960 resultados para radiological contrast
Resumo:
Allergy to radiographic contrast media Hypersensitivity reactions to radio-contrast media are common in the daily practice. These products are responsible for immediate (< or = 1 hour after administration) and non immediate (> 1 hour after administration) hypersensitivity reactions. A diagnostic work-up by an allergologist with skin tests and in some cases provocation tests is of value in reducing the risk of recurrent hypersensitivity reactions to iodinated contrast media. A careful selection of the patients is required because the incidence of breakthrough reactions is still concerning, even with proper premedication. Practical recommendations are presented in this article. For gadolinium-based contrast agents, data in the literature is not sufficient for suggesting guidelines.
Resumo:
PURPOSE: As the magnetic susceptibility induced frequency shift increases linearly with magnetic field strength, the present work evaluates manganese as a phase imaging contrast agent and investigates the dose dependence of brain enhancement in comparison to T1 -weighted imaging after intravenous administration of MnCl2 . METHODS: Experiments were carried out on 12 Sprague-Dawley rats. MnCl2 was infused intravenously with the following doses: 25, 75, 125 mg/kg (n=4). Phase, T1 -weighted images and T1 maps were acquired before and 24h post MnCl2 administration at 14.1 Tesla. RESULTS: Manganese enhancement was manifested in phase imaging by an increase in frequency shift differences between regions rich in calcium gated channels and other tissues, together with local increase in signal to noise ratio (from the T1 reduction). Such contrast improvement allowed a better visualization of brain cytoarchitecture. The measured T1 decrease observed across different manganese doses and in different brain regions were consistent with the increase in the contrast to noise ratio (CNR) measured by both T1 -weighted and phase imaging, with the strongest variations being observed in the dentate gyrus and olfactory bulb. CONCLUSION: Overall from its high sensitivity to manganese combined with excellent CNR, phase imaging is a promising alternative imaging protocol to assess manganese enhanced MRI at ultra high field. Magn Reson Med 72:1246-1256, 2014. © 2013 Wiley Periodicals, Inc.
Resumo:
The paper contrasts empirically the results of alternative methods for estimating thevalue and the depreciation of mineral resources. The historical data of Mexico andVenezuela, covering the period 1920s-1980s, is used to contrast the results of severalmethods. These are the present value, the net price method, the user cost method andthe imputed income method. The paper establishes that the net price and the user costare not competing methods as such, but alternative adjustments to different scenariosof closed and open economies. The results prove that the biases of the methods, ascommonly described in the theoretical literature, only hold under the most restrictedscenario of constant rents over time. It is argued that the difference between what isexpected to happen and what actually did happen is for the most part due to a missingvariable, namely technological change. This is an important caveat to therecommendations made based on these models.
Resumo:
OBJECTIVE: To examine the relationship of early serum procalcitonin (PCT) levels with the severity of post-cardiac arrest syndrome (PCAS), long-term neurological recovery and the risk of early-onset infections in patients with coma after cardiac arrest (CA) treated with therapeutic hypothermia (TH). METHODS: A prospective cohort of adult comatose CA patients treated with TH (33°C, for 24h) admitted to the medical/surgical intensive care unit, Lausanne University Hospital, was studied. Serum PCT was measured early after CA, at two time-points (days 1 and 2). The SOFA score was used to quantify the severity of PCAS. Diagnosis of early-onset infections (within the first 7 days of ICU stay) was made after review of clinical, radiological and microbiological data. Neurological recovery at 3 months was assessed with Cerebral Performance Categories (CPC), and was dichotomized as favorable (CPC 1-2) vs. unfavorable (CPC 3-5). RESULTS: From December 2009 to April 2012, 100 patients (median age 64 [interquartile range 55-73] years, median time from collapse to ROSC 20 [11-30]min) were studied. Peak PCT correlated with SOFA score at day 1 (Spearman's R=0.44, p<0.0001) and was associated with neurological recovery at 3 months (peak PCT 1.08 [0.35-4.45]ng/ml in patients with CPC 1-2 vs. 3.07 [0.89-9.99] ng/ml in those with CPC 3-5, p=0.01). Peak PCT did not differ significantly between patients with early-onset vs. no infections (2.14 [0.49-6.74] vs. 1.53 [0.46-5.38]ng/ml, p=0.49). CONCLUSIONS: Early elevations of serum PCT levels correlate with the severity of PCAS and are associated with worse neurological recovery after CA and TH. In contrast, elevated serum PCT did not correlate with early-onset infections in this setting.
Resumo:
Purpose: To evaluate whether parametric imaging with contrast material-enhanced ultrasonography (US) is superior to visual assessment for the differential diagnosis of focal liver lesions (FLLs). Materials and Methods: This study had institutional review board approval, and verbal patient informed consent was obtained. Between August 2005 and October 2008, 146 FLLs in 145 patients (63 women, 82 men; mean age, 62.5 years; age range, 22-89 years) were imaged with real-time low-mechanical-index contrast-enhanced US after a bolus injection of 2.4 mL of a second-generation contrast agent. Clips showing contrast agent uptake kinetics (including arterial, portal, and late phases) were recorded and subsequently analyzed off-line with dedicated image processing software. Analysis of the dynamic vascular patterns (DVPs) of lesions with respect to adjacent parenchyma allowed mapping DVP signatures on a single parametric image. Cine loops of contrast-enhanced US and results from parametric imaging of DVP were assessed separately by three independent off-site readers who classified each lesion as benign, malignant, or indeterminate. Sensitivity, specificity, accuracy, and positive and negative predictive values were calculated for both techniques. Interobserver agreement (κ statistics) was determined. Results: Sensitivities for visual interpretation of cine loops for the three readers were 85.0%, 77.9%, and 87.6%, which improved significantly to 96.5%, 97.3%, and 96.5% for parametric imaging, respectively (P < .05, McNemar test), while retaining high specificity (90.9% for all three readers). Accuracy scores of parametric imaging were higher than those of conventional contrast-enhanced US for all three readers (P < .001, McNemar test). Interobserver agreement increased with DVP parametric imaging compared with conventional contrast-enhanced US (change of κ from 0.54 to 0.99). Conclusion: Parametric imaging of DVP improves diagnostic performance of contrast-enhanced US in the differentiation between malignant and benign FLLs; it also provides excellent interobserver agreement.
Resumo:
Lithium is widely used in psychotherapy. The (6)Li isotope has a long intrinsic longitudinal relaxation time T(1) on the order of minutes, making it an ideal candidate for hyperpolarization experiments. In the present study we demonstrated that lithium-6 can be readily hyperpolarized within 30 min, while retaining a long polarization decay time on the order of a minute. We used the intrinsically long relaxation time for the detection of 500 nM contrast agent in vitro. Hyperpolarized lithium-6 was administered to the rat and its signal retained a decay time on the order of 70 sec in vivo. Localization experiments imply that the lithium signal originated from within the brain and that it was detectable up to 5 min after administration. We conclude that the detection of submicromolar contrast agents using hyperpolarized NMR nuclei such as (6)Li may provide a novel avenue for molecular imaging.
Resumo:
The differentiation between benign and malignant focal liver lesions plays an important role in diagnosis of liver disease and therapeutic planning of local or general disease. This differentiation, based on characterization, relies on the observation of the dynamic vascular patterns (DVP) of lesions with respect to adjacent parenchyma, and may be assessed during contrast-enhanced ultrasound imaging after a bolus injection. For instance, hemangiomas (i.e., benign lesions) exhibit hyper-enhanced signatures over time, whereas metastases (i.e., malignant lesions) frequently present hyperenhanced foci during the arterial phase and always become hypo-enhanced afterwards. The objective of this work was to develop a new parametric imaging technique, aimed at mapping the DVP signatures into a single image called a DVP parametric image, conceived as a diagnostic aid tool for characterizing lesion types. The methodology consisted in processing a time sequence of images (DICOM video data) using four consecutive steps: (1) pre-processing combining image motion correction and linearization to derive an echo-power signal, in each pixel, proportional to local contrast agent concentration over time; (2) signal modeling, by means of a curve-fitting optimization, to compute a difference signal in each pixel, as the subtraction of adjacent parenchyma kinetic from the echopower signal; (3) classification of difference signals; and (4) parametric image rendering to represent classified pixels as a support for diagnosis. DVP parametric imaging was the object of a clinical assessment on a total of 146 lesions, imaged using different medical ultrasound systems. The resulting sensitivity and specificity were 97% and 91%, respectively, which compare favorably with scores of 81 to 95% and 80 to 95% reported in medical literature for sensitivity and specificity, respectively.
Resumo:
The objective of this paper is to compare the performance of twopredictive radiological models, logistic regression (LR) and neural network (NN), with five different resampling methods. One hundred and sixty-seven patients with proven calvarial lesions as the only known disease were enrolled. Clinical and CT data were used for LR and NN models. Both models were developed with cross validation, leave-one-out and three different bootstrap algorithms. The final results of each model were compared with error rate and the area under receiver operating characteristic curves (Az). The neural network obtained statistically higher Az than LR with cross validation. The remaining resampling validation methods did not reveal statistically significant differences between LR and NN rules. The neural network classifier performs better than the one based on logistic regression. This advantage is well detected by three-fold cross-validation, but remains unnoticed when leave-one-out or bootstrap algorithms are used.
Resumo:
OBJECTIVE. The purpose of this study was to improve the blood-pool signal-to-noise ratio (SNR) and blood-myocardium contrast-to-noise ratio (CNR) of slow-infusion 3-T whole-heart coronary MR angiography (MRA).SUBJECTS AND METHODS. In 2D sensitivity encoding (SENSE), the number of acquired k-space lines is reduced, allowing less radiofrequency excitation per cardiac cycle and a longer TR. The former can be exploited for signal enhancement with a higher radiofrequency excitation angle, and the latter leads to noise reduction due to lower data-sampling bandwidth. Both effects contribute to SNR gain in coronary MRA when spatial and temporal resolution and acquisition time remain identical. Numeric simulation was performed to select the optimal 2D SENSE pulse sequence parameters and predict the SNR gain. Eleven patients underwent conventional unenhanced and the proposed 2D SENSE contrast-enhanced coronary MRA acquisition. Blood-pool SNR, blood-myocardium CNR, visible vessel length, vessel sharpness, and number of side branches were evaluated.RESULTS. Consistent with the numeric simulation, using 2D SENSE in contrast-enhanced coronary MRA resulted in significant improvement in aortic blood-pool SNR (unenhanced vs contrast-enhanced, 37.5 +/- 14.7 vs 121.3 +/- 44.0; p < 0.05) and CNR (14.4 +/- 6.9 vs 101.5 +/- 40.8; p < 0.05) in the patient sample. A longer length of left anterior descending coronary artery was visualized, but vessel sharpness, coronary artery coverage, and image quality score were not improved with the proposed approach.CONCLUSION. In combination with contrast administration, 2D SENSE was found effective in improving SNR and CNR in 3-T whole-heart coronary MRA. Further investigation of cardiac motion compensation is necessary to exploit the SNR and CNR advantages and to achieve submillimeter spatial resolution.
Resumo:
PURPOSE: To investigate the utility of inversion recovery with ON-resonant water suppression (IRON) to create positive signal in normal lymph nodes after injection of superparamagnetic nanoparticles. MATERIALS AND METHODS: Experiments were conducted on six rabbits, which received a single bolus injection of 80 mumol Fe/kg monocrystalline iron oxide nanoparticle (MION-47). Magnetic resonance imaging (MRI) was performed at baseline, 1 day, and 3 days after MION-47 injection using conventional T(1)- and T(2)*-weighted sequences and IRON. Contrast-to-noise ratios (CNR) were measured in blood and in paraaortic lymph nodes. RESULTS: On T(2)*-weighted images, as expected, signal attenuation was observed in areas of paraaortic lymph nodes after MION-47 injection. However, using IRON the paraaortic lymph nodes exhibited very high contrast enhancement, which remained 3 days after injection. CNR with IRON was 2.2 +/- 0.8 at baseline, increased markedly 1 day after injection (23.5 +/- 5.4, P < 0.01 vs. baseline), and remained high after 3 days (21.8 +/- 5.7, *P < 0.01 vs. baseline). CNR was also high in blood 1 day after injection (42.7 +/- 7.2 vs. 1.8 +/- 0.7 at baseline, P < 0.01) but approached baseline after 3 days (1.9 +/- 1.4, P = NS vs. baseline). CONCLUSION: IRON in conjunction with superparamagnetic nanoparticles can be used to perform 'positive contrast' MR-lymphography, particularly 3 days after injection of the contrast agent, when signal is no longer visible within blood vessels. The proposed method may have potential as an adjunct for nodal staging in cancer screening.
Resumo:
PURPOSE: To investigate the ability of inversion recovery ON-resonant water suppression (IRON) in conjunction with P904 (superparamagnetic nanoparticles which consisting of a maghemite core coated with a low-molecular-weight amino-alcohol derivative of glucose) to perform steady-state equilibrium phase MR angiography (MRA) over a wide dose range. MATERIALS AND METHODS: Experiments were approved by the institutional animal care committee. Rabbits (n = 12) were imaged at baseline and serially after the administration of 10 incremental dosages of 0.57-5.7 mgFe/Kg P904. Conventional T1-weighted and IRON MRA were obtained on a clinical 1.5 Tesla (T) scanner to image the thoracic and abdominal aorta, and peripheral vessels. Contrast-to-noise ratios (CNR) and vessel sharpness were quantified. RESULTS: Using IRON MRA, CNR and vessel sharpness progressively increased with incremental dosages of the contrast agent P904, exhibiting constantly higher contrast values than T1 -weighted MRA over a very wide range of contrast agent doses (CNR of 18.8 ± 5.6 for IRON versus 11.1 ± 2.8 for T1 -weighted MRA at 1.71 mgFe/kg, P = 0.02 and 19.8 ± 5.9 for IRON versus -0.8 ± 1.4 for T1-weighted MRA at 3.99 mgFe/kg, P = 0.0002). Similar results were obtained for vessel sharpness in peripheral vessels, (Vessel sharpness of 46.76 ± 6.48% for IRON versus 33.20 ± 3.53% for T1-weighted MRA at 1.71 mgFe/Kg, P = 0.002, and of 48.66 ± 5.50% for IRON versus 19.00 ± 7.41% for T1-weighted MRA at 3.99 mgFe/Kg, P = 0.003). CONCLUSION: Our study suggests that quantitative CNR and vessel sharpness after the injection of P904 are consistently higher for IRON MRA when compared with conventional T1-weighted MRA. These findings apply for a wide range of contrast agent dosages.
Resumo:
Normal ageing is associated with characteristic changes in brain microstructure. Although in vivo neuroimaging captures spatial and temporal patterns of age-related changes of anatomy at the macroscopic scale, our knowledge of the underlying (patho)physiological processes at cellular and molecular levels is still limited. The aim of this study is to explore brain tissue properties in normal ageing using quantitative magnetic resonance imaging (MRI) alongside conventional morphological assessment. Using a whole-brain approach in a cohort of 26 adults, aged 18-85years, we performed voxel-based morphometric (VBM) analysis and voxel-based quantification (VBQ) of diffusion tensor, magnetization transfer (MT), R1, and R2* relaxation parameters. We found age-related reductions in cortical and subcortical grey matter volume paralleled by changes in fractional anisotropy (FA), mean diffusivity (MD), MT and R2*. The latter were regionally specific depending on their differential sensitivity to microscopic tissue properties. VBQ of white matter revealed distinct anatomical patterns of age-related change in microstructure. Widespread and profound reduction in MT contrasted with local FA decreases paralleled by MD increases. R1 reductions and R2* increases were observed to a smaller extent in overlapping occipito-parietal white matter regions. We interpret our findings, based on current biophysical models, as a fingerprint of age-dependent brain atrophy and underlying microstructural changes in myelin, iron deposits and water. The VBQ approach we present allows for systematic unbiased exploration of the interaction between imaging parameters and extends current methods for detection of neurodegenerative processes in the brain. The demonstrated parameter-specific distribution patterns offer insights into age-related brain structure changes in vivo and provide essential baseline data for studying disease against a background of healthy ageing.
Resumo:
OBJECTIVE: The objective of our study was to establish a standardized procedure for postmortem whole-body CT-based angiography with lipophilic and hydrophilic contrast media solutions and to compare the results of these two methods. MATERIALS AND METHODS: Minimally invasive postmortem CT angiography was performed on 10 human cadavers via access to the femoral blood vessels. Separate perfusion of the arterial and venous systems was established with a modified heart-lung machine using a mixture of an oily contrast medium and paraffin (five cases) and a mixture of a water-soluble contrast medium with polyethylene glycol (PEG) 200 in the other five cases. Imaging was executed with an MDCT scanner. RESULTS: The minimally invasive femoral approach to the vascular system provided a good depiction of lesions of the complete vascular system down to the level of the small supplying vessels. Because of the enhancement of well-vascularized tissues, angiography with the PEG-mixed contrast medium allowed the detection of tissue lesions and the depiction of vascular abnormalities such as pulmonary embolisms or ruptures of the vessel wall. CONCLUSION: The angiographic method with a water-soluble contrast medium and PEG as a contrast-agent dissolver showed a clearly superior quality due to the lack of extravasation through the gastrointestinal vascular bed and the enhancement of soft tissues (cerebral cortex, myocardium, and parenchymal abdominal organs). The diagnostic possibilities of these findings in cases of antemortem ischemia of these tissues are not yet fully understood.