900 resultados para modified kaolins
Resumo:
In this study, the behaviour of two structural adhesives modified with thermally expandable particles (TEPs) was investigated as a preliminary study for further investigations on the potential of TEPs in adhesive joints. Tensile bulk tests were performed to get the tensile properties of the adhesives and TEPs-modified adhesives. In order to determine the expansion temperature of the particles while encapsulated in these particular adhesive systems, the variation of the volume of adhesive samples modified with different TEPs concentration as a function of temperature was measured. Further, the possibility of any chemical interactions between TEPs and adhesives matrix in the TEPs-modified specimens was verified by a Fourier transform infrared spectroscopy analysis. Finally, the fracture surfaces of the unmodified and TEPs-modified specimens, as well as the dispersion and the morphology of the particles, were examined by a scanning electron microscopy analysis. It was found that the stiffness of the TEPs-modified adhesives is not affected by incorporation of TEPs in the adhesives matrix, while the tensile yield strength decreased by increasing the wt% TEPs content. In applications of such particular materials (TEPs-modified adhesives), the temperature should be controlled to stay between 90°C and 120°C in order to obtain the highest expansion ratio. At a lower temperature, not all the particles will expand, and above, the TEPs will deteriorate and as a result the TEPs-modified adhesives will deteriorate.
Resumo:
Thermally expandable particles (TEPs) were developed by Dow Chemical Co in the early 1970´s [1] and were further developed by others [2, 3]. They are particles made up of a thermoplastic shell filled with liquid hydrocarbon. On heating them, two transformations will occur. One is the softening of shell material and the other is the gasification of the hydrocarbon liquid inside it. As a consequence, the shell will expand as the gas inside it will push the softened shell from inside out causing it to grow in size [4]. When fully expanded, the growth in volume of the particle can be from 50 to 100 times [3]. Owing to this unique behaviour, TEPs are used by the industry in a wide variety of applications mainly for weight reduction and appearance improvement for thermoplastics, inks, and coatings. In adhesive bonding, TEPs have been used for recycling purposes. Moreover, TEPs might be used to modify structural adhesives for other new purposes, such as: to increase the joint strength by creating an adhesive functionally modified along the overlap of the joint by gradual heating and/or to heal the adhesive in case of damage.
Resumo:
To turn wood into a construction material with enhanced properties, many methods of chemical modification have been developed in the last few decades. In this work, mechanical properties of pine wood were chemically modified, compared and evaluated. Maritime pine wood (Pinus pinaster) was modified with four chemical processes: 1,3-dimethylol-4,5- dihydroxyethyleneurea, N-methylol melamine formaldehyde, tetra-alkoxysilane and wax. The following mechanical properties were assessed experimentally: Modulus of elasticity measured statically, stiffness stabilization efficiency in different climates (30 and 87% of relative humidity), modulus of rupture, work maximum load, impact bending strength, compression, tensile and shear strength at indoor conditions (65% of relative humidity). In both types of active principle of modification, cell wall or lumen fill, no significant changes on the bending stiffness (modulus of elasticity) were found. In the remaining properties analysed significant changes in the modified wood-material took place compared to unmodified wood control: - Cell wall modification was the most effective method to achieve high stiffness stabilization efficiency (up to 60%) and also increased compression strength (up to 230%). However, modulus of rupture, tensile, shear and the impact bending strength were reduced by both resins, but in a varying extent, where the N-methylol melamine formaldehyde endured less reduction than 1,3-dimethylol-4,5-dihydroxyethyleneurea resin. In the latter, reduction up to 60% can take place. - In the lumen fill modification: tetra-alkoxysilane has no effect in the mechanical properties. Although, a slight increase in shear strength parallel to the grain was found. Wax specimens have shown a slight increase in bending strength, compression, tensile and shear strength as well as in the absorption energy capacity.
Resumo:
Dissertação para obtenção do Grau de Mestre em Bioorgânica
Resumo:
This work compares the viscoelastic properties of an asphalt binder (70/100 pen) modified with different waste plastics and the mechanical properties of the resultant asphalt mixtures. Two different plastic wastes were used, namely recycled HDPE and EVA. Three different polymer modified binders were produced with these plastic wastes: i) 5% HDPE modified binder (P5); ii) 5% EVA modified binder (E5) and; iii) a modified binder with 4% of EVA and 2% HDPE (E4P2). Asphalt mixtures were produced with these modified binders, and their mechanical properties were analysed and compared with a conventional mixture produced with a 30/50 pen bitumen. It was possible to conclude that these recycled polymers are able to improve the mechanical performance of the asphalt mixtures used in road paving.
Resumo:
The aim of this study is evaluating the interaction between several base pen grade asphalt binders (35/50, 50/70, 70/100, 160/220) and two different plastic wastes (EVA and HDPE), for a set of new polymer modified binders produced with different amounts of both plastic wastes. After analysing the results obtained for the several polymer modified binders evaluated in this study, including a commercial modified binder, it can be concluded that the new PMBs produced with the base bitumen 70/100 and 5% of each plastic waste (HDPE or EVA) results in binders with very good performance, similar to that of the commercial modified binder.
Resumo:
Large amplitude oscillatory shear (LAOS) coupled with Fourier transform rheology (FTR) was used for the first time to characterize the large deformation behavior of selected bituminous binders at 20 C. Two polymer modified bitumens (PMB) containing recycled EVA and HDPE and two unmodified bitumens were tested with LAOS-FTR. The LAOS-FTR response of all binders was compared at same frequency, at same Deborah number (by tuning the frequency to the relaxation time of each binder) and at same phase shift angle d (by tuning the frequency to the one corresponding to d = 50 in the SAOS response of each sample). In all the approaches, LAOS-FTR results allowed to differentiate between all the nonlinear mechanical characteristics of the tested binders. All binders show LAOS-FTR patterns reminiscent from colloidal dispersions and emulsions. EVA PMB was less prone to strain-induced microstructural changes when compared to HDPE PMB which showed larger values of nonlinear FTR parameters for the range of shear strains tested in LAOS.
Resumo:
Versão dos autores para esta publicação.
Resumo:
El objetivo general de este proyecto de investigación es diseñar, desarrollar y optimizar superficies con propiedades especificas para ser utilizadas como sensores y biosensores, materiales biocompatibles, columnas para separaciones por electroforesis capilar, matrices para la liberación controlada de fármacos y sorbentes para remediación ambiental. Para concretar este objetivo, se propone específicamente modificar superficies o particulas apuntando a optimizar un sistema concreto relevante en aplicaciones farmaceuticas, ambientales o biomedicas: 1. Modificacion de arcillas naturales o sinteticas para desarrollar matrices portadoras de farmacos o sorbentes para remediacion ambiental:1.1 Estudiar ilitas modificadas con Fe(III) para maximizar las propiedades adsortivas frente a aniones contaminantes como arsenico. 1.2 Sintetizar LDH de Al y Mg modificados con compuestos de interés farmacéutico para diseñar sistemas de liberación controlada.2. Modificación de canales de chips y electrodos para optimizar la separación, detección y cuantificación de compuestos farmacéutico: 2.1 Diseñar y construir microchips para la separación por EC de compuestos de base fenólica.2.2 Evaluar polímeros que mejoren la respuesta y/o estabilidad de electrodos de Carbono para ser usados como detectores amperométrico de compuestos de base fenólica en sistemas FIA y miniaturizados de análisis integrados.3. Modificación de superficies sólidas con biomoléculas para el desarrollo y optimización de superficies de bio-reconocimiento:3.1 Evaluar el comportamiento de superficies de titanio modificadas con TiO2 y depósitos inorgánicos frente a la interacción con proteínas plasmáticas (PP) para el análisis de la biocompatibilidad superficial.3.2 Diseñar y desarrollar superficies biofuncionales para el reconocimiento especifico de D-aminoácidos, anticuerpos en pacientes chagásicos y simple hebra de ADN. Las técnicas que se emplearán para llevar a cabo el proyecto dependen del tipo de sistema de estudio. En particular los estudios correspondientes al objetivo 1 se realizarán mediante análisis químicos, térmico, DXR, SEM, IR, BET así como mediante titulaciones ácido-base potenciométricas, movilidades electroforéticas, cinética e isotermas de adsorción.En general para desarrollar el objetivo 2 se utilizarán técnicas electroquímicas clásicas para la caracterización de los electrodos, los que luego se utilizarán como detectores en un sistema FIA amperométrico, mientras que los microchips se emplearán en electroforesis capilar para la separación de diferentes compuestos de interés farmacéutico.Finalmente, el objetivo 3 se llevará a cabo por un lado modificando electrodos de titanio con distintos depósitos (electroquímicas, sol-gel, térmicas) de TiO2 e hidroxiapatita y evaluando la interacción con proteínas plasmáticas para analizar la biocompatibilidad de los materiales preparados. Por otro lado, se estudiará el proceso de adsorción-desorción de D-aminoácido oxidasa, antígenos del T. Cruzi y ADN de simple hebra para optmizar la capacidad de bio-reconocimiento superficial de D-aminoácidos, anticuerpos de chagásicos y de cadena complementaria de ADN. Para concretar este objetivo se utilizarán técnicas electroquímicas, espectroscópicas y microscopias.Debido al carácter multidisciplinario del presente proyecto de investigación, su ejecución se llevara a cabo a través de la colaboración de investigadores pertenecientes a distintas áreas de la Química y permitirá continuar con la formación de recursos humanos mediante la realización de tesis doctorales y estadías postdoctorales.
Resumo:
Magdeburg, Univ., Fak. für Verfahrens- und Systemtechnik, Diss., 2014
Resumo:
Intraoperative cardiac imaging plays a key role during transcatheter aortic valve replacement. In recent years, new techniques and new tools for improved image quality and virtual navigation have been proposed, in order to simplify and standardize stent valve positioning and implantation. But routine performance of the new techniques may require major economic investments or specific knowledge and skills and, for this reason, they may not be accessible to the majority of cardiac centres involved in transcatheter valve replacement projects. Additionally, they still require injections of contrast medium to obtain computed images. Therefore, we have developed and describe here a very simple and intuitive method of positioning balloon-expandable stent valves, which represents the evolution of the 'dumbbell' technique for echocardiography-guided transcatheter valve replacement without angiography. This method, based on the partial inflation of the balloon catheter during positioning, traps the crimped valve in the aortic valve orifice and, consequently, very near to the ideal landing zone. It does not require specific echocardiographic knowledge; it does not require angiographies that increase the risk of postoperative kidney failure in elderly patients, and it can be also performed in centres not equipped with a hybrid operating room.
Resumo:
Report for the scientific sojourn carried out at the Institut de Biologia Molecular de Barcelona of the CSIC –state agency – from april until september 2007. Topoisomerase I is an essential nuclear enzyme that modulates the topological status of DNA, facilitating DNA helix unwinding during replication and transcription. We have prepared the oligonucleotide-peptide conjugate Ac-NLeu-Asn-Tyr(p-3’TTCAGAAGC5’)-LeuC-CONH-(CH2)6-OH as model compound for NMR studies of the Topoisomerase I- DNA complex. Special attention was made on the synthetic aspects for the preparation of this challenging compound especially solid supports and protecting groups. The desired peptide was obtained although we did not achieve the amount of the conjugate needed for NMR studies. Most probably the low yield is due to the intrinsic sensitive to hydrolysis of the phosphate bond between oligonucleotide and tyrosine. We have started the synthesis and the structural characterization of oligonucleotides carrying intercalating compounds. At the present state we have obtained model duplex and quadruplex sequences modified with acridine and NMR studies are underway. In addition to this project we have successfully resolved the structure of a fusion peptide derived from hepatitis C virus envelope synthesized by the group of Dr. Haro and we have synthesized and started the characterization of a modified G-quadruplex.
Resumo:
Matrix effects, which represent an important issue in liquid chromatography coupled to mass spectrometry or tandem mass spectrometry detection, should be closely assessed during method development. In the case of quantitative analysis, the use of stable isotope-labelled internal standard with physico-chemical properties and ionization behaviour similar to the analyte is recommended. In this paper, an example of the choice of a co-eluting deuterated internal standard to compensate for short-term and long-term matrix effect in the case of chiral (R,S)-methadone plasma quantification is reported. The method was fully validated over a concentration range of 5-800 ng/mL for each methadone enantiomer with satisfactory relative bias (-1.0 to 1.0%), repeatability (0.9-4.9%) and intermediate precision (1.4-12.0%). From the results obtained during validation, a control chart process during 52 series of routine analysis was established using both intermediate precision standard deviation and FDA acceptance criteria. The results of routine quality control samples were generally included in the +/-15% variability around the target value and mainly in the two standard deviation interval illustrating the long-term stability of the method. The intermediate precision variability estimated in method validation was found to be coherent with the routine use of the method. During this period, 257 trough concentration and 54 peak concentration plasma samples of patients undergoing (R,S)-methadone treatment were successfully analysed for routine therapeutic drug monitoring.