139 resultados para substation
Resumo:
The Virtual Reality techniques applied in Electricity Environments provide a new supervisory control paradigm. The fact of existing a virtual environment (VE), geometrically similar to a real substation, reduces the difference of mental models built by field operators compared with those built by system center operation improving the communication. Beside this, those systems can be used as visualization interfaces for electricity system simulators, training systems for professors and undergraduate students, field operators and maintenance professionals. However, the development process of these systems is quite complex, combining several activities such as implementation, 3D modeling, virtual sceneries construction, usability assessment and management project techniques. In this context, this work present a GUI strategy to build field arrangements based on scene graphs, to reduce time in Virtual Electricity Substations Arrangement development. Through this, mistakes during the VE building can be avoided making this process more reliable. As an concept proof, all toolkits developed in this work were applied in the virtualization of the substations from a Brazilian power concessionary named CEMIG.
Resumo:
Automatic load transfer (ALT) on the 11 kV network is the process by which circuit breakers on the network are switched to form open points in order to feed load from different primary substations. Some of the potential benefits that may be gained from dynamically using ALT include maximising utilisation of existing assets, voltage regulation and reduced losses. One of the key issues, that has yet to be properly addressed in published research, is how to validate that the modelled benefits really exist. On an 11 kV distribution network where the load is continually changing and the load on each distribution substation is unlikely to be monitored - reduction in losses from moving the normally open point is particularly difficult to prove. This study proposes a method to overcome this problem and uses measured primary feeder data from two parts of the Western Power Distribution 11 kV Network under different configurations. The process of choosing the different configurations is based on a heuristic modelling method of locating minimum voltages to help reduce losses.
Resumo:
Emerging cybersecurity vulnerabilities in supervisory control and data acquisition (SCADA) systems are becoming urgent engineering issues for modern substations. This paper proposes a novel intrusion detection system (IDS) tailored for cybersecurity of IEC 61850 based substations. The proposed IDS integrates physical knowledge, protocol specifications and logical behaviours to provide a comprehensive and effective solution that is able to mitigate various cyberattacks. The proposed approach comprises access control detection, protocol whitelisting, model-based detection, and multi-parameter based detection. This SCADA-specific IDS is implemented and validated using a comprehensive and realistic cyber-physical test-bed and data from a real 500kV smart substation.
Resumo:
The system grounding method option has a direct influence on the overall performance of the entire medium voltage network as well as on the ground fault current magnitude. For any kind of grounding systems: ungrounded system, solidly and low impedance grounded and resonant grounded, we can find advantages and disadvantages. A thorough study is necessary to choose the most appropriate grounding protection system. The power distribution utilities justify their choices based on economic and technical criteria, according to the specific characteristics of each distribution network. In this paper we present a medium voltage Portuguese substation case study and a study of neutral system with Petersen coil, isolated neutral and impedance grounded.