899 resultados para portable instruments


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Capillary-based systems for measuring the input impedance of musical wind instruments were first developed in the mid-20th century and remain in widespread use today. In this paper, the basic principles and assumptions underpinning the design of such systems are examined. Inexpensive modifications to a capillary-based impedance measurement set-up made possible due to advances in computing and data acquisition technology are discussed. The modified set-up is able to measure both impedance magnitude and impedance phase even though it only contains one microphone. In addition, a method of calibration is described that results in a significant improvement in accuracy when measuring high impedance objects on the modified capillary-based system. The method involves carrying out calibration measurements on two different objects whose impedances are well-known theoretically. The benefits of performing two calibration measurements (as opposed to the one calibration measurement that has been traditionally used) are demonstrated experimentally through input impedance measurements on two test objects and a Boosey and Hawkes oboe. © S. Hirzel Verlag · EAA.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Data obtained with any research tool must be reproducible, a concept referred to as reliability. Three techniques are often used to evaluate reliability of tools using continuous data in aging research: intraclass correlation coefficients (ICC), Pearson correlations, and paired t tests. These are often construed as equivalent when applied to reliability. This is not correct, and may lead researchers to select instruments based on statistics that may not reflect actual reliability. The purpose of this paper is to compare the reliability estimates produced by these three techniques and determine the preferable technique. A hypothetical dataset was produced to evaluate the reliability estimates obtained with ICC, Pearson correlations, and paired t tests in three different situations. For each situation two sets of 20 observations were created to simulate an intrarater or inter-rater paradigm, based on 20 participants with two observations per participant. Situations were designed to demonstrate good agreement, systematic bias, or substantial random measurement error. In the situation demonstrating good agreement, all three techniques supported the conclusion that the data were reliable. In the situation demonstrating systematic bias, the ICC and t test suggested the data were not reliable, whereas the Pearson correlation suggested high reliability despite the systematic discrepancy. In the situation representing substantial random measurement error where low reliability was expected, the ICC and Pearson coefficient accurately illustrated this. The t test suggested the data were reliable. The ICC is the preferred technique to measure reliability. Although there are some limitations associated with the use of this technique, they can be overcome.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The study details the development of a fully validated, rapid and portable sensor based method for the on-site analysis of microcystins in freshwater samples. The process employs a novel lysis method for the mechanical lysis of cyanobacterial cells, with glass beads and a handheld frother in only 10min. The assay utilises an innovative planar waveguide device that, via an evanescent wave excites fluorescent probes, for amplification of signal in a competitive immunoassay, using an anti-microcystin monoclonal with cross-reactivity against the most common, and toxic variants. Validation of the assay showed the limit of detection (LOD) to be 0.78ngmL and the CCß to be 1ngmL. Robustness of the assay was demonstrated by intra- and inter-assay testing. Intra-assay analysis had % C.V.s between 8 and 26% and recoveries between 73 and 101%, with inter-assay analysis demonstrating % C.V.s between 5 and 14% and recoveries between 78 and 91%. Comparison with LC-MS/MS showed a high correlation (R=0.9954) between the calculated concentrations of 5 different Microcystis aeruginosa cultures for total microcystin content. Total microcystin content was ascertained by the individual measurement of free and cell-bound microcystins. Free microcystins can be measured to 1ngmL, and with a 10-fold concentration step in the intracellular microcystin protocol (which brings the sample within the range of the calibration curve), intracellular pools may be determined to 0.1ngmL. This allows the determination of microcystins at and below the World Health Organisation (WHO) guideline value of 1µgL. This sensor represents a major advancement in portable analysis capabilities and has the potential for numerous other applications.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Researchers and clinicians have experienced substantial difficulties locating measures that are suitable for use within palliative care settings. This article details the psychometric properties of nine instruments designed to assess the following psychosocial characteristics of family caregivers: competence, mastery, self-efficacy, burden, optimism, preparedness, social support, rewards, and mutuality. Results are based on the responses of 106 primary family caregivers caring for relatives dying of cancer. Principal components extraction with varimax rotation was used to explore the underlying structure of each measure. Following the exclusion of complex variables, suggested components for most measures comprised relatively homogenous items, which were good to excellent measures of each component. Some components comprised only two items; however, Cronbach's alphas typically indicated moderate to high levels of internal consistency. Overall, the results of this study suggest that most of the measures analyzed, excepting the mastery and mutuality scales, can be recommended to examine the family caregiver experience and test supportive interventions.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE: To identify vision Patient-Reported Outcomes instruments relevant to glaucoma and assess their content validity.

METHODS: MEDLINE, MEDLINE in Process, EMBASE and SCOPUS (to January 2009) were systematically searched. Observational studies or randomised controlled trials, published in English, reporting use of vision instruments in glaucoma studies involving adults were included. In addition, reference lists were scanned to identify additional studies describing development and/or validation to ascertain the final version of the instruments. Instruments' content was then mapped onto a theoretical framework, the World Health Organization International Classification of Functioning, Disability and Health. Two reviewers independently evaluated studies for inclusion and quality assessed instrument content.

RESULTS: Thirty-three instruments were identified. Instruments were categorised into thirteen vision status, two vision disability, one vision satisfaction, five glaucoma status, one glaucoma medication related to health status, five glaucoma medication side effects and six glaucoma medication satisfaction measures according to each instruments' content. The National Eye Institute Visual Function Questionnaire-25, Impact of Vision Impairment and Treatment Satisfaction Survey-Intraocular Pressure had the highest number of positive ratings in the content validity assessment.

CONCLUSION: This study provides a descriptive catalogue of vision-specific PRO instruments, to inform the choice of an appropriate measure of patient-reported outcomes in a glaucoma context.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper introduces a series of new musical instruments that have been designed to
address questions relating to performative virtuosity in the area of ensemble-based
improvisation. The intentionally exploited inconsistent nature of these instruments
raises questions around traditional notions of instrument mastery and opens up
possible methods of recon?guring the performer-instrument relationship.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The technique of diffusive gradients in thin films (DGT) is often employed to quantify labile metals in situ; however, it is a challenge to perform the measurements in-field. This study evaluated the capability of field-portable X-ray fluorescence (FP-XRF) to swiftly generate elemental speciation information with DGT. Biologically available metal ions in environmental samples passively preconcentrate in the thin films of DGT devices, providing an ideal and uniform matrix for XRF nondestructive detection. Strong correlation coefficients (r > 0.992 for Mn, Cu, Zn, Pb and As) were obtained for all elements during calibration. The limits of quantitation (LOQ) for the investigated elements of FP-XRF on DGT devices are 2.74 for Mn, 4.89 for Cu, 2.89 for Zn, 2.55 for Pb, and 0.48 for As (unit: µg cm(-2)). When Pb and As co-existed in the solution trials, As did not interfere with Pb detection when using Chelex-DGT. However, there was a significant enhancement of the Pb reading attributed to As when ferrihydrite binding gels were tested, consistent with Fe-oxyhydroxide surfaces absorbing large quantities of As. This study demonstrates the value of the FP-XRF technique to rapidly and nondestructively detect the metals accumulated in DGT devices, providing a new and simple diagnostic tool for on-site environmental monitoring of labile metals/metalloids

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this article the multibody simulation software package MADYMO for analysing and optimizing occupant safety design was used to model crash tests for Normal Containment barriers in accordance with EN 1317. The verification process was carried out by simulating a TB31 and a TB32 crash test performed on vertical portable concrete barriers and by comparing the numerical results to those obtained experimentally. The same modelling approach was applied to both tests to evaluate the predictive capacity of the modelling at two different impact speeds. A sensitivity analysis of the vehicle stiffness was also carried out. The capacity to predict all of the principal EN1317 criteria was assessed for the first time: the acceleration severity index, the theoretical head impact velocity, the barrier working width and the vehicle exit box. Results showed a maximum error of 6% for the acceleration severity index and 21% for theoretical head impact velocity for the numerical simulation in comparison to the recorded data. The exit box position was predicted with a maximum error of 4°. For the working width, a large percentage difference was observed for test TB31 due to the small absolute value of the barrier deflection but the results were well within the limit value from the standard for both tests. The sensitivity analysis showed the robustness of the modelling with respect to contact stiffness increase of ±20% and ±40%. This is the first multibody model of portable concrete barriers that can reproduce not only the acceleration severity index but all the test criteria of EN 1317 and is therefore a valuable tool for new product development and for injury biomechanics research.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objective: Cancer may impact negatively on an informal caregiver's health long after treatment has ended. This review identifies the self-report measures currently in use to measure caregivers need for support and determines their scientific soundness and clinical utility.

Method: A systematic electronic database search of Medline, CINAHL, PsychINFO, BNI ProQuest was conducted. The psychometric properties and clinical utility of needs assessment tools for caregivers of cancer survivors (excluding advanced disease) were extracted and summarised.

Results: Seven cancer survivor caregiver needs assessment tools were identified. Data on instrument development was well reported, although variability was noted in their structure and content. The majority demonstrated some degree of reliability and validity; only two were evaluated for test–retest reliability (CaSPUN and SPUNS) with only the SPUNS showing a high degree of reliability over time. The Health Care Needs Survey (HCNS), Needs Assessment of Family Caregivers-Cancer (NAFC-C) and Cancer Caregiving Tasks Consequences and Needs Questionnaire (CaTCoN) have been validated at various stages of the cancer continuum. Minimal data was available on responsiveness.

Conclusion: All assessment tools identified require further psychometric analysis. For research purposes, the use of the SPUNS (with its acceptable test–retest reliability) appears most appropriate; although its length may be of concern for clinical use; therefore, the shorter SCNS-P&C is likely to be more suitable for use clinically. At present, the NAFC-C demonstrates a great potential in both the research and clinical environments; however, it requires further psychometric testing before it can be fully recommended. Further analysis is necessary on ideal response formats and the meaning of a total needs score.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Physical modelling of musical instruments involves studying nonlinear interactions between parts of the instrument. These can pose several difficulties concerning the accuracy and stability of numerical algorithms. In particular, when the underlying forces are non-analytic functions of the phase-space variables, a stability proof can only be obtained in limited cases. An approach has been recently presented by the authors, leading to unconditionally stable simulations for lumped collision models. In that study, discretisation of Hamilton’s equations instead of the usual Newton’s equation of motion yields a numerical scheme that can be proven to be energy conserving. In this paper, the above approach is extended to collisions of distributed objects. Namely, the interaction of an ideal string with a flat barrier is considered. The problem is formulated within the Hamiltonian framework and subsequently discretised. The resulting nonlinearmatrix equation can be shown to possess a unique solution, that enables the update of the algorithm. Energy conservation and thus numerical stability follows in a way similar to the lumped collision model. The existence of an analytic description of this interaction allows the validation of the model’s accuracy. The proposed methodology can be used in sound synthesis applications involving musical instruments where collisions occur either in a confined (e.g. hammer-string interaction, mallet impact) or in a distributed region (e.g. string-bridge or reed-mouthpiece interaction).

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Hardware designers and engineers typically need to explore a multi-parametric design space in order to find the best configuration for their designs using simulations that can take weeks to months to complete. For example, designers of special purpose chips need to explore parameters such as the optimal bitwidth and data representation. This is the case for the development of complex algorithms such as Low-Density Parity-Check (LDPC) decoders used in modern communication systems. Currently, high-performance computing offers a wide set of acceleration options, that range from multicore CPUs to graphics processing units (GPUs) and FPGAs. Depending on the simulation requirements, the ideal architecture to use can vary. In this paper we propose a new design flow based on OpenCL, a unified multiplatform programming model, which accelerates LDPC decoding simulations, thereby significantly reducing architectural exploration and design time. OpenCL-based parallel kernels are used without modifications or code tuning on multicore CPUs, GPUs and FPGAs. We use SOpenCL (Silicon to OpenCL), a tool that automatically converts OpenCL kernels to RTL for mapping the simulations into FPGAs. To the best of our knowledge, this is the first time that a single, unmodified OpenCL code is used to target those three different platforms. We show that, depending on the design parameters to be explored in the simulation, on the dimension and phase of the design, the GPU or the FPGA may suit different purposes more conveniently, providing different acceleration factors. For example, although simulations can typically execute more than 3x faster on FPGAs than on GPUs, the overhead of circuit synthesis often outweighs the benefits of FPGA-accelerated execution.