923 resultados para metal trace analysis


Relevância:

40.00% 40.00%

Publicador:

Resumo:

n this work, three Cypraea species (C. talpa, C. tigris and C. zebra) were exhaustively studied. The shells have been separated in the structural layers. The mineralogy, ultra- and micro-structure of each layer were analyzed by Confocal Laser Scanning Microscopy (CLSM), Scanning Electron Microscopy (SEM), X-Ray Diffractometry (XRD) and Raman Spectroscopy (RS). The presence of biologically relevant trace metals (Mn, Co, Fe, Zn, Cr, etc.) has been investigated using Instrumental Neutron Activation Analysis (INAA) and Inductively Coupled Plasma – Mass Spectrometry (ICP-MS) as detection tool. A new method has been developed and optimized to extract and analyze the soluble organic matrix (SOM) of the shell. Although the molecular nature of the SOM is not really known, it contains at least large protein fraction, if not only consists of proteins. The extracted matrices were compared between layers and species using Size Exclusion High Performance Liquid Chromatography coupled with Ultra Violet Spectrometry (SE-HPLC-UV), Gel electrophoresis (GE) and protein quantification tests. For the first time to our knowledge the association of trace elements to the protein in the SOM of the shell was studied using hyphenated on line as well as combined off line techniques and validated through inter-comparison tests between the different methods applied. Interesting correlations between the trace element concentration, the microstructure and the protein content were directly and indirectly detected. The metals Cu, Ni, Co and Zn have shown to bind to the SOM extracted from C. talpa, C. tigris and C. zebra shells. Within the conclusions of this work it was demonstrated that these protein-metal-complexes (or metal containing proteins) change from one layer to the other and are different between the three snails analyzed. In addition, the complexes are clearly related only to certain protein fractions of the SOM, and not to the whole SOM observed. These fractions and show not to be very metal-specific (i.e. some of these fractions bind two or three different metals).

Relevância:

40.00% 40.00%

Publicador:

Resumo:

The relative safety of drug-eluting stents and bare-metal stents, especially with respect to stent thrombosis, continues to be debated. In view of the overall low frequency of stent thrombosis, large sample sizes are needed to accurately estimate treatment differences between stents. We compared the risk of thrombosis between bare-metal and drug-eluting stents.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Whether the two drug-eluting stents approved by the US Food and Drug Administration-a sirolimus-eluting stent and a paclitaxel-eluting stent-are associated with increased risks of death, myocardial infarction, or stent thrombosis compared with bare-metal stents is uncertain. Our aim was to compare the safety and effectiveness of these stents.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Objective To compare the effectiveness and safety of three types of stents (sirolimus eluting, paclitaxel eluting, and bare metal) in people with and without diabetes mellitus. Design Collaborative network meta-analysis. Data sources Electronic databases (Medline, Embase, the Cochrane Central Register of Controlled Trials), relevant websites, reference lists, conference abstracts, reviews, book chapters, and proceedings of advisory panels for the US Food and Drug Administration. Manufacturers and trialists provided additional data. Review methods Network meta-analysis with a mixed treatment comparison method to combine direct within trial comparisons between stents with indirect evidence from other trials while maintaining randomisation. Overall mortality was the primary safety end point, target lesion revascularisation the effectiveness end point. Results 35 trials in 3852 people with diabetes and 10 947 people without diabetes contributed to the analyses. Inconsistency of the network was substantial for overall mortality in people with diabetes and seemed to be related to the duration of dual antiplatelet therapy (P value for interaction 0.02). Restricting the analysis to trials with a duration of dual antiplatelet therapy of six months or more, inconsistency was reduced considerably and hazard ratios for overall mortality were near one for all comparisons in people with diabetes: sirolimus eluting stents compared with bare metal stents 0.88 (95% credibility interval 0.55 to 1.30), paclitaxel eluting stents compared with bare metal stents 0.91 (0.60 to 1.38), and sirolimus eluting stents compared with paclitaxel eluting stents 0.95 (0.63 to 1.43). In people without diabetes, hazard ratios were unaffected by the restriction. Both drug eluting stents were associated with a decrease in revascularisation rates compared with bare metal stents in people both with and without diabetes. Conclusion In trials that specified a duration of dual antiplatelet therapy of six months or more after stent implantation, drug eluting stents seemed safe and effective in people both with and without diabetes.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Bathurst Harbour in World Heritage southwest Tasmania, Australia, is one of the world’s most pristine estuarine systems. At present there is a lack of data on pollution impacts or long-term natural variability in the harbor. A ca. 350-year-old 210Pb-dated sediment core was analysed for trace metals to track pollution impacts from local and long-range sources. Lead and antimony increased from AD 1870 onwards, which likely reflects remote (i.e. mainland Australian and global) atmospheric pollution sources. Variability in the concentrations of copper and zinc closely followed the history of mining activities in western Tasmania, which began in the AD 1880s. Tin was generally low throughout the core, except for a large peak in AD 1989 ± 0.5 years, which may be a consequence of input from a local small-scale alluvial tin mine. Changes in diatom assemblages were also investigated. The diatom flora was composed mostly of planktonic freshwater and benthic brackish-marine species, consistent with stratified estuarine conditions. Since mining began, however, an overall decrease in the proportion of planktonic to benthic taxa occurred, with the exception of two distinct peaks in the twentieth century that coincided with periods of high rainfall. Despite the region’s remoteness, trace metal analyses revealed evidence of atmospheric pollution from Tasmanian and possibly longer-range mining activities. This, together with recent low rainfall, appears to have contributed to altering the diatom assemblages in one of the most pristine temperate estuaries in the world.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

OBJECTIVES This study sought to study the efficacy and safety of newer-generation drug-eluting stents (DES) compared with bare-metal stents (BMS) in an appropriately powered population of patients with ST-segment elevation myocardial infarction (STEMI). BACKGROUND Among patients with STEMI, early generation DES improved efficacy but not safety compared with BMS. Newer-generation DES, everolimus-eluting stents, and biolimus A9-eluting stents, have been shown to improve clinical outcomes compared with early generation DES. METHODS Individual patient data for 2,665 STEMI patients enrolled in 2 large-scale randomized clinical trials comparing newer-generation DES with BMS were pooled: 1,326 patients received a newer-generation DES (everolimus-eluting stent or biolimus A9-eluting stent), whereas the remaining 1,329 patients received a BMS. Random-effects models were used to assess differences between the 2 groups for the device-oriented composite endpoint of cardiac death, target-vessel reinfarction, and target-lesion revascularization and the patient-oriented composite endpoint of all-cause death, any infarction, and any revascularization at 1 year. RESULTS Newer-generation DES substantially reduce the risk of the device-oriented composite endpoint compared with BMS at 1 year (relative risk [RR]: 0.58; 95% confidence interval [CI]: 0.43 to 0.79; p = 0.0004). Similarly, the risk of the patient-oriented composite endpoint was lower with newer-generation DES than BMS (RR: 0.78; 95% CI: 0.63 to 0.96; p = 0.02). Differences in favor of newer-generation DES were driven by both a lower risk of repeat revascularization of the target lesion (RR: 0.33; 95% CI: 0.20 to 0.52; p < 0.0001) and a lower risk of target-vessel infarction (RR: 0.36; 95% CI: 0.14 to 0.92; p = 0.03). Newer-generation DES also reduced the risk of definite stent thrombosis (RR: 0.35; 95% CI: 0.16 to 0.75; p = 0.006) compared with BMS. CONCLUSIONS Among patients with STEMI, newer-generation DES improve safety and efficacy compared with BMS throughout 1 year. It remains to be determined whether the differences in favor of newer-generation DES are sustained during long-term follow-up.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

BACKGROUND In patients with cardiogenic shock, data on the comparative safety and efficacy of drug-eluting stents (DESs) vs. bare metal stents (BMSs) are lacking. We sought to assess the performance of DESs compared with BMSs among patients with cardiogenic shock undergoing percutaneous coronary intervention (PCI). METHODS Out of 236 patients with acute coronary syndromes complicated by cardiogenic shock, 203 were included in the final analysis. The primary endpoint included death, and the secondary endpoint of major adverse cardiac and cerebrovascular events (MACCEs) included the composite of death, myocardial infarction, any repeat revascularization and stroke. Patients were followed for a minimum of 30 days and up to 4 years. As stent assignment was not random, we performed a propensity score analysis to minimize potential bias. RESULTS Among patients treated with DESs, there was a lower risk of the primary and secondary endpoints compared with BMSs at 30 days (29 vs. 56%, P < 0.001; 34 vs. 58%, P = 0.001, respectively) and during long-term follow-up [hazard ratio 0.43, 95% confidence interval (CI) 0.29-0.65, P < 0.001; hazard ratio 0.49, 95% CI 0.34-0.71, P < 0.001, respectively]. After propensity score adjustment, all-cause mortality was reduced among patients treated with DESs compared with BMSs both at 30 days [adjusted odds ratio (OR) 0.26, 95% CI 0.11-0.62; P = 0.002] and during long-term follow-up (adjusted hazard ratio 0.40, 95% CI 0.22-0.72; P = 0.002). The rate of MACCE was lower among patients treated with DESs compared with those treated with BMSs at 30 days (adjusted OR 0.42, 95% CI 0.19-0.95; P = 0.036). The difference in MACCEs between devices approached significance during long-term follow-up (adjusted hazard ratio 0.60, 95% CI 0.34-1.01; P = 0.052). CONCLUSION DESs appear to be associated with improved clinical outcomes, including a reduction in all-cause mortality compared with BMSs among patients undergoing PCI for cardiogenic shock, possibly because of a pacification of the infarct-related artery by anti-inflammatory drug. The results of this observational study require confirmation in an appropriately powered randomized trial.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

BACKGROUND Recently, it has been suggested that the type of stent used in primary percutaneous coronary interventions (pPCI) might impact upon the outcomes of patients with acute myocardial infarction (AMI). Indeed, drug-eluting stents (DES) reduce neointimal hyperplasia compared to bare-metal stents (BMS). Moreover, the later generation DES, due to its biocompatible polymer coatings and stent design, allows for greater deliverability, improved endothelial healing and therefore less restenosis and thrombus generation. However, data on the safety and performance of DES in large cohorts of AMI is still limited. AIM To compare the early outcome of DES vs. BMS in AMI patients. METHODS This was a prospective, multicentre analysis containing patients from 64 hospitals in Switzerland with AMI undergoing pPCI between 2005 and 2013. The primary endpoint was in-hospital all-cause death, whereas the secondary endpoint included a composite measure of major adverse cardiac and cerebrovascular events (MACCE) of death, reinfarction, and cerebrovascular event. RESULTS Of 20,464 patients with a primary diagnosis of AMI and enrolled to the AMIS Plus registry, 15,026 were referred for pPCI and 13,442 received stent implantation. 10,094 patients were implanted with DES and 2,260 with BMS. The overall in-hospital mortality was significantly lower in patients with DES compared to those with BMS implantation (2.6% vs. 7.1%,p < 0.001). The overall in-hospital MACCE after DES was similarly lower compared to BMS (3.5% vs. 7.6%, p < 0.001). After adjusting for all confounding covariables, DES remained an independent predictor for lower in-hospital mortality (OR 0.51,95% CI 0.40-0.67, p < 0.001). Since groups differed as regards to baseline characteristics and pharmacological treatment, we performed a propensity score matching (PSM) to limit potential biases. Even after the PSM, DES implantation remained independently associated with a reduced risk of in-hospital mortality (adjusted OR 0.54, 95% CI 0.39-0.76, p < 0.001). CONCLUSIONS In unselected patients from a nationwide, real-world cohort, we found DES, compared to BMS, was associated with lower in-hospital mortality and MACCE. The identification of optimal treatment strategies of patients with AMI needs further randomised evaluation; however, our findings suggest a potential benefit with DES.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Cathodoluminescence (CL) studies have previously shown that some secondary fluid inclusions in luminescent quartz are surrounded by dark, non-luminescent patches, resulting from fracture-sealing by late, trace-element-poor quartz. This finding has led to the tacit generalization that all dark CL patches indicate influx of low temperature, late-stage fluids. In this study we have examined natural and synthetic hydrothermal quartz crystals using CL imaging supplemented by in-situ elemental analysis. The results lead us to propose that all natural, liquid-water-bearing inclusions in quartz, whether trapped on former crystal growth surfaces (i.e., of primary origin) or in healed fractures (i.e., of pseudosecondary or secondary origin), are surrounded by three-dimensional, non-luminescent patches. Cross-cutting relations show that the patches form after entrapment of the fluid inclusions and therefore they are not diagnostic of the timing of fluid entrapment. Instead, the dark patches reveal the mechanism by which fluid inclusions spontaneously approach morphological equilibrium and purify their host quartz over geological time. Fluid inclusions that contain solvent water perpetually dissolve and reprecipitate their walls, gradually adopting low-energy euhedral and equant shapes. Defects in the host quartz constitute solubility gradients that drive physical migration of the inclusions over distances of tens of μm (commonly) up to several mm (rarely). Inclusions thus sequester from their walls any trace elements (e.g., Li, Al, Na, Ti) present in excess of equilibrium concentrations, thereby chemically purifying their host crystals in a process analogous to industrial zone refining. Non-luminescent patches of quartz are left in their wake. Fluid inclusions that contain no liquid water as solvent (e.g., inclusions of low-density H2O vapor or other non-aqueous volatiles) do not undergo this process and therefore do not migrate, do not modify their shapes with time, and are not associated with dark-CL zone-refined patches. This new understanding has implications for the interpretation of solids within fluid inclusions (e.g., Ti- and Al-minerals) and for the elemental analysis of hydrothermal and metamorphic quartz and its fluid inclusions by microbeam methods such as LA-ICPMS and SIMS. As Ti is a common trace element in quartz, its sequestration by fluid inclusions and its depletion in zone-refined patches impacts on applications of the Ti-in-quartz geothermometer.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

The nonresidual concentrations of five trace metals were determined for 322 sediments that were the product of a systematic sampling program of the entire Galveston Bay system. The nonresidual component of the trace metal concentration (e.g. that fraction of the metals that can be relatively easily removed from the sediments without complete destruction of the sediment particle) was considered to be more indicative of the anthropogenic metal pollution that has impacted the Galveston Bay ecosystem.^ For spatial analysis of the metal concentrations, the Galveston Bay system was divided into nine bay-areas, based on easily definable geological and geographical characteristics. Isopleth mapping analyses of these metal concentrations indicated a direct relationship with the $<$63$\mu$m fraction of the sediment (%FINE) in all of the bay areas. Covariate regression analyses indicated that position of the sediment within the Galveston Bay system (e.g. bay-area) was a better predictor of metal concentration than %FINE. Analysis of variance of the metals versus the bay-areas indicated that the five metals maintained a relatively constant order and magnitude of concentration for all the bay-areas.^ The major shipping channels of the Galveston Bay system, with their associated vessels and transported materials, are a likely source of metal pollution. However, these channels were not depositional corridors of high metal concentration. All metal concentration highs were found to be located away from the channels and associated with %FINE highs in the deeper portions of the bay-areas.^ Disturbance of the sediments, by the proposed widening and deepening of these channels, is not predicted to remobilize the trace metals. A more likely adverse effect on the health of the Galveston Bay ecosystem would come from the increase in turbidity of the water due to the dredging and in an extension of the salt water wedge farther north into the bay system. ^