942 resultados para multimode sample introduction system


Relevância:

30.00% 30.00%

Publicador:

Resumo:

Background: A survey of pathology reporting of breast cancer in Western Australia in 1989 highlighted the need for improvement. The current study documents (1) changes in pathology reporting from 1989 to 1999 and (2) changes in patterns of histopathological prognostic indicators for breast cancer following introduction of mammographic screening in 1989. Methods: Data concerning all breast cancer cases reported in Western Australia in 1989, 1994 and 1999 were retrieved using the State Cancer Registry, Hospital Morbidity data system, and pathology laboratory records. Results: Pathology reports improved in quality during the decade surveyed. For invasive carcinoma, tumour size was not recorded in 1.2% of pathology reports in 1999 compared with 16.1% in 1989 (rho<0.001). Corresponding figures for other prognostic factors were: tumour grade 3.3% and 51.6% (rho<0.001), tumour type 0.2% and 4.1% (rho<0.001), vascular invasion 3.7% and 70.9% (rho<0.001), and lymph node status 1.9% and 4.5% (rho=0.023). In 1999, 5.9% of reports were not in a synoptic/checklist format, whereas all reports were descriptive in 1989 (rho<0.001). For the population as a whole, the proportion of invasive carcinomas <1 cm was 20.9% in 1999 compared with 14.5% in 1989 (rho<0.001); for tumours <2 cm the corresponding figures were 65.4% and 59.7% (rho=0.013). In 1999, 30.5% of tumours were histologically well-differentiated compared with 10.6% in 1989 (rho<0.001), and 61.7% were lymph node negative in 1999 compared with 57.1% in 1989 (rho=0.006). Pure ductal carcinoma in situ (DCIS) constituted 10.9% and 7.9% of total cases of breast carcinoma in 1999 and 1989, respectively (rho=0.01). Conclusions: Quality of pathology reporting improved markedly over the period, in parallel with adoption of stanclardised synoptic pathology reports. By 1999, recording of important prognostic information was almost complete. Frequency of favourable prognostic factors generally increased over time, reflecting expected effects of mammographic screening.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The St. Lawrence Island polynya (SLIP) is a commonly occurring winter phenomenon in the Bering Sea, in which dense saline water produced during new ice formation is thought to flow northward through the Bering Strait to help maintain the Arctic Ocean halocline. Winter darkness and inclement weather conditions have made continuous in situ and remote observation of this polynya difficult. However, imagery acquired from the European Space Agency ERS-1 Synthetic Aperture Radar (SAR) has allowed observation of the St. Lawrence Island polynya using both the imagery and derived ice displacement products. With the development of ARCSyM, a high resolution regional model of the Arctic atmosphere/sea ice system, simulation of the SLIP in a climate model is now possible. Intercomparisons between remotely sensed products and simulations can lead to additional insight into the SLIP formation process. Low resolution SAR, SSM/I and AVHRR infrared imagery for the St. Lawrence Island region are compared with the results of a model simulation for the period of 24-27 February 1992. The imagery illustrates a polynya event (polynya opening). With the northerly winds strong and consistent over several days, the coupled model captures the SLIP event with moderate accuracy. However, the introduction of a stability dependent atmosphere-ice drag coefficient, which allows feedbacks between atmospheric stability, open water, and air-ice drag, produces a more accurate simulation of the SLIP in comparison to satellite imagery. Model experiments show that the polynya event is forced primarily by changes in atmospheric circulation followed by persistent favorable conditions: ocean surface currents are found to have a small but positive impact on the simulation which is enhanced when wind forcing is weak or variable.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Introduction: The mechanisms by which severe cholestatic hepatitis develops after liver transplantation are not fully understood. Reports on immunohistochemical distribution of hepatitis C virus (HCV) antigens are still scarce, but recently, HCV immunostaining was suggested for early diagnosis of cholestatic forms of recurrent hepatitis C in liver grafts. After purification, Rb246 pab anticore (aa1-68) yielded specific, granular cytoplasmic staining in hepatocytes. Signal amplification through the Envision-Alkaline Phosphatase System avoided endogenous biotin and peroxidase. Aims/Methods: Rb246 was applied to liver samples of explants of 12 transplant recipients, six with the most severe form of post-transplantation recurrence, severe cholestatic hepatitis (group 1) and six with mild recurrence (group 2). We also assessed immuno-reactivity at two time-points post-transplantation (median 4 and 22 months) in both groups. HCV-core Ag was semiquantified from 0 to 3+ in each time point. Serum HCV-RNA was also measured on the different time points by branched DNA. Results: In the early post-transplant time point, one patient had a mild staining (1+), two patients had a moderate staining (2+) and the other three had no staining in group 1, compared with five patients with no staining (0) and one patient with mild staining (1+) in group 2. Late post-transplant liver samples were available in nine patients, and two out of four samples in group 1 showed a mild staining, compared with no staining patients in five patients in group 2. Strikingly, on the explant samples, HCV immunostaining was strongly positive in group 1, and mildly positive in group 2. Two out of five samples showed 3+ staining, and three samples showed 2+ staining in group 1; two out of five samples showed no staining, two samples showed 1+ staining and one sample showed 2+ staining in group 2. Serum HCV-RNA was significantly higher in group 1, on both time-points post-transplantation. HCV-core Ag was not directly associated with serum HCV-RNA on the different time points. Conclusion: These preliminary results suggest that strong HCV immunostaining in the explant is predictive of more severe disease recurrence.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Introduction. This study addressed the role of the local renin-angiotensin system (RAS) in the left ventriular hypertropy (LVH) induced by swimming training using pharmacological blockade. Materials and methods. Female Wistar rats treated with enalapril maleate (60 mg.kg(-1).d(-1), n = 38), losartan (20 mg.kg(-1).d(-1), n = 36) or high salt diet (1% NaCl, n = 38) were trained by two protocols (T1: 60-min swimming session, 5 days per week for 10 weeks and T2: the same T1 protocol until the 8(th) week, then 9(th) week they trained twice a day and 10(th) week they trained three times a day). Salt loading prevented activation of the systemic RAS. Haemodynamic parameters, soleus citrate synthase (SCS) activity and LVH (left ventricular/body weight ratio, mg/g) were evaluated. Results. Resting heart rate decreased in all trained groups. SCS activity increased 41% and 106% in T1 and T2 groups, respectively. LVH was 20% and 30% in T1 and T2 groups, respectively. Enalapril prevented 39% of the LVH in T2 group (p < 0.05). Losartan prevented 41% in T1 and 50% in T2 (P < 0.05) of the LVH in trained groups. Plasma renin activity (PRA) was inhibited in all salt groups and it was increased in T2 group. Conclusions. These data provide evidence that the physiological LVH induced by swimming training is regulated by local RAS independent from the systemic, because the hypertrophic response was maintained even when PRA was inhibited by chronic salt loading. However, other systems can contribute to this process.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Introduction. Lung transplantation has become the mainstay therapy for patients with end-stage lung disease refractory to medical management. However, the number of patients listed for lung transplantation largely exceeds available donors. The study of lung preservation requires accurate, cost-effective small animal models. We have described a model of ex vivo rat lung perfusion using a commercially available system. Methods. Male Wistar rats weighing 250 g-300 g were anesthetized with intraperitoneal sodium thiopental (50 mg/kg body weight). The surgical technique included heart-lung block extraction, assembly, and preparation for perfusion and data collection. We used an IL-2 Isolated Perfused Rat or Guinea Pig Lung System (Harvard Apparatus, Holliston, Mass, United States; Hugo Sachs Elektronik, Alemanha). Results. Preliminary results included hemodynamic and pulmonary mechanics data gathered in the experiments. Conclusion. The isolated rat lung perfusion system is a reliable method to assess lung preservation.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Introduction: The photoelasticity is used for assessing the tensions/deformations involved in photoelastic materials when submitted to a given load by the observation of optical effects. The screw performance and mechanical functions are directly associated to the quality of the screws fixation in the vertebrae. Photoelasticity is an important tool to perform comparative studies of this nature. Objective: The aim of this study was to compare, by using photoelasticity, internal stresses produced by the screw with an external diameter of 6 mm, when submitted to two different pullout strengths. Materials and Methods: For this, four photoelastic models were produced. The simulation was conducted by using two pullout strengths: 0.75 and 1.50 kgf. The maximum shear stresses were calculated on 19 points around the screws, using the Tardy compensation method. Results:The values of maximum shear stress were higher with the load of 1.50 kgf. Conclusion: Thus, the screw will be more susceptible to pullout when heavier loads are applied. According to our analysis, we also found that the site with the highest maximum shear stress was found to be at the peak of creast, particularly near the tips of the screws, regardless of the load employed.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Introduction: Among patients with congestive heart failure (CHF) both obstructive and central sleep apnea (SA) are associated with increased sympathetic activity. However, the day-night pattern of cardiac autonomic nervous system modulation in CHF patients with and without sleep apnea is unknown. Material and methods: Twenty-five CHF patients underwent polysomnography with simultaneous beat-to-beat blood pressure (Portapres), respiration and electrocardiogram monitoring. Patients were divided according to the presence (SA, n=17) and absence of SA (NoSA, n=8). Power spectral analyses of heart rate variability (HRV) and spontaneous baroreflex sensitivity (BRS) were determined in periods with stable breathing while awake at 6 AM, 10 AM, 10 PM, as well as during stage 2 sleep. In addition, muscle sympathetic nerve activity (MSNA) was evaluated at 10 AM. Results: RR variance, low-frequency (LF), high-frequency (HF) powers of HRV, and BRS were significantly lower in patients with SA compared with NoSA in all periods. HF power, a marker of vagal activity, increased during sleep in patients with NoSA but in contrast did not change across the 24-hour period in patients with SA. MSNA was significantly higher in patients with SA compared with NoSA. RR variance, LF and HF powers correlated inversely with simultaneous MSNA (r=-0.64, -0.61, and -0.61 respectively; P < 0.01). Conclusions: Patients with CHF and SA present a reduced and blunted cardiac autonomic modulation across the 24-hour period. These findings may help to explain the increased cardiovascular risk in patients with CHF and SA. (C) 2009 Elsevier Ireland Ltd. All rights reserved.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Introduction: Bruxism is characterized by repeated tooth grinding or clenching. The condition can occur in all age ranges and in both genders, being related or not to other oral habits. Objective: The objective of the present study was to investigate the occurrence of bruxism in children with nasal obstruction and to determine its association with other factors. Methods: Sixty children with nasal obstruction seen at the Otorhinolaryngology Outpatient Clinic of the University Hospital. of Ribeirao Preto participated in the study. The data were obtained using a pre-established questionnaire applied to the person responsible and by orofacial evaluation of the patient. The participants were divided into two groups: group with bruxism (GB) as reported by the relatives and with the presence of tooth wear detected by clinical evaluation, and group without bruxism (GWB), consisting of children with none of the two symptoms of bruxism mentioned above. Results: The presence of bruxism exceeded its absence in the sample studied (65.22%). There was no significant difference (P < 0.05) between groups regarding gender, phase of dentition, presence of hearing diseases, degree of malocclusion, or child behavior. Conclusion: Bruxism and deleterious oral habits such as biting behavior (objects, tips and nails) were significantly present, together with the absence of suction habits, in the children with nasal obstruction. (c) 2007 Elsevier Iretand Ltd. All. rights reserved.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Introduction: The purpose of this study was to evaluate the biocompatibility of the root canal filling system Epiphany/Resilon in connective tissue of rats. Methods: Fifteen rats were used, separated into 3 groups in accordance with its period of death (7, 21, 42 days). Four filled dentin tubes were implanted with the tested materials as follows: ERSP group, Epiphany/Resilon with Self-etch Primer; ER group, Epiphany/Resilon without primer; EG group, Endofill/gutta-percha points; and ET group, empty tube. After 7, 21, and 42 days, animals were killed, obtaining 5 samples per group. A grade from I-IV was used to graduate the inflammatory reaction. Results: Results showed that Epiphany/Resilon (ERSP and ER groups) induced a slight (II) inflammatory reaction after 42 days. However, in ER group, in which the self-etch primer was not applied, severe (IV) to moderate (III) inflammatory reactions were observed between 7 and 21 days. When compared with the EG and ET groups, it was observed that these groups presented tissue reaction ranging from slight (II, 7 and 21 days) to no inflammation (I, 42 days). Conclusions: Epiphany/Resilon root canal filling system presented satisfactory tissue reaction. It was biocompatible when tested in connective tissue of rats. (J Endod 2010;36:110-114)

Relevância:

30.00% 30.00%

Publicador:

Resumo:

In order to investigate the genetic and environmental antecedents of osteoarthritis (CA), self-report measures of joint pain, stiffness and swelling were obtained from a population-based sample of 1242 twin pairs over 50 years of age. In order to provide validation for these self-report measures, a subsample of 118 twin pairs were examined according to the American College of Rheumatology clinical and radiographic criteria for the classification of osteoarthritis. A variety of statistical methods were employed to identify the model derived from self-report variables which would provide optimal prediction of these standardised assessments, and structural equation modelling was used to determine the relative influences of genetic and environmental influences on the development of osteoarthritis. Significant genetic effects were found to contribute to osteoarthritis of the hands, hips and knees in women, with heritability estimates ranging from 30-46% depending on the site. In addition, the additive genetic effects contributing to osteoarthritis in various parts of the body were confirmed to be the same. Statistically significant familial aggregation of osteoarthritis in men was also observed, but it was not possible to determine whether this was due to genetic or shared environmental effects.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Objectives: The aim was to determine whether methadone maintenance treatment reduced heroin use, syringe sharing and HIV or hepatitis C incidence among prisoners. Methods: All eligible prisoners seeking drug treatment were randomised to methadone or a waitlist control group from 1997 to 1998 and followed up after 4 months. Heroin use was measured by hair analysis and self report; drugs used and injected and syringe sharing were measured by self report. Hepatitis C and HIV incidence was measured by serology. Results: Of 593 eligible prisoners, 382 (64%) were randomised to MMT (n = 191) or control (n = 191). 129 treated and 124 control subjects were followed up at 5 months. Heroin use was significantly lower among treated than control subjects at follow up. Treated subjects reported lower levels of drug injection and syringe sharing at follow up. There was no difference in HIV or hepatitis C incidence. Conclusions: Consideration should be given to the introduction of prison methadone programs particular where community based programs exist. (C) 2003 Elsevier Ireland Ltd. All rights reserved.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Objective: To develop a 'quality use of medicines' coding system for the assessment of pharmacists' medication reviews and to apply it to an appropriate cohort. Method: A 'quality use of medicines' coding system was developed based on findings in the literature. These codes were then applied to 216 (111 intervention, 105 control) veterans' medication profiles by an independent clinical pharmacist who was supported by a clinical pharmacologist with the aim to assess the appropriateness of pharmacy interventions. The profiles were provided for veterans participating in a randomised, controlled trial in private hospitals evaluating the effect of medication review and discharge counselling. The reliability of the coding was tested by two independent clinical pharmacists in a random sample of 23 veterans from the study population. Main outcome measure: Interrater reliability was assessed by applying Cohen's kappa score on aggregated codes. Results: The coding system based on the literature consisted of 19 codes. The results from the three clinical pharmacists suggested that the original coding system had two major problems: (a) a lack of discrimination for certain recommendations e. g. adverse drug reactions, toxicity and mortality may be seen as variations in degree of a single effect and (b) certain codes e. g. essential therapy were in low prevalence. The interrater reliability for an aggregation of all codes into positive, negative and clinically non-significant codes ranged from 0.49-0.58 (good to fair). The interrater reliability increased to 0.72-0.79 (excellent) when all negative codes were excluded. Analysis of the sample of 216 profiles showed that the most prevalent recommendations from the clinical pharmacists were a positive impact in reducing adverse responses (31.9%), an improvement in good clinical pharmacy practice (25.5%) and a positive impact in reducing drug toxicity (11.1%). Most medications were assigned the clinically non-significant code (96.6%). In fact, the interventions led to a statistically significant difference in pharmacist recommendations in the categories; adverse response, toxicity and good clinical pharmacy practice measured by the quality use of medicine coding system. Conclusion: It was possible to use the quality use of medicine coding system to rate the quality and potential health impact of pharmacists' medication reviews, and the system did pick up differences between intervention and control patients. The interrater reliability for the summarised coding system was fair, but a larger sample of medication regimens is needed to assess the non-summarised quality use of medicines coding system.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The purpose of this study is to characterize how Portuguese Small and Medium Enterprises (SMEs) view the Occupational Health and Safety Management Systems (OHSMSs) certification process, after receiving the Quality Management System (QMS) certification. References were based on the ISO 9001 standard for a QMS and OHSAS 18001 for OHSMS. The method used to evaluate the implemented systems, was by form of questionnaire. Those questioned had to have a certified quality management system, an implemented OHSMS and be a SME. The questionnaire was sent to 300 SMEs; 46 responses were received and validated. Of them, only 12 SMEs had the OHSMS certificate according to OHSAS 18001. Within those 12 companies that participated: 7 SMEs are from the industrial sector; 3 belong to the electricity/telecommunications sector and 2 SMEs are from the trade/services activity sector. The size of the sample was small, but corresponds to Portuguese reality. Moreover, 34 SMEs did not have the OHSMS certificate. The questionnaire requested the main reasons for SMEs to opt for non-certification and it was related with high costs, while the main reasons to certificate were, among others, needed to eliminate or minimize risks to workers. The main benefits that Portuguese SMEs have gained from the referred certifications have been, improved working conditions, ensuring compliance with legislation and better internal communication about risks and hazards. Also presented are the main difficulties in achieving an OHSMS certification including high certification costs, difficulties motivating personnel, difficulties in changing the company’s culture and increased bureaucracy.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

In medical emergency situations, when a patient needs a blood transfusion, the universal blood type O− is administered. This procedure may lead to the depletion of stock reserves of O− blood. Nowadays, there is no commercial equipment capable of determining the patient's blood type in situ, in a fast and reliable process. Human blood typing is usually performed through the manual test, which involves a macroscopic observation and interpretation of the results by an analyst. This test, despite of having a fast response time, may lead to human errors, which sometimes can be fatal to the patient. This paper presents the development of an automatic mechatronic prototype for determining human blood typing (ABO and Rh systems) through image processing techniques. The prototype design takes into account the characteristics of reliability of analysis, portability, and response time allowing the system to be used in emergency situations. The developed prototype performs blood and reagents mixture acquires the resultant image and processes the data (based on image processing techniques) to determine the sample blood type. It was tested in a laboratory, using cataloged samples of blood types, provided by the Portuguese Institute of Blood and Transplantation. Hereafter, it is expected to test and validate the prototype in clinical environments.