950 resultados para nonpoint-source pollution control
Resumo:
The term ‘water pollution’ broadly refers to the contamination of water and water bodies (e.g. lakes, rivers, oceans, groundwater etc). Water pollution occurs when pollutants are discharged directly or indirectly into water bodies without adequate treatment to remove the harmful contaminants. This affects not only the plants and organisms living in these bodies of water but also the entire natural biological communities and the biodiversity.Advanced Oxidation Processes (AOPs) have been tested as environment-friendly techniques for the treatment of contaminated water, in view of their ability to convert pollutants into harmless end products. These techniques refer to a set of treatment procedures designed to remove organic or inorganic contaminants in wastewater by oxidation. The contaminants are oxidized by different reagents such as air, oxygen, ozone, and hydrogen peroxide which are introduced in precise, preprogrammed dosages, sequences and combinations under appropriate conditions. The procedure when combined with light in presence of catalyst is known as photocatalysis. When ultrasound (US) is used as the energy source, the process is referred as sonication. Sonication in presence of catalyst is referred as sonocatalysis. Of late, combination of light and sound as energy sources has been tested for the decontamination of wastewater in the presence of suitable catalyst. In this case, the process is referred as sonophotocatalysis. These AOPs are specially advantageous in pollution control and waste water treatment because unlike many other technologies, they do not just transfer the pollutant from one phase to another but completely degrade them into innocuous substances such as CO2 and H2O.
Resumo:
En aquest estudi, la toxicitat de diversos metalls pesants i l'arsènic va ser analitzada utilitzant diferents models biològics. En la primera part d'aquest treball, el bioassaig de toxicitat Microtox, el qual està basat en la variació de l'emissió lumínica del bacteri luminiscent Vibrio fischeri, va ser utilitzat per establir les corbes dosi-resposta de diferents elements tòxics com el Zn(II), Pb(II), Cu(II), Hg(II), Ag(I), Co(II), Cd(II), Cr(VI), As(V) i As(III) en solucions aquoses. Els experiments es varen portar a terme a pH 6.0 i 7.0 per tal de mostrar que el pH pot influir en la toxicitat final mesurada d'alguns metalls degut als canvis relacionats amb la seva especiació química. Es varen trobar diferents tipus de corbes dosi-resposta depenent del metall analitzat i el pH del medi. En el cas de l'arsènic, l'efecte del pH en la toxicitat de l'arsenat i l'arsenit es va investigar utilitzant l'assaig Microtox en un rang de pHs comprès entre pH 5.0 i 9.0. Els valors d'EC50 determinats per l'As(V) disminueixen, reflectint un augment de la toxicitat, a mesura que el pH de la solució augmenta mentre que, en el cas de l'As(III), els valors d'EC50 quasi bé no varien entre pH 6.0 i 8.0 i només disminueixen a pH 9.0. HAsO42- i H2AsO3- es varen definir com les espècies més tòxiques. Així mateix, una anàlisi estadística va revelar un efecte antagònic entre les espècies químiques d'arsenat que es troben conjuntament a pH 6.0 i 7.0. D'altra banda, els resultats de dos mètodes estadístics per predir la toxicitat i les possibles interaccions entre el Co(II), Cd(II), Cu(II), Zn(II) i Pb(II) en mescles binàries equitòxiques es varen comparar amb la toxicitat observada sobre el bacteri Vibrio fischeri. L'efecte combinat d'aquests metalls va resultar ser antagònic per les mescles de Co(II)-Cd(II), Cd(II)-Zn(II), Cd(II)-Pb(II) i Cu(II)-Pb(II), sinèrgic per Co(II)-Cu(II) i Zn(II)-Pb(II) i additiu en els altres casos, revelant un patró complex de possibles interaccions. L'efecte sinèrgic de la combinació Co(II)-Cu(II) i la forta disminució de la toxicitat del Pb(II) quan es troba en presència de Cd(II) hauria de merèixer més atenció quan s'estableixen les normatives de seguretat ambiental. La sensibilitat de l'assaig Microtox també va ser determinada. Els valors d'EC20, els quals representen la toxicitat llindar mesurable, varen ser determinats per cada element individualment i es va veure que augmenten de la següent manera: Pb(II) < Ag(I) < Hg(II) Cu(II) < Zn(II) < As(V) < Cd(II) Co(II) < As(III) < Cr(VI). Aquests valors es varen comparar amb les concentracions permeses en aigues residuals industrials establertes per la normativa oficial de Catalunya (Espanya). L'assaig Microtox va resultar ser suficientment sensible per detectar els elements assajats respecte a les normes oficials referents al control de la contaminació, excepte en el cas del cadmi, mercuri, arsenat, arsenit i cromat. En la segona part d'aquest treball, com a resultats complementaris dels resultats previs obtinguts utilitzant l'assaig de toxicitat aguda Microtox, els efectes crònics del Cd(II), Cr(VI) i As(V) es varen analitzar sobre la taxa de creixement i la viabilitat en el mateix model biològic. Sorprenentment, aquests productes químics nocius varen resultar ser poc tòxics per aquest bacteri quan es mesura el seu efecte després de temps d'exposició llargs. Tot i això, en el cas del Cr(VI), l'assaig d'inhibició de la viabilitat va resultar ser més sensible que l'assaig de toxicitat aguda Microtox. Així mateix, també va ser possible observar un clar fenomen d'hormesis, especialment en el cas del Cd(II), quan s'utilitza l'assaig d'inhibició de la viabilitat. A més a més, diversos experiments es varen portar a terme per intentar explicar la manca de toxicitat de Cr(VI) mostrada pel bacteri Vibrio fischeri. La resistència mostrada per aquest bacteri podria ser atribuïda a la capacitat d'aquest bacteri de convertir el Cr(VI) a la forma menys tòxica de Cr(III). Es va trobar que aquesta capacitat de reducció depèn de la composició del medi de cultiu, de la concentració inicial de Cr(VI), del temps d'incubació i de la presència d'una font de carboni. En la tercera part d'aquest treball, la línia cel·lular humana HT29 i cultius primaris de cèl·lules sanguínies de Sparus sarba es varen utilitzar in vitro per detectar la toxicitat llindar de metalls mesurant la sobreexpressió de proteines d'estrès. Extractes de fangs precedents de diverses plantes de tractament d'aigues residuals i diferents metalls, individualment o en combinació, es varen analitzar sobre cultius cel·lulars humans per avaluar el seu efecte sobre la taxa de creixement i la capacitat d'induir la síntesi de les proteïnes Hsp72 relacionades amb l'estrès cel·lular. No es varen trobar efectes adversos significatius quan els components s'analitzen individualment. Nogensmenys, quan es troben conjuntament, es produeix un afecte advers sobre tan la taxa de creixement com en l'expressió de proteins d'estrès. D'altra banda, cèl·lules sanguínies procedents de Sparus sarba es varen exposar in vitro a diferents concentracions de cadmi, plom i crom. La proteïna d'estrès HSP70 es va sobreexpressar significativament després de l'exposició a concentracions tan febles com 0.1 M. Sota les nostres condicions de treball, no es va evidenciar una sobreexpressió de metal·lotioneïnes. Nogensmenys, les cèl·lules sanguínies de peix varen resultar ser un model biològic interessant per a ser utilitzat en anàlisis de toxicitat. Ambdós models biològics varen resultar ser molt adequats per a detectar acuradament la toxicitat produïda per metalls. En general, l'avaluació de la toxicitat basada en l'anàlisi de la sobreexpressió de proteïnes d'estrès és més sensible que l'avaluació de la toxicitat realitzada a nivell d'organisme. A partir dels resultats obtinguts, podem concloure que una bateria de bioassaigs és realment necessària per avaluar acuradament la toxicitat de metalls ja que existeixen grans variacions entre els valors de toxicitat obtinguts emprant diferents organismes i molts factors ambientals poden influir i modificar els resultats obtinguts.
Resumo:
The introduction of the EU Water Framework Directive requires policy to address non-point source pollution as part of an overall integrated strategy to improve the ecological status of water bodies. In this paper, we combine an economic optimisation framework with a dynamic simulation model of N transport in the Kennet Catchment to link decisions taken at the farm level to reductions in nitrate concentrations in the River Kennet. We examine a variety of policies targeted at reducing fertiliser use and changing the way in which farm land is used. We find that a tax on nitrogen emerges as the best policy both in terms of cost- and environmental effectiveness. Such a policy involves a considerable reduction in fertiliser use, as well as, a restructuring of land-use away from arable towards increased use of set-aside. Budgetary implications of such a radical move towards set-aside would be huge and hence unlikely to be politically palatable given the objective of reducing the EU budgetary allocation to agriculture. Additionally, the current rise in world demand for food may also mitigate calls for increasing the proportion of land taken out of agricultural production. Although the study succeeds in establishing a link between actions on the farm and nitrate concentrations in the stream water, further work is required to explore the effect of the retention of nitrates in the unsaturated zone and groundwater on this link.
Resumo:
This paper introduces PSOPT, an open source optimal control solver written in C++. PSOPT uses pseudospectral and local discretizations, sparse nonlinear programming, automatic differentiation, and it incorporates automatic scaling and mesh refinement facilities. The software is able to solve complex optimal control problems including multiple phases, delayed differential equations, nonlinear path constraints, interior point constraints, integral constraints, and free initial and/or final times. The software does not require any non-free platform to run, not even the operating system, as it is able to run under Linux. Additionally, the software generates plots as well as LATEX code so that its results can easily be included in publications. An illustrative example is provided.
Resumo:
Diffuse pollution, and the contribution from agriculture in particular, has become increasingly important as pollution from point sources has been addressed by wastewater treatment. Land management approaches, such as construction of field wetlands, provide one group of mitigation options available to farmers. Although field wetlands are widely used for diffuse pollution control in temperate environments worldwide, there is a shortage of evidence for the effectiveness and viability of these mitigation options in the UK. The Mitigation Options for Phosphorus and Sediment Project aims to make recommendations regarding the design and effectiveness of field wetlands for diffuse pollution control in UK landscapes. Ten wetlands have been built on four farms in Cumbria and Leicestershire. This paper focuses on sediment retention within the wetlands, estimated from annual sediment surveys in the first two years, and discusses establishment costs. It is clear that the wetlands are effective in trapping a substantial amount of sediment. Estimates of annual sediment retention suggest higher trapping rates at sandy sites (0.5–6 t ha�1 yr�1), compared to silty sites (0.02–0.4 t ha�1 yr�1) and clay sites (0.01–0.07 t ha�1 yr�1). Establishment costs for the wetlands ranged from £280 to £3100 and depended more on site specific factors, such as fencing and gateways on livestock farms, rather than on wetland size or design. Wetlands with lower trapping rates would also have lower maintenance costs, as dredging would be required less frequently. The results indicate that field wetlands show promise for inclusion in agri-environment schemes, particularly if capital payments can be provided for establishment, to encourage uptake of these multi-functional features.
Resumo:
Until recently, pollution control in rural drainage basins of the UK consisted solely of water treatment at the point of abstraction. However, prevention of agricultural pollution at source is now a realistic option given the possibility of financing the necessary changes in land use through modification of the Common Agricultural Policy. This paper uses a nutrient export coefficient model to examine the cost of land-use change in relation to improvement of water quality. Catchment-wide schemes and local protection measures are considered. Modelling results underline the need for integrated management of entire drainage basins. A wide range of benefits may accrue from land-use change, including enhanced habitats for wildlife as well as better drinking water.
Resumo:
A manageable, relatively inexpensive model was constructed to predict the loss of nitrogen and phosphorus from a complex catchment to its drainage system. The model used an export coefficient approach, calculating the total nitrogen (N) and total phosphorus (P) load delivered annually to a water body as the sum of the individual loads exported from each nutrient source in its catchment. The export coefficient modelling approach permits scaling up from plot-scale experiments to the catchment scale, allowing application of findings from field experimental studies at a suitable scale for catchment management. The catchment of the River Windrush, a tributary of the River Thames, UK, was selected as the initial study site. The Windrush model predicted nitrogen and phosphorus loading within 2% of observed total nitrogen load and 0.5% of observed total phosphorus load in 1989. The export coefficient modelling approach was then validated by application in a second research basin, the catchment of Slapton Ley, south Devon, which has markedly different catchment hydrology and land use. The Slapton model was calibrated within 2% of observed total nitrogen load and 2.5% of observed total phosphorus load in 1986. Both models proved sensitive to the impact of temporal changes in land use and management on water quality in both catchments, and were therefore used to evaluate the potential impact of proposed pollution control strategies on the nutrient loading delivered to the River Windrush and Slapton Ley
Resumo:
Soil and subsoil pollution is not only significant in terms of environmental loss, but also a matter of environmental and public health. Solid, liquid and gaseous residues are the major soil contamination agents. They originate from urban conglomerates and industrial areas in which it is impossible to emphasize the chemical, petrochemical and textile industry; thermoelectric, mining, and ironmaster activities. The contamination process can thus be defined as a compound addition to soil, from what qualitative and or quantitative manners can modify soil's natural characteristics and use, producing baneful and deteriorative effects on human health. Studies have shown that human exposition to high concentration of some heavy metals found on soil can cause serious health problems, such as pulmonary or kidney complications, liver and nervous system harm, allergy, and the chronic exposition that leads to death. The present study searches for the correlation among soil contamination, done through a geochemical baseline survey of an industrial contamination area on the shoreline of Sao Paulo state. The study will be conducted by spatial analysis using Geographical Information Systems for mapping and regression analysis. The used data are 123 soil samples of percentage concentration of heavy metals. They were sampled and spatially distributed by geostatistics methods. To verify if there is a relation between heavy metals soil pollution and morbidity an executed correlation and regression analysis will be done using the pollution registers as the independent variables and morbidity as dependable variables. It is expected, by the end of the study, to identify the areas relation between heavy metals soil pollution and morbidity, moreover to be able to provide assistance in terms of new methodologies that could facilitate soil pollution control programs and public health planning. © 2010 WIT Press.
Resumo:
Includes bibliography
Resumo:
Includes bibliography
Resumo:
Voltage source inverters use large electrolytic capacitors in order to decouple the energy between the utility and the load, keeping the DC link voltage constant. Decreasing the capacitance reduces the distortion in the inverter input current but this also affects the load with low-order harmonics and generate disturbances at the input voltage. This paper applies the P+RES controller to solve the challenge of regulating the output current by means of controlling the magnitude of the current space vector, keeping it constant thus rejecting harmonic disturbances that would otherwise propagate to the load. This work presents a discussion of the switching and control strategy. © 2011 IEEE.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
1