978 resultados para occult blood test
Resumo:
Borderline hypertension (BH) has been associated with an exaggerated blood pressure (BP) response during laboratory stressors. However, the incidence of target organ damage in this condition and its relation to BP hyperreactivity is an unsettled issue. Thus, we assessed the Doppler echocardiographic profile of a group of BH men (N = 36) according to office BP measurements with exaggerated BP in the cycloergometric test. A group of normotensive men (NT, N = 36) with a normal BP response during the cycloergometric test was used as control. To assess vascular function and reactivity, all subjects were submitted to the cold pressor test. Before Doppler echocardiography, the BP profile of all subjects was evaluated by 24-h ambulatory BP monitoring. All subjects from the NT group presented normal monitored levels of BP. In contrast, 19 subjects from the original BH group presented normal monitored BP levels and 17 presented elevated monitored BP levels. In the NT group all Doppler echocardiographic indexes were normal. All subjects from the original BH group presented normal left ventricular mass and geometrical pattern. However, in the subjects with elevated monitored BP levels, fractional shortening was greater, isovolumetric relaxation time longer, and early to late flow velocity ratio was reduced in relation to subjects from the original BH group with normal monitored BP levels (P<0.05). These subjects also presented an exaggerated BP response during the cold pressor test. These results support the notion of an integrated pattern of cardiac and vascular adaptation during the development of hypertension.
Resumo:
In medical emergency situations, when a patient needs a blood transfusion, the universal blood type O− is administered. This procedure may lead to the depletion of stock reserves of O− blood. Nowadays, there is no commercial equipment capable of determining the patient's blood type in situ, in a fast and reliable process. Human blood typing is usually performed through the manual test, which involves a macroscopic observation and interpretation of the results by an analyst. This test, despite of having a fast response time, may lead to human errors, which sometimes can be fatal to the patient. This paper presents the development of an automatic mechatronic prototype for determining human blood typing (ABO and Rh systems) through image processing techniques. The prototype design takes into account the characteristics of reliability of analysis, portability, and response time allowing the system to be used in emergency situations. The developed prototype performs blood and reagents mixture acquires the resultant image and processes the data (based on image processing techniques) to determine the sample blood type. It was tested in a laboratory, using cataloged samples of blood types, provided by the Portuguese Institute of Blood and Transplantation. Hereafter, it is expected to test and validate the prototype in clinical environments.
Resumo:
The study was carried out to evaluate the diagnostic performance of the ICT malaria Pf/PvTM test for vivax malaria diagnosis in Belém, Amazon region, Brazil. The results of blood malaria parasites examination using an immunochromatography test were compared with thick blood film (TBF) examination. It was also evaluated the performance of this test storaged at three different temperatures (25°C, 30°C, and 37°C) for 24 hours before use. Overall sensitivity of ICT Pf/PvTM was 61.8% with a specificity of 100%, positive and negative predictive value of 100% and 71.8%, respectively and accuracy of 80.6%. The test sensitivity was independent of the parasite density. This test needs to be further reviewed in order to have better performance for P. vivax malaria diagnosis.
Resumo:
The prevalence and clinical forms of Trypanosoma cruzi were evaluated among blood donor candidates attended at a general hospital in Rio de Janeiro, Brazil, from January 1997 to April 1999. The investigation was done by means of the indirect hemagglutination test and was confirmed via ELISA. Data were collected from clinical examinations, conventional electrocardiogram, chest radiography and echocar-diography. The results showed that despite Trypanosoma cruzi prevalence of 1.17% (128 patients), mainly in males aged 40 years or over, 70.8% of these patients, mainly males aged 19 to 39 years, demonstrated abnormalities that allowed the diagnosis of cardiopathy and/or esophagopathy. This once again corroborates the importance of Trypanosoma cruzi infection in urban centers.
Resumo:
Dissertação de Mestrado, Ciências Biomédicas, 3 de Fevereiro de 2016, Universidade dos Açores.
Resumo:
A comparison of two different standardized reagent procedures for the passive haemagglutination test (PHA) in the detection of specific antibody to Cysticercus cellulosae in cerebrospinal fluid (CSF) was carried out. The formaldehyde-treated group O Rh-human red blood cells (HuRBC) and glutaraldehyde-treated sheep red blood cells (SRBC) were the supplies for the reagents preparation and, in the tests, they were designated as PHA-1 and PHA-2, respectively. For both reagents the cells were coated with the cysticerci total saline extract (TS) antigen. PHA-1 and PHA-2 were assessed in a total of 204 CSF from patients with neurocysticercosis, from non-related infections and from healthy individuals. The positivity and specificity indices obtained were respectively 81.7% and 94.4% for PHA-1 and for PHA-2, 88.7% and 96.6%. Since no significant differences were observed between the results provided by two reagents, at level of significance of 0.05, either processes of cell sensitization can alternatively be used according to the own laboratory convenience.
Resumo:
Between October 1988 and April 1989 a cross-sectional survey was carried out in six out of eight blood banks of Goiânia, Central Brazil. Subjects attending for first-time blood donation in the mornings of the study period (n = 1358) were interviewed and screened for T. cruzi infection as a part of a major study among blood donors. Tests to anti-T. cruzi antibodies were performed, simultaneously, by indirect hem agglutination test (IHA) and complement fixation test (CFT). A subject was considered seropositive when any one of the two tests showed a positive result. Information on age, sex, place of birth, migration and socio-economic level was recorded. Results from this survey were compared with seroprevalence rates obtained in previous studies in an attempt to analyse trend of T. cruzi infection in an endemic urban area. The overall seroprevalence of T. cruzi infection among first-time donors was found to be 3.5% (95% confidence interval 2.5%-4.5% ). The seroprevalence rate increased with age up to 45 years and then decreased. Migrants from rural areas had higher seroprevalence rates than subjects from urban counties (1.8%-16.2% vs. 0%-3.6%). A four fold decrease in prevalence rates was observed when these rates were compared with those of fifteen years ago. Two possible hypotheses to explain this difference were suggested: 1. a cohort effect related with the decrease of transmission in rural areas and/or 2. a differential proportion of people of rural origin among blood donors between the two periods. The potential usefulness of blood banks as a source of epidemiological information to monitor trends of T. cruzi infection in an urban adult population was stressed.
Resumo:
Indirect Immunofluorescence (IFA), Plaque Reduction Neutralization (PRN) and Haemagglutination Inhibition (HI) tests for measles antibodies were carried out in 197 sera obtained from umbilical cord and vaccinated children. The IFA was also applied to blood samples collected with filter paper. IFA results demonstrated that the test is relatively simple to perform, with good reproducibility for different antigen lots. Good correlation was obtained between IFA, PRN and HI antibody titers. Better correlation was demonstrated with IFA and PRN than with HI and PRN tests. Sensitivity of IFA in detecting antibody was less effective than PRN, however more effective than HI using rhesus monkey red blood cells. PRN antibody titers over 100 were detected by IFA but not by HI (9.7% with negative results). IFA may be of considerable practical use and able to substitute HI in Seroepidemiological surveys and to evaluate vaccine efficacy. It also can be simplified by employing filter paper collected samples.
Resumo:
A laboratory study was conducted to test the toxicity of synthetic insecticides added to defibrinated sheep blood kept at room temperature and offered as food to the following triatomine species: Triatoma infestans, Panstrongylus megistus, Triatoma vitticeps, Triatoma pseudomaculata, Triatoma brasiliensis and Rhodnius prolixus. The insecticides used, at a concentration of 1g/l, were: HCH, DDT, Malathion and Trichlorfon, and the lethalithy observed at the end of a 7-day period varied according to the active principle of each. HCH was the most effective by the oral route, killing 100% of the insects, except P. megistus (95.7%) and T. pseudomaculata (94.1%). Trichlorfon killed the insects at rates ranging from 71.8% (T. vitticeps) to 98% (R. prolixus). Malathion was slightly less efficient, killing the insects at rates from 56.8% (T. vitticeps) to 97% (T.brasiliensis). DDT was the least effective, with a killing rate of 10% (T. vitticeps) to 75% (T.brasiliensis). Since the tests were performed at room temperature, we suggest that baits of this type should be tried for the control of triatomines in the field.
Resumo:
A hemagglutination (HA) test was standardized using formalin- and tannin-treated gander red blood cells sensitized with a total salt extract of C. cellulosae (HA-Cc) and an antigenic extract of Cysticercus longicollis (HA-Cl) vesicular fluid. A total of 61 cerebrospinal fluid (CSF) samples were assayed, 41 from patients with neurocysticercosis and 20 from a control group, which were, respectively, reactive and non-reactive to ELISA using C. cellulosae. The CSF samples from the control group did not react and 35 (85.4%) and 34 (82.9%) CSF samples from patients were reactive to the HA-Cc and HA-Cl tests, respectively. The reagents ready for use were stable up to 6 months when stored at 4°C in 50% glycerol. The present results confirm that the reagent using Cysticercus longicollis stabilized with glycerol can be used as an alternative in the immunological diagnosis of neurocysticercosis
Resumo:
The clinical and public health importance of indeterminate results in HIV-1/2 testing is still difficult to evaluate in volunteer blood donors. At Fundação Hemominas, HIV-1/2 ELISA is used as the screening test and, if reactive, is followed by Western blot (WB). We have evaluated 84 blood donors who had repeatedly reactive ELISA tests for HIV-1/2, but indeterminate WB results. Sixteen of the 84 donors (19.0%) had history of sexually transmitted diseases; 18/84 (21.4%) informed receiving or paying for sex; 3/84 (3.6%) had homosexual contact; 2/26 women (7.6%) had past history of multiple illegal abortions and 3/84 (3.6%) had been previously transfused. Four out of 62 donors (6.5%) had positive anti-nuclear factor (Hep2), with titles up to 1:640. Parasitological examination of the stool revealed eggs of S. mansoni in 4/62 (6.4%) donors and other parasites in 8/62 (12.9%). Five (5.9%) of the subjects presented overt seroconversion for HIV-1/2, 43/84 (51.2%) had negative results on the last visit, while 36/84 (42.9%) remained WB indeterminate. Although some conditions could be found associated with the HIV-1/2 indeterminate WB results and many donors had past of risky behavior, the significance of the majority of the results remains to be determined.
Resumo:
Between 1992 and 1997, 790 blood donors with anti-HCV EIA-2 strongly reagent (relationship between the sample optical density/cut-off > 3) detected at the blood bank serological screening, were evaluated in ambulatory environment. They were all negative for Chagas disease, syphilis, hepatitis B (HBsAg) and AIDS. Blood samples were collected at the first ambulatorial evaluation, for hemogram, biochemical tests and new serological tests for HCV (anti-HCV EIA-2). In blood samples of 226 repeatedly reagent anti-HCV EIA-2 blood donors, supplementary "immunoblot" test for HCV (RIBA-2) was used. In 209 donors, the presence of HCV-RNA was investigated by the PCR test. The abdominal ultrasonography was realized in 366 donors. In 269 patients liver biopsy was performed for the histopathological study. The follow-up of blood donors showed that 95.6% were repeatedly EIA-2 reagent, 94% were symptomless and denied any hepatitis history, with only 2% mentioning previous jaundice. In 47% of this population at least one risk factor has been detected for the HCV transmission, the use of intravenous drugs being the main one (27.8%). Blood transfusion was the second factor for HCV transmission (27.2%). Hepatomegaly was detected in 54% of the cases. Splenomegaly and signs of portal hypertension have seldom been found in the physical examination, indicating a low degree of hepatic compromising in HCV. Abdominal ultrasound showed alterations in 65% of the subjects, being the steatosis the most frequent (50%). In 83.5% of the donors submitted to the liver biopsy, the histopathological exam showed the presence of chronic hepatitis, usually classified as active (89%) with mild or moderate grade in most of the cases (99.5%). The histopathological exam of the liver was normal in 1.5% of blood donors. The RIBA-2 test and the HCV-RNA investigation by PCR were positive in respectively 91.6 and 75% of the anti-HCV EIA-2 reagent donors. The HCV-RNA research was positive in 82% of the RIBA-2 positive subjects, in 37.5% of the indeterminate RIBA-2 donors and in 9% of the negative RIBA-2 donors. Chronic hepatitis has also been observed in 50% of the histopathological exams of the anti-HCV EIA-2 reagent donors which were indeterminate RIBA-2. Among 18 blood donors with minimal changes histopathological exam 11 (61%) were HCV-RNA positive. Our blood donors anti-HCV reagent generally had clinical, laboratorial and histopathological features observed in patients with chronic HCV hepatitis and a high proportion could be identified in interviews and medical evaluation realized in blood blanks. Generally, these HCV infected donors are identified and discharged only by the serological tests results.
Resumo:
In occupational accidents involving health professionals handling potentially contaminated material, the decision to start or to continue prophylactic medication against infection by Human Immunodeficiency Virus (HIV) has been based on the ELISA test applied to a blood sample from the source patient. In order to rationalize the prophylactic use of antiretroviral agents, a rapid serologic diagnostic test of HIV infection was tested by the enzymatic immunoabsorption method (SUDS HIV 1+2, MUREX®) and compared to conventional ELISA (Abbott HIV-1/ HIV-2 3rd Generation plus EIA®). A total of 592 cases of occupational accidents were recorded at the University Hospital of Ribeirão Preto from July 1998 to April 1999. Of these, 109 were simultaneously evaluated by the rapid test and by ELISA HIV. The rapid test was positive in three cases and was confirmed by ELISA and in one the result was inconclusive and later found to be negative by ELISA. In the 106 accidents in which the rapid test was negative no prophylactic medication was instituted, with an estimated reduction in costs of US$ 2,889.35. In addition to this advantage, the good correlation of the rapid test with ELISA, the shorter duration of stress and the absence of exposure of the health worker to the adverse effects of antiretroviral agents suggest the adoption of this test in Programs of Attention to Accidents with Potentially Contaminated Material.
Resumo:
The clinical significance of isolated anti-HBc is still a challenge. To elucidate the real importance of this finding in our blood donors, an investigation algorithm was tested. One hundred and twelve isolated anti-HBc seropositive blood donors underwent clinical evaluation and retesting of HBV markers. Those who presented repeatedly reactive isolated anti-HBc, received a single dose of hepatitis B recombinant vaccine to verify anti-HBs early response. A HBV-DNA determination by PCR was done for those who did not test positive to anti-HBs after vaccine. The level of anti-HBc was recorded as a ratio of the sample-to-cut-off values (S:C ratio) in 57 candidates at donation. Comparing true and false-positive anti-HBc results, the different S:C ratios of them were statistically significant and when less than 2, implying in a false-positive result probability over 80%. A high percent of false-positive results (16.07%) was verified after anti-HBc retesting. HBV immunity was characterized in 49.11%, either by anti-HBs detection in retesting (15.18%), or after a single dose HBV vaccination (33.93%). HBV-DNA was negative in all tested donors. In conclusion, this algorithm was useful to clarify the meaning of isolated anti-HBc in most of our blood donors.