932 resultados para standard certification


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Gene therapy approaches using recombinant adeno-associated virus serotype 2 (rAAV2) and serotype 8 (rAAV8) have achieved significant clinical benefits. The generation of rAAV Reference Standard Materials (RSM) is key to providing points of reference for particle titer, vector genome titer, and infectious titer for gene transfer vectors. Following the example of the rAAV2RSM, here we have generated and characterized a novel RSM based on rAAV serotype 8. The rAAV8RSM was produced using transient transfection, and the purification was based on density gradient ultracentrifugation. The rAAV8RSM was distributed for characterization along with standard assay protocols to 16 laboratories worldwide. Mean titers and 95% confidence intervals were determined for capsid particles (mean, 5.50×10(11) pt/ml; CI, 4.26×10(11) to 6.75×10(11) pt/ml), vector genomes (mean, 5.75×10(11) vg/ml; CI, 3.05×10(11) to 1.09×10(12) vg/ml), and infectious units (mean, 1.26×10(9) IU/ml; CI, 6.46×10(8) to 2.51×10(9) IU/ml). Notably, there was a significant degree of variation between institutions for each assay despite the relatively tight correlation of assay results within an institution. This outcome emphasizes the need to use RSMs to calibrate the titers of rAAV vectors in preclinical and clinical studies at a time when the field is maturing rapidly. The rAAV8RSM has been deposited at the American Type Culture Collection (VR-1816) and is available to the scientific community.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

An objective analysis of image quality parameters was performed for a computed radiography (CR) system using both standard single-side and prototype dual-side read plates. The pre-sampled modulation transfer function (MTF), noise power spectrum (NPS), and detective quantum efficiency (DQE) for the systems were determined at three different beam qualities representative of pediatric chest radiography, at an entrance detector air kerma of 5 microGy. The NPS and DQE measurements were realized under clinically relevant x-ray spectra for pediatric radiology, including x-ray scatter radiations. Compared to the standard single-side read system, the MTF for the dual-side read system is reduced, but this is offset by a significant decrease in image noise, resulting in a marked increase in DQE (+40%) in the low spatial frequency range. Thus, for the same image quality, the new technology permits the CR system to be used at a reduced dose level.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND Data on which to base definitive recommendations on the doses and duration of therapy for genotype 3 HCV/HIV-coinfected patients are scarce. We evaluated the efficacy of a lower peginterferon-α 2a dose and a shorter duration of therapy than the current standard of care in genotype 3 HCV/HIV-coinfected patients. METHODS AND FINDINGS Pilot, open-label, single arm clinical trial which involved 58 Caucasian HCV/HIV-coinfected patients who received weekly 135 µg peginterferon-α 2a plus ribavirin 400 mg twice daily during 20 weeks after attaining undetectable viremia. The relationships between baseline patient-related variables, including IL28B genotype, plasma HCV-RNA, ribavirin dose/kg, peginterferon-α 2a and ribavirin levels with virological responses were analyzed. Only 4 patients showed lack of response and 5 patients dropped out due to adverse events related to the study medication. Overall, sustained virologic response (SVR) rates were 58.3% by intention-to-treat and 71.4% by per protocol analysis, respectively. Among patients with rapid virologic response (RVR), SVR and relapses rates were 92.6% and 7.4%, respectively. No relationships were observed between viral responses and ribavirin dose/kg, peginterferon-α 2a concentrations, ribavirin levels or rs129679860 genotype. CONCLUSIONS Weekly 135 µg pegIFN-α 2a could be as effective as the standard 180 µg dose, with a very low incidence of severe adverse events. A 24-week treatment duration appears to be appropriate in patients achieving RVR, but extending treatment up to just 20 weeks beyond negativization of viremia is associated with a high relapse rate in those patients not achieving RVR. There was no influence of IL28B genotype on the virological responses.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE: When treating peripheral ectatic disease-like pellucid marginal degeneration (PMD), corneal cross-linking with UV-A and riboflavin (CXL) must be applied eccentrically to the periphery of the lower cornea, partly irradiating the corneal limbus. Here, we investigated the effect of standard and double-standard fluence corneal cross-linking with riboflavin and UV-A (CXL) on cornea and corneal limbus in the rabbit eye in vivo. METHODS: Epithelium-off CXL was performed in male New Zealand White rabbits with two irradiation diameters (7 mm central cornea, 13 mm cornea and limbus), using standard fluence (5.4 J/cm(2)) and double-standard fluence (10.8 J/cm(2)) settings. Controls were subjected to epithelial removal and riboflavin instillation, but were not irradiated with UV-A. Following CXL, animals were examined daily until complete closure of the epithelium, and at 7, 14, 21, and 28 days. Animals were killed and a corneoscleral button was excised and processed for light microscopy and immunohistochemistry. RESULTS: For both irradiation diameters and fluences tested, no signs of endothelial damage or limbal vessel thrombosis were observed, and time to re-epithelialization was similar to untreated controls. Histological and immunohistochemical analysis revealed no differences in the p63 putative stem cell marker expression pattern. CONCLUSIONS: Even when using fluence twice as high as the one used in current clinical CXL settings, circumferential UV-A irradiation of the corneal limbus does not alter the regenerative capacity of the limbal epithelial cells, and the expression pattern of the putative stem cell marker p63 remains unchanged. This suggests that eccentric CXL may be performed safely in PMD.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

RATIONALE AND OBJECTIVES: Recent developments of magnetic resonance imaging enabled free-breathing coronary MRA (cMRA) using steady-state-free-precession (SSFP) for endogenous contrast. The purpose of this study was a systematic comparison of SSFP cMRA with standard T2-prepared gradient-echo and spiral cMRA. METHODS: Navigator-gated free-breathing T2-prepared SSFP-, T2-prepared gradient-echo- and T2-prepared spiral cMRA was performed in 18 healthy swine (45-68 kg body-weight). Image quality was investigated subjectively and signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR) and vessel sharpness were compared. RESULTS: SSFP cMRA allowed for high quality cMRA during free breathing with substantial improvements in SNR, CNR and vessel sharpness when compared with standard T2-prepared gradient-echo imaging. Spiral imaging demonstrated the highest SNR while image quality score and vessel definition was best for SSFP imaging. CONCLUSION: Navigator-gated free-breathing T2-prepared SSFP cMRA is a promising new imaging approach for high signal and high contrast imaging of the coronary arteries with improved vessel border definition.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper introduces the evaluation report after fostering a Standard-based Interoperability Framework (SIF) between the Virgen del Rocío University Hospital (VRUH) Haemodialysis (HD) Unit and 5 outsourced HD centres in order to improve integrated care by automatically sharing patients' Electronic Health Record (EHR) and lab test reports. A pre-post study was conducted during fourteen months. The number of lab test reports of both emergency and routine nature regarding to 379 outpatients was computed before and after the integration of the SIF. Before fostering SIF, 19.38 lab tests per patient were shared between VRUH and HD centres, 5.52 of them were of emergency nature while 13.85 were routine. After integrating SIF, 17.98 lab tests per patient were shared, 3.82 of them were of emergency nature while 14.16 were routine. The inclusion of a SIF in the HD Integrated Care Process has led to an average reduction of 1.39 (p=0.775) lab test requests per patient, including a reduction of 1.70 (p=0.084) in those of emergency nature, whereas an increase of 0.31 (p=0.062) was observed in routine lab tests. Fostering this strategy has led to the reduction in emergency lab test requests, which implies a potential improvement of the integrated care.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Hepatitis D virus (HDV) is endemic in the Amazon Region and its pathophysiology is the most severe among viral hepatitis. Treatment is performed with pegylated interferon and the immune response appears to be important for infection control. HDV patients were studied: untreated and polymerase chain reaction (PCR) positive (n = 9), anti-HDV positive and PCR negative (n = 8), and responders to treatment (n = 12). The cytokines, interleukin (IL)-2 (p = 0.0008) and IL-12 (p = 0.02) were differentially expressed among the groups and were also correlated (p = 0.0143). Future studies will be conducted with patients at different stages of treatment, associating the viral load with serum cytokines produced, thereby attempting to establish a prognostic indicator of the infection.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The recently released Affymetrix Human Gene 1.0 ST array has two major differences compared with standard 3' based arrays: (i) it interrogates the entire mRNA transcript, and (ii) it uses DNA targets. To assess the impact of these differences on array performance, we performed a series of comparative hybridizations between the Human Gene 1.0 ST and the Affymetrix HG-U133 Plus 2.0 and the Illumina HumanRef-8 BeadChip arrays. Additionally, both RNA and DNA targets were hybridized on HG-U133 Plus 2.0 arrays. The results show that the overall reproducibility of the Gene 1.0 ST array is best. When looking only at the high intensity probes, the reproducibility of the Gene 1.0 ST array and the Illumina BeadChip array is equally good. Concordance of array results was assessed using different inter-platform mappings. Agreements are best between the two labeling protocols using HG-U133 Plus 2.0 array. The Gene 1.0 ST array is most concordant with the HG-U133 array hybridized with cDNA targets. This may reflect the impact of the target type. Overall, the high degree of correspondence provides strong evidence for the reliability of the Gene 1.0 ST array.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose: To investigate the effect of incremental increases in intraocular straylight on threshold measurements made by three modern forms of perimetry: Standard Automated Perimetry (SAP) using Octopus (Dynamic, G-Pattern), Pulsar Perimetry (PP) (TOP, 66 points) and the Moorfields Motion Displacement Test (MDT) (WEBS, 32 points).Methods: Four healthy young observers were recruited (mean age 26yrs [25yrs, 28yrs]), refractive correction [+2 D, -4.25D]). Five white opacity filters (WOF), each scattering light by different amounts were used to create incremental increases in intraocular straylight (IS). Resultant IS values were measured with each WOF and at baseline (no WOF) for each subject using a C-Quant Straylight Meter (Oculus, Wetzlar, Germany). A 25 yr old has an IS value of ~0.85 log(s). An increase of 40% in IS to 1.2log(s) corresponds to the physiological value of a 70yr old. Each WOFs created an increase in IS between 10-150% from baseline, ranging from effects similar to normal aging to those found with considerable cataract. Each subject underwent 6 test sessions over a 2-week period; each session consisted of the 3 perimetric tests using one of the five WOFs and baseline (both instrument and filter were randomised).Results: The reduction in sensitivity from baseline was calculated. A two-way ANOVA on mean change in threshold (where subjects were treated as rows in the block and each increment in fog filters was treated as column) was used to examine the effect of incremental increases in straylight. Both SAP (p<0.001) and Pulsar (p<0.001) were significantly affected by increases in straylight. The MDT (p=0.35) remained comparatively robust to increases in straylight.Conclusions: The Moorfields MDT measurement of threshold is robust to effects of additional straylight as compared to SAP and PP.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Radiotherapy with concomitant and adjuvant TMZ is the standard of care for newly diagnosed GBM. MGMT methylation status may be an important determinant of treatment response. This trial, conducted by the RTOG, EORTC, and NCCTG, determined if intensified TMZ improves survival (OS) or progression free survival (PFS) in all patients or specific to MGMT status. Eligibility criteria included age . 18 yrs, KPS ≥ 60, and existence of a tissue block with . 1cm2 tumor for prospective MGMT and retrospective molecular analysis. Patients were randomized to Arm 1: standard TMZ (150-200 mg/m2 x 5 d) or Arm 2: dd TMZ (75-100 mg/m2 x 21 d) q 4 wks for 6-12 cycles. Symptom burden, quality of life (QOL), and neurocognition were prospectively and longitudinally assessed in a patient subset. 833 patients were randomized (1173 registered). Inadequate tissue (n ¼ 144) was the most frequent reason for nonrandomization.No statistical difference was observed between Arms 1 and 2 for median OS (16.6, 14.9 mo, p ¼ 0.63), median PFS (5.5, 6.7 mo, p ¼ 0.06), or methylation status. MGMT methylation was associated with improved OS (21.2, 14 mo, p , 0.0001), PFS (8.7, 5.7 mo, p , 0.0001), and treatment response (p ¼ 0.012). Cox modeling identifiedMGMT status and RPA class as significant predictors of OS; treatment arm and radiation technique (EORTC vs. RTOG) were not. There was increased grade ≥ 3 toxicity in Arm 2 (19%, 27%, p ¼ 0.008), which was mostly lymphopenia and fatigue. This study did not demonstrate improved efficacy for dd TMZ for newly diagnosed GBM regardless of methylation status. However, it confirmed the prognostic significance of MGMT methylation in GBM, demonstrated the feasibility of tumor tissue collection, molecular stratification, and collection of patient outcomes in a large transatlantic intergroup trial, thereby establishing a viable clinical trial paradigm. Support: NCI U10 CA 21661 and U10 CA37422.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objectifs: Comparer la qualité d'image entre des protocoles dose-standard avec rétroprojection filtrée et basse-dose avec reconstruction itérative en scanner du rachis cervical. Matériels et méthodes: 40 patients ont été investigués par scanner du rachis cervical et prospectivement randomisés en 2 groupes: dose-standard (120kV, 275mAs) avec rétroprojection filtrée, basse-dose (120kV, 150mAs) avec reconstruction itérative. Mesure du bruit, signal-sur-bruit et contraste-sur-bruit. Analyse semi-quantitative (4 points) par 2 observateurs indépendants des disques, foramens, cordon médullaire, ligaments, parties molles et vertèbres, en C3-C4 et C6-C7. Evaluation semi-quantitative (10 points) de la qualité d'image globale. Les paramètres de dose ont été mesurés. Résultats: Il n'y avait aucune différence significative de bruit, signal-sur-bruit ou contraste-sur-bruit entre les 2 protocoles (p≥0.39). En basse-dose avec reconstruction itérative, la visibilité était significativement meilleure pour les disques, foramens et ligaments (p≤0.05), égale pour le cordon médullaire et moins bonne pour les parties molles et vertèbres (p≤0.02). La qualité d'image globale était meilleure, avec une réduction de dose de 41%. Conclusion: Le scanner du rachis cervical basse-dose avec reconstruction itérative fournit des images égales ou meilleures pour les disques, foramens et ligaments, tout en réduisant la dose d'environ 40%.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The purpose of this study was to assess the knowledge and attitude of health care professionals regarding their use of universal precaution measures at a public emergency service. The study also aimed to assess the rates of occupational accidents involving biological substances among those workers. This study was performed with 238 workers, from June to November 2006, using univariate and multivariate analysis. The chance of not adopting precaution measures was 20.7 (95% CI: 5.68 - 75.14) times greater among drivers compared to physicians. No significant association was found between adopting universal precaution measures. The occupational accident rate was 20.6% (40.8% involving sharp-edged objects). The risk of physicians having an occupational accident was 2.7(95% CI: 1.05 - 7.09) times higher than that of drivers. The fact that a staff member had adequate knowledge about universal precaution measures was insufficient to foster compatible attitudes towards reducing the risk of transmitting infectious agents and causing occupational accidents.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Patterns of cigarette smoking in Switzerland were analyzed on the basis of sales data (available since 1924) and national health surveys conducted in the last decade. There was a steady and substantial increase in cigarettes sales up to the early 1970s. Thereafter, the curve tended to level off around an average value of 3,000 cigarettes per adult per year. According to the 1981-1983 National Health Survey, 37% of Swiss men were current smokers, 25% were ex-smokers, and 39% were never smokers. Corresponding porportions in women were 22, 11, and 67%. Among men, smoking prevalence was higher in lower social classes, and some moderate decline was apparent from survey data over the period 1975-1981 mostly in later middle-age. Trends in lung cancer death certification rates over the period 1950-1984 were analyzed using standard cross-sectional methods and a log-linear Poisson model to isolate the effects of age, birth cohort, and year of death. Mortality from lung cancer increased substantially among Swiss men between the early 1950s and the late 1970s, and levelled off (around a value of 70/100,000 men) thereafter. Among women, there has been a steady upward trend which started in the mid-1960s, and continues to climb steadily, although lung cancer mortality is still considerably lower in absolute terms (around 8/100,000 women) than in several North European countries or in North America. Cohort analyses indicate that the peak rates in men were reached by the generation born around 1910 and mortality stabilized for subsequent generations up to the 1930 birth cohort. Among females, marked increases were observed in each subsequent birth cohort. This pattern of trends is consistent with available information on smoking prevalence in successive generations, showing a peak among men for the 1910 cohort, but steady upward trends among females. Over the period 1980-1984, about 90% of lung cancer deaths among Swiss men and about 40% of those among women could be attributed to smoking (overall proportion, 85%).