848 resultados para [JEL:J41] Labor and Demographic Economics - Particular Labor Markets - Contracts: Specific Human Capital, Matching Models, Efficiency Wage Models, and Internal Labor Markets


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Includes bibliography

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Includes bibliography

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Includes bibliography

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Includes bibliography

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Objective. This study aimed to investigate the stress distribution in screwed implant-supported prostheses with different implant-abutment connections by using a photoelastic analysis. Materials and methods. Four photoelastic models were fabricated in PL-2 resin and divided according to the implant-abutment connection (external hexagon (EH) and Morse taper (MT) implants (3.75 × 11.5 mm)) and the number crowns (single and 3-unit piece). Models were positioned in a circular polariscope and 100-N axial and oblique (45) loading were applied in the occlusal surface of the crowns by using a universal testing machine. The stresses were photographically recorded and qualitatively analyzed using software (Adobe Photoshop). Results. Under axial loading, the MT implants exhibited a lower number of fringes for single-unit crowns than EH implants, whereas for a 3-unit piece the MT implants showed a higher number of fringes vs EH implants. The oblique loading increased the number of fringes for all groups. Conclusion. In conclusion, the MT implant-abutment connection reduced the amount of stress in single-unit crowns, for 3-unit piece crowns the amount of stress was lower using an external hexagon connection. The stress pattern was similar for all groups. Oblique loading promoted a higher stress concentration than axial loading. © Informa Healthcare.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Com o objetivo de investigar a origem da mutação bS na população da região norte do Brasil, foram analisados polimorfismos de DNA no complexo de genes b da hemoglobina em 30 pacientes com anemia falciforme na população de Belém, a capital do Estado do Pará. Sessenta e sete por cento dos cromossomos bS analisados apresentaram o haplótipo Bantu, 30% o haplótipo Benin e 3% o haplótipo Senegal. A origem da mutação bS na população de Belém, estimada de acordo com a distribuição de haplótipos, não está de acordo com a esperada com base em dados históricos sobre o tráfico de escravos para a região norte, os quais indicam uma reduzida contribuição de escravos da região do Benin. Essas diferenças podem ser atribuídas ao tráfico interno de escravos, bem como ao posterior fluxo de populações imigrantes, particularmente de nordestinos. A distribuição de haplótipos em Belém não difere significativamente da observada em outras regiões brasileiras, muito embora os dados históricos sugiram que a maioria dos escravos procedentes da região do Atlântico-Oeste africano, onde predomina o haplótipo Senegal, foi trazida para o norte do Brasil, enquanto que o nordeste (Bahia, Pernambuco e Maranhão) recebeu o maior contingente de escravos oriundos da região centro-oeste africana, onde o haplótipo Benin é o mais comum. Nós sugerimos que as diferenças regionais quanto à procedência dos escravos africanos também foram modificadas pelo tráfico de escravos estabelecido entre as diferentes regiões brasileiras e posteriormente pelos movimentos migratórios.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The aim of this study was to perform a physicochemical and morphological characterization and compare the mechanical behavior of an experimental Ti-Mo alloy to the analogous metallic Ti-based fixation system, for mandibular angle fractures. Twenty-eight polyurethane mandibles were uniformly sectioned on the left angle. These were divided into 4 groups: group Eng 1P, one 2.0-mm plate and 4 screws 6 mm long; group Eng 2P, two 2.0-mm plates, the first fixed with 4 screws 6 mm long and the second with 4 screws 12 mm long. The same groups were created for the Ti-15Mo alloy. Each group was subjected to linear vertical loading at the first molar on the plated side in a mechanical testing unit. Means and standard deviations were compared with respect to statistical significance using ANOVA. The chemical composition of the Ti-15Mo alloy was close to the nominal value. The mapping of Mo and Ti showed a homogeneous distribution. SEM of the screw revealed machining debris. For the plates, only the cpTi plate undergoes a surface treatment. The metallographic analysis reveals granular microstructure, from the thermomechanical trials. A statistically significant difference was found (P < 0.05) when the comparison between both internal fixation techniques was performed. The 2P technique showed better mechanical behavior than 1P.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The aim of this in vitro study was to use strain gauge (SG) analysis to compare the effects of the implant-abutment joint, the coping, and the location of load on strain distribution in the bone around implants supporting 3-unit fixed partial prostheses. Three external hexagon (EH) implants and 3 internal hexagon (IH) implants were inserted into 2 polyurethane blocks. Microunit abutments were screwed onto their respective implant groups. Machined cobalt-chromium copings and plastic copings were screwed onto the abutments, which received standard wax patterns. The wax patterns were cast in a cobalt-chromium alloy (n = 5): group 1 = EH/machined. group 2 = EH/plastic, group 3 = IH/machined, and group 4 = IH/plastic. Four SGs were bonded onto the surface of the block tangentially to the implants. Each metallic structure was screwed onto the abutments and an axial load of 30 kg was applied at 5 predetermined points. The magnitude of microstrain on each SG was recorded in units of microstrain (mu epsilon). The data were analyzed using 3-factor repeated measures analysis of variance and a Tukey test (alpha = 0.05). The results showed statistically significant differences for the type of implant-abutment joint, loading point, and interaction at the implant-abutment joint/loading point. The IH connection showed higher microstrain values than the EH connection. It was concluded that the type of coping did not interfere in the magnitude of microstrain, but the implant/abutment joint and axial loading location influenced this magnitude.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

One to three percent of patients exposed to intravenously injected iodinated contrast media (CM) develop delayed hypersensitivity reactions. Positive patch test reactions, immunohistological findings, and CM-specific proliferation of T cells in vitro suggest a pathogenetic role for T cells. We have previously demonstrated that CM-specific T cell clones (TCCs) show a broad range of cross-reactivity to different CM. However, the mechanism of specific CM recognition by T cell receptors (TCRs) has not been analysed so far.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Smoking not only increases the risk that coronary heart disease will develop but also morbidity and mortality in patients with known coronary atherosclerosis and after coronary artery bypass grafting. Excessive generation of reactive oxygen species (ROS) has been implicated as the final common pathway for the development of endothelial dysfunction in various cardiovascular risk factors. This study assessed the influence of smoking on two different human arteries routinely used as coronary artery bypass graft conduits.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Bennett fractures are unstable, and, with inadequate treatment, lead to osteoarthritis, weakness and loss of function of the first carpometacarpal joint. This study focuses on long-term functional and radiological outcomes after open reduction and internal fixation.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

BACKGROUND AND PURPOSE: Recent studies have reported sex differences in recanalization and outcome after intravenous thrombolysis (IVT) in acute ischemic stroke. METHODS: We analyzed sex differences in outcome in consecutive patients with middle cerebral artery (MCA) M1 or M2 and internal carotid artery (ICA) occlusion treated with intra-arterial thrombolysis (IAT). Recanalization immediately after thrombolysis and outcome after 3 months were assessed. RESULTS: Two hundred five patients (111 men) with MCA and 43 (22 men) with ICA occlusion were identified. Baseline variables did not differ between the sexes except for a higher prevalence of smokers among men in the MCA group (31% vs 12%; P=0.001). Partial or complete recanalization (TIMI flow 2 or 3) of the MCA was observed in 71 (75%) women and 80 (72%) men (P=0.488). In the ICA group, 14 (67%) women and 11 men (50%) showed TIMI 2 or 3 recanalization (P=0.425). Favorable outcome (modified Rankin Scale score 0 to 2) was seen in 57 women (61%) and 63 men (57%) with MCA occlusion (P=0.512) and in 6 women (28%) and 4 men (18%) with ICA occlusion (P=0.656). After multiple-regression analyses, there was still no association between sex and outcome (P=0.763 for MCA and P=0.813 for ICA occlusion) or recanalization (P=0.488 for MCA and P=0.104 for ICA occlusion). CONCLUSIONS: There was no association between sex and recanalization or outcome after IAT. These findings are in contrast to previous studies reporting better recanalization and outcome after IVT in women and might have implications in the selection of patients for IAT or IVT.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The patency rate of radial artery (RA) conduits is considerably lower than that of internal thoracic artery (ITA) grafts and the evidence suggests that this is due to a clinically suspected higher incidence of vasospasm. The aim of this study was, therefore, to compare intraindividually the pharmacological reactivity of RA with that of ITA. Both RA and ITA were taken from the same patients and investigated in parallel. Changes in tone were monitored isometrically on ring preparations from both arteries in organ baths with modified Krebs-Henseleit solution containing 1.25 mm calcium chloride at 1 g passive preload. In intraindividual comparisons maximal receptor-mediated contractile responses to noradrenaline and endothelin-1 and endothelium-dependent acetylcholine-induced relaxant responses revealed no differences between both arteries. By contrast, depolarization-induced contractions to potassium chloride (KCl) appeared to be significantly higher in RA than in ITA. Further analysis, however, revealed that this difference was due to preoperative calcium entry blocker (Ca(2+)eB) therapy. Compared with control tissues, maximal responses to KCl were significantly attenuated in the ITA but unchanged in RA when arteries were obtained from patients with preoperative Ca(2+)eB therapy. The present results suggested that functional responses to pharmacological stimuli of both RA and ITA were quite similar. Preoperative Ca(2+)eB therapy, however, attenuated markedly responses to KCl of the ITA leaving those of RA unchanged. These results, demonstrating a lower sensitivity to Ca(2+)eB of RA, therefore suggested that in addition to Ca(2+)eB other classes of drug may be more effective at reducing the propensity of RA conduits to vasospasm.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Individual monitoring regulations in Switzerland are based on the ICRP60 recommendations. The annual limit of 20 mSv for the effective dose applies to the sum of external and internal radiation. External radiation is monitored monthly or quarterly with TLD, DIS or CR-39 dosemeters by 10 approved external dosimetry services and reported as H(p)(10) and H(p)(0.07). Internal monitoring is done in two steps. At the workplace, simple screening measurements are done frequently in order to recognise a possible incorporation. If a nuclide dependent activity threshold is exceeded then one of the seven approved dosimetry services for internal radiation does an incorporation measurement to assess the committed effective dose E(50). The dosimetry services report all the measured or assessed dose values to the employer and to the National Dose Registry. The employer records the annually accumulated dose values into the individual dose certificate of the occupationally exposed person, both the external dose H(p)(10) and the internal dose E(50) as well as the total effective dose E = H(p)(10)+E(50). Based on the national dose registry an annual report on the dosimetry in Switzerland is published which contains the statistics for the total effective dose, as well as separate statistics for external and internal exposure.