898 resultados para ANODIC-STRIPPING VOLTAMMETRY
Resumo:
Pós-graduação em Química - IQ
Resumo:
Pós-graduação em Química - IQ
Resumo:
Pós-graduação em Química - IQ
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
A new selective sensor based on molecularly imprinted polymers (MIPs) was developed for the determination of hexazinone (HXZ) in environmental samples. MIPs were synthesized using a non-covalent approach, and selection of the monomers employed in the polymerization reaction was carried out by molecular modeling. Three functional monomers with high (2-vinylpyridine (MP17)) and intermediate (methacrylic acid (MP12) and acrylamide (MP5)) energies of binding to the template (HXZ) were selected for preparation of the MIPs, in order to conduct comparative studies and validate the theoretical data. For sensor construction, carbon pastes were modified with each MIP or NIP (non-imprinted polymer), and HXZ determination was performed using differential pulse adsorptive cathodic stripping voltammetry (DPAdCSV). All parameters affecting the sensor response were optimized. In HCl at pH 2.5, the sensor prepared with MP17 (5% w/w in the paste) showed a dynamic linear range between 1.9 × 10−11 and 1.1 × 10−10 mol L−1, and a detection limit of 2.6 × 10−12 mol L−1, under the following conditions: accumulation time of 200 s at a potential of −0.5V, scan rate of 50 mVs−1, pulse amplitude of 60 mV, and pulse width of 50 ms. The sensor was selective in the presence of other similar compounds, and was successfully applied to the analysis of HXZ in river water samples.
Resumo:
Pós-graduação em Química - IBILCE
Resumo:
This paper describes the applicability of a Hg-electroplated-Pt ultramicroelectrode in the quantification of elemental sulphur in naphtha samples by square-wave voltammetry. A reproducible deposition methodology was studied and is reported in this paper. This methodology is innovative and relies on the quality of the mercury stock solution to obtain reproducible surfaces required for the analytical methodology. All analyses were performed using a Hg-electroplated-Pt ultramicroelectrode (Hg-Pt UME) due to the low sensibility of such devices to ohmic drops in resistive solutions. The responses of the peak areas in voltammetric experiments were linear in all of the range studied. The method developed here is accurate and reproducible, with a detection limit of 0.010 mg L-1 and a good recovery range for both standard solutions of elemental sulphur (85 to 99%) and real naphtha sample (79%). These results attest to the potential for the application of this electroanalytical methodology in determining elemental sulphur in naphtha samples containing mercaptans and disulphides.
Resumo:
CHEMICAL AND PHYSICAL FACTORS INFLUENCING LEAD AND COPPER CONTAMINATION IN DRINKING WATER: APPROACH FOR A CASE STUDY IN ANALYTICAL CHEMISTRY. Lead and copper concentrations in drinking water increase considerably on going from municipality reservoirs to the households sampled in Ribeirao Preto (SP-Brazil). Flushing of only 3 liters of water reduced metal concentrations by more than 50%. Relatively small changes in water pH rapidly affected corrosion processes in lead pipes, while water hardness appeared to have a long-term effect. This approach aims to encourage University teachers to use its content as a case study in disciplines of Instrumental Analytical Chemistry and consequently increase knowledge about drinking water contamination in locations where no public monitoring of trace metals is in place.
Resumo:
Lead and copper concentrations in drinking water increase considerably on going from municipality reservoirs to the households sampled in Ribeirão Preto (SP-Brazil). Flushing of only 3 liters of water reduced metal concentrations by more than 50%. Relatively small changes in water pH rapidly affected corrosion processes in lead pipes, while water hardness appeared to have a long-term effect. This approach aims to encourage University teachers to use its content as a case study in disciplines of Instrumental Analytical Chemistry and consequently increase knowledge about drinking water contamination in locations where no public monitoring of trace metals is in place.
Resumo:
Esta tesis presenta los resultados de la investigación realizada sobre la inertización de cenizas volantes procedentes de residuos sólidos urbanos y su posterior encapsulación en distintas matrices de mortero. Durante el proceso de inertización, se ha logrado la inertización de éste residuo tóxico y peligroso (RTP) y también su valorización como subproducto. De esta forma se dispone de nueva “materia prima” a bajo coste y la eliminación de un residuo tóxico y peligroso con la consiguiente conservación de recursos naturales alternativos. La caracterización química de las cenizas analizadas refleja que éstas presentan altas concentraciones de cloruros, Zn y Pb. Durante la investigación se ha desarrollado un proceso de inertización de las cenizas volantes con bicarbonato sódico (NaHCO3) que reduce en un 99% el contenido en cloruros y mantiene el pH en valores óptimos para que la concentración de los metales pesados en el lixiviado sea mínima debido a su estabilización en forma de carbonatos insolubles. Se han elaborado morteros con cuatro tipos distintos de cementos (CEM-I, CEM-II, CAC y CSA) incorporando cenizas volantes inertizadas en una proporción igual a un 10% en peso del árido utilizado. Los morteros ensayados abarcan distintas dosificaciones tanto en la utilización de áridos con distintos diámetros (0/2 y 0/4), como en la relación cemento/árido (1/1 y 1/3). Se han obtenido las propiedades físicas y mecánicas de estos morteros mediante ensayos de Trabajabilidad, Estabilidad Dimensional, Carbonatación, Porosidad y Resistencias Mecánicas. De igual forma, se presentan resultados de ensayos de lixiviación de Zn, Pb, Cu y Cd, sobre probetas monolíticas de los morteros con los mejores comportamientos físico/mecánicos, donde se ha analizado el contenido en iones de dichos metales pesados lixiviados mediante determinación voltamperométrica de redisolución anódica Se concluye que todos los morteros ensayados son técnicamente aceptables, siendo los más favorables los elaborados con Cemento de Sulfoaluminato de Calcio (CSA) y con Cemento de Aluminato de Calcio (CAC). En este último caso, se mejoran las resistencias a compresión de los morteros de referencia en más de un 48%, y las resistencias a flexión en más de un 67%. De igual forma, los ensayos de lixiviado revelan la completa encapsulación de los iones de Zn y la mitigación en el lixiviado de los iones de Pb. Ambos morteros podrían ser perfectamente validos en actuaciones en las que se necesitase un producto de fraguado rápido, altas resistencias iniciales y compensación de las retracciones con una elevada estabilidad dimensional. En base a esto, el material podría ser utilizado como mortero de reparación en viales y pavimentos que requiriesen altas prestaciones, tales como: soleras industriales, pistas de aterrizaje, aparcamientos, etc. O bien, para la confección de elementos prefabricados sin armaduras estructurales, dada su elevada resistencia a flexión. ABSTRACT This dissertation presents the results of a research on inerting fly ash from urban solid waste and its subsequent encapsulation in mortar matrixes. The inerting of this hazardous toxic waste, as well as its valorization as a by-product has been achieved. In this way, a new "raw material" is available through a simple process and the toxic and hazardous waste is eliminated, and consequently, conservation of alternative natural resources is strengthened. Chemical analysis of the ashes analyzed shows high concentrations of soluble chlorides, Zn and Pb. An inerting process of fly ash with sodium bicarbonate (NaHCO3) has been developed which reduces 99% the content of chlorides and maintains pH at optimal values, so that the concentration of heavy metals in the leachate is minimum, due to its stabilization in the form of insoluble carbonates. Mortars with four different types of cements (CEM-I, CEM-II, CAC and CSA) have been developed by the addition of inertized fly ash in the form of carbonates, in the proportion of 10% in weight of the aggregates used. The samples tested include different proportions in the use of aggregates with different sizes (0/2 and 0/4), and in the cement/aggregate ratio (1/1 and 1/3). Physical/mechanical properties of these mortars have been studied through workability, dimensional stability, carbonation, porosity and mechanic strength tests. Leaching tests of Zn, Pb, Cu and Cd ions are also being performed on monolithic samples of the best behavioral mortars. The content in leachated heavy metal ions is being analyzed through stripping voltammetry determination. Conclusions drawn are that the tested CAC and CSA cement mortars present much better behavior than those of CEM-I and CEM-II cement. The results are especially remarkable for the CAC cement mortars, improving reference mortars compression strengths in more than 48%, and also bending strengths in more than 67%. Leaching tests confirm that the encapsulation of Zn and Pb is achieved and leachate of both ions is mitigated within the mortar matrixes. For the above stated reasons, it might be concluded that mortars made with calcium aluminate cements or calcium sulfoaluminate with the incorporation of treated fly ash, may be perfectly valid for uses in which a fast-curing product, with high initial strength and drying shrinkage compensation with a high dimensional stability is required. Based on this, the material could be used as repair mortar for structures, roads and industrial pavements requiring high performance, such as: industrial floorings, landing tracks, parking lots, etc. Alternatively, it could also be used in the manufacture of prefabricated elements without structural reinforcement, given its high bending strength.
Resumo:
Heavy metals are present in industrial waste. These metals can generate a large environmental impact contaminating water, soil and plants. The chemical action of heavy metals has attracted environmental interest. In this context, this study aimed to test t he performance of electrochemical technologies for removing and quantifying heavy metals. First ly , the electroanalytical technique of stripping voltammetry with glassy carbon electrode (GC) was standardized in order to use this method for the quantificatio n of metals during their removal by electrocoagulation process (EC). A nalytical curves were evaluated to obtain reliability of the determin ation and quantification of Cd 2+ and Pb 2+ separately or in a mixture. Meanwhile , EC process was developed using an el ectrochemical cell in a continuous flow (EFC) for removing Pb 2+ and Cd 2+ . The se experiments were performed using Al parallel plates with 10 cm of diameter ( 63.5 cm 2 ) . The optimization of conditions for removing Pb 2+ and Cd 2+ , dissolved in 2 L of solution at 151 L h - 1 , were studied by applying different values of current for 30 min. Cd 2+ and Pb 2+ concentrations were monitored during electrolysis using stripping voltammetry. The results showed that the removal of Pb 2 + was effective when the EC pro cess is used, obtaining removals of 98% in 30 min. This behavior is dependent on the applied current, which implies an increase in power consumption. From the results also verified that the stripping voltammetry technique is quite reliable deter mining Pb 2+ concentration , when compared with the measurements obtained by atomic absorption method (AA). In view of this, t he second objective of this study was to evaluate the removal of Cd 2+ and Pb 2+ (mixture solution) by EC . Removal efficiency increasing current was confirmed when 93% and 100% of Cd 2+ and Pb 2+ was removed after 30 min . The increase in the current promotes the oxidation of sacrificial electrodes, and consequently increased amount of coagulant, which influences the removal of heavy metals in solution. Adsortive voltammetry is a fast, reliable, economical and simple way to determine Cd 2+ and Pb 2+ during their removal. I t is more economical than those normally used, which require the use of toxic and expensive reagents. Our results demonstrated the potential use of electroanalytical techniques to monitor the course of environmental interventions. Thus, the application of the two techniques associated can be a reliable way to monitor environmental impacts due to the pollution of aquatic ecosystems by heavy metals.
Resumo:
Hexavalent chromium is a heavy metal present in various industrial effluents, and depending on its concentration may cause irreparable damage to the environment and to humans. Facing this surrounding context, this study aimed on the application of electrochemical methods to determine and remove the hexavalent chromium (Cr6+) in simulated wastewater. To determine was applied to cathodic stripping voltammetry (CSV) using ultra trace graphite electrodes ultra trace (work), Ag/AgCl (reference) and platinum (counter electrode), the samples were complexed with 1,5- diphenylcarbazide and then subjected to analysis. The removal of Cr6+ was applied electrocoagulation process (EC) using Fe and Al electrodes. The variables that constituted the factorial design 24, applied to optimizing the EC process, were: current density (5 and 10 mA.cm-2), temperature (25 and 60 ºC), concentration (50 and 100 ppm) and agitation rate (400 and 600 RPM). Through the preliminary test it was possible the adequacy of applying the CSV for determining of Cr6+, removed during the EC process. The Fe and Al electrodes as anodes sacrifice showed satisfactory results in the EC process, however Fe favored complete removal in 30 min, whereas with Al occurred at 240 min. In the application of factorial design 24 and analysis of Response Surface Methodology was possible to optimize the EC process for removal of Cr6+ in H2SO4 solution (0.5 mol.L-1), in which the temperature, with positive effect, was the variable that presented higher statistical significance compared with other variables and interactions, while in optimizing the EC process for removal of Cr6+ in NaCl solution (0.1 mol.L-1) the current density, with positive effect, and concentration, with a negative effect were the variables that had greater statistical significance with greater statistical significance compared with other variables and interactions. The utilization of electrolytes supports NaCl and Na2SO4 showed no significant differences, however NaCl resulted in rapid improvement in Cr6+ removal kinetics and increasing the NaCl concentration provided an increase in conductivity of the solution, resulting in lower energy consumption. The wear of the electrodes evaluated in all the process of EC showed that the Al in H2SO4 solution (0.5 mol.L-1), undergoes during the process of anodization CE, then the experimental mass loss is less than the theoretical mass loss, however, the Fe in the same medium showed a loss of mass greater experimental estimated theoretically. This fact is due to a spontaneous reaction of Fe with H2SO4, and when the reaction medium was the NaCl and Na2SO4 loss experimental mass approached the theoretical mass loss. Furthermore, it was observed the energy consumption of all processes involved in this study had a low operating cost, thus enabling the application of the EC process for treating industrial effluents. The results were satisfactory, it was achieved complete removal of Cr6+ in all processes used in this study.
Resumo:
Hydrothermal vent fluids are highly enriched in iron (Fe) compared to ambient seawater, and organic ligands may play a role in facilitating the transport of some hydrothermal Fe into the open ocean. This is important since Fe is a limiting micronutrient for primary production in large parts of the world's surface ocean. We have investigated the concentration and speciation of Fe in several vent fluid and plume samples from the Nifonea vent field, Coriolis Troughs, New Hebrides Island Arc, South Pacific Ocean using competitive ligand exchange-adsorptive cathodic stripping voltammetry (CLE-AdCSV) with salicylaldoxime (SA) as the artificial ligand. Our results for total dissolved Fe (dFe) in the buoyant hydrothermal plume samples showed concentrations up to 3.86 µM dFe with only a small fraction between 1.1 and 11.8% being chemically labile. Iron binding ligand concentrations ([L]) were found in µM level with strong conditional stability constants up to logKFeL,Fe3+ of 22.9. Within the non-buoyant hydrothermal plume above the Nifonea vent field, up to 84.7% of the available Fe is chemically labile and [L] concentrations up to 97 nM were measured. [L] was consistently in excess of Felab, indicating that all available Fe is being complexed, which in combination with high Felab values in the non-buoyant plume, signifies that a high fraction of hydrothermal dFe is potentially being transported away from the plume into the surrounding waters, contributing to the global oceanic Fe budget.
Resumo:
Os sedimentos podem atuar tanto como acumuladores quanto como fontes de poluentes. Em função das atividades portuárias locais estarem em ritmo de crescimento pela ampliação do porto de Rio Grande (RS), estudos que mostrem a situação do local investigado são importantes a fim de prever o aporte do ferro nesse ambiente. Neste trabalho, a especiação química do ferro e a determinação da concentração do metal total e dissolvido em amostras de águas intersticiais no sedimento do Saco do Mendanha (RS) foram avaliadas, utilizando a Voltametria Adsortiva de Redissolução Catódica com o ligante 2,3-Dihidroxinaftaleno. O objetivo principal desse trabalho foi validar a metodologia analítica para realizar a especiação química do ferro em águas intersticiais, o que englobou a faixa linear de trabalho, limites de detecção e de quantificação, a exatidão e precisão. O Limite de Detecção encontrado foi de 0,11 nmol L-1 . Foram determinadas as concentrações de ferro total, dissolvido e lábil em três frações distintas: na interface água/sedimento, entre 0 e -5 cm; e entre -15 e -20 cm de profundidade na coluna sedimentar. Nas amostras analisadas, a concentração de ferro lábil encontrada foi entre 4,64 – 135,37 µmol L-1 ; a concentração do metal dissolvido foi de 6,25 – 322,70 µmol L-1 e de ferro total entre 83,36 – 390,30 µmol L-1 . A concentração do metal lábil em comparação com a fração dissolvida e total indica a presença de complexos estáveis entre o metal e a matéria orgânica natural presente na água intersticial, tornando dessa forma, o metal menos biodisponível para a biota local. Durante os meses de amostragem do sedimento, foi observada variação da concentração do metal, onde no mês de abril ocorreu o maior aporte do metal da coluna d’água para o sedimento. Essa transferência do metal para o sedimento pode estar relacionada pela forte mudança na salinidade no local de amostragem, passando de 16 no mês de fevereiro para 33 no mês de abril e para próximo de zero nos meses de agosto e novembro de 2009.