766 resultados para Água Azul do Norte - PA
Resumo:
Brazil has vast amounts of hydric resources, whose quality has been deteriorating due to pollutant dumping. Household waste disposal is one of the main sources of water pollution, stimulating bacteria proliferation and introducing microorganisms, including those from fecal matter. Conventional water disinfection methods are a solution, but on the downside, they lead to the formation byproducts hazardous to human health. In this study, aiming to develop bactericidal filters for the disinfection of drinking water; silver nanoparticles were deposited on alumina foams through three routes: sputtering DC, dip coating and in situ chemical reduction of silver nitrate. The depositions were characterized through X-ray diffraction, scanning electron microscopy and EDS element mapping. The influence of the depositions on permeability and mechanical properties of the ceramic foams was assessed and, in sequence, a preliminary antibacterial efficiency analysis was carried out. Characterization results indicate that the chemical reduction routes were efficient in depositing homogeneously distributed silver particles and that the concentration of the metallic precursor salt affects size and morphology of the particles. The antibacterial efficiency analysis indicates that the chemical reduction filters have potential for water disinfection
Resumo:
The state of Rio Grande do Norte presents a great potentiality for the production of ceramic tiles because of having natural raw material in quantity and quality making its economical exploration possible, beyond the great energetic differential of the state, the natural gás. This works aims to study the influence of the dolomite and granulometry concentration and calcinations temperature in the obtaining of formulations for porous coverings which have to be coherent to the project,s specifications. The experiments have involved the physical-chemical and mineralogical characterizations of raw materials and mechanical tests in the dry and burnt proof bodies preceding a mixture experiment planning with the use of the response surface methodology, in order to get the best raw materials combinations to produce a ceramic mass with specific properties. The twelve ceramic masses studied in this work were prepared by the via dry process, characterized, shaped by uniaxial pressing and sinterized in the temperatures of 940ºC, 1000ºC, 1060ºC, 1120ºC and 1180ºC, using a fast burning cycle. The crystalline phases formed during the sintering in the temperatures in study have revealed the presence of anorthite and diopside beyond quartz with a remaining phase. These phases were the main responsible ones by the physical- mechanical properties of the sinterized proof bodies. The proof bodies after the sintering stage have presented water absorption higher than 10% and a good dimensional stability in all studied temperatures. However, the flexural breaking strength results in the temperatures of 940ºC, 1000ºC and 1060ºC, under the temperature zone of the vitrification of ceramic whiteware do not reach the flexural breaking strength specific for the porous wall tile (15 MPa), but in the temperature of 1120ºC next to the vitrification temperature zone, some whiteware ceramic (formulations) has reached the specified value for the porous wall tile. The results of this work have showed that the studied raw materials have great importance for used in the production of porous wall tiles (BIII)
Resumo:
The production of water has become one of the most important wastes in the petroleum industry, specifically in the up stream segment. The treatment of this kind of effluents is complex and normally requires high costs. In this context, the electrochemical treatment emerges as an alternative methodology for treating the wastewaters. It employs electrochemical reactions to increase the capability and efficiency of the traditional chemical treatments for associated produced water. The use of electrochemical reactors can be effective with small changes in traditional treatments, generally not representing a significant additional surface area for new equipments (due to the high cost of square meter on offshore platforms) and also it can use almost the same equipments, in continuous or batch flow, without others high costs investments. Electrochemical treatment causes low environmental impact, because the process uses electrons as reagent and generates small amount of wastes. In this work, it was studied two types of electrochemical reactors: eletroflocculation and eletroflotation, with the aim of removing of Cu2+, Zn2+, phenol and BTEX mixture of produced water. In eletroflocculation, an electrical potential was applied to an aqueous solution containing NaCl. For this, it was used iron electrodes, which promote the dissolution of metal ions, generating Fe2+ and gases which, in appropriate pH, promote also clotting-flocculation reactions, removing Cu2+ and Zn2+. In eletroflotation, a carbon steel cathode and a DSA type anode (Ti/TiO2-RuO2-SnO2) were used in a NaCl solution. It was applied an electrical current, producing strong oxidant agents as Cl2 and HOCl, increasing the degradation rate of BTEX and phenol. Under different flow rates, the Zn2+ was removed by electrodeposition or by ZnOH formation, due the increasing of pH during the reaction. To better understand the electrochemical process, a statistical protocol factor (22) with central point was conducted to analyze the sensitivity of operating parameters on removing Zn2+ by eletroflotation, confirming that the current density affected the process negatively and the flow rate positively. For economical viability of these two electrochemical treatments, the energy consumption was calculated, taking in account the kWh given by ANEEL. The treatment cost obtained were quite attractive in comparison with the current treatments used in Rio Grande do Norte state. In addition, it could still be reduced for the case of using other alternative energy source such as solar, wind or gas generated directly from the Petrochemical Plant or offshore platforms
Resumo:
Until the early 90s, the simulation of fluid flow in oil reservoir basically used the numerical technique of finite differences. Since then, there was a big development in simulation technology based on streamlines, so that nowadays it is being used in several cases and it can represent the physical mechanisms that influence the fluid flow, such as compressibility, capillarity and gravitational segregation. Streamline-based flow simulation is a tool that can help enough in waterflood project management, because it provides important information not available through traditional simulation of finite differences and shows, in a direct way, the influence between injector well and producer well. This work presents the application of a methodology published in literature for optimizing water injection projects in modeling of a Brazilian Potiguar Basin reservoir that has a large number of wells. This methodology considers changes of injection well rates over time, based on information available through streamline simulation. This methodology reduces injection rates in wells of lower efficiency and increases injection rates in more efficient wells. In the proposed model, the methodology was effective. The optimized alternatives presented higher oil recovery associated with a lower water injection volume. This shows better efficiency and, consequently, reduction in costs. Considering the wide use of the water injection in oil fields, the positive outcome of the modeling is important, because it shows a case study of increasing of oil recovery achieved simply through better distribution of water injection rates
Resumo:
Boron is a semi-metal present in certain types of soils and natural waters. It is essential to the healthy development of plants and non-toxic to humans, depending on its concentration. It is used in various industries and it s present in water production coming from oil production. More specifically in Rio Grande do Norte, one of the largest oil producers on shore of Brazil, the relationship water/oil in some fields becomes more than 90%. The most common destination of this produced water is disposal in open sea after processing to meet the legal specification. In this context, this research proposes to study the extraction of boron in water produced by microemulsion systems for industrial utilization. It was taken into account the efficiency of extraction of boron related to surfactant (DDA and OCS, both characterized by FT-IR), cosurfactant (butanol and isoamyl alcohol), organic phase (kerosene and heptanes) and aqueous phase (solution of boron 3.6 ppm in alkaline pH). The ratio cosurfactant/ surfactant used was four and the percentage of organic phases for all points of study was set at 5%. It was chosen points with the highest percentage of aqueous phase. Each system was designed for three points of different compositions in relation to the constituents of a pseudoternary diagram. These points were chosen according to studies of phase behavior in pseudoternary diagrams made in previous studies. For this research, points were chosen in the Winsor II region. The excess aqueous solution obtained in these systems was separated and analyzed by ICP OES. For the data set obtained, the better efficiency in the extraction of boron was obtained using the system with DAC, isoamyl alcohol and heptanes, which extracted 49% in a single step. OCS was not viable to the extraction of boron by microemulsion system in the conditions defined in this study
Resumo:
Waste generated during the exploration and production of oil, water stands out due to various factors including the volume generated, the salt content, the presence of oil and chemicals and the water associated with oil is called produced water. The chemical composition of water is complex and depends strongly on the field generator, because it was in contact with the geological formation for thousands of years. This work aims to characterize the hydrochemical water produced in different areas of a field located in the Potiguar Basin. We collected 27 samples from 06 zones (400, 600, 400/600, 400/450/500, 350/400, A) the producing field called S and measured 50 required parameter divided between physical and chemical parameters, cations and anions. In hydrochemical characterization was used as tools of reasons ionic calculations, diagrams and they hydrochemical classification diagram Piper and Stiff diagram and also the statistic that helped in the identification of signature patterns for each production area including the area that supplies water injected this field for secondary oil recovery. The ionic balance error was calculated to assess the quality of the results of the analysis that was considered good, because 89% of the samples were below 5% error. Hydrochemical diagrams classified the waters as sodium chloride, with the exception of samples from Area A, from the injection well, which were classified as sodium bicarbonate. Through descriptive analysis and discriminant analysis was possible to obtain a function that differs chemically production areas, this function had a good hit rate of classification was 85%
Resumo:
Water injection is the most widely used method for supplementary recovery in many oil fields due to various reasons, like the fact that water is an effective displacing agent of low viscosity oils, the water injection projects are relatively simple to establish and the water availability at a relatively low cost. For design of water injection projects is necessary to do reservoir studies in order to define the various parameters needed to increase the effectiveness of the method. For this kind of study can be used several mathematical models classified into two general categories: analytical or numerical. The present work aims to do a comparative analysis between the results presented by flow lines simulator and conventional finite differences simulator; both types of simulators are based on numerical methods designed to model light oil reservoirs subjected to water injection. Therefore, it was defined two reservoir models: the first one was a heterogeneous model whose petrophysical properties vary along the reservoir and the other one was created using average petrophysical properties obtained from the first model. Comparisons were done considering that the results of these two models were always in the same operational conditions. Then some rock and fluid parameters have been changed in both models and again the results were compared. From the factorial design, that was done to study the sensitivity analysis of reservoir parameters, a few cases were chosen to study the role of water injection rate and the vertical position of wells perforations in production forecast. It was observed that the results from the two simulators are quite similar in most of the cases; differences were found only in those cases where there was an increase in gas solubility ratio of the model. Thus, it was concluded that in flow simulation of reservoirs analogous of those now studied, mainly when the gas solubility ratio is low, the conventional finite differences simulator may be replaced by flow lines simulator the production forecast is compatible but the computational processing time is lower.
Resumo:
Currently, the oil industry is the biggest cause of environmental pollution. The objective was to reduce the concentration of copper and chromium in the water produced by the oil industry. It was used as adsorbent natural sisal fiber Agave sp treated with nitric acid and sodium hydroxide. All vegetable fibers have physical and morphological properties that enablies the adsorption of pollutants. The basic composition of sisal is cellulose, hemicellulose and lignin. The features are typically found in the characterization of vegetable fibers, except the surface area that was practically zero. In the first stage of adsorption, it was evaluated the effect of temperature and time skeeking to optimize the execution of the factorial design. The results showed that the most feasible fiber was the one treated with acid in five hours (30°C). The second phase was a factorial design, using acid and five hours, this time was it determined in the first phase. The tests were conducted following the experimental design and the results were analyzed by statistical methods in order to optimize the main parameters that influence the process: pH, concentration (mol / L) and fiber mass/ metal solution volume. The volume / mass ratio factor showed significant interference in the adsorption process of chromium and copper. The results obtained after optimization showed that the highest percentages of extraction (98%) were obtained on the following operating conditions: pH: 5-6, Concentration: 100 ppm and mass/ volume: 1 gram of fiber/50mL solution. The results showed that the adsorption process was efficient to remove chromium and copper using sisal fibers, however, requiring further studies to optimize the process.
Resumo:
Among the different types of pollutants typically attributed to human activities, the petroleum products are one of the most important because of its toxic potential. This toxicity is attributed to the presence of substances such as benzene and its derivatives are very toxic to the central nervous system of man, with chronic toxicity, even in small concentrations. The area chosen for study was the city of Natal, capital of Rio Grande do Norte, where samples were collected in six different areas in the city, comprising 10 wells located in the urban area, being carried out in three distinct periods March/2009, December / June/2010 and 2009, and were evaluated for contamination by volatile hydrocarbons (BTEX - benzene, toluene, ethylbenzene and xylenes), so this work aimed to assess the quality of groundwater wells that supply funding for public supply and trade in the urban area of the city of Natal, in Rio Grande do Norte, contributing to the environmental assessment of the municipality. The analysis of BTEX in water was performed according to EPA Method 8021b. Was used the technique of headspace (TriPlus TP100) coupled to high resolution gas chromatography with selective photoionization detector (PID) and flame ionization (FID) - model Trace GC Ultra, Thermo Electron Corporation brand. The procedure adopted allowed the detection of concentrations of the order of μg.L-1. Data analysis with respect to BTEX in groundwater in the area monitored so far, shows that water quality is still preserved, because it exceeds the limits imposed by the potability Resolution CONAMA Nº. 396, April 2008
Resumo:
Oil recovery using waterflooding has been until now the worldwide most applied method, specially for light oil recovery, its success is mainly because of the low costs involved and the facilities of the injection process. The Toe- To-Heel Waterflooding TTHWTM method uses a well pattern of vertical injector wells completed at the bottom of the reservoir and horizontal producer wells completed at the top of it. The main producing mechanism is gravitational segregation in short distance. This method has been studied since the early 90´s and it had been applied in Canada with positive results for light heavy oils, nevertheless it hasn´t been used in Brazil yet. In order to verify the applicability of the process in Brazil, a simulation study for light oil was performed using Brazilian northwest reservoirs characteristics. The simulations were fulfilled using the STARS module of the Computer Modelling Group Software, used to perform improved oil recovery studies. The results obtained in this research showed that the TTHWTM well pattern presented a light improvement in terms of recovery factor when compared to the conventional 5- Spot pattern, however, it showed lower results in the economic evaluation
Resumo:
Produced water is characterized as one of the most common wastes generated during exploration and production of oil. This work aims to develop methodologies based on comparative statistical processes of hydrogeochemical analysis of production zones in order to minimize types of high-cost interventions to perform identification test fluids - TIF. For the study, 27 samples were collected from five different production zones were measured a total of 50 chemical species. After the chemical analysis was applied the statistical data, using the R Statistical Software, version 2.11.1. Statistical analysis was performed in three steps. In the first stage, the objective was to investigate the behavior of chemical species under study in each area of production through the descriptive graphical analysis. The second step was to identify a function that classify production zones from each sample, using discriminant analysis. In the training stage, the rate of correct classification function of discriminant analysis was 85.19%. The next stage of processing of the data used for Principal Component Analysis, by reducing the number of variables obtained from the linear combination of chemical species, try to improve the discriminant function obtained in the second stage and increase the discrimination power of the data, but the result was not satisfactory. In Profile Analysis curves were obtained for each production area, based on the characteristics of the chemical species present in each zone. With this study it was possible to develop a method using hydrochemistry and statistical analysis that can be used to distinguish the water produced in mature fields of oil, so that it is possible to identify the zone of production that is contributing to the excessive elevation of the water volume.
Resumo:
The retail fuel stations are partially or potentially polluters and generators of environmental accidents, potentially causing contamination of underground and surface water bodies, soil and air. Leaks in fuel retail stations´ underground storage systems are often detected in Brazil and around the world. Monoaromatic hydrocarbons, BTEX (benzene, toluene, ethylbenzene and xylenes) and polycyclic aromatic hydrocarbons (PAHs) are an indication of the presence of contamination due to its high toxicity. This paper presents a case study of contamination in a Fuel Retail Station by petroleum derivative products in the city of Natal. For identification and quantification of the hydrocarbons, EPA analytical methods were used. The values of benzene quantified by EPA method 8021b CG-PID/FID, ranged from 1.164 to 4.503 mg.Kg-1 in soil samples, and from 12.10 to 27,639 μg.L-1 in underground water samples. Among the PAHs, naphthalene and anthracene showed the most significant results in soil samples, 0.420 to 15.46 mg.Kg-1 and 0.110 to 0,970 mg.Kg-1, respectively. In underground water samples, the results for Naphthalene varied between 0.759 and 614.7 μg.L-1. PAHs were quantified by EPA Method 8270 for GCMS. All of the results for the chemical analysis were compared with the values for the CONAMA 420/2009 resolution. The results for benzene (27,639 μg.L-1) showed levels highly above the recommended by the CONAMA 420 resolution, wherein the maximum permissible for underground water is 5 μg.L-1. This is a worrying factor, since underground water makes up 70% of the city of Natal´s water supply
Resumo:
The produced water is a byproduct formed due to production of petroleum and carries with it a high amount of contaminants such as oil particles in suspension, organic compounds and metals. Thus, these latter pollutants are very difficult to treat because of its high solubility in water. The objective of this work is to use and evaluate a microemulsioned system to remove metals ( K , Mg , Ba , Ca , Cr , Mn , Li , Fe ) of synthetic produced water. For the extraction of metals, it was used a pseudoternary diagram containing the following phases: synthetic produced water as the aqueous phase (AP), hexane as organic phase (OP), and a cosurfactant/surfactant ratio equal to four (C/S = 4) as the third phase, where the OCS (saponified coconut oil) was used as surfactant and n-butanol as cosurfactant. The synthetic produced water was prepared in a bench scale and the region of interest in the diagram for the removal of metals was determined by experimental design called. Ten points located in the phase Winsor II were selected in an area with a large amount of water and small amounts of reagents. The samples were analyzed in atomic absorption spectrometer, and the results were evaluated through a statistical assesment, allowing the efficiency analysis of the effects and their interactions. The results showed percentages of extraction above 90% for the metals manganese, iron, chromium, calcium, barium and magnesium, and around 45% for metals lithium and potassium. The optimal point for the simultaneous removal of metals was calculated using statistical artifact multiple response function (MR). This calculation showed that the point of greatest extraction of metals occurs was the J point, with the composition [72% AP, 9% OP, 19% C/S], obtaining a global extraction percentage about 80%. Considering the aspects analyzed, the microemulsioned system has shown itself to be an effective alternative in the extraction of metals on synthetic produced water remediation
Resumo:
Ionic liquids (ILs) are organic compounds liquid at room temperature, good electrical conductors, with the potential to form as a means for electrolyte on electrolysis of water, in which the electrodes would not be subjected to such extreme conditions demanding chemistry [1]. This paper describes the synthesis, characterization and study of the feasibility of ionic liquid ionic liquid 1-methyl-3(2,6-(S)-dimethyloct-2-ene)-imidazole tetrafluoroborate (MDI-BF4) as electrolyte to produce hydrogen through electrolysis of water. The MDI-BF4 synthesized was characterized by thermal methods of analysis (Thermogravimetric Analysis - TG and Differential Scanning Calorimetry - DSC), mid-infrared spectroscopy with Fourier transform by method of attenuated total reflectance (FTIR-ATR), nuclear magnetic resonance spectroscopy of hydrogen (NMR 1H) and cyclic voltammetry (CV). Where thermal methods were used to calculate the yield of the synthesis of MDI-BF4 which was 88.84%, characterized infrared spectroscopy functional groups of the compound and the binding B-F 1053 cm-1; the NMR 1H analyzed and compared with literature data defines the structure of MDI-BF4 and the current density achieved by MDI-BF4 in the voltammogram shows that the LI can conduct electrical current indicating that the MDI-BF4 is a good electrolyte, and that their behavior does not change with the increasing concentration of water
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior