998 resultados para medical developments


Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper presents work in progress, to develop an efficient and economic way to directly produce Technetium 99metastable (99mTc) using low-energy cyclotrons. Its importance is well established and relates with the increased global trouble in delivering 99mTc to Nuclear Medicine Departments relying on this radioisotope. Since the present delivery strategy has clearly demonstrated its intrinsic limits, our group decided to follow a distinct approach that uses the broad distribution of the low energy cyclotrons and the accessibility of Molybdenum 100 (100Mo) as the Target material. This is indeed an important issue to consider, since the system here presented, named CYCLOTECH, it is not based on the use of Highly Enriched (or even Low Enriched) Uranium 235 (235U), so entirely complying with the actual international trends and directives concerning the use of this potential highly critical material. The production technique is based on the nuclear reaction 100Mo (p,2n) 99mTc whose production yields have already been documented. Until this moment two Patent requests have already been submitted (the first at the INPI, in Portugal, and the second at the USPTO, in the USA); others are being prepared for submission on a near future. The object of the CYCLOTECH system is to present 99mTc to Nuclear Medicine radiopharmacists in a routine, reliable and efficient manner that, remaining always flexible, entirely blends with established protocols. To facilitate workflow and Radiation Protection measures, it has been developed a Target Station that can be installed on most of the existing PET cyclotrons and that will tolerate up to 400 μA of beam by allowing the beam to strike the Target material at an adequately oblique angle. The Target Station permits the remote and automatic loading and discharge of the Targets from a carriage of 10 Target bodies. On other hand, several methods of Target material deposition and Target substrates are presented. The object was to create a cost effective means of depositing and intermediate the target material thickness (25 - 100μm) with a minimum of loss on a substrate that is able to easily transport the heat associated with high beam currents. Finally, the separation techniques presented are a combination of both physical and column chemistry. The object was to extract and deliver 99mTc in the identical form now in use in radiopharmacies worldwide. In addition, the Target material is recovered and can be recycled.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objetivos – Um dos principais objetivos da neurociência tem sido, desde sempre, compreender as funcionalidades do cérebro. A introdução da ressonância magnética funcional contribuiu em grande escala para o desenvolvimento do estudo cerebral. Assim, esta investigação tem como principal objetivo identificar e desenhar os diferentes perfis de localizações cerebrais, a nível do córtex motor, numa população jovem saudável, permitindo, assim, um maior conhecimento nesta área e dando um contributo à área da neurologia. Material e métodos – Foi realizado um estudo de ressonância magnética funcional em 30 indivíduos saudáveis numa clínica de imagiologia médica. Para tal recorreu-se a equipamento adequado para a recolha de dados. O paradigma motor utilizado foi o movimento dos dedos das mãos. Através das imagens obtidas foi medida a área de cada região ativa. Com o suporte do programa SPSS (versão 19) todos os valores foram tratados estatisticamente. Conclusão – Após todo este processo concluiu-se que a área do cérebro maioritariamente ativa, no momento do paradigma motor, encontra-se no hemisfério esquerdo.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE: To assess direct medical costs associated with schizophrenia relapses in mental health services. METHODS: The study was conducted in three health facilities in the city of São Paulo: a public state hospital; a Brazilian National Health System (SUS)-contracted hospital; and a community mental health center. Medical records of 90 patients with schizophrenia who received care in 2006 were reviewed. Information on inpatient expenditures was collected and used for cost estimates. RESULTS: Mean direct medical cost of schizophrenia relapses per patient was US$ 4,083.50 (R$ 8,167.58) in the public state hospital; US$ 2,302.76 (R$ 4,605.46) in the community mental health center; and US$ 1,198.50 (R$ 2,397.74) in the SUS-affiliated hospital. The main component was daily inpatient room rates (87% - 98%). Medication costs varied depending on the use of typical or atypical antipsychotic drugs. Atypical antipsychotic drugs were more often used in the community mental health center. CONCLUSIONS: Costs associated with schizophrenia relapses support investments in antipsychotic drugs and strategies to reduce disease relapse and the need for mental health inpatient services. Treating patients in a community mental health center was associated with medium costs and added the benefit of not depriving these patients from family life.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Ethernet is the most popular LAN technology. Its low price and robustness, resulting from its wide acceptance and deployment, has created an eagerness to expand its responsibilities to the factory-floor, where real-time requirements are to be fulfilled. However, it is difficult to build a real-time control network using Ethernet, because its MAC protocol, the 1-persistent CSMA/CD protocol with the BEB collision resolution algorithm, has unpredictable delay characteristics. Many anticipate that the recent technological advances in Ethernet such as the emerging Fast/Gigabit Ethernet, micro-segmentation and full-duplex operation using switches will also enable it to support time-critical applications. This technical report provides a comprehensive look at the unpredictability inherent to Ethernet and at recent technological advances towards real-time operation.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Medical imaging is a powerful diagnostic tool. Consequently, the number of medical images taken has increased vastly over the past few decades. The most common medical imaging techniques use X-radiation as the primary investigative tool. The main limitation of using X-radiation is associated with the risk of developing cancers. Alongside this, technology has advanced and more centres now use CT scanners; these can incur significant radiation burdens compared with traditional X-ray imaging systems. The net effect is that the population radiation burden is rising steadily. Risk arising from X-radiation for diagnostic medical purposes needs minimising and one way to achieve this is through reducing radiation dose whilst optimising image quality. All ages are affected by risk from X-radiation however the increasing population age highlights the elderly as a new group that may require consideration. Of greatest concern are paediatric patients: firstly they are more sensitive to radiation; secondly their younger age means that the potential detriment to this group is greater. Containment of radiation exposure falls to a number of professionals within medical fields, from those who request imaging to those who produce the image. These staff are supported in their radiation protection role by engineers, physicists and technicians. It is important to realise that radiation protection is currently a major European focus of interest and minimum competence levels in radiation protection for radiographers have been defined through the integrated activities of the EU consortium called MEDRAPET. The outcomes of this project have been used by the European Federation of Radiographer Societies to describe the European Qualifications Framework levels for radiographers in radiation protection. Though variations exist between European countries radiographers and nuclear medicine technologists are normally the professional groups who are responsible for exposing screening populations and patients to X-radiation. As part of their training they learn fundamental principles of radiation protection and theoretical and practical approaches to dose minimisation. However dose minimisation is complex – it is not simply about reducing X-radiation without taking into account major contextual factors. These factors relate to the real world of clinical imaging and include the need to measure clinical image quality and lesion visibility when applying X-radiation dose reduction strategies. This requires the use of validated psychological and physics techniques to measure clinical image quality and lesion perceptibility.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Environmental microbiology is an evolving science. This is in part driven by the development of new analytical techniques that are becoming more varied and powerful. Before they are applied, emerging techniques need to be critically evaluated by scientists, technical professionals, practitioners and students.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Mestrado em Radiações Aplicadas às Tecnologias da Saúde

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Aims of study: 1) Describe the importance of human visual system on lesion detection in medical imaging perception research; 2) Discuss the relevance of research in medical imaging addressing visual function analysis; 3) Identify visual function tests which could be conducted on observers prior to participation in medical imaging perception research.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Arquivos de Medicina 1998; 12(4): 246-248

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background - Medical image perception research relies on visual data to study the diagnostic relationship between observers and medical images. A consistent method to assess visual function for participants in medical imaging research has not been developed and represents a significant gap in existing research. Methods - Three visual assessment factors appropriate to observer studies were identified: visual acuity, contrast sensitivity, and stereopsis. A test was designed for each, and 30 radiography observers (mean age 31.6 years) participated in each test. Results - Mean binocular visual acuity for distance was 20/14 for all observers. The difference between observers who did and did not use corrective lenses was not statistically significant (P = .12). All subjects had a normal value for near visual acuity and stereoacuity. Contrast sensitivity was better than population norms. Conclusion - All observers had normal visual function and could participate in medical imaging visual analysis studies. Protocols of evaluation and populations norms are provided. Further studies are necessary to understand fully the relationship between visual performance on tests and diagnostic accuracy in practice.

Relevância:

20.00% 20.00%

Publicador:

Relevância:

20.00% 20.00%

Publicador:

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Adhesive bonding is a viable technique for joining a wide range of materials. However, increasing the lifetime, reducing the costs, and improving the safety of structures are highly demanded nowadays. Hence, the development of new technologies and processes for easy recycle, heal, or self-heal of bonded structures are becoming of great interest for the industry. This paper provides an overview of the current developments in the use of “smart” adhesive technology and introduces the reader to early findings on the use of self-healing materials, thermally expandable particles, and nanoparticles, among others, in adhesives and their potential to increase the reliability of adhesive joints.