994 resultados para mitral valve disease
Resumo:
Abstract Background: Transcatheter aortic valve implantation has become an option for high-surgical-risk patients with aortic valve disease. Objective: To evaluate the in-hospital and one-year follow-up outcomes of transcatheter aortic valve implantation. Methods: Prospective cohort study of transcatheter aortic valve implantation cases from July 2009 to February 2015. Analysis of clinical and procedural variables, correlating them with in-hospital and one-year mortality. Results: A total of 136 patients with a mean age of 83 years (80-87) underwent heart valve implantation; of these, 49% were women, 131 (96.3%) had aortic stenosis, one (0.7%) had aortic regurgitation and four (2.9%) had prosthetic valve dysfunction. NYHA functional class was III or IV in 129 cases (94.8%). The baseline orifice area was 0.67 ± 0.17 cm2 and the mean left ventricular-aortic pressure gradient was 47.3±18.2 mmHg, with an STS score of 9.3% (4.8%-22.3%). The prostheses implanted were self-expanding in 97% of cases. Perioperative mortality was 1.5%; 30-day mortality, 5.9%; in-hospital mortality, 8.1%; and one-year mortality, 15.5%. Blood transfusion (relative risk of 54; p = 0.0003) and pulmonary arterial hypertension (relative risk of 5.3; p = 0.036) were predictive of in-hospital mortality. Peak C-reactive protein (relative risk of 1.8; p = 0.013) and blood transfusion (relative risk of 8.3; p = 0.0009) were predictive of 1-year mortality. At 30 days, 97% of patients were in NYHA functional class I/II; at one year, this figure reached 96%. Conclusion: Transcatheter aortic valve implantation was performed with a high success rate and low mortality. Blood transfusion was associated with higher in-hospital and one-year mortality. Peak C-reactive protein was associated with one-year mortality.
Resumo:
We sought to provide a contemporary picture of the presentation, etiology, and outcome of infective endocarditis (IE) in a large patient cohort from multiple locations worldwide. Prospective cohort study of 2781 adults with definite IE who were admitted to 58 hospitals in 25 countries from June 1, 2000, through September 1, 2005. The median age of the cohort was 57.9 (interquartile range, 43.2-71.8) years, and 72.1% had native valve IE. Most patients (77.0%) presented early in the disease (<30 days) with few of the classic clinical hallmarks of IE. Recent health care exposure was found in one-quarter of patients. Staphylococcus aureus was the most common pathogen (31.2%). The mitral (41.1%) and aortic (37.6%) valves were infected most commonly. The following complications were common: stroke (16.9%), embolization other than stroke (22.6%), heart failure (32.3%), and intracardiac abscess (14.4%). Surgical therapy was common (48.2%), and in-hospital mortality remained high (17.7%). Prosthetic valve involvement (odds ratio, 1.47; 95% confidence interval, 1.13-1.90), increasing age (1.30; 1.17-1.46 per 10-year interval), pulmonary edema (1.79; 1.39-2.30), S aureus infection (1.54; 1.14-2.08), coagulase-negative staphylococcal infection (1.50; 1.07-2.10), mitral valve vegetation (1.34; 1.06-1.68), and paravalvular complications (2.25; 1.64-3.09) were associated with an increased risk of in-hospital death, whereas viridans streptococcal infection (0.52; 0.33-0.81) and surgery (0.61; 0.44-0.83) were associated with a decreased risk. In the early 21st century, IE is more often an acute disease, characterized by a high rate of S aureus infection. Mortality remains relatively high.
Resumo:
OBJECTIVES: Residual mitral regurgitation after valve repair worsens patients' clinical outcome. Postimplant adjustable mitral rings potentially address this issue, allowing the reshaping of the annulus on the beating heart under echocardiography control. We developed an original mitral ring allowing valve geometry remodelling after the implantation and designed an animal study to assess device effectiveness in correcting residual mitral regurgitation. METHODS: The device consists of two concentric rings: one internal and flexible, sutured to the mitral annulus and a second external and rigid. A third conic element slides between the two rings, modifying the shape of the flexible ring. This sliding element is remotely activated with a rotating tool. Animal model: in adult swine, under cardio pulmonary bypass and cardiac arrest, we shortened the primary chordae of P2 segment to reproduce Type III regurgitation and implanted the active ring. We used intracardiac ultrasound to assess mitral regurgitation and the efficacy of the active ring to correct it. RESULTS: Severe mitral regurgitation (3+ and 4+) was induced in eight animals, 54 ± 6 kg in weight. Vena contracta width decreased from 0.8 ± 0.2 to 0.1 cm; proximal isovelocity surface area radius decreased from 0.8 ± 0.2 to 0.1 cm and effective regurgitant orifice area decreased from 0.50 ± 0.1 to 0.1 ± 0.1 cm(2). Six animals had a reversal of systolic pulmonary flow that normalized following the activation of the device. All corrections were reversible. CONCLUSIONS: Postimplant adjustable mitral ring corrects severe mitral regurgitation through the reversible modification of the annulus geometry on the beating heart. It addresses the frequent and morbid issue of recurrent mitral valve regurgitation.
Resumo:
Introduction and Aims: Fabry disease is an X-linked lysosomal storage disorder caused by absence or deficient activity of the lysosomal enzyme alpha-galactosidase A. Renal manifestations occur early in life in a significant proportion of children, in many women and in almost all men with Fabry disease. These manifestations ultimately progress to end-stage renal disease in nearly all males and in some female patients. Data on kidney transplantation in patients with Fabry disease who are receiving enzyme replacement therapy (ERT), however, are scarce. Methods: We examined the clinical characteristics of kidney transplant recipients (KTRs) in the Fabry Outcome Survey (FOS) - a European database of patients with Fabry disease that was established to monitor the safety and outcome of ERT. Results: Of the 752 patients enrolled in FOS up to October 2005, 34 (4.5%) were reported to be KTRs. The mean age of these 32 male and 2 female patients was 45 ± 9 years, the median time since the transplant was 9 years, the median estimated glomerular filtration rate (eGFR) was 46 mL/min/1.73 m2 and the median level of proteinuria was 180 mg/24 hours. ERT was well tolerated, with mild infusion-related reactions reported in only one patient. Amongst these patients, 53% were reported to have hypertension, 71% left ventricular hypertrophy, 27% cardiac valve disease and 27% arrhythmia. A total of 23 (68%) of the patients (1 female, 22 males) were receiving ERT with agalsidase alfa (Replagal; Shire Human Genetic Therapies, UK), with a median duration of treatment of 2.5 years. There were no differences in age or time since transplantation between treated and untreated patients. The median eGFRs were 46 and 49 mL/min/1.73 m2 and the median levels of proteinuria were 200 and 160 mg/24 hours, respectively. Conclusions: KTRs represent a significant minority of individuals enrolled in a large international registry of patients with Fabry disease (FOS). Approximately two-thirds of KTRs with Fabry disease enrolled in FOS receive ERT with agalsidase alfa, which is well tolerated. Comparison of treated and untreated patients has the potential to examine effects of ERT on the progression of renal and cardiovascular disease.
Resumo:
BACKGROUND: The objective of the present study was to compare current results of prosthetic valve replacement following acute infective native valve endocarditis (NVE) with that of prosthetic valve endocarditis (PVE). Prosthetic valve replacement is often necessary for acute infective endocarditis. Although valve repair and homografts have been associated with excellent outcome, homograft availability and the importance of valvular destruction often dictate prosthetic valve replacement in patients with acute bacterial endocarditis. METHODS: A retrospective analysis of the experience with prosthetic valve replacement following acute NVE and PVE between 1988 and 1998 was performed at the Montreal Heart Institute. RESULTS: Seventy-seven patients (57 men and 20 women, mean age 48 +/- 16 years) with acute infective endocarditis underwent valve replacement. Fifty patients had NVE and 27 had PVE. Four patients (8%) with NVE died within 30 days of operation and there were no hospital deaths in patients with PVE. Survival at 1, 5, and 7 years averaged 80% +/- 6%, 76% +/- 6%, and 76% +/- 6% for NVE and 70% +/- 9%, 59% +/- 10%, and 55% +/- 10% for PVE, respectively (p = 0.15). Reoperation-free survival at 1, 5, and 7 years averaged 80% +/- 6%, 76% +/- 6%, and 76% +/- 6% for NVE and 45% +/- 10%, 40% +/- 10%, and 36% +/- 9% for PVE (p = 0.003). Five-year survival for NVE averaged 75% +/- 9% following aortic valve replacement and 79% +/- 9% following mitral valve replacement. Five-year survival for PVE averaged 66% +/- 12% following aortic valve replacement and 43% +/- 19% following mitral valve replacement (p = 0.75). Nine patients underwent reoperation during follow-up: indications were prosthesis infection in 4 patients (3 mitral, 1 aortic), dehiscence of mitral prosthesis in 3, and dehiscence of aortic prosthesis in 2. CONCLUSIONS: Prosthetic valve replacement for NVE resulted in good long-term patient survival with a minimal risk of reoperation compared with patients who underwent valve replacement for PVE. In patients with PVE, those who needed reoperation had recurrent endocarditis or noninfectious periprosthetic dehiscence.
Resumo:
Quadricuspid aortic valve (QAV) is a rare congenital anomaly associated with aortic valve insufficiency and significant morbidity, and requires the replacement or, rarely, the repair of the malfunctioning heart valve. A QAV associated with an ascending aorta aneurysm is an extremely rare anatomic combination with a hypothetical, but not clear, shared embryological etiology. To date, only two cases of type B QAV with ascending aorta aneurysm have been reported. Herein is described the first ever case of a 38-year-old male suffering from severe symptomatic aortic valve regurgitation due to a type A QAV, associated with an ascending aorta aneurism, who underwent a successful combined replacement of the aortic valve and ascending aorta.
Resumo:
Because of its severity, it is agreed that infectious endocarditis should be prevented whenever possible. Determining adequate prophylactic measures involves establishing (a) the patients at risk, (b) the procedures that might provoke bacteraemia, (c) the most effective prophylactic regimen, and (d) a balance between the risks of side effects from prophylaxis and of developing infectious endocarditis. Patients at risk and procedures inducing bacteraemia have been identified by clinical studies. On the other hand, the efficacy of prophylactic antibiotics has been based on animal studies. Randomised, placebo-controlled studies do not exist in humans because they would require large patient numbers and would raise ethical issues due to the severity of the disease. Case-control studies have indicated that infectious endocarditis prophylaxis is effective, but prevents only a limited number of cases. Animal experiments have revealed several key issues for human application. First, antibiotics do not prevent the early stages of valve colonisation, but rather kill the microorganisms after their attachment to the cardiac lesions. Second, the duration of antibiotic presence in the serum is critical. Under experimental conditions, the drugs must remain above their minimal inhibitory concentration for the organisms for > or = 10 h, to allow time for bacterial clearance from the valves. Third, antibiotic-induced killing is not the only mechanism allowing bacterial clearance. Other factors, such as platelet microbicidal proteins, may act in concert with the drugs to sterilise the lesions. Recommendations for prophylaxis have recently been revised in Europe and the USA. New information has improved the definition of groups at risk. Since most cases of infectious endocarditis are not preceded by medical procedures, primary prevention of infectious endocarditis should target infected foci responsible for spontaneous bacteraemia (e.g. poor dental hygiene). The purpose of this article is to update the existing recommendations in Switzerland, under the perspective of changing epidemiology, the availability of new drugs, and harmonisation with recommendations in other countries.
Resumo:
The short and the long-term results of our experience with 25 consecutive patients who underwent multivalvular surgery for infective endocarditis are analysed. Preoperatively, 20/25 (80%) patients were in New York Heart Association (NYHA) stage III or IV, and 2/25 (8%) patients were in cardiogenic shock. All the diseased valves were replaced with mechanical bileaflet prosthesis except seven mitral valves and one tricuspid valve, which could be repaired. Major postoperative complications occurred in 3/25 (12%) patients: a fatal cerebral haemorrhage, a reversible cerebellar syndrome and an intractable heart failure, which required transplantation. During a mean follow-up of 4.7 years (range 6 months to 16.8 years), 7/25 (28%) patients suffered from valve-related complications: five bleedings (one died), one embolic event and one prosthetic valve thrombosis. The actuarial freedom of valve-related event at 10 years was 61.8 +/- 12.4%. There was no prosthetic endocarditis. At follow-up, 20/21 (95%) survivors were in NYHA stage I or II. Long-term outcome in our patient population operated on for multivalvular endocarditis, is satisfactory with no recurrent infection and excellent functional results.
Resumo:
Background and aim of the study: Bicuspid aortic valve is the most common congenital heart malformation, and a high percentage of patients with this condition will develop complications over time. It is rare that pilots undergo aortic valve surgery, and the confirmation of flight-licensing requirements after aortic valve replacement (AVR) is a challenge for the patient's cardiac surgeon and, particularly, for the Aeromedical Examiner (AME). Only AMEs are able to determine the flight status of pilots. Furthermore, in military and in civil aviation (e.g., Red Bull Air Race), the high G-load environment experienced by pilots is an exceptional physiological parameter, which must be considered postoperatively. Methods: A review was conducted of the aeronautical, surgical and medical literature, and of European pilot-licensing regulations. Case studies are also reported for two Swiss Air Force pilots. Results: According to European legislation, pilots can return to flight duty from the sixth postoperative month, with the following limitations: that an aortic bioprosthesis presents no restrictions in cardiac function, requires no cardioactive medications, yet requires a flight operation with co-pilot, the avoidance of accelerations over +3 Gz and, in military aviation, restricts the pilot to non-ejection-seat aircraft. The patient follow up must include both echocardiographic and rhythm assessments every six months. Mechanical prostheses cannot be certified because the required anticoagulation therapy is a disqualifying condition for pilot licensing. Conclusion: Pilot licensing after aortic valve surgery is possible, but with restrictions. The +Gz exposition is of concern in both military and civilian aviation (aerobatics). The choice of bioprosthesis type and size is determinant. Pericardial and stentless valves seem to show better flow characteristics under high-output conditions. Repetitive cardiological controls are mandatory for the early assessment of structural valve disease and rhythm disturbances. A pre-emptive timing is recommended when reoperation is indicated, without waiting for clinical manifestations of structural valve disease.
Resumo:
ABSTRACT: Transapical aortic valve replacement is an established technique performed in high-risk patients with symptomatic aortic valve stenosis and vascular disease contraindicating trans-vascular and trans-aortic procedures. The presence of a left ventricular apical diverticulum is a rare event and the treatment depends on dimensions and estimated risk of embolisation, rupture, or onset of ventricular arrhythmias. The diagnosis is based on standard cardiac imaging and symptoms are very rare. In this case report we illustrate our experience with a 81 years old female patient suffering from symptomatic aortic valve stenosis, respiratory disease, chronic renal failure and severe peripheral vascular disease (logistic euroscore: 42%), who successfully underwent a transapical 23 mm balloon-expandable stent-valve implantation through an apical diverticulum of the left ventricle. Intra-luminal thrombi were absent and during the same procedure were able to treat the valve disease and to successfully exclude the apical diverticulum without complications and through a mini thoracotomy. To the best of our knowledge, this is the first time that a transapical procedure is successfully performed through an apical diverticulum.
Resumo:
Bioprosthetic aortic valve replacement is the treatment of choice for patients over 65 years of age suffering from aortic valve disease, and for younger patients with contraindications to long-lasting anticoagulation. Despite several technical improvements to reduce the risk of structural valve degeneration (SVD), the risk of SVD still exists, in particular for hemodialysis patients and patients under 60 years of age at surgery. Redo open heart surgery is the treatment of choice in case of valve degeneration, but caries a higher surgical risk when elderly patients with comorbidities are concerned. In the last 5 years, transcatheter aortic "valve-in-valve" procedures represent a valid alternative to standard redo surgery in selected patients. Valve-in-valve procedures represent a less invasive approach in high-risk patients and the published results are very encouraging. Technical success rates of 100% have been reported, as have the absence of paravalvular leaks, acceptable trans-valvular gradients (depending on the size of the original bioprosthesis), and low complication rates. The current article focuses on choosing the correct transcutaneous valve to match the patient's existing bioprosthesis for valve-in-valve procedures.
Resumo:
BACKGROUND AND AIM OF THE STUDY: Transapical transcatheter aortic valve replacement (TAVR) is a new minimally invasive technique with a known risk of unexpected intra-procedural complications. Nevertheless, the clinical results are good and the limited amount of procedural adverse events confirms the usefulness of a synergistic surgical/anesthesiological management in case of unexpected emergencies. METHODS: A review was made of the authors' four-year database and other available literature to identify major and minor intra-procedural complications occurring during transapical TAVR procedures. All implants were performed under general anesthesia with a balloon-expandable Edwards Sapien stent-valve, and followed international guidelines on indications and techniques. RESULTS: Procedural success rates ranged between 94% and 100%. Life-threatening apical bleeding occurred very rarely (0-5%), and its incidence decreased after the first series of implants. Stent-valve embolization was also rare, with a global incidence ranging from 0-2%, with evidence of improvement after the learning curve. Rates of valve malpositioning ranged from 0% to < 3%, whereas the risk of coronary obstruction ranged from 0% to 3.5%. Aortic root rupture and dissection were dramatic events reported in 0-2% of transapical cases. Stent-valve malfunction was rarely reported (1-2%), whereas the valve-in-valve bailout procedure for malpositioning, malfunctioning or severe paravalvular leak was reported in about 1.0-3.5% of cases. Sudden hemodynamic management and bailout procedures such as valve-in-valve rescue or cannulation for cardiopulmonary bypass were more effective when planned during the preoperative phase. CONCLUSION: Despite attempts to avoid pitfalls, complications during transapical aortic valve procedures still occur. Preoperative strategic planning, including hemodynamic status management, alternative cannulation sites and bailout procedures, are highly recommended, particularly during the learning curve of this technique.