948 resultados para passive safety systems


Relevância:

40.00% 40.00%

Publicador:

Resumo:

Mode of access: Internet.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

We propose a novel approach to characterize the parabolically-shaped pulses that can be generated from more conventional pulses via nonlinear propagation in cascaded sections of commercially available normally dispersive (ND) fibers. The impact of the initial pulse chirp on the passive pulse reshaping is examined. We furthermore demonstrate that the combination of pulse pre-chirping and propagation in a single ND fiber yields a simple, passive method for generating various temporal waveforms of practical interest.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

This thesis describes a study of the content and applicability of BS8800:1996 Guide to occupational health and safety management systems. The research is presented chronologically, with literature review and content analysis of SMS related guides and standards interwoven with two elements of qualitative empirical work. The first of these was carried out shortly after publication of BS8800 in 1996, a 'before-the-event' investigation of how organisations were intending to approach SMS implementation. The challenges faced by these organisations are reviewed against standard management theory, suggesting that the initial motivation for SMS implementation governs the approach organisations will adopt to guidance such as BS8800. The second phase of empirical work was undertaken in the context of OHSAS 18001, an auditable protocol based on BS8800, which allows organisations to certify their safety management systems. A discussion of the evolution of certifiable safety management system is presented, highlighting the similarities and differences between this, BS8800, SMS and wider management system standards. A case study then reviews the experiences of a catering company that implemented 18001, motivated by the opportunity for certification as a business benefit. The empirical work is used to comment on the guidance provided by BS8800, within its evolved role as guidance organisations may use for implementation of a SMS to be certified according to the specifications of OHSAS 18001. It is suggested that optimal implementation is facilitated by initial status review, continual improvement and the use of annexes, where there are used to make changes to the existing safety management system. This thesis concludes with a discussion of these elements, highlighting pertinent areas within BS8800 where revision or amendment may be appropriate.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

The specific objective of the research was to evaluate proprietary audit systems. Proprietary audit systems comprise question sets containing approximately 500 questions dealing with selected aspects of health and safety management. Each question is allotted a number of points and an organisation seeks to judge its health and safety performance by the overall score achieved in the audit. Initially it was considered that the evaluation method might involve comparing the proprietary audit scores with other methods of measuring safety performance. However, what appeared to be missing in the first instance was information that organisations could use to compare the contrast question set content against their own needs. A technique was developed using the computer database FileMaker Pro. This enables questions in an audit to be sorted into categories using a process of searching for key words. Questions that are not categorised by word searching can be identified and sorted manually. The process can be completed in 2-3 hours which is considerably faster than manual categorisation of questions which typically takes about 10 days. The technique was used to compare and contrast three proprietary audits: ISRS, CHASE and QSA. Differences and similarities between these audits were successfully identified. It was concluded that in general proprietary audits need to focus to a greater extent on identifying strengths and weaknesses in occupational health and safety management systems. To do this requires the inclusion of more probing questions which consider whether risk control measures are likely to be successful.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Research in safety management has been inhibited by lack of consensus as to the definitions of the terms with which it is concerned and, in general, the lack of an agreed theoretical framework within which to collate and contrast empirical findings. This thesis sets out definitions of key terms (hazard, risk, accident, incident and safety) and provides a theoretical framework. This framework has been informed by many sources but especially the Management Oversight and Risk Tree (MORT), cybernetics and the Viable System Model (VSM). Fieldwork designs are proposed for the empirical development of an analytical framework and its use to assist study of the development of safety management in organisations.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

A method of all-optical passive quasi-regeneration in transoceanic 40 Gbit/s return-to-zero transmission systems with strong dispersion management was described. The use of in-line nonlinear optical loop mirrors (NOLM) by the method was demonstrated. The quasi-regeneration of signals performed by NOLMs was found to improve the systems's performance.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

All-optical passive regeneration in 40 Gbit/s-based wavelength-division-multiplexed (WDM) dispersion-managed return-to-zero (RZ) transmission system was discussed. In-line nonlinear optical loop mirrors (NOLM) were used. A feasibility of 300 GHz-spaced two channel unlimited transmission and 150 GHz-spaced two channel 25000 km transmission over the standard fiber were found.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

The poor retention and efficacy of instilled drops as a means of delivering drugs to the ophthalmic environment is well-recognised. The potential value of contact lenses as a means of ophthalmic drug delivery, and consequent improvement of pre-corneal retention is one obvious route to the development of a more effective ocular delivery system. Furthermore, the increasing availability and clinical use of daily disposable contact lenses provides the platform for the development of viable single-day use drug delivery devices based on existing materials and lenses. In order to provide a basis for the effective design of such devices, a systematic understanding of the factors affecting the interaction of individual drugs with the lens matrix is required. Because a large number of potential structural variables are involved, it is necessary to achieve some rationalisation of the parameters and physicochemical properties (such as molecular weight, charge, partition coefficients) that influence drug interactions. Ophthalmic dyes and structurally related compounds based on the same core structure were used to investigate these various factors and the way in which they can be used in concert to design effective release systems for structurally different drugs. Initial studies of passive diffusional release form a necessary precursor to the investigation of the features of the ocular environment that over-ride this simple behaviour. Commercially available contact lenses of differing structural classifications were used to study factors affecting the uptake of the surrogate actives and their release under 'passive' conditions. The interaction between active and lens material shows considerable and complex structure dependence, which is not simply related to equilibrium water content. The structure of the polymer matrix itself was found to have the dominant controlling influence on active uptake; hydrophobic interaction with the ophthalmic dye playing a major role. © The Author(s) 2014 Reprints and permissions: sagepub.co.uk/journalsPermissions.nav.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Progress on advanced active and passive photonic components that are required for high-speed optical communications over hollow-core photonic bandgap fiber at wavelengths around 2 μm is described in this paper. Single-frequency lasers capable of operating at 10 Gb/s and covering a wide spectral range are realized. A comparison is made between waveguide and surface normal photodiodes with the latter showing good sensitivity up to 15 Gb/s. Passive waveguides, 90° optical hybrids, and arrayed waveguide grating with 100-GHz channel spacing are demonstrated on a large spot-size waveguide platform. Finally, a strong electro-optic effect using the quantum confined Stark effect in strain-balanced multiple quantum wells is demonstrated and used in a Mach-Zehnder modulator capable of operating at 10 Gb/s.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Cyber-physical systems tightly integrate physical processes and information and communication technologies. As today’s critical infrastructures, e.g., the power grid or water distribution networks, are complex cyber-physical systems, ensuring their safety and security becomes of paramount importance. Traditional safety analysis methods, such as HAZOP, are ill-suited to assess these systems. Furthermore, cybersecurity vulnerabilities are often not considered critical, because their effects on the physical processes are not fully understood. In this work, we present STPA-SafeSec, a novel analysis methodology for both safety and security. Its results show the dependencies between cybersecurity vulnerabilities and system safety. Using this information, the most effective mitigation strategies to ensure safety and security of the system can be readily identified. We apply STPA-SafeSec to a use case in the power grid domain, and highlight its benefits.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Background Patient safety is concerned with preventable harm in healthcare, a subject that became a focus for study in the UK in the late 1990s. How to improve patient safety, presented both a practical and a research challenge in the early 2000s, leading to the eleven publications presented in this thesis. Research question The overarching research question was: What are the key organisational and systems factors that impact on patient safety, and how can these best be researched? Methods Research was conducted in over 40 acute care organisations in the UK and Europe between 2006 and 2013. The approaches included surveys, interviews, documentary analysis and non-participant observation. Two studies were longitudinal. Results The findings reveal the nature and extent of poor systems reliability and its effect on patient safety; the factors underpinning cases of patient harm; the cultural issues impacting on safety and quality; and the importance of a common language for quality and safety across an organisation. Across the publications, nine key organisational and systems factors emerged as important for patient safety improvement. These include leadership stability; data infrastructure; measurement capability; standardisation of clinical systems; and creating an open and fair collective culture where poor safety is challenged. Conclusions and contribution to knowledge The research presented in the publications has provided a more complete understanding of the organisation and systems factors underpinning safer healthcare. Lessons are drawn to inform methods for future research, including: how to define success in patient safety improvement studies; how to take into account external influences during longitudinal studies; and how to confirm meaning in multi-language research. Finally, recommendations for future research include assessing the support required to maintain a patient safety focus during periods of major change or austerity; the skills needed by healthcare leaders; and the implications of poor data infrastructure.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

This report examines the Genesis II irradiator made by Gray*Star Incorporated, Mississippi Department of Health radiation safety regulations, and Nuclear Regulatory Commission (NRC) inspection guidelines for irradiators. The purpose for this report is to evaluate any hazards which may lead to a catastrophic water loss, evaluate protective action distances during a reduced shielding situation, and evaluate the safety engineering measures incorporated by Mississippi and Federal regulations to ensure the mitigation of risk for pool irradiators. Due to safeguard controls prohibiting release of precise data on emergency response measures and radioactivity of the isotopes utilized this report will be focused on regulations mandating specific engineering controls and manufacturer recommended guidelines for best practices.