999 resultados para parent material
Resumo:
Objective: premature infants are at increased risk of developmental disability. Early identification of problems allows intervention to ameliorate or attenuate problems. A reliable screening tool allows triage of children in this high-risk population by identifying those unlikely to need full developmental assessment. To explore the test characteristics of an established parent-completed developmental assessment questionnaire 'Ages and Stages Questionnaire' (ASQ) in follow up of an Australian population of premature infants. Methodology: One hundred and sixty-seven children born prematurely with corrected ages 12- to 48-months attending the Growth and Development Clinic at the Mater Children's Hospital in Brisbane, Queensland, Australia; 136 questionnaires 'ASQ' were returned completed (81%) and were compared to formal psychometric assessment (Griffith Mental Development Scales for 12- and 24-months, Bayley Mental Development Intelligence Scale for 18-months, McCarthy General Cognitive Intelligence Scale for 18-months). Developmental delay was considered to be present if any of the above psychometric assessments fell below 1.0 standard deviations (SD). The ASQ cut-off used was 2.0 SD (US data derived means and SD). Results: Aggregate results for all age groups comparing ASQ to psychometric assessments as 'gold standards' found the ASQ to have the following test characteristics: sensitivity (90%); specificity (77%); positive predictive value (40%); negative predictive value (98%): % over-referred (20%); % under-referred (1%); % agreement (79%). likelihood ratio for children failing the ASQ was 3.8 and for passing the ASQ was 0.13. Twenty-one children with known disabilities were included in the study and in 14 of these, the ASQ overall score agreed with the psychometric assessment (67%). Conclusion: The high negative predictive value of the ASQ supports its use as a screening tool for cognitive and motor delays in the follow up of ex-premature infants. This would need to be combined with other strategies as part of a comprehensive follow up program for ex-premature infants.
Briefing: Factored material properties and limit state loads-unlikely extreme or impossible pretense
Resumo:
In the limit state design (LSD) method each design criterion is formally stated and assessed using a performance function. The performance function defines the relationship between the design parameters and the design criterion. In practice, LSD involves factoring up loads and factoring down calculated strengths and material parameters. This provides a convenient way to carry out routine probabilistic-based design. The factors are statistically calculated to produce a design with an acceptably low probability of failure. Hence the ultimate load and the design material properties are mathematical concepts that have no physical interpretation. They may be physically impossible. Similarly, the appropriate analysis model is also defined by the performance function and may not describe the real behaviour at the perceived physical equivalent limit condition. These points must be understood to avoid confusion in the discussion and application of partial factor LSD methods.
Resumo:
The paper considers the structural identifiability of a parent–metabolite pharmacokinetic model for ivabradine and one of its metabolites. The model, which is linear, is considered initially for intravenous administration of ivabradine, and then for a combined intravenous and oral administration. In both cases, the model is shown to be unidentifiable. Simplification of the model (for both forms of administration) to that proposed by Duffull et al. (1) results in a globally structurally identifiable model. The analysis could be applied to the modeling of any drug undergoing first-pass metabolism, with plasma concentrations available from drug and metabolite.
Resumo:
This study was a trial of an intervention programme aimed to improve parental self-efficacy in the management of problem behaviours associated with Asperger syndrome. The intervention was compared across two formats, a I day workshop and six individual sessions, and also with a non-intervention control group. The results indicated that, compared with the control group, parents in both intervention groups reported fewer problem behaviours and increased self-efficacy following the interventions, at both 4 weeks and 3 months follow-up. The results also showed a difference in self-efficacy between mothers and fathers, with mothers reporting a significantly greater increase in self-efficacy following intervention than fathers. There was no significant difference between the workshop format and the individual sessions.
Resumo:
Objective: To investigate the impact characteristics of an ethylene vinyl acetate (EVA) mouthguard material with regulated air inclusions, which included various air cell volumes and wall thickness between air cells. In particular, the aim was to identify the magnitude and direction of forces within the impacts. Method: EVA mouthguard material, A mm thick and with and without air inclusions, was impacted with a constant force impact pendulum with an energy of 4.4 J and a velocity of 3 m/s. Transmitted forces through the EVA material were measured using an accelerometer, which also allowed the determination of force direction and magnitude within the impacts. Results: Statistically significant reductions in the transmitted forces were observed with all the air inclusion materials when compared with EVA without air inclusions. Maximum transmitted force through one air inclusion material was reduced by 32%. Force rebound was eliminated in one material, and reduced second force impulses were observed in all the air inclusion materials. Conclusion: The regulated air inclusions improved the impact characteristics of the EVA mouthguard material, the material most commonly used in mouthguards world wide.
Effect of ethylene vinyl acetate (EVA) closed cell foam on transmitted forces in mouthguard material
Resumo:
Objectives: To compare transmitted forces through ethylene vinyl acetate (EVA) mouthguard material and the same EVA material with gas inclusions in the form of a closed cell foam. Method: EVA mouthguard materials with and without foam gas inclusions and 4 mm thick were impacted with a constant force from an impact pendulum. Various porosity levels in the foam materials were produced by 1%, 5%, and 10% by weight foaming agent. The forces transmitted through the EVA after energy absorption by the test materials were measured with a force sensor and compared. Results: Only minor non-significant differences in transmitted forces through the EVA with and without foam were shown. Conclusions: The inclusion of gas in the form of a closed cell foam in 4 mm thick EVA mouthguard materials did not improve the impact performance of the EVA mouthguard material.
Resumo:
The emphasis of this work is on the optimal design of MRI magnets with both superconducting coils and ferromagnetic rings. The work is directed to the automated design of MRI magnet systems containing superconducting wire and both `cold' and `warm' iron. Details of the optimization procedure are given and the results show combined superconducting and iron material MRI magnets with excellent field characteristics. Strong, homogeneous central magnetic fields are produced with little stray or external field leakage. The field calculations are performed using a semi-analytical method for both current coil and iron material sources. Design examples for symmetric, open and asymmetric clinical MRI magnets containing both superconducting coils and ferromagnetic material are presented.
Resumo:
Magnetic resonance imaging (MRI) magnets have very stringent constraints on the homogeneity of the static magnetic field that they generate over desired imaging regions. The magnet system also preferably generates very little stray field external to its structure, so that ease of siting and safety are assured. This work concentrates on deriving, means of rapidly computing the effect of 'cold' and 'warm' ferromagnetic material in or around the superconducting magnet system, so as to facilitate the automated design of hybrid material MR magnets. A complete scheme for the direct calculation of the spherical harmonics of the magnetic field generated by a circular ring of ferromagnetic material is derived under the conditions of arbitrary external magnetizing fields. The magnetic field produced by the superconducting coils in the system is computed using previously developed methods. The final, hybrid algorithm is fast enough for use in large-scale optimization methods. The resultant fields from a practical example of a 4 T, clinical MRI magnet containing both superconducting coils and magnetic material are presented.