960 resultados para 3.4-benzpyrene


Relevância:

100.00% 100.00%

Publicador:

Resumo:

New thermoplastic polyimide (PEI) composites based on 1,4-(3,4-discarboxyphenoxyl)benzene/4,4'- methylene dianiline have been fabricated by the approach of polymerization by the approach of polymerization of monomer reactants (PMR). The chemical and physical behavior of the resin during processing are determined by infrared spectroscopy and rheology. The influence of processing conditions on the composite properties is investigated. The processing, physical and mechanical properties of the composites reinforced with different fibers are presented.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Gas permeability coefficients of a series of aromatic polyetherimides prepared from 1,4-bis(3,4-dicarboxyphenoxy) benzene dianhydride (HQDPA) and four (methylene dianiline)s with a methyl side group to H-2, CO2, O-2, N-2, and CH4 were measured under 7 atm and within a temperature range from 30 to 150 degrees C. The gas permeabilities and permselectivities of these polymers were compared with those of the HQDPA-based polyetherimides from methylene dianiline (MDA) and isopropylidene dianiline (IPDA). The number and position of the methyl side groups on the benzene rings of the diamine residues strongly affect the gas permeabilities and permselectivities of the HQDPA-based polyetherimides. The gas permeability of the polyetherimide progressively increases with an increase in the number of the methyl side groups. Both the gas permeability and permselectivity of the polyetherimides with methyl side groups are higher than those of HQDPA-MDA. The polyetherimide prepared from 3,3'-dimethyl 4,4'-methylene dianiline (DMMDA1) possesses both higher permeability and permselectivity than the polyetherimides prepared from 2,2'-dimethyl 4,4'-methylene dianiline (DMMDA2). However, two of the polyetherimides prepared 2,2',3,3'-tetramethyl 4,4'-methylene dianiline (TMMDA1) or 2,2', 5,5'-tetramethyl 4,4'-methylene dianiline (TMMDA2) possess almost the same gas permeability and permselectivity.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

采用WAXD、SAXS和X-射线平板照相法研究了不同聚合条件和拉伸倍数下的晶性3,4-聚异戊二烯的结构.结果发现,降低催化体系反应速度有利于产物结晶;不同的含氮类给电子试剂对聚合物的结晶结构影响较大.取向样品随着拉伸倍数的增加结晶度和长周期增大,微晶尺寸变小.SAXS的散射强度计算表明,该聚合物属多分散非均一粒子体系,微孔半径在3.5-16.4nm间.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The title complex was synthesized and characterized by H-1, C-13, Sn-119 NMR and IR spectra. A single crystal X-ray diffraction study confirmed its molecular structure and revealed that 3,4,5-trimethoxy-benzoyl salicylahydrazone was a tridentate and approximately planar ligand. The complex crystallizes in the triclinic space group P1BAR with a = 9.208(3), b = 12.536(2), c = 12.187(4) angstrom, alpha = 113.12(2), beta = 90.58(2), gamma = 81.42(2), V = 1277.5(6) angstrom, Z = 2. The structure was refined to R = 0.033 and R(w) = 0.041 for 3944 observed independent reflections. The tin atom has a distorted trigonal bipyramidal coordination. The Sn-C bond lengths are 2.129(5) and 2.113(5) angstrom (av. 2.121(5) angstrom), the C-Sn-C angle is 123.3(2); the bond length between the tin atom and the chelating nitrogen is 2.173(3) angstrom. Two chain carbon atoms and the chelating nitrogen atom occupy the basal plane. The skeleton of two erect oxygen atoms and the tin atom is bent (O-Sn-O angle = 153.5(1)). In the complex, the ligand exists in the enol-form.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

二苯乙炔和金属锂在乙醚中反应得到1,4-二锂四苯基丁二烯,再与无水氧化希土反应得到了两种系金属条-2,3,4,5-四苯基环戊二烯环状化合物。通过元素分析、红外光谱、核磁共振谱、热失重及电子能谱的分析,对所合成的化合物进行了表征;并对化合物的水解产物作了红外光谱、质谱和核磁共振谱分析,确认下列两种化合物的存在:

Relevância:

100.00% 100.00%

Publicador:

Resumo:

本工作合成了磺化的3,4-聚异戊二烯及其离子聚合体,IR和NMR谱图证明对3,4-聚异戊二烯的磺化反应是成功的,并且磺酸基团主要与3,4-链节的侧基双键发生反应。WAXD对磺化3,4-聚异戊二烯及其离聚体的研究表明,磺化度的增加使离聚体的结晶能力降低,SAXS结果表明,在离子含量为3.29mol%的离聚体中,未观察到离子簇聚集,只观察到多重离子对的散射。

Relevância:

100.00% 100.00%

Publicador:

Resumo:

本文首次合成了铕(Ⅲ)和铽(Ⅲ)与3,4-呋喃二甲酸配合物,研究了它们的IR、DTA、TG、DTG和荧光光谱等性质,并完成了单晶的晶体分析。结果表明,配合物为〔Ln·HL_2(H_2O)_2〕_2·2H_2O(Ln=Eu(Ⅲ),Tb(Ⅲ);H_2L=3,4-呋喃二甲酸),属单斜晶系,P2/c空间群,Z=2,晶胞参数对铕和铽配合物分别为α=10.842(1),10.801(4);b=8.725(2),8.664(2);c=16.366(4),16.308(6)A;β=93.50(1),93.67(3)°;V=1545.3(5),1523.0(8)A~3。

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A new lead(II) phosphonate, Pb[(PO3)(2)C(OH)CH3]center dot H2O (1) was hydrothermally synthesized and characterized by IR, elemental analysis, UV, TGA, SEM, and single crystal X-ray diffraction analysis. X-ray crystallographic study showed that complex 1 has a two-dimensional double layered hybrid structure containing interconnected 4- and 12-membered rings and shows an unusual (5,5)-connected (4(7) . 6(3)) (4(8) .6(2)) topology. (C) 2008 Elsevier B.V. All rights reserved.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This paper describes the simultaneous determination of allantoin, quercetin, and 1-methyl-1,2,3,4-tetrahydro-beta-carboline-3-carboxylic acid (MTCCA) in Nitraria tangutorum Bobr seed by HPLC-APCI-MS and CE (capillary electrophoresis) methods. The final optimized chromatographic conditions were investigated in a reversed-phase Eclipse XDB-C8 column (150 x 4.6 mm, 5 mu m). A seventeen-minute gradient elution, (A: aqueous acetonitrile 20% (v/v); B: aqueous acetonitrile 60% (v/v); C: pure acetonitrile 100%) at a flow rate of 1.0 mL/min was selected for the separation of three natural products with diode array detection (DAD) at 220 nm. A CE experiment was carried out in a fused silica capillary with 32 mmol/L boric acid (pH 10), 32 mmol/L SDS and acetonitrile (10.0%, v/v). The applied potential and temperature was, respectively, set at 19 kV and 25 degrees C. After development, the validation was performed in parallel for HPLC and CE, with the same standards and sample to avoid differences due to the manipulation. The validation parameters of both techniques were adequate for the intended purpose.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A pre-column derivatization method for the sensitive determination of amines using the labeling reagent 1,2-benzo-3,4-dihydrocarbazole-9-isopropyl chloroformate (BCIC-Cl) followed by high-performance liquid chromatography with fluorescence detection has been developed. Identification of derivatives is carried out by high performance liquid chromatography/atmospheric pressure chemical ionization (LC-APCl-MS-MS). The chromophore of 2-(9-carbazole)-ethyl chloroformate (CEOC) reagent is replaced by 1,2-benzo-3,4-dihydrocarbazole-9-isopropyl functional group, which results in a sensitive fluorescence derivatizing reagent BCIC-Cl. BCIC-Cl can easily and quickly label amines. Derivatives are stable enough to be efficiently analyzed by high-performance liquid chromatography and show an intense protonated molecular ion corresponding m/z [MH](+) under APCl in positive-ion mode. The collision-induced dissociation of protonated molecular ion formed a product at m/z 260 corresponding to the cleavage of CH2-OCO bond. Studies on derivatization demonstrate excellent derivative yields over the pH 9.0-10.0. Maximal yields close to 100% are observed with a 3 to 4-fold molar reagent excess. In addition, the detection responses for BCIC derivatives are compared with those obtained using CEOC and FMOC as derivatization reagents. The ratios of l(BCIC)/l(CEOC) and l(BCIC)/l(FMOC) are, respectively, 1.23-3.14 and 1.25-3.08 for fluorescent (FL) responses (here, l is relative fluorescence intensity). Separation of the derivatized amines had been optimized on reversed-phase Eclipse XDB-C-8 column. Detection limits are calculated from 1.0 pmol injection, at a signal-to-noise ratio of 3, are 10.6-37.8 fmol. The mean interday accuracy ranges from 94 to 105% for fluorescence detection with the largest mean %CV < 7.5. The mean interday precision for all standards is < 6.0% of the expected concentration. Excellent linear responses are observed with coefficients of > 0.9997.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A pre-column derivatization method for the sensitive determination of amino acids and peptides using the tagging reagent 1,2-benzo-3,4dihydrocarbazole-9-ethyl chloroformate (BCEOC) followed by high-performance liquid chromatography with fluorescence detection has been developed. Identification of derivatives was carried out by liquid chromatography/electrospray ionization mass spectrometry (LC/ESI-MS/MS). The chromophore of 2-(9-carbazole)-ethyl chloroformate (CEOC) reagent was replaced by 1,2-benzo-3,4-dihydrocarbazole functional group, which resulted in a sensitive fluorescence derivatizing reagent BCEOC. BCEOC can easily and quickly label peptides and amino acids. Derivatives are stable enough to be efficiently analyzed by high-performance liquid chromatography. The derivatives showed an intense protonated molecular ion corresponding m/z (M + H)(+) under electrospray ionization (ESI) positive-ion mode with an exception being Tyr detected at negative mode. The collision-induced dissociation of protonated molecular ion formed a product at m/z 246.2 corresponding to the cleavage of C-O bond of BCEOC molecule. Studies on derivatization demonstrate excellent derivative yields over the pH 9.0-10.0. Maximal yields close to 100% are observed with a 3-4-fold molar reagent excess. Derivatives exhibit strong fluorescence and extracted detzvatization solution with n-hexane/ethyl acetate (10:1, v/v) allows for the direct injection with no significant interference from the major fluorescent reagent degradation by-products, such as 1,2-benzo-3,4-dihydrocarbazole-9-ethanol (BDC-OH) (a major by-product), mono- 1,2-benzo-3,4-dihydrocarbazole-9-ethyl carbonate (BCEOC-OH) and bis-(1,2-benzo-3,4-dihydrocarbazole-9-ethyl) carbonate (BCEOC)(2). In addition, the detection responses for BCEOC derivatives are compared to those obtained with previously synthesized 2-(9-carbazole)-ethyl chloroformate (CEOC) in our laboratory. The ratios AC(BCEOC)/AC(CEOC) = 2.05-6.51 for fluorescence responses are observed (here, AC is relative fluorescence response). Separation of the derivatized peptides and amino acids had been optimized on Hypersil BDS C-18 column. Detection limits were calculated from 1.0 pmol injection at a signal-to-noise ratio of 3, and were 6.3 (Lys)-177.6 (His) fmol. The mean interday accuracy ranged from 92 to 106% for fluorescence detection with mean %CV < 7.5. The mean interday precision for all standards was < 10% of the expected concentration. Excellent linear responses were observed with coefficients of > 0.9999. Good compositional data could be obtained from the analysis of derivatized protein hydrolysates containing as little as 50.5 ng of sample. Therefore, the facile BCEOC derivatization coupled with mass spectrometry allowed the development of a highly sensitive and specific method for the quantitative analysis of trace levels of amino acids and peptides from biological and natural environmental samples. (c) 2005 Elsevier B.V. All rights reserved.