987 resultados para poly-Weibull distribution
Resumo:
The generalized exponential distribution, proposed by Gupta and Kundu (1999), is a good alternative to standard lifetime distributions as exponential, Weibull or gamma. Several authors have considered the problem of Bayesian estimation of the parameters of generalized exponential distribution, assuming independent gamma priors and other informative priors. In this paper, we consider a Bayesian analysis of the generalized exponential distribution by assuming the conventional non-informative prior distributions, as Jeffreys and reference prior, to estimate the parameters. These priors are compared with independent gamma priors for both parameters. The comparison is carried out by examining the frequentist coverage probabilities of Bayesian credible intervals. We shown that maximal data information prior implies in an improper posterior distribution for the parameters of a generalized exponential distribution. It is also shown that the choice of a parameter of interest is very important for the reference prior. The different choices lead to different reference priors in this case. Numerical inference is illustrated for the parameters by considering data set of different sizes and using MCMC (Markov Chain Monte Carlo) methods.
Resumo:
Purpose - The purpose of this paper is to present designs for an accelerated life test (ALT). Design/methodology/approach - Bayesian methods and simulation Monte Carlo Markov Chain (MCMC) methods were used. Findings - In the paper a Bayesian method based on MCMC for ALT under EW distribution (for life time) and Arrhenius models (relating the stress variable and parameters) was proposed. The paper can conclude that it is a reasonable alternative to the classical statistical methods since the implementation of the proposed method is simple, not requiring advanced computational understanding and inferences on the parameters can be made easily. By the predictive density of a future observation, a procedure was developed to plan ALT and also to verify if the conformance fraction of the manufactured process reaches some desired level of quality. This procedure is useful for statistical process control in many industrial applications. Research limitations/implications - The results may be applied in a semiconductor manufacturer. Originality/value - The Exponentiated-Weibull-Arrhenius model has never before been used to plan an ALT. © Emerald Group Publishing Limited.
Resumo:
The synthesis of a series of omega-hydroxyfatty acid (omega-OHFA) monomers and their methyl ester derivatives (Me-omega-OHFA) from mono-unsaturated fatty acids and alcohols via ozonolysis-reduction/crossmetathesis reactions is described. Melt polycondensation of the monomers yielded thermoplastic poly(omega-hydroxyfatty acid)s [-(CH2)(n)-COO-](x) with medium (n = 8 and 12) and long (n = 17) repeating monomer units. The omega-OHFAs and Me-omega-OHFAs were all obtained in good yield (>= 80%) and purity (>= 97%) as established by H-1 NMR, Fourier Transform infra-red spectroscopy (FT-IR), mass spectroscopy (ESI-MS) and high performance liquid chromatography (HPLC) analyses. The average molecular size (M-n) and distribution (PDI) of the poly(omega-hydroxyfatty acid)s (P(omega-OHFA)s) and poly(omega-hydroxyfatty ester) s (P(Me-omega-OHFA) s) as determined by GPC varied with organo-metallic Ti(IV) isopropoxide [Ti(OiPr)(4)] polycondensation catalyst amount, reaction time and temperature. An optimization of the polymerization process provided P(omega-OHFA) s and P(Me-omega-OHFA) s with M-n and PDI values desirable for high end applications. Co-polymerization of the long chain (n = 12) and medium chain (n = 8) Me-omega-OHFAs by melt polycondensation yielded poly(omega-hydroxy tridecanoate/omega-hydroxy nonanoate) random co-polyesters (M-n = 11000- 18500 g mol(-1)) with varying molar compositions.
Resumo:
The local anesthetic articaine (ATC) is widely used in dentistry; however, its side effects can include paresthesia and nerve injury. Polymeric nanocapsules (PN) can be used as carriers for drugs, and help to reduce undesirable symptoms. The objective of this study was to evaluate the influence of different factors on the average size, polydispersion, and encapsulation efficiency of PN containing ATC. Poly(ε-caprolactone) (PCL) nanocapsules containing ATC were prepared by the oil-in-water emulsion/solvent evaporation method. The final ATC concentration was 2%. The preparation conditions were optimized using a central composite blocked cube-star design to investigate the influence of two variables at five levels, with 22 factorial points (–1 and +1), two replicates of the central point, 2×2 axial points (–1.414 and +1.414), and an orthogonal distribution, resulting in 10 experiments. The factors varied were the PVA concentration and the sonication time. The nanocapsules showed a satisfactory size range, a polydispersivity index less than 0.2, and high encapsulation efficiency. The values of the factors had no significant influence on either average size or polydispersion, although the encapsulation efficiency was significantly influenced by the sonication time. Improved formulations were identified using the central composite design, which revealed that the main consideration in selecting a suitable formulation was the encapsulation efficiency. Two of the formulations showed both high encapsulation efficiency and colloidal characteristics appropriate for the route of administration.
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
We introduce a five-parameter continuous model, called the McDonald inverted beta distribution, to extend the two-parameter inverted beta distribution and provide new four- and three-parameter sub-models. We give a mathematical treatment of the new distribution including expansions for the density function, moments, generating and quantile functions, mean deviations, entropy and reliability. The model parameters are estimated by maximum likelihood and the observed information matrix is derived. An application of the new model to real data shows that it can give consistently a better fit than other important lifetime models. (C) 2012 The Franklin Institute. Published by Elsevier Ltd. All rights reserved.
Resumo:
For any continuous baseline G distribution [G. M. Cordeiro and M. de Castro, A new family of generalized distributions, J. Statist. Comput. Simul. 81 (2011), pp. 883-898], proposed a new generalized distribution (denoted here with the prefix 'Kw-G'(Kumaraswamy-G)) with two extra positive parameters. They studied some of its mathematical properties and presented special sub-models. We derive a simple representation for the Kw-Gdensity function as a linear combination of exponentiated-G distributions. Some new distributions are proposed as sub-models of this family, for example, the Kw-Chen [Z.A. Chen, A new two-parameter lifetime distribution with bathtub shape or increasing failure rate function, Statist. Probab. Lett. 49 (2000), pp. 155-161], Kw-XTG [M. Xie, Y. Tang, and T.N. Goh, A modified Weibull extension with bathtub failure rate function, Reliab. Eng. System Safety 76 (2002), pp. 279-285] and Kw-Flexible Weibull [M. Bebbington, C. D. Lai, and R. Zitikis, A flexible Weibull extension, Reliab. Eng. System Safety 92 (2007), pp. 719-726]. New properties of the Kw-G distribution are derived which include asymptotes, shapes, moments, moment generating function, mean deviations, Bonferroni and Lorenz curves, reliability, Renyi entropy and Shannon entropy. New properties of the order statistics are investigated. We discuss the estimation of the parameters by maximum likelihood. We provide two applications to real data sets and discuss a bivariate extension of the Kw-G distribution.
Resumo:
Self-assembly of poly(4-vynil-N-alkyl)pyridinium bromide with alkyl side chains of 2, 5, 7, 10, or 16 carbons from ethanolic solutions onto flat silica surfaces was studied by means of ellipsometry, atomic force microscopy (AFM), contact angle measurements, and sum-frequency generation (SFG) vibrational spectroscopy in the CH3 and CH2 stretch region. Ab initio quantum-chemical calculations on the N-alkylpyridinium side-group with restricted Hartree-Fock (RHF) method and 6-311G (d,p) basis set were C one to estimate the charge distribution along the pyridinium ring and the alkyl side-chain. SFG results showed that longer side chains promote the disorientation of the alkyl groups at the surface, corroborating with the contact angle values. AFM images revealed film homogeneity, regardless the alkyl side group. However, after 24 h contact with water, ringlike structures appeared on the film surfaces, when the polycation alkyl side chain had 7 or less carbons, and as the alkyl chain increased to 10 or 16 carbons, the films dewetted because the hydrophobic interactions prevailed over the electrostatic interactions between the pyridinium charged groups and the negatively charged SiO2 surface. Under acid conditions (HCl 0.1 mol.L-1), the film mean thickness values decreased up to 50% of original values when the alkyl side chains were ethyl or pentyl groups due to ion-pair disruption, but for longer groups they remained unchanged. Quantum-chemical optimization and Mulliken electron population showed that (i) from C2 to C15 the positive charge at the headgroup (HG) decreased 0.025, while the charge at combined HG + alpha-CH2 increased 0.037; and (ii) for C6 or longer, the alkyl side group presents a tilt in the geometry, moving away from the plane. Such effects summed up over the whole polymer chain give support to suggest that when the side chains are longer than 7 carbons, the hydrophobic interaction decreases film stability and increases acid resistance.
Resumo:
This study aimed to demonstrate that microspheres, used as delivery vehicle of DNA-Hsp65/TDM [plasmid DNA encoding heat shock protein 65 (Hsp65) coencapsulated with trehalose dimycolate (TDM) into PLGA microspheres], are widely spread among several organs after intramuscular administration in BALB/c mice. In general, we showed that these particles were phagocytosed by antigen presenting cells, such as macrophages and dendritic cells. Besides, it was demonstrated herein that draining lymph node cells presented a significant increase in the number of cells expressing costimulatory molecules (CD80 and CD86) and MHC class II, and also that the administration of the DNA-Hsp65/TDM and vector/TDM formulations resulted in the up-regulation of CD80, CD86 and MHC class II expression when compared to control formulations (vector/TDM and empty). Regarding the intracellular trafficking we observed that following phagocytosis, the microspheres were not found in the late endosomes and/or lysosomes, until 15 days after internalization, and we suggest that these constructions were hydrolysed in early compartments. Overall, these data expand our knowledge on PLGA [poly (lactic-co- glycolic acid)] microspheres as gene carriers in vaccination strategies, as well as open perspectives for their potential use in clinical practice.
Resumo:
Triblock copolymers are made of monomer segments, being the central part usually hydrophobic and the outer parts hydrophilic. By varying sizes, molecular weights and monomer types of the segments one obtains different final molecules, with different physico-chemical properties, which are directly related to the performance of the final product. Looking for new products to be used, among other possibilities, in biological applications, a new polymer (Figure 1) was synthesized by the Dow Chemical and studied by Size Exclusion Chromatography, Fourier Transformed Infrared Spectrometry, Small-angle X-ray Scattering (SAXS) and its cloud point was determined by measuring light transmittance. The studies showed low molecular polydispersivety, but different polarities in the macromolecules fractions. Due to the low solubility of Diol in water, a mixture of water/butyl diglycol was used as solvent. An extensive analysis by SAXS was performed for concentrations from 50 wt% to 80 wt% of Diol in solution. Small concentrations showed very low signal to noise ratio, making it impossible to be analysed. The scattering intensity including the form factor of polydisperse non-homogeneous spheres, and the structure factor of interacting hard spheres was fitted to the curves. As the polymer concentration is high, the fitting of form factors of direct and reverse micelles were compared. The results for direct micelles were better up to 80 wt%, whereas at 90 wt% and 95 wt% the curves were better fitted by reverse micelles. It might seem odd that direct micelles are present up to such high concentrations, but it might have been caused by the presence of butyl diglycol, which increases the solubility of Diol in water. The inner and outer radius of the micelles, electron density distribution, and interaction radius of the micelles were obtained. The polydispersivety increases with Diol concentration. Besides, the interaction radius increases with solvent concentration, even when reversed micelles are present. In the last case, accompanied by an increase of inner radius (water content), as there are fewer Diol molecules to involve the water nuclei, which become larger, further apart, and in less number.
Resumo:
Zusammenfassung Die vorliegende Arbeit hat zum Ziel, pharmazeutisch-technologische Möglichkeiten der Retardierung bei ausgewählten Antiasthmatika zur pulmonalen Applikation anzuwenden. Dafür sollten Mikropartikel hergestellt und pharmazeutisch sowie biopharmazeutisch charakterisiert werden. Als Modellsubstanzen werden das Glukokortikoid Budesonid und das β2-Sympathomimetikum Salbutamol in Form seiner Base und seines Salzes verwendet. Die Auswahl erfolgt nach physikochemischen (Lipophilie, Molekulargewicht) und therapeutischen (Halbwertszeit der Wirkung, Applikationsfrequenz) Gesichtspunkten. Mikropartikel auf Polymerbasis ermöglichen eine kontrollierte Freigabe der Arzneistoffe über einen vorausbestimmten Zeitraum. Es erfolgt die Auswahl physiologisch unbedenklicher Hilfsstoffe (Polylaktide R 202H/ Poly(laktid-co-glykolide) RG 502H, RG 752-S) mit unterschiedlichen Anteilen an Coglykolid sowie unterschiedlichen Molekulargewichten, die sich prinzipiell zur Verzögerung der Freisetzung eignen und sich bei der parenteralen Applikation bereits bewährt haben. Die Sprühtrocknung wird als geeignetes pharmazeutisch-technologisches Verfahren zur Präparation von Mikropartikeln im Teilchengrößenbereich von 1- 10 Mikrometern beschrieben, welche den Wirkstoff mit möglichst hoher Beladung verkapselt. Die sprühgetrockneten Pulver sollen pharmazeutisch physikochemisch mittels Rasterelektronenmikroskopie (Morphologie), Laserdiffraktometrie (Teilchengrößenverteilung), DSC und Röntgenpulverdiffraktometrie (thermisches Verhalten) und mittels Stickstoff-Tief-Temperatur Adsorptionsverfahren (spezifische Oberfläche) charakterisiert werden. Zusätzlich wird die Wirkstoffbeladung der sprühgetrockneten Polymer-Mikropartikel mittels HPLC ermittelt. Die biopharmazeutische Charakterisierung der sprühgetrockneten Pulver erfolgt über die in-vitro Freigabekinetik und die Stabilität der Mikropartikel. Zusätzlich werden Versuche an Zellkulturen und in-vivo Versuche an Mäusen durchgeführt, um die Effekte der sprühgetrockneten Mikropartikel und des Hilfsstoffs hinsichtlich der Freisetzungsretardierung zu testen. Bei den in-vivo Versuchen werden der Atemwegswiderstand und die Verlängerung der exspiratorischen Phase (penh) als Parameter für einen antiasthmatischen Effekt gewählt. Die Lungenlavage Flüssigkeit wird zusätzlich überprüft. Die Ergebnisse zeigen, dass es mit Hilfe der Sprühtrocknung möglich ist, Polymer-Mikropartikel herzustellen, die aufgrund ihrer Partikelgröße von d50 ≤ 5,8 µm fähig sind, die unteren Abschnitte der Lunge zu erreichen. Die Morphologie der Mikropartikel ist abhängig vom zu versprühenden Produkt. Thermodynamisch und röntgenpulverdiffraktometrisch betrachtet handelt es sich um amorphe Produkte, die aber über lange Zeit in diesem Zustand stabil sind. Die Wiederfindung der eingesetzten Arzneistoffmenge in den sprühgetrockneten Polymer-Mikropartikeln und die Freigabeversuche zur Charakterisierung der Retardierungseigenschaften der verwendeten Polymere ergeben, dass es mit Hilfe der Sprühtrocknung von Budesonid und Salbutamol mit den Polymeren möglich ist, retardierende Mikropartikel herzustellen. Die Wiederfindung von Budesonid und Salbutamol in den sprühgetrockneten Polymer-Mikropartikeln entspricht nahezu der eingesetzten Menge. Bei Salbutamolsulfat ist dies nicht der Fall. In Zellkulturversuchen der murinen Zellinie RAW 264.7 ergaben sich Hinweise darauf, dass bei Konzentrationen von 10-6 M und 10-8 M, die Downregulation der IL-6 Konzentration durch die Sprüheinbettung von 9,1 % Budesonid mit PLGA in stärkerem Ausmaß erfolgte, als bei unverkapseltem Budesonid. Zusätzlich wurden in-vivo Versuche mit intranasaler und intraperitonealer Gabe durchgeführt. Die Budesonid-Polymer Sprüheinbettung wurde mit unverkapseltem Budesonid vergleichen. Nach intraperitonealer Gabe hatte die Sprüheinbettung mit Budesonid die besten Effekte hinsichtlich der Unterdrückung des penh und des Atemwegswiderstands auch bei steigenden Metacholinkonzentrationen. Die Auswertung der Lungenlavage Flüssigkeit zeigt sehr deutlich die Downregulation der IL-6 Konzentration in der Lunge durch die Sprüheinbettung mit Budesonid. Zur Zeit werden Vorbereitungen getroffen, ein Gerät zu testen, das in der Lage ist, ein Mikrospray zu generieren, so dass eine intratracheale Verabreichung möglich wäre.
Resumo:
Polymere Hohlstrukturen eignen sich um eine große Anzahl an Gastmolekülen zu verkapseln und bieten somit interessante Anwendungsmöglichkeiten, z.B. im Bereich kontrollierter Transportsysteme. Solche wohl definierten Strukturen lassen sich mittels des Sol-Gel-Prozesses durch Hydrolyse und Kondensation von Dialkoxydialkyl- und Trialkoxyalkylsilanen in wässriger Dispersion in Gegenwart von Tensiden synthetisieren. Die Methode ermöglicht den Aufbau verschiedener Kern-Schale-Systeme, inklusive Hohlkugelarchitekturen, mit Durchmessern von 10-100 nm. Abhängig von den eingestellten Parametern wird dabei eine bimodale Größenverteilung der Partikel beobachtet. Die bimodalen Proben wurden mittels der circularen asymmetrischen Fluss Feld-Fluss Fraktionierung (CAFFFE) fraktioniert. NMR-Untersuchungen deuten darauf hin, dass die Ursache der bimodalen Verteilung in der Synthese der Kerndispersion zu liegen scheint. MALDI-TOF-MS und GC-Messungen zeigen, dass der Kern der größeren Partikel ausschließlich aus zyklischen Kondensationsprodukten besteht, während im Kernmaterial der kleineren Partikel zusätzlich noch lineare Polydimethylsiloxan-Ketten vorhanden sind. Unter der Annahme, dass PDMS als Ultrahydrophob wirkt, lässt sich die Ostwaldreifung als Ursache der Bimodalität ausmachen. Eine Erhöhung des PDMS-Anteils, der zur Stabilisierung gegen den Reifungsprozess notwendig ist, führt zu einer monomodalen Verteilung der erhaltenen Partikel.
Resumo:
Postmortem minimal invasive angiography has already been implemented to support virtual autopsy examinations. An experimental approach in a porcine model to overcome an initially described artificial tissue edema artifact by using a poly ethylene glycol (PEG) containing contrast agent solution showed promising results. The present publication describes the first application of PEG in a whole corpse angiographic CT examination. A minimal invasive postmortem CT angiography was performed in a human corpse utilizing the high viscosity contrast agent solution containing 65% of PEG. Injection was carried out via the femoral artery into the aortic root in simulated cardiac output conditions. Subsequent CT scanning delivered the 3D volume data of the whole corpse. Visualization of the human arterial anatomy was excellent and the contrast agent distribution was generally limited to the arterial system as intended. As exceptions an enhancement of the brain, the left ventricular myocardium and the renal cortex became obvious. This most likely represented the stage of centralization of the blood circulation at the time of death with dilatation of the precapillary arterioles within these tissues. Especially for the brain this resulted in a distinctively improved visualization of the intracerebral structures by CT. However, the general tissue edema artifact of postmortem minimal invasive angiography examinations could be distinctively reduced.
Resumo:
Around 14 distinct virus species-complexes have been detected in honeybees, each with one or more strains or sub-species. Here we present the initial characterization of an entirely new virus species-complex discovered in honeybee (Apis mellifera L.) and varroa mite (Varroa destructor) samples from Europe and the USA. The virus has a naturally poly-adenylated RNA genome of about 6500 nucleotides with a genome organization and sequence similar to the Tymoviridae (Tymovirales; Tymoviridae), a predominantly plant-infecting virus family. Literature and laboratory analyses indicated that the virus had not previously been described. The virus is very common in French apiaries, mirroring the results from an extensive Belgian survey, but could not be detected in equally-extensive Swedish and Norwegian bee disease surveys. The virus appears to be closely linked to varroa, with the highest prevalence found in varroa samples and a clear seasonal distribution peaking in autumn, coinciding with the natural varroa population development. Sub-genomic RNA analyses show that bees are definite hosts, while varroa is a possible host and likely vector. The tentative name of Bee Macula-like virus (BeeMLV) is therefore proposed. A second, distantly related Tymoviridae-like virus was also discovered in varroa transcriptomes, tentatively named Varroa Tymo-like virus (VTLV).
Confined crystallization of nanolayered poly(ethylene terephthalate) using X-ray diffraction methods
Resumo:
The development of crystalline lamellae in ultra-thin layers of poly(ethylene terephthalate) PET confined between polycarbonate (PC) layers in an alternating assembly is investigated as a function of layer thickness by means of X-ray diffraction methods. Isothermal crystallization from the glassy state is in-situ followed by means of small-angle X-ray diffraction. It is found that the reduced size of the PET layers influences the lamellar nanostructure and induces a preferential lamellar orientation. Two lamellar populations, flat-on and edge-on, are found to coexist in a wide range of crystallization temperatures (Tc = 117–150 °C) and within layer thicknesses down to 35 nm. Flat-on lamellae appear at a reduced crystallization rate with respect to bulk PET giving rise to crystals of similar dimensions separated by larger amorphous regions. In addition, a narrower distribution of lamellar orientations develops when the layer thickness is reduced or the crystallization temperature is raised. In case of edge-on lamellae, crystallization conditions also influence the development of lamellar orientation; however, the latter is little affected by the reduced size of the layers. Results suggest that flat-on lamellae arise as a consequence of spatial confinement and edge-on lamellae could be generated due to the interactions with the PC interface. En este trabajo se investiga mediante difracción de rayos X a ángulos bajos (SAXS) y a ángulos altos (WAXS), la cristalización de láminas delgadas de Polietilén tereftalato (PET) confinadas entre láminas de Policarbonato (PC), tomando como referencia PET sin confinar. El espesor de las capas de PET varía entre 35nm y 115 nm. Se realizaron medidas de difracción a tres temperaturas de cristalización (117ºC, 132ºC y 150ºC) encontrándose que el reducido espesor de las capas de PET influye en la estructura lamelar que se desarrolla, induciendo una orientación preferente de las láminas. Se integró la intensidad difractada alrededor del máximo en SAXS para obtener una representación de la intensidad en función del ángulo acimutal. Mediante análisis de mínimos cuadrados se separó la curva experimental obtenida en tres contribuciones diferentes: una función Gausiana que describe la distribución de las orientaciones de las lamelas, una función lorenziana asociada a los máximos meridionales (asociados a las interfases PET-PC) y un background constante. Por otra parte la cantidad de material cristalizado se estimó asumiendo que la intensidad del background en el barrido acimutal, una vez restado el background del primer difractograma (sin máximos en SAXS) se asocia con la contribución del material isotrópico que resta en la muestra cristalizada. Se observa la coexistencia de dos poblaciones de lamelas: flat-on y edge-on. A medida que el espesor de las láminas de PET disminuye la población de las lamelas flat-on experimenta los siguientes cambios: 1) la distribución de orientación se estrecha, 2) la fracción de material cristalizado orientado aumenta, 3) la cinética de cristalización se ralentiza y 4) el largo espaciado aumenta es decir las regiones amorfas entre lamelas aumentan su tamaño. Parece demostrarse que es en las primeras etapas del crecimiento lamelar cuando la restricción espacial fuerza a las lamelas a esta orientación tipo flat-on frente a la orientación edge-on.