920 resultados para 1 kyr running mean


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Objectives: The aim of this study was to evaluate the intrapulpal temperature variation after bleaching treatment with 35% hydrogen peroxide using different sources of activation. Material and Methods: Twenty-four human teeth were sectioned in the mesiodistal direction providing 48 specimens, and were divided into 4 groups (n=12): (G1) Control - Bleaching gel without light activation, (G2) Bleaching gel + halogen light, (G3) Bleaching gel + LED, (G4) Bleaching gel + Nd: YAG Laser. The temperatures were recorded using a digital thermometer at 4 time points: before bleaching gel application, 1 min after bleaching gel application, during activation of the bleaching gel, and after the bleaching agent turned from a dark-red into a clear gel. Data were analyzed statistically by the Dunnet's test, ANOVA and Tukey's test (alpha=0.05). Results: The mean intrapulpal temperature values (degrees C) in the groups were: G1: 0.617 +/- 0.41; G2: 1.800 +/- 0.68; G3: 0.975 +/- 0.51; and G4: 4.325 +/- 1.09. The mean maximum temperature variation (MTV) values were: 1.5 degrees C (G1), 2.9 degrees C (G2), 1.7 degrees C (G3) and 6.9 degrees C (G4). When comparing the experimental groups to the control group, G3 was not statistically different from G1 (p>0.05), but G2 and G4 presented significantly higher (p<0.05) intrapulpal temperatures and MTV. The three experimental groups differed significantly (p<0.05) from each other. Conclusions: The Nd: YAG laser was the activation method that presented the highest values of intrapulpal temperature variation when compared with LED and halogen light. The group activated by LED light presented the lowest values of temperature variation, which were similar to that of the control group.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

O objetivo deste estudo foi analisar a validade do consumo máximo de oxigênio (VO2max), velocidade associada ao VO2max (vVO2max), tempo de exaustão na vVO2max (Tlim), limiar anaeróbio (LAn), economia de corrida (EC) e força explosiva (FE) para predizer a performance aeróbia de corredores de endurance nas distâncias de 1.500m, 5.000m e 10.000m. Participaram deste estudo 11 corredores de endurance moderadamente treinados (28,36 ± 6,47 anos) que realizaram os seguintes testes: provas simuladas em uma pista de 400m em diferentes dias, nas distâncias de 10.000m, 5.000m e 1.500m; teste incremental máximo para determinar os índices VO2max, vVO2max, e LAn; um teste submáximo de carga constante para determinar a EC, seguido por um teste máximo também de carga constante a 100% da vVO2max para determinar o Tlim; e um teste de salto vertical para determinar a FE. de acordo com a análise de regressão múltipla, a vVO2max utilizada de forma isolada explicou 57% da variação de performance na prova de 1.500m. No entanto, quando o Tlim, a FE e a vVO2max foram analisados em conjunto, a explicação para a performance nessa prova foi de 88%. Nos 5.000m, o Tlim, a vVO2max e o LAn responderam por 88% da variação de performance (p < 0,05). Diferentemente, na prova de 10.000m, o LAn foi a única variável que apresentou capacidade de predição de performance. em conclusão, a predição da performance aeróbia de corredores moderadamente treinados por meio de variáveis fisiológicas e neuromusculares é dependente da distância da prova (1.500m, 5.000m e 10.000m)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The use of internal standardization for simultaneous atomic absorption spectrometry (SIMAAS) was investigated for Cd and Pb determination in whole blood. The comparison of thermochemical and physicochemical parameters allowed the selection of Ag, Bi, and Tl as internal standard candidates. Correlation graphs, plotted from the normalized absorbance signals (n = 20) of internal standard (axis y) versus analyte ( axis x), precision and accuracy were used to select Ag as the most appropriate internal standard. Blood samples were diluted (1 + 9) with 0.11% (m/v) Triton X-100 + 1.1% (v/v) HNO3 + 0.28% (m/v) NH4H2PO4 + 10 mug L-1 Ag+. Pyrolysis and atomization temperatures for the optimized heating program were 550 and 1700 degreesC, respectively. Characteristic masses based on integrated absorbance were 1.68 +/- 0.01 pg for Cd and 30.3 +/- 0.1 pg for Pb. The detection limits (DL) were 0.095 +/- 0.001 mug L-1 and 0.86 +/- 0.01 mug L-1 for Cd and Pb, respectively. The mean RSD for all determinations was the same for Cd (13 +/- 9%) with or without Ag as internal standard ( IS). on the other hand, the use of Ag as IS improved the RSD for Pb from 3.6 +/- 4.0% to 2.2 +/- 2.0%. An effective contribution of the internal standard Ag was verified in the recoveries of spiked samples (0.5 mug L-1 Cd2+ and 5.0 mug L-1 Pb2+). The mean recoveries were 81 +/- 8% and 91 +/- 4% for Cd, and 80 +/- 11% and 93 +/- 6% for Pb without and with IS correction, respectively. This is the first application of IS for a simultaneous determination by SIMAAS.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The study of the influence of motion and initial intra-articular pressure (IAP) on intra-articular pressure profiles in equine cadaver metatarsophalangeal (MTP) joints was undertaken as a prelude to in vivo studies, Eleven equine cadaver MTP joints were submitted to 2 motion frequencies of 5 and 10 cycles/min of flexion and extension, simulating the condition of lower and higher (double) rates of passive motion. These frequencies were applied and pressure profiles generated with initial normal intra-articular pressure (-5 mmHg) and subsequently 30 mmHg intra-articular pressure obtained by injection of previously harvested synovial fluid.The 4 trials performed were 1) normal IAP; 5 cyles/min; 2) normal IAP; 10 cycles/min; 3) IAP at 30 mmHg; 5 cycles/min and 4) IAP at 30 mmHg; 10 cycles/min. The range of joint motion applied (mean +/- s.e.) was 67.6 +/- 1.61 degrees with an excursion from 12.2 +/- 1.2 degrees in extension to 56.2 +/- 2.6 degrees in flexion, Mean pressure recorded in mmHg for the first and last min of each trial, respectively, were 1) -5.7 +/- 0.9 and -6.3 +/- 1.1; 2) -5.3 +/- 1.1 and -6.2 +/- 1.1; 3) 58.8 +/- 8.0 and 42.3 +/- 7.2; 4) 56.6 +/- 3.7 and 40.3 +/- 4.6. Statistical analyses showed a trend for difference between the values for the first and last minute in trial 3 (0.05>P<0.1) with P = 0.1 and significant difference (P = 0.02) between the mean IAP of the first and last min in trial 4. The loss of intra-articular pressure associated with time and motion was 10.5, 16.9, 28.1 and 28.9% for trials 1-4, respectively. As initial intraarticular pressure and motion increased, the percent loss of intra-articular pressure increased.The angle of lowest pressure was 12.2 +/- 1.2 (mean +/- s.e.) in extension in trials 1 and 2, In trials 3 and 4, the lowest pressures were obtained in flexion with the joints at 18.5 +/- 2.0 degrees (mean +/- s.e.). This demonstrated that the joint angle of least pressure changed as the initial intra-articular pressure changed and there would not be a single angle of least pressure for a given joint.The volume of synovial fluid recovered from the MTP joints in trial 3 compared to 4 (trials in which fluid was injected to attain IAP of 30 mmHg) was not significantly different, supporting a soft tissue compliance change as a cause for the significant loss of intra-articular pressure during the 15 min of trial 4.The pressure profiles generated correlate well with in vivo values and demonstrated consistent pressure profiles. Our conclusions are summarised as follows:1. Clinically normal equine MTP joints which were frozen and then later thawed were found to have mostly negative baseline intra-articular pressures, as would be expected in living subjects,2. Alternate pressure profiles of the dorsal and plantar pouch at baseline intra-articular pressure document the presence of pressure forces that would support 'back and forth' fluid movement between joint compartments. This should result in movement of joint fluid during motion, assisting in lubrication and nutrition of articular cartilage,3. If joint pressure was initially greater than normal (30 mmHg), as occurs in diseased equine MTP joints, joint motion further increased joint capsule relaxation (compliance) and, therefore, reduced intra-articular pressure.4. Peak intra-articular pressures reached extremely high values (often >100 mmHg) in flexion when initial pressure was 30 mmHg. Joint effusion pressures recorded for clinical MCP joints are frequently 30 mmHg. These IAP values are expected to produce intermittent synovial ischaemia in clinical cases during joint flexion.5, Additional in vivo studies are necessary to confirm our conclusions from this study and to identify the contributions of fluid absorption and the presence of ischaemia in a vascularised joint.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A coal deposit was studied at Sapopema (PR) in the upper part of the Tubarao Group. The eliptical deposit is made up by a single layer of 1.2 m mean thickness and lies at a depth of 380 to 700 m. The semi-variogram, using the spherical model, revealed a range of 1.5 km and no nugget effect. Area kriging estimation for a grid of 0.5 × 0.5 km showed a value of 50.121.750 ton, very close to the real reserve one. -from English summary

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The purpose of this study was to identify and quantify the magnitude of the slow component of VO2 (SC) in children during running exercise, performed at heavy intensity domain (75%Δ), using two different mathematical models: a) three-exponential model and; b) ΔVO2 6-3 min. Eight healthy male children (11.92 ± 0.63 years; 44.06 ± 13.01 kg; 146.63 ± 7.25 cm; and sexual maturity levels 1 and 2), not trained, performed in different days the following tests: 1) incremental running treadmill test to determine the peak oxygen uptake (VO2peak) and the lactate threshold (LT); and 2) two transitions from baseline to 75%Δ [75%Δ = LT + 0.75 x (VO2 peak - LT)] for six minutes on treadmill. The SC was determined by two models: a) three-exponential model (Exp3); and b) the VO2 difference between the sixth and the third exercise minute (ΔVO2 6-3min). The SC was expressed as the absolute (ml/min) and percent contribution (%) to the total change in VO 2. The SC values determined by model Exp3 (129.69 ± 75.71 ml/min and 8.4 ± 2.92%) and ΔVO2 6-3 min (68.69 ± 102.54 ml/min and 3.6 ± 7.34%) were significantly different. So, the SC values in children during running exercise performed at heavy intensity domain (75%Δ) are dependent of the analysis model (Exp3 x ΔVO2 6-3 min).

Relevância:

100.00% 100.00%

Publicador:

Resumo:

An experiment with an Elisa hybrid sweet pepper (Capsicum annuum L) crop using fertirrigation system was carried out in greenhouse. The aim of this study was to evaluate the quantitative effects of an increasing soil saline concentration on the production. The saline concentration was changed by the variation of the KC1 and Ca 2NO 3 concentration in order to obtain high soil electrical conductivity (EC) values. Standard fertigation system (1.5 dS m -1) values were used as control parameters. Besides that, the possibility of saline stress attenuation by applying organic material into the soil was studied. It was observed that the EC levels used in the crop were inversely correlated to the fructification index and the fruit mean weight. Under the most severe treatment (6.0 dS m -1) the fruit mean weight was reduced up to 58% and the mean produced fiuit number per plant was also reduced up to 55%, when compared to the obtained results under controlled conditions. These results demonstrated that the EC variation in the soil solution had strong interference on th production parameters selected for the studies.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The aim of this study was to determine alkaline phosphatase (ALP; E.C. 3.1.3.1) activity and major expression in homogenates obtained from different regions of Golden hamster epididymis, comprising the initial segment, head, body and tail, with concomitant research of this enzyme localization and activity in samples of tissues. These were collected from the same regions and investigated by histochemical conventional study performed on frozen histological sections. No significant differences in mean ALP activity, reported as U.100 mg-1 of tissue, were observed among the biological specimens collected from the epididymidis initial segment (0.92 ± 0.28 U.100 mg-1 tissue), head (1.07 ± 0.67 U.100 mg-1 tissue) and body (0.77 ± 0.23 U.100 mg-1 tissue). However, mean ALP activity was significantly higher in the epididymal tail (8.94 ± 0.40 U.100 mg-1 tissue) compared with the precedent segments. The findings suggested that ALP plays a significant role in the tail of the Golden hamster epididymidis, mediating androgenic segregation necessary to maintain the epithelial integrity. Furthermore, ALP acts on active transport of substances between the luminal fluid and spermatozoon membrane, and contrariwise. Thus, the high concentration of ALP in the epididymal tail helps to indicate the importance of this enzyme in the metabolism and maintenance of spermatozoa maturation and storage into the epididymidis luminal compartment, perhaps directly influencing the normal reproductive morphophysiology.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Objective: the purpose of this prospective study was to cephalometrically analyze the dentoalveolar and soft tissue changes after the orthodontic treatment followed by the extraction of four premolars. Material and methods: the sample was comprised by 30 Class II division 1 patients with mean initial age of 12 years and 4 months. Two lateral cephalograms were obtained from each patient at the beginning and at the end of the treatment. The variables analyzed were the nasalabial changes and upper and lower incisors changes in relation to a vertical and horizontal x and y reference lines. Results: upper and lower incisors retraction was 3.4 and 1.8mm, respectively. The SNA angle was decresead by 1.7 degrees followed by a retraction of point A mainly due to the upper incisor retraction. There was a significant decrease of the Wits and ANB variables. There was an increase in the lower anterior facial height. Upper incisor retraction was followed by an increase in the nasolabial angle (ratio 1:2.8 degrees). However, a wide range of individual variability was found. Conclusions: the present study did not support the simple expectation that treatment with extractions of four premolars will result in a dished in face. It appeared that facial changes were more related to a normal facial growth, the amount of incisor retraction and the anchorage control during the upper and lower incisor.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The ovarian activity was accessed by ultrasound throughout 10 estrous cycles from Jennies (Marchador Brasileira). Daily ultrasound examinations were performed and the dada was retrospectively studied based on daily identification of each follicle detected. Blood samples were collected every 24 hours from ovulation (D0) until the next identified ovulation. The follicles measuring 11mm were detected and their mean diameter was registered daily using an ovarian map and permitting a retrospective evaluation of the dada, which represented the follicular growth dynamics. One and two major follicular waves were detected in six (60%) and four (40%) cycles respectively from ten estrous cycles in the present study. The primary wave emergency and follicle deviation from the cycles observed during the present study with one major follicular wave occurred at day 10.2 ± 0.75 and at day14.1 ± 0.81 and for cycles with two major waves, those events occurred at 9.0 ± 2.0 and 14.0 ± 1.15 days after ovulation. The maximum diameter of the dominant follicle at the cycles with one and two follicular waves were 37.2 ± 3.35 mm and 37.3 ± 1.1, respectively. The mean intervals from two ovulations were 23.0 ± 1.79 and 22.3 ± 1.26 days when observed in cycles with one and two major follicular waves. The maximum diameter of the dominant follicle was slightly smaller when double ovulations were observed if compared with the single ovulations (P > 0.05). It can be concluded that wave emergency period is observed around 9.6 days of the estrous cycle and the occurrence of deviation can be observed on day 14 of the estrous cycle.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This study measured the critical temperature reaching time and also the variation of temperature in the surface of the cervical region and within the pulp chamber of human teeth submitted to dental bleaching using 35% hydrogen peroxide gel activated by three different light sources. The samples were randomly divided into 3 groups (n = 15), according to the catalyst light source: Halogen Light (HL), High Intensity Diode Laser (DL), and Light Emmited Diode (LED). The results of temperature variation were submitted to the analysis of variance and Tukey test with p < 0.05. The temperature increase (mean value and standard deviation) inside the pulp chamber for the HL group was 6.8 ± 2.8°C; for the DL group was 15.3 ± 8.8°C; and for the LED group was 1.9 ± 1.0°C for. The temperature variation (mean value and standard deviation) on the tooth surface, for the group irradiated with HL was 9.1 ± 2.2°C; for the group irradiated with DL were 25.7 ± 18.9°C; and for the group irradiated with LED were 2.6 ± 1.4°C. The mean temperature increase values were significantly higher for the group irradiated with DL when compared with groups irradiated with HL and LED (p < 0.05). When applying the inferior limits of the interval of confidence of 95%, an application time of 38.7 s was found for HL group, and 4.4 s for DL group. The LED group did not achieve the critical temperatures for pulp or the periodontal, even when irradiated for 360 s. The HL and DL light sources may be used for dental bleaching for a short period of time. The LED source did not heat the target tissues significantly within the parameters used in this study. © 2010 Pleiades Publishing, Ltd.