994 resultados para Úlceras de pressão


Relevância:

20.00% 20.00%

Publicador:

Resumo:

The sanitation companies from Brazil has a great challenge for the XXI century: seek to mitigate the rate of physical waste (water, chemicals and electricity) and financial waste caused by inefficient operating systems drinking water supply, considering that currently we already face, in some cases, the scarcity of water resources. The supply systems are increasingly complex as they seek to minimize waste and at the same time better serve the growing number of users. However, this technological change is to reduce the complexity of the challenges posed by the need to include users with higher quality and efficiency in services. A major challenge for companies of water supplies is to provide a good quality service contemplating reducing expenditure on electricity. In this situation we developed a research by a method that seeks to control the pressure of the distribution systems that do not have the tank in your setup and the water comes out of the well directly to the distribution system. The method of pressure control (intelligent control) uses fuzzy logic to eliminate the waste of electricity and the leaks from the production of pumps that inject directly into the distribution system, which causes waste of energy when the consumption of households is reduced causing the saturation of the distribution system. This study was conducted at Green Club II condominium, located in the city of Parnamirim, state of Rio Grande do Norte, in order to study the pressure behavior of the output of the pump that injects water directly into the distribution system. The study was only possible because of the need we had to find a solution to some leaks in the existing distribution system and the extensions of the respective condominium residences, which sparked interest in developing a job in order to carry out the experiments contained in this research

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Research for better performance materials in biomedical applications are constants. Thus recent studies aimed at the development of new techniques for modification of surfaces. The low pressure plasma has been highlighted for its versatility and for being environmentally friendly, achieving good results in the modification of physic chemical properties of materials. However, it is requires an expensive vacuum system and cannot able to generate superficial changes in specific regions. Furthermore, it is limits their use in polymeric materials and sensitive terms due to high process temperatures. Therefore, new techniques capable of generating cold plasma at atmospheric pressure (APPJ) were created. In order to perform surface treatments on biomaterials in specific regions was built a prototype capable of generating a cold plasma jet. The prototype plasma generator consists of a high voltage source, a support arm, sample port and a nozzle through which the ionized argon. The device was formed to a dielectric tube and two electrodes. This work was varied some parameters such as position between electrodes, voltage and electrical frequency to verify the behavior of glow discharges. The disc of titanium was polished and there was a surface modification. The power consumed, length, intensity and surface modifications of titanium were analyzed. The energy consumed during the discharges was observed by the Lissajous figure method. To check the length of the jets was realized with Image Pro Plus software. The modifications of the titanium surfaces were observed by optical microscopy (OM ) and atomic force microscopy (AFM ). The study showed that variations of the parameters such as voltage, frequency and geometric position between the electrodes influence the formation of the plasma jet. It was concluded that the plasma jet near room temperature and atmospheric pressure was able to cause modifications in titanium surface

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objetivou-se com este trabalho avaliar o efeito de pontas de pulverização, pressão e intensidade do vento na deriva gerada em aplicações simuladas de herbicidas aplicados em pré-emergência. Os modelos de pontas de pulverização e as respectivas pressões testadas foram: SF 11002 (207 e 310 kPa), JA-2 (345 e 655 kPa) e AVI 11002 (207 e 414 kPa). As aplicações foram realizadas em dois períodos, em dias com condições de velocidade de vento distintas, em uma área de 1.200 m², localizada na Fazenda Experimental da FCA/UNESP. Um pulverizador com barra de 12 m, 24 bicos e tanque de 600 L foi utilizado nas aplicações. A calda de aplicação foi composta por água e o corante alimentício FDC-1 foi usado como traçador. A deriva foi amostrada por coletores ativos fixados sobre a barra de pulverização. As velocidades mínimas, médias e máximas de vento registradas no primeiro e segundo períodos das aplicações foram de 7, 14 e 23 km h-1 e 1, 5 e 18 km h-1, respectivamente. Nas duas ocasiões de aplicação, as pontas de pulverização com indução de ar AVI 11002 e de jato cônico vazio JA-2 a 655 kPa resultaram nas menores e maiores quantidades de depósito de líquido detectadas, respectivamente. A maior intensidade do vento incrementou a deriva. A redução na pressão pode ser utilizada para controle de deriva, mas a seleção adequada de uma ponta mostrou ser mais eficiente para esse propósito.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The composition of petroleum may change from well to well and its resulting characteristics influence significantly the refine products. Therefore, it is important to characterize the oil in order to know its properties and send it adequately for processing. Since petroleum is a multicomponent mixture, the use of synthetic mixtures that are representative of oil fractions provides a better understand of the real mixture behavior. One way for characterization is usually obtained through correlation of physico-chemical properties of easy measurement, such as density, specific gravity, viscosity, and refractive index. In this work new measurements were obtained for density, specific gravity, viscosity, and refractive index of the following binary mixtures: n-heptane + hexadecane, cyclohexane + hexadecane, and benzene + hexadecane. These measurements were accomplished at low pressure and temperatures in the range 288.15 K to 310.95 K. These data were applied in the development of a new method of oil characterization. Furthermore, a series of measurements of density at high pressure and temperature of the binary mixture cyclohexane + n-hexadecane were performed. The ranges of pressure and temperature were 6.895 to 62.053 MPa and 318.15 to 413.15 K, respectively. Based on these experimental data of compressed liquid mixtures, a thermodynamic modeling was proposed using the Peng-Robinson equation of state (EOS). The EOS was modified with scaling of volume and a relatively reduced number of parameters were employed. The results were satisfactory demonstrating accuracy not only for density data, but also for isobaric thermal expansion and isothermal compressibility coefficients. This thesis aims to contribute in a scientific manner to the technological problem of refining heavy fractions of oil. This problem was treated in two steps, i.e., characterization and search of the processes that can produce streams with economical interest, such as solvent extraction at high pressure and temperature. In order to determine phase equilibrium data in these conditions, conceptual projects of two new experimental apparatus were developed. These devices consist of cells of variable volume together with a analytical static device. Therefore, this thesis contributed with the subject of characterization of hydrocarbons mixtures and with development of equilibrium cells operating at high pressure and temperature. These contributions are focused on the technological problem of refining heavy oil fractions

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The use of the History and the Philosophy of Science (HPS) for the teaching of science and scientific subjects has been advocated in recent decades. It has been pointed out that the History of Science could make for a deeper learning of scientific concepts, since it would promote a contact with the problems which that knowledge has set out to solve. Furthermore, historical episodes would serve to put the discussions about the nature of scientific knowledge into context. With a view to explore those potentialities, the literature in the field has sought to identify the challenges and obstacles for the didactic transposition of subjects from the History of Science. Amongst many aspects, the deficiencies in the training of teachers, so that they can work with the insertion of HPS in the classroom have been highlighted. Another aspect that has been mentioned to be a challenge has to do with the didactic transposition of the Primary Sources, that is, of the original texts on the History of Science. The Primary Sources have significant potentialities: making a connection possible between scientists and concepts, showing the difficulties faced during scientific endeavors, perceiving the role of mistakes as obstacles to be surpassed, not as defeat, etc. On the other hand, there has been little exploration of these concepts in an educational context, due to their own peculiarities. The original texts are often hard to understand and their interpretation demands knowledge of the historical and scientific context in which they were written, as well as skills pertaining to the conduction of research in the field of the History of Science. With this scenario in mind, the research towards this Professional MSc degree starts from the challenge of elaborating and discussing proposals which could enable the didactical transposition of the Primary Sources. We have worked specifically with Primary Sources on the History of the Vacuum and of the Atmospheric Pressure, because of the insertion of these subjects in the Brazilian High School curriculum, in connection with the didactical textbooks. "Historic Journals" were made up from clippings of the original historical texts, as was a Didactical Unit, which takes the usual textbooks as a basis and contemplates using the Journals and the entire Primary Sources in High School. At last, we have elaborated and implemented a course designed for the preparation of teachers and for being an opportunity for the discussion of the feasibility of putting these kinds of proposal into practice

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The aim of this study was to analyze the association between nutritional status and blood pressure in adolescents from a private school. Were recruited 316 young of both gender with age raging from 11 to 15 years old. Were measured body mass, stature, systolic blood pressure and diastolic blood pressure. The statistic procedures were composed by median, interquartile range, chi-square test and Poisson regression. The prevalence of overweight and high blood pressure was significantly higher in boys (38% and 24%, respectively) when compared to girls (19.3% and 14.4%, respectively). Overweight adolescents presented a higher risk (about 2-fold) to develop high blood pressure. In conclusion, overweight seems to be associate with high blood pressure in adolescents.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJETIVO: Verificar a efetividade da técnica de pressão expiratória positiva oscilante (PEPO) utilizando pressões expiratórias pré-determinadas sobre a viscosidade e a transportabilidade do escarro em pacientes com bronquiectasia. MÉTODOS: Foram incluídos no estudo 15 pacientes estáveis com bronquiectasia (7 homens; média de idade = 53 ± 16 anos), submetidos a duas intervenções PEPO consecutivas, com 24 h de intervalo entre si, utilizando pressões expiratórias de 15 cmH2O (P15) e 25 cmH2O (P25). O protocolo consistiu de tosse voluntária; nova expectoração voluntária após 20 min, denominado tempo zero (T0); repouso de 10 min; e utilização da técnica em duas séries de 10 min (S1 e S2) de PEPO em P15 e P25, com intervalo de 10 min entre si. A viscosidade e transportabilidade do escarro foram avaliadas pela viscosimetria, velocidade relativa de transporte no palato de rã, deslocamento em máquina simuladora de tosse e ângulo de adesão. As amostras de escarro foram coletadas em T0, após S1 e após S2. Testes estatísticos específicos foram aplicados de acordo com a distribuição dos dados. RESULTADOS: Houve diminuição significante da viscosidade do escarro após S1 em P15 e após S2 em P25. Não houve diferenças significantes entre todas as amostras para a transportabilidade. CONCLUSÕES: Houve diminuição da viscosidade do escarro quando a PEPO foi realizada em P15 e P25, o que sugere que não seja necessário gerar alta pressão expiratória para obter o resultado desejado.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The results of studies about the ideal resistance training intensity for reduction of resting blood pressure levels, as well as this type of training to increase the functional capacity of hypertensive older women are still unclear, since the few investigations usually analyze young individuals normotensive, and the literature lacks precise information in elderly hypertensive subjects. Objectives: To determine the effect of two resistance training intensities on resting blood pressure and the effect of resistance training on functional capacity in elderly women with systemic arterial hypertension, analyzing these variables before and after eight weeks of intervention. Methods: Patients underwent eight weeks of resistance training, with a frequency of three times per week on alternate days, in the afternoon. The exercises performed were: leg press, bench press, knee extension, lat pull-down, knee flexion, shoulder abduction, standing cable hip abduction and biceps curl. Results: It was found that patients who underwent training with moderate resistance, showed a reduction on resting values of diastolic blood pressure (DBP) p<0.03 and of mean arterial pressure (MAP) p<0.03. Patients who underwent mild resistance training showed reduction in resting values of MAP (p<0.03) and a tendency to decrease in DBP (p<0.06). With regard to functional capacity, the results showed significant increase in the strength of arms and legs, agility and aerobic endurance (p<0.001) and maintaining flexibility (p>0.05). Conclusion: The data indicated that both mild and moderate resistance training, even when started in old age, promoted cardiovascular benefits and also improve the functional capacity of hypertensive older women.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The strength of respiratory muscle are frequently assessed by maximal inspiratory and expiratory pressure, however, the maneuvers to assess PImax and PEmax are difficult for many patients. The sniff nasal inspiratory pressure (SNIP) is a simple and noninvasive technique use to assess inspiratory muscles strength. Reference values have been previous established for SNIP in adults but no previous studies have provided reference values for SNIP in adult Brazilian population. The main objective of this study were propose reference values of SNIP for Brazilian population through establishment of relationship between anthropometric measurements, physical activity profile and SNIP and at the same time compare the values obtained with reference values previously published. We studied 117 subjects (59 male and 58 female) distributed in different age grouped 20-80 years old. The results showed on significant positive relationship between SNIP and height and negative correlation with age (p<0.05). In the multiple linear regression analysis only age continued to have an independent predictive role for the two dependent variables that correlated with SNIP. The values of SNIP found in Brazilian population were higher when compared with predict values of previous studies. The results of this study provide reference equations of SNIP for health Brazilian population from 20 to 80 years old

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The clinical importance of evaluating the respiratory muscles with a variety of tests has been proposed by several studies, once that the combination of several tests would allow a better diagnosis and therefore, a better clinical follow of disorders of the respiratory muscles. This study aimed to evaluate the feasibility of adapting a national electronic manovacuometer to measure the nasal inspiratory pressure (study 1) and analyze the level of load intensity of maximum voluntary ventilation, as well as the variables that may influence this maneuver in healthy subjects (study 2). We studied 20 healthy subjects by a random evaluation of two measures of SNIP in different equipments: a national and an imported. In study 2 it was analyzed the intensity of the load of MVV test, change in pressure developed during the maneuver, the possible differences between genders, and the correlations between the flow developed in the test and the result of MVV. In study 1 it was found the average for both measures of nasal inspiratory pressures: 125 ± 42.4 cmH2O for the imported equipment and 131.7 ± 28.7 cmH2O for the national one. Pearson analysis showed a significant correlation between the average, with a coefficient r = 0.63. The average values showed no significant differences evaluated by paired t test (p> 0.05). In the Bland-Altman analysis it was found a BIAS = 7 cmH2O, SD 32.9 and a confidence interval of - 57.5 cmH2O up to 71.5 cmH2O. In the second study it was found significant differences between the genders in the air volume moved, being higher in males 150.9 ± 13.1 l / min vs 118.5 ± 15.7 L / min for (p = 0.0002, 95% CI 44.85 to 20:05). Regarding the inspiratory and expiratory loading, they were significantly higher in men than in women, peak inspiratory pressure (34.7 ± 5.3 cmH2O vs 19.5 ± 4.2 cmH2O, 95% CI - 18.0 to -12.3, p <0.0001), peak expiratory (33.8 vs. 23.1 ± 5.9 cmH2O ± 5.4 cmH2O, 95% CI -17.1 to - 4.6, p <0.0001), and the delta pressure (59.7 ± 10 cmH2O vs 36.8 ± 8.3 cmH2O, 95% CI 14.5 to 31.2, p <0.0002). The Pearson correlation showed that the flow generated by the maneuver is strongly correlated with the delta-expiratory pressure / inspiratory (r2= 0.83,R = 0.91, 95%IC 0.72 a 0.97 e p< 0.0001).Through these results we suggest that the national electronic manovacuometer is feasible and safe to perform the sniff test in healthy subjects. For the MVV, there are differences between the genders in the intensity of pressure developed during the maneuver. We found a load intensity considered low during the MVV, and found a strong correlation between the flow generated in the test and the delta pressure expiratory / inspiratory

Relevância:

20.00% 20.00%

Publicador:

Resumo:

observar os efeitos agudos de diferentes intensidades de Pressão Expiratória Positiva (PEP) sobre a cinemática do complexo toracoabdominal de pacientes acometidos por Acidente Vascular Encefálico (AVE). Métodos: Foram selecionados 21 indivíduos com AVE e 16 indivíduos saudáveis pareados por idade sexo e IMC para grupo controle. Avaliamos função pulmonar, pressões dos músculos respiratórios e os volumes pulmonares por meio da Pletismografia Optoeletrônica durante três diferentes intensidades de PEP 10, 15 e 20 cmH2O. Resultados: o efeito da PEP no volume corrente (VC) do grupo AVE em relação ao grupo controle foi diferente. Enquanto o grupo controle aumentou o VC em relação a respiração tranquila em 343%, 395,2% e 431,8% nas PEP10, PEP15 e PEP20 cmH2O o grupo AVE aumento 186%, 218.8% e 209.5% (p < 0.0001). A PEP também influenciou de forma diferente em relação ao Tempo inspiratório com intensidades diferentes no grupo controle e AVE (p < 0.0001). No ciclo de trabalho foi observado um aumento no grupo controle nas PEP10 (p < 0.001) e PEP15 (p < 0.05) e no grupo AVE foi observada uma redução PEP20 (p < 0.01) quando comparada com a respiração tranquila. Os volumes operacionais do grupo AVE foi observado aumento do volume inspiratório final da parede torácica (Vifpt) e do Volume expiratório final da parede torácica (Vefpt) diferente do grupo controle que gerou aumento do Vifpt acompanhado de diminuição do Vefpt durante as três intensidades de PEP. Conclusão: A hiperinsuflação observada no grupo AVE demonstra que essa terapêutica deve ser utilizada com cautela especialmente nas intensidades maiores que 10 cmH2O para essa população

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Venous wounds cause physical, psychological and financial problems that impact the quality of life of patients. Treatment alternatives are investigated in order to reduce healthcare costs and improve quality of life of people affected by this problem. Physical resources, such as therapeutic ultrasound (US), are being considered in the treatment of ulcers as a potential healing agent. This study aimed to investigate the application of US as a treatment for venous ulcers. Subjects were divided into two groups: US group, where treatment consisted of 5 sessions of pulsed US (3 MHz, 1W/cm²) associated with compression and kinesiotherapy; and sham group, where individuals went through the same procedures, but with sham US therapy. Subjects were evaluated for wound size by planimetry and digital photography, visual analogue scale for pain, quality of life by the questionnaires SF- 36 and VEINES-QoL/Sym and enzymatic activity of metalloproteinases 2 and 9 by zymography. It was observed mean reduction in wound area of 41.58±53.8% for the US group and 63.47±37.2% for the placebo group, maintenance of quality of life scores in the US group and significant improvement (p<0.05) in the placebo group by VEINES questionnaire. It was observed decreased perception of pain in the placebo group. Sample feasibility for analysis of the protein activity of metalloproteinases 2 and 9 by zymography collected by swab method was also confirmed. Our data did not give us evidence to support the theory that the US accelerates healing of venous ulcers in a short-term analysis. However, we observed that standard care associated with compression therapy and kinesiotherapy were able to significantly shorten the progression of chronic venous ulcers

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Chronic venous disease (CVD) is evident among the chronic diseases and affects the elderly population and primarily is responsible for leg ulcers in this population. The use of dressings in the care of a venous ulcer is a fundamental part of the treatment for healing, however, evidence to assist in choosing the best dressing is scarce. The main objective of this study was to evaluate the effectiveness of treatment with hydrogel in the healing of venous ulcers using search methods, synthesis of information and statistical research through a systematic review and meta-analysis. Randomized controlled trials were selected in the following databases: CENTRAL; DARE; NHS EED; MEDLINE; EMBASE; CINAHL. Beyond these databases three websites were consulted to identify ongoing studies: ClinicalTrials.gov, OMS ICTRP e ISRCTN. The primary outcomes were analyzed: complete wound healing, incidence of wound infection and the secondary were: changes in ulcer size, time to ulcer healing, recurrence of ulcer, quality of life of participants, pain and costs of treatment. Four studies are currently included in the review with a total of 250 participants. The use of hydrogel appears to be superior to conventional dressing, gauze soaked in saline, for the healing of venous leg ulcers; 16/30 patients showed complete healing of ulcers (RR 5,33, 95%CI [1,73,16,42]). The alginate gel was shown to be more effective when compared to the hydrogel dressing in reduction of the wound area; 61,2% (± 26,2%) with alginate e 19,4% (± 24,3%) with hydrogel at the end of four weeks of treatment. Manuka honey has shown to be similar to the hydrogel dressings in percentage of area reduction. This review demonstrated that there is no evidence available about the effectiveness of the hydrogel compared to other types of dressings on the healing of venous leg ulcers of the lower limbs, thus demonstrating the need of future studies to assist health professionals in choosing the correct dressing.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

JUSTIFICATIVA E OBJETIVOS: Estudos introduziram novo método para avaliação da pré-carga, baseado na análise da variação da pressão sistólica (VPS) durante ventilação artificial. O objetivo desta pesquisa é avaliar se a VPS e sua derivada delta down (ddown) são indicadoras precoces de hipovolemia e guias de reposição volêmica com solução hiperosmótica e hiperoncótica. MÉTODO: Doze cães foram submetidos a sangramentos parciais de 5% da volemia até se atingir 20% da volemia (14 ml.kg-1). Antes (controle) e após cada sangramento foram realizadas análises hemodinâmicas, respiratórias e sangüíneas. Após, os cães foram submetidos à reposição com solução de NaCl a 7,5% em dextran 70 a 3,75% (SHD) (4 ml.kg-1) e novas análises dos atributos estudados foram realizadas aos 5 e 30 minutos após a reposição. RESULTADOS: A pressão arterial média diminuiu durante o sangramento e aumentou após a reposição, sem retornar aos valores do controle. As pressões da artéria pulmonar e do átrio direito (PAD) diminuíram antes e aumentaram após a reposição para valores semelhantes aos do controle. A pressão da artéria pulmonar ocluída (PAPO) diminuiu após o primeiro sangramento e manteve-se em valores abaixo aos do controle, mesmo após a reposição. O índice cardíaco não se alterou, mas aumentou após a reposição, para valores superiores aos do controle. O índice sistólico (IS) diminuiu antes e aumentou após a reposição, em níveis superiores aos do controle. Os índices de resistência vascular sistêmica (IRVS) e pulmonar (IRVP) não se alteraram antes, mas diminuíram após a reposição, com o IRVS em níveis inferiores aos do controle, e o IRVP em níveis semelhantes aos do controle. Os índices de trabalho sistólico dos ventrículos direito (ITSVD) e esquerdo (ITSVE) diminuíram durante o sangramento, mas aumentaram após a reposição, com o ITSVD em níveis superiores aos do controle e o ITSVE em níveis semelhantes aos do controle. A VPS e ddown aumentaram progressivamente durante o sangramento e diminuíram após a reposição, mas mantendo-se em valores superiores aos do controle. As maiores correlações de VPS e ddown foram com IS, PAPO, PAD e ITSVE. CONCLUSÕES: No cão, nas condições empregadas, a VPS e sua derivada ddown são indicadoras precoces de hipovolemia e guias sensíveis de reposição volêmica com SHD.