976 resultados para After-occupation evaluation


Relevância:

40.00% 40.00%

Publicador:

Resumo:

The object of the study was to compare two commercial root canal sealers: Ketac-Endo (a glass ionomer cement) and Fill Canal (a zinc oxide-eugenol cement). A total of 34 root canals from dog premolars with vital pulps were used. After instrumentation, the root canals were sealed with Ketac-Endo and Fill Canal cements using gutta-percha and a lateral condensation technique. After 270 days the animals were sacrificed with an anesthetic overdose and the maxillae and mandibles were removed and fixed in formalin for 48 h. After routine histological processing the sections were stained with hematoxylin-eosin and Mallory trichrome stains. Microscopic analysis revealed that Ketac-Endo cement presented better results than Fill Canal cement.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

CAUDA equina syndrome (CES) has long been recognized as a rare complication of spinal anesthesia.(1) CES has been described after administration of spinal anesthetics with lidocaine(2) and bupivacaine.(3) In 1991,(4) CES was reported after continuous spinal anesthesia with 1% tetracaine. In 1980, at our university hospital, six adult female patients underwent perineal gynecologic surgery using a spinal anesthetic of 2 ml tetracaine, 1.2%, in 10% glucose. The concentration of the injected tetracaine was unknown by the anesthetists. In all cases, lumbar puncture was performed at the L3-L4 interspace with a disposable spinal needle while the patients were in the sitting position. CES was first diagnosed 72 h or later postoperatively; previous diagnosis was not possible because patients had an indwelling urethral catheter. The diagnosis of CES was confirmed in all patients. During the past year, after institutional approval and informed consent, clinical, magnetic resonance imaging, electromyographic examinations, and conduction studies were performed in three of the above patients. Examinations were not possible on the other three patients because one had recently died, another could not be located, and the third refused to participate. T1 and T2 magnetic resonance image readings were obtained with Gadolinium contrast from a 0.5 Tesla General Electric apparatus (General Electric, Tokyo, Japan). Bilateral sensory and motor conduction studies of the sciatic nerve branches were obtained using a two-channel Nihon-Kohden Neuropack 2 (Nihom-Kohden Corporation, Tokyo, Japan). Electromyography was performed in accordance with conventional techniques.(5,6)

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Acid erosion is a superficial loss of enamel caused by chemical processes that do not involve bacteria. Intrinsic and extrinsic factors, such as the presence of acid substances in the oral cavity, may cause a pH reduction, thus potentially increasing acid erosion. The aim of this study was to evaluate the microhardness of bleached and unbleached bovine enamel after immersion in a soda beverage, artificial powder juice and hydrochloric acid. The results obtained for the variables of exposure time, acid solution and substrate condition (bleached or unbleached enamel) were statistically analyzed by the ANOVA and Tukey tests. It was concluded that a decrease in microhardness renders dental structures more susceptible to erosion and mineral loss, and that teeth left unbleached show higher values of microhardness compared to bleached teeth.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

This study evaluated the microleakage of pit and fissure sealants after different surface preparation (invasive technique and laser irradiation) and the use of different materials (fluoride resin-filled sealant, resin-modified glass ionomer cement and adhesive system). Eighty-four pre molars were used in this study, which were divided into seven groups. After the accomplishment of the different treatments, these were submitted to thermocycling process and assess for microleakage by examination under an epifluorescent microscope and scored zero to seven. Two specimens of each group were observed under scanning electron microscope (SEM). The results showed that laser irradiation did not lessen microleakage in pit and fissures when using a filled-resin sealant with fluoride or a resin-modified glass ionomer cement. The use of laser irradiation and adhesive system, followed by a resin-filled sealant with fluoride, showed the lowest microleakage scores in pit and fissures. Comparing this group to the resin-modified glass ionomer cement group, there was statistical significance. The use of a adhesive system decreased microleakage when using a fluoride resin-filled sealant with or without previous laser irradiation; although it was not statistically significant.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Eighty-four root canals of premolars from six dogs were left open for 7 days, and then sealed and followed for 45 days until periradicular periodontitis developed. The root canals were then treated endodontically using 5.25% sodium hypochlorite as the irrigating solution. After instrumentation, all root canals were filled with a calcium hydroxide-based antibacterial dressing (Calen PMCC or Calasept) that was left in place for 30 days. After this period the root canals were filled with gutta-percha cones and a root canal sealer (Sealapex or AH Plus)-group I: Calen PMCC + Sealapex; group II: Calasept + Sealapex; group III: Calen PMCC + AH Plus; and group IV: Calasept + AH Plus. Periapical radiographs of the teeth were made after root canal filling and after 90, 180, 270, and 360 days. Radiographic images were digitalized by scanning, and the Mocha program was used to measure the periapical lesions. Analysis showed that the lesions of groups I to III were statistically similar reduction in size, whereas group IV had a smaller reduction in lesion size (p < 0.05). Copyright © 2001 by The American Association of Endodontists.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Background: Previous experiments have shown that a decoction of Bauhinia forficata leaves reduces the changes in carbohydrate and protein metabolism that occur in rats with streptozotocin-induced diabetes. In the present investigation, the serum activities of enzymes known to be reliable toxicity markers were monitored in normal and streptozotocin-diabetic rats to discover whether the use of B. forficata decoction has toxic effects on liver, muscle or pancreas tissue or on renal microcirculation. Methods: An experimental group of normal and streptozotocin-diabetic rats received an aqueous decoction of fresh B. forficata leaves (150 g/L) by mouth for 33 days while a control group of normal and diabetic rats received water for the same length of time. The serum activity of the toxicity markers lactate dehydrogenase, creatine kinase, amylase, angiotensin-converting enzyme and bilirubin were assayed before receiving B. forficata decoction and on day 19 and 33 of treatment. Results: The toxicity markers in normal and diabetic rats were not altered by the diabetes itself nor by treatment with decoction. Whether or not they received B. forficata decoction the normal rats showed a significant increase in serum amylase activity during the experimental period while there was a tendency for the diabetic rats, both treated and untreated with decoction, to have lower serum amylase activities than the normal rats. Conclusions: Administration of an aqueous decoction of B. forficata is a potential treatment for diabetes and does not produce toxic effects measurable with the enzyme markers used in our study. © 2004 Pepato et al; licensee BioMed Central Ltd.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

OBJECTIVE: This study evaluated the efficiency of repolishing, sealing with surface sealant, and the joining of both in decreasing the surface roughness of resin-based composites after a toothbrushing process. METHOD AND MATERIALS: Ten specimens of each composite (Alert, Z100, Definite, and Prodigy Condensable), measuring 2 mm in thickness and 4 mm in diameter, were made and submitted to finishing and polishing processes on both sides of the specimens using the Sof-Lex system. The specimens were then subjected to toothbrushing (30,000 cycles), and surface roughness (Ra) was analyzed with a Surfcorder SE 1700 profilometer. The upper surface of each composite was etched with 37% phosphoric acid, and the surface-penetrating sealant Protect-it was applied on 1 surface. The roughness of these surfaces was again measured. On the other side, the surface of the specimen was repolished, and the efficiency of this procedure was measured using the profilometer. The surface roughness resulting from the joining of the 2 methods was verified by applying, in the final stage, the surface-penetrating sealant on the repolished surface. Data were analyzed with analysis of variance and Tukey test (P <.05). RESULTS: Results showed that the lowest surface roughness values were obtained for Definite, Z100, and Prodigy Condensable after the repolishing process and after the repolishing plus sealing. For Alert, the joining of repolishing plus sealing promoted the lowest values of surface roughness. CONCLUSION: Of the resin-based composites, Alert demonstrated the highest values of surface roughness in all the techniques tested.