958 resultados para sensible and latent heat fluxes


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Moisture equilibrium data of persimmon pulp powders with 50% maltodextrin (dry basis) obtained with different drying methods were determined at 20, 30, 40 and 50 degrees C. The spray-dryer gave a dry product with a higher adsorption capacity than the other methods. The vacuum- and freeze-dried products had the same adsorption capacity. The highest isosteric heat of sorption was observed for powders produced by spray-drying. The isokinetic temperature (T(B)) calculated for persimmon pulp powder obtained by vacuum-, spray- and freeze-drying were 541.4 K, 616.3 K, 513.2 K, respectively. The sorption process was spontaneous and enthalpy controlled.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The selection and use of hard chairside reline resins must be made with regard to dimensional stability, which will influence the accuracy of fit of the denture base. This study compared the dimensional change of two hard chairside reline resins (Duraliner II and Kooliner) and one heat-curing denture base resin (Lucitone 550). A stainless steel mold with reference dimensions (AB, CD) was used to obtain the samples. The materials were processed according to the manufacturer's recommendations. Measurements of the dimensions were made after processing and after the samples had been stored in distilled water at 37° C for eight different periods of time. The data were recorded and then analyzed with analysis of variance. All materials showed shrinkage immediately after processing (p < 0.05). The only resin that exhibited shrinkage after 60 days of storage in water was Duraliner II; these changes could be clinically significant in regard of tissue fit.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

STATEMENT OF PROBLEM: Because water sorption of autopolymerizing acrylic reline resins is accompanied by volumetric change, it is a physical property of importance. As residual monomer leaches into the oral fluids and causes tissue irritation, low solubility of these resins is desired. Another requirement is a satisfactory bond between the autopolymerizing acrylic resins and the denture base acrylic resin. PURPOSE: This study compared the water sorption, solubility, and the transverse bond strength of 2 autopolymerizing acrylic resins (Duraliner II and Kooliner) and 1 heat-polymerizing acrylic resin (Lucitone 550). MATERIAL AND METHODS: The water sorption and solubility test was performed as per International Standards Organization Specification No. 1567 for denture base polymers. Bond strengths between the autopolymerizing acrylic resins and the heat-polymerizing acrylic resin were determine with a 3-point loading test made on specimens immersed in distilled water at 37 degrees C for 50 hours and for 30 days. Visual inspection determined whether failures were adhesive or cohesive. RESULTS: Duraliner II acrylic resin showed significantly lower water sorption than Kooliner and Lucitone 550 acrylic resins. No difference was noted in the solubility of all materials. Kooliner acrylic resin demonstrated significantly lower transverse bond strength to denture base acrylic resin and failed adhesively. The failures seen with Duraliner II acrylic resin were primarily cohesive in nature. CONCLUSIONS: Autopolymerizing acrylic reline resins met water sorption and solubility requirements. However, Kooliner acrylic resin demonstrated significantly lower bond strength to denture base acrylic resin.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

An experiment was conducted to evaluate the impact in relation of dietary electrolytes, based on changes in the balance Na+K-Cl (DEB) and the ratio (K+Cl)/Na (DER) on the performance and survival of broilers subjected to acute heat stress. A total of 1575 male broiler chicks from 1 to 46 d of age were allocated in a 5x3 factorial arrangement in a completely randomized design, totaling of 15 treatments with 3 replicates of 35 birds each. The treatments consisted of 5 diets with electrolyte balances, arising from combinations DEB/DER (150/3, 250/2, 250/3, 250/4 and 350/3), associated with different times of application or not of the acute heat stress on birds at 25 and 36 d old. All diets were cornsoybean meal based and formulated to meet or exceed NRC requirements. Chicks had ad libitum access to feed and water in floor pens with wood shavings as litter. It was possible to verify that a DEB of 250 mEq/kg and a DER very close to the 3:1 providing a more nutritionally adequate diet. There was, however, the impossibility of obtaining a more suitable electrolyte ratio for a very low DEB (150 mEq/kg) or very high (350 mEq/kg) and also, to a very narrow DER (2:1) or very wide (4:1), due to an unfavorable performance and survival rate of birds in these conditions electrolytes adjustments of K, Na and Cl. There was clear indication, with significant difference (P < 0.05), that the DER has the potential to improve the performance of broilers, since simultaneous adjustment made in DEB, even in conditions of acute stress. The results of performance and survival rate of this study also indicate clearly that DER could not replace the DEB, and vice versa, in practical diets for broilers. Therefore, it can be affirmed that the strategic formulation of the correct electrolyte balance for DEB and DER enhances the performance and is able to prevent the effect of heat stress in broiler chickens, leading to better performance and survival.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This paper presents experimental results for flow boiling heat transfer coefficient and critical heat flux (CHF) in small flattened tubes. The tested flattened tubes have the same equivalent internal diameter of 2.2 mm, but different aspect height/width ratios (H/W) of 1/4, 1/2, 2 and 4. The experimental data were compared against results for circular tubes using R134a and R245fa as working fluids at a nominal saturation temperature of 31 degrees C. For mass velocities higher than 200 kg/m(2)s, the flattened and circular tubes presented similar heat transfer coefficients. Such a behavior is related to the fact that stratification effects are negligible under conditions of higher mass velocities. Heat transfer correlations from the literature, usually developed using only circular-channel experimental data, predicted the flattened tube results for mass velocities higher than 200 kg/m(2)s with mean absolute error lower than 20% using the equivalent diameter to account for the geometry effect. Similarly, the critical heat flux results were found to be independent of the tube aspect ratio when the same equivalent length was kept. Equivalent length is a new parameter which takes into account the channel heat transfer area. The CHF correlations for round tubes predicted the flattened tube data relatively well when using the equivalent diameter and length. Furthermore, a new proposed CHF correlation predicted the present flattened tube data with a mean absolute error of 5%. (C) 2012 Elsevier Ltd. All rights reserved.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

OBJECTIVE: To estimate the prevalences of tuberculosis and latent tuberculosis ill inmates. METHODS: Observational study was carried out with inmates of a prison and a jail in the State of Sao Paulo, Southeastern Brazil, between March and December of 2008. Questionnaires were used to collect sociodemographic and epidemiological data. Tuberculin skin testing was administered (PPD-RT23-2TU/0.1 mL), and the following laboratory tests were also performed: sputum smear examination, sputum culture, identification of strains isolated and drug susceptibility testing. The variables were compared using Pearson's chi-square (chi(2)) association test, Fisher's exact test and the proportion test. RESULTS: Of the 2,435 inmates interviewed, 2,237(91.9%) agreed to submit to tuberculin skin testing and of these, 73.0% had positive reactions. The prevalence of tuberculosis was 830.6 per 100,000 inmates. The coefficients of prevalence were 1,029.5/100,000 for inmates of the prison and 525.7/100,000 for inmates of the jail. The sociodemographic characteristics of the inmates in the two groups studied were similar; most of the inmates were young and single with little schooling. The epidemiological characteristics differed between the prison units, with the number of cases of previous tuberculosis and of previous contact with the disease greater in the prison and coughing, expectoration and smoking more common in the jail. Among the 20 Mycobacterium tuberculosis strains identified, 95.0% were sensitive to anti-tuberculosis drugs, and 5.0% were resistant to streptomycin. CONCLUSIONS: The prevalences of tuberculosis and latent tuberculosis were higher in the incarcerated population than in the general population, and they were also higher in the prison than in the jail.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This work focuses on magnetohydrodynamic (MHD) mixed convection flow of electrically conducting fluids enclosed in simple 1D and 2D geometries in steady periodic regime. In particular, in Chapter one a short overview is given about the history of MHD, with reference to papers available in literature, and a listing of some of its most common technological applications, whereas Chapter two deals with the analytical formulation of the MHD problem, starting from the fluid dynamic and energy equations and adding the effects of an external imposed magnetic field using the Ohm's law and the definition of the Lorentz force. Moreover a description of the various kinds of boundary conditions is given, with particular emphasis given to their practical realization. Chapter three, four and five describe the solution procedure of mixed convective flows with MHD effects. In all cases a uniform parallel magnetic field is supposed to be present in the whole fluid domain transverse with respect to the velocity field. The steady-periodic regime will be analyzed, where the periodicity is induced by wall temperature boundary conditions, which vary in time with a sinusoidal law. Local balance equations of momentum, energy and charge will be solved analytically and numerically using as parameters either geometrical ratios or material properties. In particular, in Chapter three the solution method for the mixed convective flow in a 1D vertical parallel channel with MHD effects is illustrated. The influence of a transverse magnetic field will be studied in the steady periodic regime induced by an oscillating wall temperature. Analytical and numerical solutions will be provided in terms of velocity and temperature profiles, wall friction factors and average heat fluxes for several values of the governing parameters. In Chapter four the 2D problem of the mixed convective flow in a vertical round pipe with MHD effects is analyzed. Again, a transverse magnetic field influences the steady periodic regime induced by the oscillating wall temperature of the wall. A numerical solution is presented, obtained using a finite element approach, and as a result velocity and temperature profiles, wall friction factors and average heat fluxes are derived for several values of the Hartmann and Prandtl numbers. In Chapter five the 2D problem of the mixed convective flow in a vertical rectangular duct with MHD effects is discussed. As seen in the previous chapters, a transverse magnetic field influences the steady periodic regime induced by the oscillating wall temperature of the four walls. The numerical solution obtained using a finite element approach is presented, and a collection of results, including velocity and temperature profiles, wall friction factors and average heat fluxes, is provided for several values of, among other parameters, the duct aspect ratio. A comparison with analytical solutions is also provided, as a proof of the validity of the numerical method. Chapter six is the concluding chapter, where some reflections on the MHD effects on mixed convection flow will be made, in agreement with the experience and the results gathered in the analyses presented in the previous chapters. In the appendices special auxiliary functions and FORTRAN program listings are reported, to support the formulations used in the solution chapters.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

La tesi presenta il criterio di regolarità di Wiener dell’ambito classico dell’operatore di Laplace ed in seguito alcune nozioni di teoria del potenziale e la dimostrazione del criterio nel caso dell’operatore del calore; in questa seconda sezione viene dedicata particolare attenzione alle formule di media e ad una diseguaglianza forte di Harnack, che risultano fondamentali nella trattazione dell’argomento centrale.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The last decade has witnessed very fast development in microfabrication technologies. The increasing industrial applications of microfluidic systems call for more intensive and systematic knowledge on this newly emerging field. Especially for gaseous flow and heat transfer at microscale, the applicability of conventional theories developed at macro scale is not yet completely validated; this is mainly due to scarce experimental data available in literature for gas flows. The objective of this thesis is to investigate these unclear elements by analyzing forced convection for gaseous flows through microtubes and micro heat exchangers. Experimental tests have been performed with microtubes having various inner diameters, namely 750 m, 510 m and 170 m, over a wide range of Reynolds number covering the laminar region, the transitional zone and also the onset region of the turbulent regime. The results show that conventional theory is able to predict the flow friction factor when flow compressibility does not appear and the effect of fluid temperature-dependent properties is insignificant. A double-layered microchannel heat exchanger has been designed in order to study experimentally the efficiency of a gas-to-gas micro heat exchanger. This microdevice contains 133 parallel microchannels machined into polished PEEK plates for both the hot side and the cold side. The microchannels are 200 µm high, 200 µm wide and 39.8 mm long. The design of the micro device has been made in order to be able to test different materials as partition foil with flexible thickness. Experimental tests have been carried out for five different partition foils, with various mass flow rates and flow configurations. The experimental results indicate that the thermal performance of the countercurrent and cross flow micro heat exchanger can be strongly influenced by axial conduction in the partition foil separating the hot gas flow and cold gas flow.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This thesis focuses on the role of B cells in mCMV and Leishmania major infection. B cells are an essential component of the adaptive immune system and play a key role in the humoral immune response. In mCMV infection we analyzed the influence of B cells on the virus-specific CD8 T cell response, in detail the role of B cells as IL-10 secreting cells, as source of immunoglobulin (Ig) and as antigen presenting cells. In Leishmania major infection we investigated the role of Ig in Th1 and Th2 directed disease.rnWe found in mCMV infection that the B cell secreted IL-10 suppresses effectively the acute virus-specific CD8 T cell response, while the IL-10 secreted by dendritic cell has no obvious effect. Ig has no effect in the acute virus-specific CD8 T cell response, but in memory response Ig is essential. If Ig is missing the CD8 T cell population remains high in memory response 135 days post infection. The complete absence of B cells dramatically reduces the acute virus-specific CD8 T cell response, while B cell reconstitution just partially rescues this dramatic reduction. A comparison of this reduction in a B cell free organism to an organism with depleted dendritic cells gave a similar result. To exclude a malfunction of the CD8 T cells in the B cell deficient mice, the decreased virus-specific CD8 T cell population was confirmed in a B cell depletion model. Further, bone marrow chimeras with a B cell compartment deficient for CD40-/- showed a decrease of the virus-specific response and an involvement of CD40 on B cells. Taken together these results suggest a role for B cells in antigen presentation during mCMV infection.rnFurther we took advantage of the altered mCMV specific CD8 T cell memory response in mice without Ig to investigate the memory inflation of CD8 T cells specific for distinct mCMV specifc peptides. Using a SIINFEKL-presenting virus system, we were able to shorten the time until the memory inflation occurs and show that direct presentation stimulates the memory inflation. rnIn Leishmania major infection, Ig of Th2 balanced BALB/c mice has a central role in preventing a systemic infection, although the ear lesions are smaller in IgMi mice without specific Ig. Here the parasite loads of ears and spleen are elevated, and an IMS-reconstitution does not affect the parasite load. In contrast in Th1 balanced C57BL/6 mice, reconstitution of IgMi mice with serum of either untreated or immunized mice decreased the parasite load of spleen and ear, further IMS treatment reduces the size of the spleen and the cytokine-levels of IL-10, IL-4, IL-2 and IFN-γ to a level comparable to wt mice. rn

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Global climate change is impacting coral reefs worldwide, with approximately 19% of reefs being permanently degraded, 15% showing symptoms of imminent collapse, and 20% at risk of becoming critically affected in the next few decades. This alarming level of reef degradation is mainly due to an increase in frequency and intensity of natural and anthropogenic disturbances. Recent evidence has called into question whether corals have the capacity to acclimatize or adapt to climate changes and some groups of corals showed inherent physiological tolerance to environmental stressors. The aim of the present study was to evaluate mRNA expression patterns underlying differences in thermal tolerance in specimen of the common reef-building coral Pocillopora verrucosa collected at different locations in Bangka Island waters (North Sulawesi, Indonesia). Part of the experimental work was carried out at the CoralEye Reef Research Outpost (Bangka Island). This includes sampling of corals at selected sites and at different depths (3 and 12 m) as well as their experimental exposure to an increased water temperature under controlled conditions for 3 and 7 days. Levels of mRNAs encoding ATP synthase (ATPs) NADH dehydrogenase (NDH) and a 70kDa Heat Shock Protein (HSP70) were evaluated by quantitative real time PCR. Transcriptional profiles evaluated under field conditions suggested an adaptation to peculiar local environmental conditions in corals collected at different sites and at the low depth. Nevertheless, high–depth collected corals showed a less pronounced site-to-site separation suggesting more homogenous environmental conditions. Exposure to an elevated temperature under controlled conditions pointed out that corals adapted to the high depth are more sensitive to the effects of thermal stress, so that reacted to thermal challenge by significantly over-expressing the selected gene products. Being continuously exposed to fluctuating environmental conditions, low-depth adapted corals are more resilient to the stress stimulus, and indeed showed unaffected or down-regulated mRNA expression profiles. Overall these results highlight that transcriptional profiles of selected genes involved in cellular stress response are modulated by natural seasonal temperature changes in P. verrucosa. Moreover, specimens living in more variable habitats (low-depth) exhibit higher basal HSP70 mRNA levels, possibly enhancing physiological tolerance to environmental stressors.