951 resultados para measurement data


Relevância:

40.00% 40.00%

Publicador:

Resumo:

A quadcopter is a helicopter with four rotors, which is mechanically simple device, but requires complex electrical control for each motor. Control system needs accurate information about quadcopter’s attitude in order to achieve stable flight. The goal of this bachelor’s thesis was to research how this information could be obtained. Literature review revealed that most of the quadcopters, whose source-code is available, use a complementary filter or some derivative of it to fuse data from a gyroscope, an accelerometer and often also a magnetometer. These sensors combined are called an Inertial Measurement Unit. This thesis focuses on calculating angles from each sensor’s data and fusing these with a complementary filter. On the basis of literature review and measurements using a quadcopter, the proposed filter provides sufficiently accurate attitude data for flight control system. However, a simple complementary filter has one significant drawback – it works reliably only when the quadcopter is hovering or moving at a constant speed. The reason is that an accelerometer can’t be used to measure angles accurately if linear acceleration is present. This problem can be fixed using some derivative of a complementary filter like an adaptive complementary filter or a Kalman filter, which are not covered in this thesis.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Chongqing is the largest central-government-controlled municipality in China, which is now under going a rapid urbanization. The question remains open: What are the consequences of such rapid urbanization in Chongqing in terms of urban microclimates? An integrated study comprising three different research approaches is adopted in the present paper. By analyzing the observed annual climate data, an average rising trend of 0.10◦C/decade was found for the annual mean temperature from 1951 to 2010 in Chongqing,indicating a higher degree of urban warming in Chongqing. In addition, two complementary types of field measurements were conducted: fixed weather stations and mobile transverse measurement. Numerical simulations using a house-developed program are able to predict the urban air temperature in Chongqing.The urban heat island intensity in Chongqing is stronger in summer compared to autumn and winter.The maximum urban heat island intensity occurs at around midnight, and can be as high as 2.5◦C. In the day time, an urban cool island exists. Local greenery has a great impact on the local thermal environment.Urban green spaces can reduce urban air temperature and therefore mitigate the urban heat island. The cooling effect of an urban river is limited in Chongqing, as both sides of the river are the most developed areas, but the relative humidity is much higher near the river compared with the places far from it.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Measurement error models often arise in epidemiological and clinical research. Usually, in this set up it is assumed that the latent variable has a normal distribution. However, the normality assumption may not be always correct. Skew-normal/independent distribution is a class of asymmetric thick-tailed distributions which includes the Skew-normal distribution as a special case. In this paper, we explore the use of skew-normal/independent distribution as a robust alternative to null intercept measurement error model under a Bayesian paradigm. We assume that the random errors and the unobserved value of the covariate (latent variable) follows jointly a skew-normal/independent distribution, providing an appealing robust alternative to the routine use of symmetric normal distribution in this type of model. Specific distributions examined include univariate and multivariate versions of the skew-normal distribution, the skew-t distributions, the skew-slash distributions and the skew contaminated normal distributions. The methods developed is illustrated using a real data set from a dental clinical trial. (C) 2008 Elsevier B.V. All rights reserved.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

We measure the dimuon charge asymmetry A in p (p) over bar collisions at a center of mass energy root s=1960 GeV. The data was recorded with the D0 detector and corresponds to an integrated luminosity of approximately 1.0 fb(-1). Assuming that the asymmetry A is due to asymmetric B-0 <->(B) over bar (0) mixing and decay, we extract the CP-violation parameter of B-0 mixing and decay: ((epsilon B0))/(1+vertical bar epsilon B0 vertical bar 2)=(AB0)/(4)= -0.0023 +/- 0.0011(stat)+/- 0.0008(syst).A(B)(0) is the dimuon charge asymmetry from decays of B-0(B) over bar (0) pairs. The general case, with CP violation in both B-0 and B-s(0) systems, is also considered. Finally we obtain the forward-backward asymmetry that quantifies the tendency of mu(+) to go in the proton direction and mu(-) to go in the antiproton direction. The results are consistent with the standard model and constrain new physics.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Includes bibliography

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Includes bibliography

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Includes bibliography

Relevância:

40.00% 40.00%

Publicador:

Resumo:

This study aimed to assess measurements of temperature and relative humidity obtained with HOBO a data logger, under various conditions of exposure to solar radiation, comparing them with those obtained through the use of a temperature/relative humidity probe and a copper-constantan thermocouple psychrometer, which are considered the standards for obtaining such measurements. Data were collected over a 6-day period (from 25 March to 1 April, 2010), during which the equipment was monitored continuously and simultaneously. We employed the following combinations of equipment and conditions: a HOBO data logger in full sunlight; a HOBO data logger shielded within a white plastic cup with windows for air circulation; a HOBO data logger shielded within a gill-type shelter (multi-plate prototype plastic); a copper-constantan thermocouple psychrometer exposed to natural ventilation and protected from sunlight; and a temperature/relative humidity probe under a commercial, multi-plate radiation shield. Comparisons between the measurements obtained with the various devices were made on the basis of statistical indicators: linear regression, with coefficient of determination; index of agreement; maximum absolute error; and mean absolute error. The prototype multi-plate shelter (gill-type) used in order to protect the HOBO data logger was found to provide the best protection against the effects of solar radiation on measurements of temperature and relative humidity. The precision and accuracy of a device that measures temperature and relative humidity depend on an efficient shelter that minimizes the interference caused by solar radiation, thereby avoiding erroneous analysis of the data obtained.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Evaluations of measurement invariance provide essential construct validity evidence. However, the quality of such evidence is partly dependent upon the validity of the resulting statistical conclusions. The presence of Type I or Type II errors can render measurement invariance conclusions meaningless. The purpose of this study was to determine the effects of categorization and censoring on the behavior of the chi-square/likelihood ratio test statistic and two alternative fit indices (CFI and RMSEA) under the context of evaluating measurement invariance. Monte Carlo simulation was used to examine Type I error and power rates for the (a) overall test statistic/fit indices, and (b) change in test statistic/fit indices. Data were generated according to a multiple-group single-factor CFA model across 40 conditions that varied by sample size, strength of item factor loadings, and categorization thresholds. Seven different combinations of model estimators (ML, Yuan-Bentler scaled ML, and WLSMV) and specified measurement scales (continuous, censored, and categorical) were used to analyze each of the simulation conditions. As hypothesized, non-normality increased Type I error rates for the continuous scale of measurement and did not affect error rates for the categorical scale of measurement. Maximum likelihood estimation combined with a categorical scale of measurement resulted in more correct statistical conclusions than the other analysis combinations. For the continuous and censored scales of measurement, the Yuan-Bentler scaled ML resulted in more correct conclusions than normal-theory ML. The censored measurement scale did not offer any advantages over the continuous measurement scale. Comparing across fit statistics and indices, the chi-square-based test statistics were preferred over the alternative fit indices, and ΔRMSEA was preferred over ΔCFI. Results from this study should be used to inform the modeling decisions of applied researchers. However, no single analysis combination can be recommended for all situations. Therefore, it is essential that researchers consider the context and purpose of their analyses.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

The scope of this study was to estimate calibrated values for dietary data obtained by the Food Frequency Questionnaire for Adolescents (FFQA) and illustrate the effect of this approach on food consumption data. The adolescents were assessed on two occasions, with an average interval of twelve months. In 2004, 393 adolescents participated, and 289 were then reassessed in 2005. Dietary data obtained by the FFQA were calibrated using the regression coefficients estimated from the average of two 24-hour recalls (24HR) of the subsample. The calibrated values were similar to the the 24HR reference measurement in the subsample. In 2004 and 2005 a significant difference was observed between the average consumption levels of the FFQA before and after calibration for all nutrients. With the use of calibrated data the proportion of schoolchildren who had fiber intake below the recommended level increased. Therefore, it is seen that calibrated data can be used to obtain adjusted associations due to reclassification of subjects within the predetermined categories.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Determination of the utility harmonic impedance based on measurements is a significant task for utility power-quality improvement and management. Compared to those well-established, accurate invasive methods, the noninvasive methods are more desirable since they work with natural variations of the loads connected to the point of common coupling (PCC), so that no intentional disturbance is needed. However, the accuracy of these methods has to be improved. In this context, this paper first points out that the critical problem of the noninvasive methods is how to select the measurements that can be used with confidence for utility harmonic impedance calculation. Then, this paper presents a new measurement technique which is based on the complex data-based least-square regression, combined with two techniques of data selection. Simulation and field test results show that the proposed noninvasive method is practical and robust so that it can be used with confidence to determine the utility harmonic impedances.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

In questionable cystic fibrosis (CF), mild or monosymptomatic phenotypes frequently cause diagnostic difficulties despite detailed algorithms. CF transmembrane conductance regulator (CFTR)-mediated ion transport can be studied ex vivo in rectal biopsies by intestinal current measurement (ICM).