961 resultados para stent-grafts
Resumo:
To investigate the ability of SYNTAX score and Clinical SYNTAX score (CSS) to predict very long-term outcomes in an all-comers population receiving drug-eluting stents.
Resumo:
Background: The SYNTAX score (SXscore) has been shown to be an effective predictor of clinical outcomes in patients undergoing percutaneous coronary intervention (PCI).
Methods and results: The SXscore was prospectively collected in 1,397 of the 1,707 patients enrolled in the “all-comers” LEADERS trial (patients post-surgical revascularisation were excluded). Post hoc analysis was performed by stratifying clinical outcomes at two-year follow-up, according to one of three SXscore tertiles:
SXlow ≤8 (n=464), 8
Resumo:
This study sought to assess the impact of the SYNTAX (Synergy Between Percutaneous Coronary Intervention With Taxus and Cardiac Surgery) score (SXscore) on clinical outcomes in patients undergoing percutaneous coronary intervention.
Resumo:
Aims To compare the tissue coverage of a hydrophilic polymer-coated zotarolimus-eluting stent (ZES) vs. a fluoropolymer-coated everolimus-eluting stent (EES) at 13 months, using optical coherence tomography (OCT) in an ‘all-comers' population of patients, in order to clarify the mechanism of eventual differences in the biocompatibility and thrombogenicity of the devices. Methods and results Patients randomized to angiographic follow-up in the RESOLUTE All Comers trial (NCT00617084) at pre-specified OCT sites underwent OCT follow-up at 13 months. Tissue coverage and apposition were assessed strut by strut, and the results in both treatment groups were compared using multilevel logistic or linear regression, as appropriate, with clustering at three different levels: patient, lesion, and stent. Fifty-eight patients (30 ZES and 28 EES), 72 lesions, 107 stents, and 23 197 struts were analysed. Eight hundred and eighty-seven and 654 uncovered struts (7.4 and 5.8%, P= 0.378), and 216 and 161 malapposed struts (1.8 and 1.4%, P= 0.569) were found in the ZES and EES groups, respectively. The mean thickness of coverage was 116 ± 99 µm in ZES and 142 ± 113 µm in EES (P= 0.466). No differences in per cent neointimal volume obstruction (12.5 ± 7.9 vs. 15.0 ± 10.7%) or other areas–volumetric parameters were found between ZES and EES, respectively. Conclusion No significant differences in tissue coverage, malapposition, or lumen/stent areas and volumes were detected by OCT between the hydrophilic polymer-coated ZES and the fluoropolymer-coated EES at 13-month follow-up.
Resumo:
The aim of this study was to investigate the impact of patient and lesion complexity on outcomes with newer-generation zotarolimus-eluting stents (ZES) and everolimus-eluting stents (EES).
Resumo:
In the RESOLUTE All Comers trial, the Resolute zotarolimus-eluting stent was non-inferior to the Xience V everolimus-eluting stent for the primary stent-related endpoint of target lesion failure (cardiac death, target vessel myocardial infarction, and ischaemia-driven target lesion revascularisation) at 1 year. However, data for long-term safety and efficacy from randomised studies of new generation drug-eluting coronary stents in patients treated in routine clinical practice are scarce. We report the prespecified 2-year clinical outcomes from the RESOLUTE All Comers trial.
Resumo:
The ABSORB cohort A trial using the bioresorbable everolimus-eluting scaffold (BVS revision 1.0, Abbott Vascular) demonstrated a slightly higher acute recoil with BVS than with metallic stents. To reinforce the mechanical strength of the scaffold, the new BVS scaffold (revision 1.1) with modified strut design was developed and tested in the ABSORB cohort B trial. This study sought to evaluate and compare the in vivo acute scaffold recoil of the BVS revision 1.0 in ABSORB cohort A and the BVS revision 1.1 in ABSORB cohort B with the historical recoil of the XIENCE V® everolimus-eluting metal stent (EES, SPIRIT I and II).
Resumo:
Compared with bare metal stents (BMS), early generation drug-eluting stents (DES) reduce the risk of revascularisation in patients with ST-elevation myocardial infarction (STEMI) at the expense of an increased risk of very late stent thrombosis (ST). Durable polymer coatings for controlled drug release have been identified as a potential trigger for these late adverse events and this has led to the development of newer generation DES with durable and biodegradable polymer surface coatings with improved biocompatibility. In a recent all-comers trial, biolimus-eluting stents with a biodegradable polymer surface coating were found to reduce the risk of very late ST by 80% compared with sirolimus-eluting stents with durable polymer, which also translated into a lower risk of cardiac death and myocardial infarction (MI) beyond one year.
Resumo:
Early-generation drug-eluting stents releasing sirolimus (SES) or paclitaxel (PES) are associated with increased risk of very late stent thrombosis occurring >1 year after stent implantation. It is unknown whether the risk of very late stent thrombosis persists with newer-generation everolimus-eluting stents (EES).
Resumo:
The efficacy of durable polymer drug-eluting stents (DES) is delivered at the expense of delayed healing of the stented vessel. Biodegradable polymer DES aim to avoid this shortcoming and may potentially improve long-term clinical outcomes, with benefit expected to accrue over time. We sought to compare long-term outcomes in patients treated with biodegradable polymer DES vs. durable polymer sirolimus-eluting stents (SES).
Resumo:
To evaluate the effectiveness and safety of covered stents for the management of iatrogenic arterial injury.
Resumo:
The relative safety of drug-eluting stents and bare-metal stents, especially with respect to stent thrombosis, continues to be debated. In view of the overall low frequency of stent thrombosis, large sample sizes are needed to accurately estimate treatment differences between stents. We compared the risk of thrombosis between bare-metal and drug-eluting stents.
Resumo:
The use of a coronally advanced flap (CAF) and connective tissue graft (CTG) is a well-established procedure to cover single and multiple recessions and improve soft tissue esthetics. However, until now, there are still limited data evaluating patient morbidity, the fear of imminent tooth loss, and modification of sensitivity in surgical areas. The aim of the present study was to evaluate the patient-centered outcomes associated with CAF + CTG.
Transposition of the supra-aortic vessels before stent grafting the aortic arch and descending aorta
Resumo:
Thoracic endovascular aortic repair has broadened the spectrum of treatment options for various acute and chronic thoracic aortic diseases. In clinical practice, aneurysms of the descending aorta are rarely limited to 1 segment. Thus, various surgical and endovascular options have been developed to offer treatment to those patients with more extended descending thoracic aortic disease. We have summarized the most common methods of arch rerouting, depending on the aortic involvement, emphasizing that these techniques should be used very selectively by experienced cardiovascular surgery teams.