668 resultados para obturator prostheses
Resumo:
Thesis (Ph.D.)--University of Washington, 2016-06
Resumo:
The purpose of this study was to evaluate the incidence of corrosion and fretting in 48 retrieved titanium-6aluminum-4vanadium and/or cobalt-chromium-molybdenum modular total hip prosthesis with respect to alloy material microstructure and design parameters. The results revealed vastly different performance results for the wide array of microstructures examined. Severe corrosion/fretting was seen in 100% of as-cast, 24% of low carbon wrought, 9% of high carbon wrought and 5% of solution heat treated cobalt-chrome. Severe corrosion/fretting was observed in 60% of Ti-6Al-4V components. Design features which allow for fluid entry and stagnation, amplification of contact pressure and/or increased micromotion were also shown to play a role. 75% of prosthesis with high femoral head-trunnion offset exhibited poor performance compared to 15% with a low offset. Large femoral heads (>32mm) did not exhibit poor corrosion or fretting. Implantation time was not sufficient to cause poor performance; 54% of prosthesis with greater than 10 years in-vivo demonstrated none or mild corrosion/fretting.
Resumo:
Loss of limb results in loss of function and a partial loss of freedom. A powered prosthetic device can partially assist an individual with everyday tasks and therefore return some level of independence. Powered upper limb prostheses are often controlled by the user generating surface electromyographic (SEMG) signals. The goal of this thesis is to develop a virtual environment in which a user can control a virtual hand to safely grasp representations of everyday objects using EMG signals from his/her forearm muscles, and experience visual and vibrotactile feedback relevant to the grasping force in the process. This can then be used to train potential wearers of real EMG controlled prostheses, with or without vibrotactile feedback. To test this system an experiment was designed and executed involving ten subjects, twelve objects, and three feedback conditions. The tested feedback conditions were visual, vibrotactile, and both visual and vibrotactile. In each experimental exercise the subject attempted to grasp a virtual object on the screen using the virtual hand controlled by EMG electrodes placed on his/her forearm. Two metrics were used: score, and time to task completion, where score measured grasp dexterity. It was hypothesized that with the introduction of vibrotactile feedback, dexterity, and therefore score, would improve and time to task completion would decrease. Results showed that time to task completion increased, and score did not improve with vibrotactile feedback. Details on the developed system, the experiment, and the results are presented in this thesis.
Resumo:
Objectives: To investigate patients' mobility and satisfaction with their lower-limb prosthetic or orthotic device and related service delivery in Sierra Leone; to compare groups of patients regarding type and level of assistive device, gender, area of residence, income; and to identify factors associated with satisfaction with the assistive device and service. Methods: A total of 139 patients answered questionnaires, including the Quebec User Evaluation of Satisfaction with Assistive Technology questionnaire (QUEST 2.0). Results: Eighty-six percent of assistive devices were in use, but half needed repair. Thirty-three percent of patients reported pain when using their assistive device. Patients had difficulties or could not walk at all on: uneven ground (65%); hills (75%); and stairs (66%). Patients were quite satisfied with their assistive device and the service (mean 3.7 out of 5 in QUEST), but reported 886 problems. Approximately half of the patients could not access services. In relation to mobility and service delivery, women, orthotic patients and patients using above-knee assistive devices had the poorest results. The general condition of the assistive device and patients' ability to walk on uneven ground were associated with satisfaction with the assistive devices and service. Conclusion: Patients reported high levels of mobility while using their device although they experienced pain and difficulties walking on challenging surfaces. Limitations in the effectiveness of assistive devices and limited access to follow-up services and repairs were issues desired to be addressed.
Resumo:
Biotribology, the study of lubrication, wear and friction within the body, has become a topic of high importance in recent times as we continue to encounter debilitating diseases and trauma that destroy function of the joints. A highly successful surgical procedure to replace the joint with an artificial equivalent alleviates dysfunction and pain. However, the wear of the bearing surfaces in prosthetic joints is a significant clinical problem and more patients are surviving longer than the life expectancy of the joint replacement. Revision surgery is associated with increased morbidity and mortality and has a far less successful outcome than primary joint replacement. As such, it is essential to ensure that everything possible is done to limit the rate of revision surgery. Past experience indicates that the survival rate of the implant will be influenced by many parameters, of primary importance, the material properties of the implant, the composition of the synovial fluid and the method of lubrication. In prosthetic joints, effective boundary lubrication is known to take place. The interaction of the boundary lubricant and the bearing material is of utmost importance. The identity of the vital active ingredient within synovial fluid (SF) to which we owe the near frictionless performance of our articulating joints has been the quest of researchers for many years. Once identified, tribo tests can determine what materials and more importantly what surfaces this fraction of SF can function most optimally with. Surface-Active Phospholipids (SAPL) have been implicated as the body’s natural load bearing lubricant. Studies in this thesis are the first to fully characterise the adsorbed SAPL detected on the surface of retrieved prostheses and the first to verify the presence of SAPL on knee prostheses. Rinsings from the bearing surfaces of both hip and knee prostheses removed from revision operations were analysed using High Performance Liquid Chromatography (HPLC) to determine the presence and profile of SAPL. Several common prosthetic materials along with a novel biomaterial were investigated to determine their tribological interaction with various SAPLs. A pin-on-flat tribometer was used to make comparative friction measurements between the various tribo-pairs. A novel material, Pyrolytic Carbon (PyC) was screened as a potential candidate as a load bearing prosthetic material. Friction measurements were also performed on explanted prostheses. SAPL was detected on all retrieved implant bearing surfaces. As a result of the study eight different species of phosphatidylcholines were identified. The relative concentrations of each species were also determined indicating that the unsaturated species are dominant. Initial tribo tests employed a saturated phosphatidylcholine (SPC) and the subsequent tests adopted the addition of the newly identified major constituents of SAPL, unsaturated phosphatidylcholine (USPC), as the test lubricant. All tribo tests showed a dramatic reduction in friction when synthetic SAPL was used as the lubricant under boundary lubrication conditions. Some tribopairs showed more of an affinity to SAPL than others. PyC performed superior to the other prosthetic materials. Friction measurements with explanted prostheses verified the presence and performance of SAPL. SAPL, in particular phosphatidylcholine, plays an essential role in the lubrication of prosthetic joints. Of particular interest was the ability of SAPLs to reduce friction and ultimately wear of the bearing materials. The identification and knowledge of the lubricating constituents of SF is invaluable for not only the future development of artificial joints but also in developing effective cures for several disease processes where lubrication may play a role. The tribological interaction of the various tribo-pairs and SAPL is extremely favourable in the context of reducing friction at the bearing interface. PyC is highly recommended as a future candidate material for use in load bearing prosthetic joints considering its impressive tribological performance.
Resumo:
In this paper, I investigate the (mis)performance of ‘passing’ in the context of bodies with disabilities. The desire to conceal, control or contain a body’s idiosyncrasies can be a deceitful act, complicit with dominant cultural assumptions about the benefits of fitting in. Passing, and the performative tricks, techniques and prostheses that support the ‘lie’ of passing, upholding a social contract in which a closeting-as-cure approach accommodates discomfort with difference. In this paper, I consider moments of non-passing, where people are caught out by mistakes or deliberate misperformances of the daily social drama of ability and disability. I reference the work of disabled artists Bill Shannon, Aaron Williamson and Katherine Araniello, who re-perform their daily personal interactions in the public sphere as a sort of guerilla theatre. Their work brings hidden assumptions about how disabled people should act and interact to the brink of visibility. It challenges passers-by to confront their complicity in these discourses by pressing them to re-perform their own spontaneous reactions to bodies that misperform the ‘lie’ of normalcy.
Resumo:
Background: The objective of routine outpatient assessment of well functioning patients after primary total hip arthroplasty (THA) is to detect asymptomatic failure of prostheses to guide recommendations for early intervention. We have observed that the revision of THAs in asymptomatic patients is highly uncommon. We therefore question the need for routine follow-up of patients after THA. Methods: A prospective analysis of an orthopaedic database identified 158 patients who received 177 revision THAs over a 4 year period. A retrospective chart review was conducted. Patient demographics, primary and revision surgery parameters and follow-up information was recorded and cross referenced with AOA NJRR data. Results: 110 THAs in 104 patients (average age 70.4 (SD 9.8 years). There were 70 (63.6%) total, 13 (11.8%) femoral and 27 (24.5%) acetabular revisions. The indications for revision were aseptic loosening (70%), dislocation (8.2%), peri-prosthetic fracture (7.3%), osteolysis (6.4%) and infection (4.5%). Only 4 (3.6%) were asymptomatic revisions. A mean of 5.3 (SD 5.2 and 1.9 (SD 5.3 follow-up appointments were required before revision in patients with and without symptoms, respectively. The average time from the primary to revision surgery was 11.8 (SD 7.23) years. Conclusions: We conclude that patients with prostheses with excellent long term clinical results as validated by Joint Registries, routine follow-up of asymptomatic THA should be questioned and requires further investigation. Based on the work of this study, the current practice of routine follow-up of asymptomatic THA may be excessively costly and unnecessary and a less resource-intensive review method may be more appropriate.
Resumo:
Contemporary 3D radiotherapy treatment planning relies upon the use of 3D electron density maps derived from computed tomography (CT) scans of patient anatomy, to evaluate the effects of that anatomy on radiation dose distributions. Production of these electron density maps requires that the CT numbers (Hounsfield units) that quantify the attenuation of the x-ray beam by the patient’s anatomy must be reliably converted into electron densities, using a stable calibration relationship. This study investigates the fidelity of electron density assignment in the presence of metallic prostheses and implants.
Resumo:
Background We sought to determine whether or not there are differences in disease progression after radical or nonradical (debulking) surgical procedures for malignant pleural mesothelioma. Methods Over a 49-month period, 132 patients with malignant pleural mesothelioma underwent surgery. Fifty-three underwent extrapleural pneumonectomy and 79 underwent nonradical procedures. Time to evidence of clinical disease progression was recorded, as was the site(s) of that disease. Results One-hundred nineteen patients were evaluable, of which 59% (22 radical; 48 nonradical) had disease progression. Overall 30-day mortality was 8.5% (7.5% radical; 9% nonradical). The median time to overall disease progression was considerably longer after extrapleural pneumonectomy than debulking surgery (319 days vs 197 days, p = 0.019), as was the time to local disease progression (631 days vs 218 days, p = 0.0018). There was no preponderance of earlier stage disease in the radical surgery group. There was a trend toward prolonged survival in those undergoing radical surgery, but no significant difference between the groups (497 days vs 324 days, p = 0.079). In those who had extrapleural pneumonectomy, time-to-disease progression significantly decreased with N2 disease compared with N0/1 involvement (197 days vs 358 days, p = 0.02). Conclusions Extrapleural pneumonectomy may be preferable to debulking surgery in malignant pleural mesothelioma to delay disease progression and give greater control of local disease. Involvement of N2 nodes is associated with accelerated disease progression and is therefore a contraindication to extrapleural pneumonectomy. © 2004 by The Society of Thoracic Surgeons.
Resumo:
Bone-anchored prostheses, relying on implants to attach the prosthesis directly to the residual skeleton, are the ultimate resort for patients with transfemoral amputations (TFA) experiencing severe socket discomfort. The first patient receiving a bone-anchored prosthesis underwent the surgery in 1990 in the Sahlgrenska University Hospital (Sweden). To date, there are two commercially available implants: OPRA (Integrum, Sweden) and ILP (Orthodynamics, Germany). The key to success to this technique is a firm bone-implant bonding, depending on increasing mechanical stress applied daily during load bearing exercises (LBE). The loading data could be analysed through different biomechanical variables. The intra-tester reliability of these exercises will be presented here. Moreover the effect of increase of loading, axes of application of the load and body weight as well as the difference between force and moment variables will be discussed.
Resumo:
Objective To examine personal and social demographics, and rehabilitation discharge outcomes of dysvascular and non-vascular lower limb amputees. Methods In total, 425 lower limb amputation inpatient rehabilitation admissions (335 individuals) from 2005 to 2011 were examined. Admission and discharge descriptive statistics (frequency, percentages) were calculated and compared by aetiology. Results Participants were male (74%), aged 65 years (s.d. 14), born in Australia (72%), had predominantly dysvascular aetiology (80%) and a median length of stay 48 days (interquartile range (IQR): 25–76). Following amputation, 56% received prostheses for mobility, 21% (n = 89) changed residence and 28% (n = 116) required community services. Dysvascular amputees were older (mean 67 years, s.d. 12 vs 54 years, s.d. 16; P < 0.001) and recorded lower functional independence measure – motor scores at admission (z = 3.61, P < 0.001) and discharge (z = 4.52, P < 0.001). More nonvascular amputees worked before amputation (43% vs 11%; P < 0.001), were prescribed a prosthesis by discharge (73% vs 52%; P < 0.001) and had a shorter length of stay (7 days, 95% confidence interval: –3 to 17), although this was not statistically significant. Conclusions Differences exist in social and demographic outcomes between dysvascular and non-vascular lower limb amputees.
Resumo:
This research project evaluated the biomechanical and functional outcomes of patients following total knee replacement measured at 6 and 12 months following surgery. Using more objective measures, patients were examined to determine changes in biomechanical and neuromuscular function during performance of activities of daily living such as walking, stair climbing and turning. Adaptations in joint positioning and performance were identified and progressive improvements were made in some areas of locomotor function. The findings of the study provided important objective information to contribute to the design and evaluation of prostheses, new surgical and rehabilitation procedures and improved recovery of patients.
Resumo:
Individuals with limb amputation fitted with conventional socket-suspended prostheses often experience socket-related discomfort leading to a significant decrease in quality of life. Bone-anchored prostheses are increasingly acknowledged as viable alternative method of attachment of artificial limb. In this case, the prosthesis is attached directly to the residual skeleton through a percutaneous fixation. To date, a few osseointegration fixations are commercially available. Several devices are at different stages of development particularly in Europe and the US. [1-15] Clearly, surgical procedures are currently blooming worldwide. Indeed, Australia and Queensland, in particular, have one of the fastest growing populations. Previous studies involving either screw-type implants or press-fit fixations for bone-anchorage have focused on biomechanics aspects as well as the clinical benefits and safety of the procedure. [16-25] In principle, bone-anchored prostheses should eliminate lifetime expenses associated with sockets and, consequently, potentially alleviate the financial burden of amputation for governmental organizations. Sadly, publications focusing on cost-effectiveness are sparse. In fact, only one study published by Haggstrom et al (2012), reported that “despite significantly fewer visits for prosthetic service the annual mean costs for osseointegrated prostheses were comparable with socket-suspended prostheses”.[26] Consequently, governmental organizations such as Queensland Artificial Limb Services (QALS) are facing a number of challenges while adjusting financial assistance schemes that should be fair and equitable to their clients fitted with bone-anchored prostheses. Clearly, more scientific evidence extracted from governmental databases is needed to further consolidate the analyses of financial burden associated with both methods of attachment (i.e., conventional sockets prostheses, bone-anchored prostheses). The purposes of the presentation will be: 1. To outline methodological avenues to assess the cost-effectiveness of bone-anchored prostheses compared to conventional sockets prostheses, 2. To highlight the potential obstacles and limitations in cost-effectiveness analyses of bone-anchored prostheses, 3. To present preliminary results of a cost-comparison analysis focusing on the comparison of the costs expressed in dollars over QALS funding cycles for both methods of attachment.
Resumo:
Individuals with limb amputation fitted with conventional socket-suspended prostheses often experience socket-related discomfort leading to a significant decrease in quality of life. Bone-anchored prostheses are increasingly acknowledged as viable alternative method of attachment of artificial limb. In this case, the prosthesis is attached directly to the residual skeleton through a percutaneous fixation. To date, a few osseointegration fixations are commercially available. Several devices are at different stages of development particularly in Europe and the US.[1-15] Clearly, surgical procedures are currently blooming worldwide. Indeed, Australia and Queensland in particular have one of the fastest growing populations. Previous studies involving either screw-type implants or press-fit fixations for bone-anchorage have focused on fragmented biomechanics aspects as well as the clinical benefits and safety of the procedure. [16-25] However, very few publications have synthetized this information and provided an overview of the current developments in bone-anchored prostheses worldwide, let alone in Australia. The purposes of the presentation will be: 1. To provide an overview of the state-of-art developments in bone-anchored prostheses with as strong emphasis on the design of fixations, treatment, benefits, risks as well as future opportunities and challenges, 2. To present the current international developments of procedures for bone-anchored prostheses in terms of numbers of centers, number of cases and typical case-mix, 3. To highlight the current role Australia is playing as a leader worldwide in terms of growing population, broadest range of case-mix, choices of fixations, development of reimbursement schemes, unique clinical outcome registry for evidence-based practice, cutting-edge research, consumer demand and general public interest.
Resumo:
Bone-anchored prostheses are increasingly acknowledged as viable alternative method of attachment of artificial limb compared to socket-suspended prostheses. To date, a few osseointegration fixations are commercially available. Several devices are at different stages of development particularly in Europe and the US. Clearly, the current momentum experienced worldwide is creating a need for a standardized evaluation framework to assess the benefits and safety of each procedure.