because of the interactions and dependencies between these layers, the state of a single layer does not necessarily reflect well the state of the entire system. In this paper we study the robustness of five examples of two-layer complex systems: three real-life data sets in the fields of communication (the Internet), transportation (the European railway system), and biology (the human brain), and two models based on random graphs. In order to cover the whole range of features specific to these systems, we focus on two extreme policies of system's response to failures, no rerouting and full rerouting. Our main finding is that multi-layer systems are much more vulnerable to errors and intentional attacks than they appear from a single layer perspective.