970 resultados para ultrafast ultrasound
Resumo:
Aortic stiffness is an independent predictor factor for cardiovascular risk. Different methods for determining pulse wave velocity (PWV) are used, among which the most common are mechanical methods such as SphygmoCor or Complior, which require specific devices and are limited by technical difficulty in obtaining measurements. Doppler guided by 2D ultrasound is a good alternative to these methods. We studied 40 patients (29 male, aged 21 to 82 years) comparing the Complior method with Doppler. Agreement of both devices was high (R = 0.91, 0.84-0.95, 95% CI). The reproducibility analysis revealed no intra-nor interobserver differences. Based on these results, we conclude that Doppler ultrasound is a reliable and reproducible alternative to other established methods for themeasurement of aortic PWV
Resumo:
BACKGROUND: Ultrasound Biomicroscopy (UBM) is a new ophthalmological imaging technique essentially designed for the study of the anterior eye segment. Over the last 10 months, we've evaluated its contribution to the conservative treatment of anterior uveal melanoma's by means of accelerated proton beam irradiation. MATERIAL: Using UBM, we have examined 55 cases of uveal melanoma's, whose anterior border was situated at 6 mm or less from the limbus and that were consequently treated by proton beam irradiation. RESULTS: The presumed tumoral origin was the ciliary body's pars plicata in 13 cases and the pars plana or the choroid in 42 cases, 17 of which presented a tumoral invasion of the pars plicata. A pars plana detachment anterior to or surrounding the anterior tumoral border, was present in 22 cases. The height of the tumor could only be measured by UBM if it was less than 2.5 mm. Information gathered using UBM have contributed to an improvement of the therapy plan in 32 cases. CONCLUSION: Because of the strong attenuation of the high frequency ultrasound signal, UBM can only be used for the examination of intra-ocular structures situated in direct neighbourhood to the global wall. Despite this technical limitation, ist contribution to the planning of the conservative treatment of anterior uveal melanoma's by proton beam irradiation has appeared to be considerable.
Resumo:
OBJECTIVE.: Injection of opioids to the superior cervical ganglion (SCG) has been reported to provide pain relief in patients suffering from different kinds of neuropathic facial pain conditions, such as trigeminal neuralgia, postherpetic neuralgia, and atypical facial pain. The classic approach to the SCG is a transoral technique using a so-called "stopper" to prevent accidental carotid artery puncture. The main disadvantage of this technique is that the needle tip is positioned distant from the actual target, possibly impeding successful block of the SCG. A further limitation is that injection of local anesthetics due to potential carotid artery puncture is contraindicated. We hypothesized that the SCG can be identified and blocked using ultrasound imaging, potentially increasing precision of this technique. INTERVENTIONS.: In this pilot study, 20 US-guided simulated blocks of the SCG were performed in 10 human cadavers in order to determine the accuracy of this novel block technique. After injection of 0.1 mL of dye, the cadavers were dissected to evaluate the needle position and coloring of the SCG. RESULTS.: Nineteen of the 20 needle tips were located in or next to the SCG. This corresponded to a simulated block success rate of 95% (95% confidence interval 85-100%). In 17 cases, the SCG was completely colored, and in two cases, the caudal half of the SCG was colored with dye. CONCLUSIONS.: The anatomical dissections confirmed that our ultrasound-guided approach to the SCG is accurate. Ultrasound could become an attractive alternative to the "blind" transoral technique of SCG blocks.
Resumo:
Purpose: To describe low mechanical index grey scale contrast enhanced breast ultrasound in patients with intraductal echogenic material in the differentiation of papillomas from intraductal secretions. Methods and materials: In five patients with echographically detected ductal dilatation containing echogenic material low mechanical index grey scale contrast enhanced ultrasonography was performed. No patient had nipple discharge. The examination was performed with a 9 MHz linear transducer after injection of 4 ml of Sonovue. It was assessed if contrast enhancement was present or not. The results were correlated with histologic results after surgical resection or percutaneous biopsy when performed. Results: In 3 patients contrast enhancement was observed. These patients were operated and the papillomas confirmed by histology. In two patients no contrast enhancement was observed. In one of these two patients percutaneous biopsy was performed without evidence of a papillary lesion. The second patient presented with multiple dilated ducts containing echogenic material. No biopsy was performed but breast MRI showed no intraductal enhancement supporting the non papillary nature of the intraductal material. Conclusion: This pilot study shows that contrast enhanced ultrasound is able to detect the vascularisation of papillomas and that it may differentiate intraductal papillomas from secretions.
Resumo:
OBJECTIVES: Ultrasound scan in the mid-trimester of pregnancy is now a routine part of prenatal care in most European countries. The objective of this study was to evaluate the prenatal diagnosis of dysmorphic syndromes by fetal ultrasound examination. METHODS: Data from 20 registries of congenital malformations in 12 European countries were included in the study. RESULTS: There were 2454 cases with congenital heart diseases, 479 of which were recognized syndromes, including 375 chromosomal anomalies and 104 syndromes without chromosomal anomalies. Fifty-one of the 104 were detected prenatally (49.0%). One hundred and ninety-two of 1130 cases with renal anomalies were recognized syndromes, including 128 chromosomal anomalies and 64 syndromes without chromosomal anomalies; 162 of them (84.4%) were diagnosed prenatally, including 109 chromosomal anomalies and 53 non-chromosomal syndromes. Fifty-four of the 250 cases with limb defects were recognized syndromes, including 16 chromosomal syndromes and 38 syndromes without chromosomal anomalies; 21 of these 54 syndromes were diagnosed prenatally (38.9%), including 9 chromosomal syndromes. There were 243 cases of abdominal wall defects including 57 recognizable syndromes, 48 with omphalocele and 9 with gastroschisis; 48 were diagnosed prenatally (84.2%). Twenty-six of the 187 cases with diaphragmatic hernia had recognized syndromes, including 20 chromosomal aberrations and 6 syndromes without chromosomal anomalies. Twenty-two of them (84.6%) were detected prenatally. Sixty-four of 349 cases with intestinal anomalies were recognized syndromes; 24 were diagnosed prenatally (37.5%). There were 553 cases of cleft lip and palate (CL(P)) and 198 of cleft palate (CP) including 74 chromosomal anomalies and 73 recognized non-chromosomal syndromes. Prenatal diagnosis was made in 51 cases of CL(P) (53.7%) and 7 of CP (13.7%). Twenty-two of 188 anencephalic cases were syndromic and all were diagnosed prenatally. Of 290 cases with spina bifida, 18 were recognized syndromes, and of them 17 were diagnosed prenatally. All 11 syndromic encephaloceles were diagnosed prenatally. CONCLUSIONS: Around 50% of the recognized syndromes which are associated with major congenital anomalies (cardiac, renal, intestinal, limb defects, abdominal wall defects and oral clefts) can be detected prenatally by the anomaly scan. However the detection rate varies with the type of syndrome and with the different countries' policies of prenatal screening.
Resumo:
The information gathered with intravascular ultrasound (IVUS) are of great value in endovascular techniques. The aim of this study was to evaluate the reliability of IVUS when measuring vessel dimensions by comparison with an established reference method. The left carotid artery was exposed in 4 pigs (45-55 kg) and two piezoelectric crystals were sutured on the adventitia in the same cross-sectional plane. The distance between them was measured either by IVUS and by sonomicrometers. The mean distance between the two crystals calculated by the sonomicrometer was 4.7+/-0.4 mm (mean systolic distance was 4.9+/-0.2 mm, mean diastolic distance was 4.6+/-0.1 mm). The mean distance between the two targets calculated by IVUS was 4. 5+/-0.2 mm (mean systolic distance was 4.6+/-0.2 mm and mean diastolic 4.4+/-0.2 mm). Regression analysis of the two series of data shows a R(2)=0.9984. IVUS measurements are an average 5% smaller than sonomicrometer measurements (3.6% up to 8.3%) and the difference is statistically significant ( p <0.05). The underestimation of IVUS measurements will affect the accuracy, and probably the long-term outcome, of endovascular procedures.
Resumo:
Background: Few studies have used longitudinal ultrasound measurements to assess the effect of traffic-related air pollution on fetal growth.Objective: We examined the relationship between exposure to nitrogen dioxide (NO2) and aromatic hydrocarbons [benzene, toluene, ethylbenzene, m/p-xylene, and o-xylene (BTEX)] on fetal growth assessed by 1,692 ultrasound measurements among 562 pregnant women from the Sabadell cohort of the Spanish INMA (Environment and Childhood) study.Methods: We used temporally adjusted land-use regression models to estimate exposures to NO2 and BTEX. We fitted mixed-effects models to estimate longitudinal growth curves for femur length (FL), head circumference (HC), abdominal circumference (AC), biparietal diameter (BPD), and estimated fetal weight (EFW). Unconditional and conditional SD scores were calculated at 12, 20, and 32 weeks of gestation. Sensitivity analyses were performed considering time–activity patterns during pregnancy.Results: Exposure to BTEX from early pregnancy was negatively associated with growth in BPD during weeks 20–32. None of the other fetal growth parameters were associated with exposure to air pollution during pregnancy. When considering only women who spent 2 hr/day in nonresidential outdoor locations, effect estimates were stronger and statistically significant for the association between NO2 and growth in HC during weeks 12–20 and growth in AC, BPD, and EFW during weeks 20–32.Conclusions: Our results lend some support to an effect of exposure to traffic-related air pollutants from early pregnancy on fetal growth during mid-pregnancy.
Resumo:
Human arteries affected by atherosclerosis are characterized by altered wall viscoelastic properties. The possibility of noninvasively assessing arterial viscoelasticity in vivo would significantly contribute to the early diagnosis and prevention of this disease. This paper presents a noniterative technique to estimate the viscoelastic parameters of a vascular wall Zener model. The approach requires the simultaneous measurement of flow variations and wall displacements, which can be provided by suitable ultrasound Doppler instruments. Viscoelastic parameters are estimated by fitting the theoretical constitutive equations to the experimental measurements using an ARMA parameter approach. The accuracy and sensitivity of the proposed method are tested using reference data generated by numerical simulations of arterial pulsation in which the physiological conditions and the viscoelastic parameters of the model can be suitably varied. The estimated values quantitatively agree with the reference values, showing that the only parameter affected by changing the physiological conditions is viscosity, whose relative error was about 27% even when a poor signal-to-noise ratio is simulated. Finally, the feasibility of the method is illustrated through three measurements made at different flow regimes on a cylindrical vessel phantom, yielding a parameter mean estimation error of 25%.
Resumo:
Introduction: Surgery represents the treatment of choice for localized renal cell neoplasia. Partial nephrectomy (PN) has widened its indications over the past two decades and has shown oncological results equivalent to radical nephrectomy for small tumors. The role of negative surgical margins has been widely debated. Intraoperative fresh frozen section analysis is shown to be unreliable, expensive, time-consuming and not well correlated to final pathology. The goal of the present study was to assess the feasibility of intraoperative ex-vivo ultrasound (US) control of resection margins and its correlation to margin status at definitive pathology in patients undergoing PN.Material and Methods: The study was carried out in our institution from February 2008 to March 2010. Patients undergoing PN for T1-T2 renal tumors were included. Ex vivo US was performed by one single senior radiologist. Considering its availability, not all consecutive eligible patients were included. PN was undertaken in a standardized technique applying the "minimal healthy tissue margin" technique. Once resected, the specimen was kept in a saline solution and ex-vivo US was performed to evaluate the whole tumor pseudocapsule.Results: Twelve patients (five women, age (mean}SD) 65}11 years) were included. Intraoperative ex-vivo US showed negative surgical margin in all cases. US duration ranged from 1 to 4 minutes, with a median time of 1 minute. Definitive histological analysis confirmed the presence of two angiomyolipoma, eight pT1a tumors, of which seven were clear cell carcinoma and one was a type II papillary tumor, one pT1b clear cell carcinoma and one pT2 chromophobe carcinoma (size 2.9}2.3 cm). Final pathology revealed R0 margins.Conclusion: Intraoperative ex-vivo US control of resection margins in patients undergoing PN is feasible, time-efficient and well correlated to definitive pathological examination with regards to margin status.
Resumo:
Dietary acid load from Western diets may be a risk factor for osteoporosis. It can be estimated by net endogenous acid production (NEAP). No data currently exists for NEAP estimates and bone indices in the very elderly (i.e. > or = 75 y). The aim of this study was to determine the association between NEAP estimates by using the potential renal acid load (PRAL) equation and quantitative bone ultrasound (QUS) measurements at the heel [broadband ultrasound attenuation (BUA)] in Caucasian women. We assessed NEAP and QUS in 401 very elderly Swiss ambulatory women. We evaluated dietary intake and NEAP estimates with a validated FFQ. QUS was measured using Achilles (Lunar). We identified 2 subgroups: 256 women (80.6 y +/- 3; BUA, 96.8 dB/MHz) with a fracture history and the remaining 145 (79.9 y SD 2.9; BUA, 101.7 dB/MHz) without. Women who reported having suffered a fracture had lower BUA (P < 0.001) than nonfractured women but did not differ in nutrient intakes and NEAP. Lower NEAP (P = 0.023) and higher potassium intake (P = 0.033) were correlated with higher BUA, which remained significant even after adjustment for age, BMI, and osteoporosis treatment. BUA was positively correlated with calcium (P = 0.016) and BMI (P < 0.001). Women who reported no fractures had no significant correlations between nutrient intake, NEAP, and BUA. Low nutritional acid load was correlated with higher BUA in very elderly women with a fracture history. Although relatively weak compared with age and BMI, this association was significant and may be an important additional risk factor that might be particularly relevant in frail patients with an already high fracture risk.
Resumo:
BACKGROUND: We examined whether making smokers aware that they had developed peripheral atherosclerosis would improve smoking cessation. METHODS: Smokers selected from the general population were randomly allocated to undergo high-resolution B-mode ultrasonography of their carotid and femoral arteries. All smokers received quit-smoking counseling. Smokers with > or =1 atherosclerotic plaque were given two photographs of a plaque with a relevant explanation. Quit rates were assessed by telephone 6 months later. RESULTS: Seventy-nine smokers did not undergo ultrasonography (A). Among the 74 smokers submitted to ultrasonography, 20 had no plaque (B) and 54 had > or =1 plaque (C). Quit rates were, respectively, 6.3, 5.0, and 22.2% in groups A, B, and C. Quit rates were higher in smokers submitted to ultrasonography (B + C vs A; P = 0.031) and in those receiving photographs (C vs A + B; P = 0.003). Smoking cessation was independently associated with intervention C (OR = 6.2; 95% CI = 1.8-21) and a white-collar job but not with age or gender. CONCLUSIONS: Providing smokers with photographs demonstrating atherosclerosis on their own person was an effective adjunct to physician's advice to quit smoking. Since ultrasonography is used increasingly often in clinical practice for cardiovascular risk stratification, this can provide an additional opportunity and means to deter smokers from smoking.