1000 resultados para 331.13


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background and Aims: To protect the population from environmental tobacco smoke (ETS) Switzerland introduced a nationwide rather heterogeneous smoking ban in May 2010. The exposure situation of non-smoking hospitality workers before and after implementation of the new law is being assessed in a prospective cohort study. Methods: Exposure to ETS was measured using a novel method developed by the Institute for Work and Health in Lausanne. It is a passive sampler called MoNIC (Monitor of NICotine). The nicotine of the ETS is fixed onto a filter and transformed into salt of not volatile nicotine. Subsequently the number of passively smoked cigarettes is calculated. Badges were placed at the workplace as well as distributed to the participants for personal measuring. Additionally a salivary sample was taken to determine nicotine concentration. Results: At baseline Spearman's correlation between workplace and personal badge was 0.47. The average cigarette equivalents per day at the workplace obtained by badge significantly dropped from 5.1 (95%- CI: 2.4 to 7.9) at baseline to 0.3 (0.2 to 0.4) at first follow-up (n=29) three months later (p<0.001). For personal badges the number of passively smoked cigarettes declined from 1.5 (2.7 to 0.4) per day to 0.5 (0.3 to 0.8) (n=16).Salivary nicotine concentration in a subset of 13 participants who had worked on the day prior to the examination was 2.63 ng/ml before and 1.53 ng/ml after the ban (p=0.04). Spearman's correlation of salivary nicotine was 0.56 with workplace badge and 0.79 with personal badge concentrations. Conclusions: Workplace measurements clearly reflect the smoking regulation in a venue. The MoNIC badge proves to be a sensitive measuring device to determine personal ETS exposure and it is a demonstrative measure for communication with lay audiences and study participants as the number of passively smoked cigarettes is an easily conceivable result.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE: To evaluate the effect of vouchers for maternity care in public health-care facilities on the utilization of maternal health-care services in Cambodia. METHODS: The study involved data from the 2010 Cambodian Demographic and Health Survey, which covered births between 2005 and 2010. The effect of voucher schemes, first implemented in 2007, on the utilization of maternal health-care services was quantified using a difference-in-differences method that compared changes in utilization in districts with voucher schemes with changes in districts without them. FINDINGS: Overall, voucher schemes were associated with an increase of 10.1 percentage points (pp) in the probability of delivery in a public health-care facility; among women from the poorest 40% of households, the increase was 15.6 pp. Vouchers were responsible for about one fifth of the increase observed in institutional deliveries in districts with schemes. Universal voucher schemes had a larger effect on the probability of delivery in a public facility than schemes targeting the poorest women. Both types of schemes increased the probability of receiving postnatal care, but the increase was significant only for non-poor women. Universal, but not targeted, voucher schemes significantly increased the probability of receiving antenatal care. CONCLUSION: Voucher schemes increased deliveries in health centres and, to a lesser extent, improved antenatal and postnatal care. However, schemes that targeted poorer women did not appear to be efficient since these women were more likely than less poor women to be encouraged to give birth in a public health-care facility, even with universal voucher schemes.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Información elaborada a partir de: Proyecto de Humanización de la Atención Perinatal en Andalucía; Plan para la Promoción de la Actividad Física y la Alimentación Equilibrada; Plan Integral de Obesidad Infantil de Andalucía; Programas de Promoción de Salud Bucodental "Sonrisitas" y "Aprende a sonreir"; Plan Integral de Atención a la Accidentabilidad de Andalucía; Plan Integral de Tabaquismo de Andalucía; Plan Integral de Oncología de Andalucía. Publicado en el Portal Web de Ventana Abierta a la familia: www.juntadeandalucia.es/salud/ventanafamilias

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Référence bibliographique : Rol, 54895

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Boletín semanal para profesionales sanitarios de la Secretaría General de Calidad, Innovación y Salud Pública de la Consejería de Igualdad, Salud y Políticas Sociales

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND/OBJECTIVES: (1) To cross-validate tetra- (4-BIA) and octopolar (8-BIA) bioelectrical impedance analysis vs dual-energy X-ray absorptiometry (DXA) for the assessment of total and appendicular body composition and (2) to evaluate the accuracy of external 4-BIA algorithms for the prediction of total body composition, in a representative sample of Swiss children. SUBJECTS/METHODS: A representative sample of 333 Swiss children aged 6-13 years from the Kinder-Sportstudie (KISS) (ISRCTN15360785). Whole-body fat-free mass (FFM) and appendicular lean tissue mass were measured with DXA. Body resistance (R) was measured at 50 kHz with 4-BIA and segmental body resistance at 5, 50, 250 and 500 kHz with 8-BIA. The resistance index (RI) was calculated as height(2)/R. Selection of predictors (gender, age, weight, RI4 and RI8) for BIA algorithms was performed using bootstrapped stepwise linear regression on 1000 samples. We calculated 95% confidence intervals (CI) of regression coefficients and measures of model fit using bootstrap analysis. Limits of agreement were used as measures of interchangeability of BIA with DXA. RESULTS: 8-BIA was more accurate than 4-BIA for the assessment of FFM (root mean square error (RMSE)=0.90 (95% CI 0.82-0.98) vs 1.12 kg (1.01-1.24); limits of agreement 1.80 to -1.80 kg vs 2.24 to -2.24 kg). 8-BIA also gave accurate estimates of appendicular body composition, with RMSE < or = 0.10 kg for arms and < or = 0.24 kg for legs. All external 4-BIA algorithms performed poorly with substantial negative proportional bias (r> or = 0.48, P<0.001). CONCLUSIONS: In a representative sample of young Swiss children (1) 8-BIA was superior to 4-BIA for the prediction of FFM, (2) external 4-BIA algorithms gave biased predictions of FFM and (3) 8-BIA was an accurate predictor of segmental body composition.