993 resultados para magnetic measurement


Relevância:

30.00% 30.00%

Publicador:

Resumo:

Risers are flexible multilayered pipes formed by an inner flexible metal structure surrounded by polymer layers and spiral wound steel ligaments, also known as armor wires. Since these risers are used to link subsea pipelines to floating oil and gas production installations, and their failure could produce catastrophic consequences, some methods have been proposed to monitor the armor integrity. However, until now there is no practical method that allows the automatic non-destructive detection of individual armor wire rupture. In this work we show a method using magnetic Barkhausen noise that has shown high efficiency in the detection of armor wire rupture. The results are examined under the cyclic and static load conditions of the riser. This work also analyzes the theory behind the singular dependence of the magnetic Barkhausen noise on the applied tension in riser armor wires.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Increased, decreased or normal excitability to transcranial magnetic stimulation (TMS) has been reported in the motor (M1) and visual cortices of patients with migraine. Light deprivation (LD) has been reported to modulate M1 excitability in control subjects (CS). Still, effects of LD on M1 excitability compared to exposure to environmental light exposure (EL) had not been previously described in patients with migraine (MP). To further our knowledge about differences between CS and MP, regarding M1 excitability and effects of LD on M1 excitability, we opted for a novel approach by extending measurement conditions. We measured motor thresholds (MTs) to TMS, short-interval intracortical inhibition, and ratios between motor-evoked potential amplitudes and supramaximal M responses in MP and CS on two different days, before and after LD or EL. Motor thresholds significantly increased in MP in LD and EL sessions, and remained stable in CS. There were no significant between-group differences in other measures of TMS. Short-term variation of MTs was greater in MP compared to CS. Fluctuation in excitability over hours or days in MP is an issue that, until now, has been relatively neglected. The results presented here will help to reconcile conflicting observations.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

OBJECTIVE: To evaluate tools for the fusion of images generated by tomography and structural and functional magnetic resonance imaging. METHODS: Magnetic resonance and functional magnetic resonance imaging were performed while a volunteer who had previously undergone cranial tomography performed motor and somatosensory tasks in a 3-Tesla scanner. Image data were analyzed with different programs, and the results were compared. RESULTS: We constructed a flow chart of computational processes that allowed measurement of the spatial congruence between the methods. There was no single computational tool that contained the entire set of functions necessary to achieve the goal. CONCLUSION: The fusion of the images from the three methods proved to be feasible with the use of four free-access software programs (OsiriX, Register, MRIcro and FSL). Our results may serve as a basis for building software that will be useful as a virtual tool prior to neurosurgery.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Myocardial perfusion quantification by means of Contrast-Enhanced Cardiac Magnetic Resonance images relies on time consuming frame-by-frame manual tracing of regions of interest. In this Thesis, a novel automated technique for myocardial segmentation and non-rigid registration as a basis for perfusion quantification is presented. The proposed technique is based on three steps: reference frame selection, myocardial segmentation and non-rigid registration. In the first step, the reference frame in which both endo- and epicardial segmentation will be performed is chosen. Endocardial segmentation is achieved by means of a statistical region-based level-set technique followed by a curvature-based regularization motion. Epicardial segmentation is achieved by means of an edge-based level-set technique followed again by a regularization motion. To take into account the changes in position, size and shape of myocardium throughout the sequence due to out of plane respiratory motion, a non-rigid registration algorithm is required. The proposed non-rigid registration scheme consists in a novel multiscale extension of the normalized cross-correlation algorithm in combination with level-set methods. The myocardium is then divided into standard segments. Contrast enhancement curves are computed measuring the mean pixel intensity of each segment over time, and perfusion indices are extracted from each curve. The overall approach has been tested on synthetic and real datasets. For validation purposes, the sequences have been manually traced by an experienced interpreter, and contrast enhancement curves as well as perfusion indices have been computed. Comparisons between automatically extracted and manually obtained contours and enhancement curves showed high inter-technique agreement. Comparisons of perfusion indices computed using both approaches against quantitative coronary angiography and visual interpretation demonstrated that the two technique have similar diagnostic accuracy. In conclusion, the proposed technique allows fast, automated and accurate measurement of intra-myocardial contrast dynamics, and may thus address the strong clinical need for quantitative evaluation of myocardial perfusion.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Materialen mit sehr hoher Spinpolarisation werden für Anwendungen im Bereich der Spin-Elektronik benötigt. Deshalb werden große Forschungsanstrengungen zur Untersuchung der Eigenschaften von Verbindungen mit potentiell halbmetallischem Charakter, d. h.mit 100% Spinpolarisation, unternommen. In halbmetallischen Verbindungen, erwartet man eine Lücke in der Zustandsdichte an der Fermi Energie für Ladungsträger einer Spinrichtung, wahrend die Ladungsträger mit der anderen Spinrichtung sich metallisch verhalten. Eine Konsequenz davon ist, dass ein Strom, der durch solche Verbindung fließt, voll spinpolarisiert ist. Die hohe Curie-Temperatur Tc (800 K) und der theoretisch vorhergesagte halbmetallische Charakter machen Co2Cr0.6Fe0.4Al (CCFA) zu einem guten Kandidaten für Spintronik-Anwendungen wie magnetische Tunnelkontakte (MTJs = Magnetic Tunneling Junctions). In dieser Arbeit werden die Ergebnisse der Untersuchung der elektronischen und strukturellen Eigenschaften von dünnen CCFA Schichten dargestellt. Diese Schichten wurden in MTJs integriert und der Tunnel-Magnetowiderstands-Effekt untersucht. Hauptziele waren die Messung der Spinpolarisation und Untersuchungen der elektronischen Struktur von CCFA. Der Einfluss verschiedener Depositionsparameter auf die Eigenschaften der Schichten, speziell auf der Oberflächenordnung und damit letztlich auf den Tunnel-Magnetowiderstand (TMR), wurde bestimmt. Epitaktische d¨unne CCFA Schichten mit zwei verschiedenen Wachstumsrichtungen wurden auf verschiedene Substrate und Pufferschichten deponiert. Ein Temperverfahren wurde eingesetzt um die strukturelle Eigenschaften der dünnen Schichten zu verbessern. Für die MTJs wurde Al2O3 als Barrierenmaterial verwendet und Co als Gegenelektrode gewählt. Die Mehrschicht-Systeme wurden in Mesa-Geometrie mit lithographischen Methoden strukturiert. Eine maximal Jullière Spinpolarisation von 54% wurde an Tunnelkontakte mit epitaktischen CCFA Schichten gemessen. Ein starker Einfluss der Tempernbedingungen auf dem TMR wurde festgestellt. Eine Erhörung des TMR wurde mit einer Verbesserung der Oberflächenordung der CCFA Schichten korreliert. Spektroskopische Messungen wurden an den MTJs durchgeführt. Diesen Messungen liefern Hinweise auf inelastische Elektron-Magnon und Elektron-Phonon Stossprozesse an den Grenzflächen. Einige der beobachteten Strukturen konnten mit der berechneten elektronischen Struktur von CCFA korreliert worden.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The international growing concern for the human exposure to magnetic fields generated by electric power lines has unavoidably led to imposing legal limits. Respecting these limits, implies being able to calculate easily and accurately the generated magnetic field also in complex configurations. Twisting of phase conductors is such a case. The consolidated exact and approximated theory regarding a single-circuit twisted three-phase power cable line has been reported along with the proposal of an innovative simplified formula obtained by means of an heuristic procedure. This formula, although being dramatically simpler, is proven to be a good approximation of the analytical formula and at the same time much more accurate than the approximated formula found in literature. The double-circuit twisted three-phase power cable line case has been studied following different approaches of increasing complexity and accuracy. In this framework, the effectiveness of the above-mentioned innovative formula is also examined. The experimental verification of the correctness of the twisted double-circuit theoretical analysis has permitted its extension to multiple-circuit twisted three-phase power cable lines. In addition, appropriate 2D and, in particularly, 3D numerical codes for simulating real existing overhead power lines for the calculation of the magnetic field in their vicinity have been created. Finally, an innovative ‘smart’ measurement and evaluation system of the magnetic field is being proposed, described and validated, which deals with the experimentally-based evaluation of the total magnetic field B generated by multiple sources in complex three-dimensional arrangements, carried out on the basis of the measurement of the three Cartesian field components and their correlation with the field currents via multilinear regression techniques. The ultimate goal is verifying that magnetic induction intensity is within the prescribed limits.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Wearable inertial and magnetic measurements units (IMMU) are an important tool for underwater motion analysis because they are swimmer-centric, they require only simple measurement set-up and they provide the performance results very quickly. In order to estimate 3D joint kinematics during motion, protocols were developed to transpose the IMMU orientation estimation to a biomechanical model. The aim of the thesis was to validate a protocol originally propositioned to estimate the joint angles of the upper limbs during one-degree-of-freedom movements in dry settings and herein modified to perform 3D kinematics analysis of shoulders, elbows and wrists during swimming. Eight high-level swimmers were assessed in the laboratory by means of an IMMU while simulating the front crawl and breaststroke movements. A stereo-photogrammetric system (SPS) was used as reference. The joint angles (in degrees) of the shoulders (flexion-extension, abduction-adduction and internal-external rotation), the elbows (flexion-extension and pronation-supination), and the wrists (flexion-extension and radial-ulnar deviation) were estimated with the two systems and compared by means of root mean square errors (RMSE), relative RMSE, Pearson’s product-moment coefficient correlation (R) and coefficient of multiple correlation (CMC). Subsequently, the athletes were assessed during pool swimming trials through the IMMU. Considering both swim styles and all joint degrees of freedom modeled, the comparison between the IMMU and the SPS showed median values of RMSE lower than 8°, representing 10% of overall joint range of motion, high median values of CMC (0.97) and R (0.96). These findings suggest that the protocol accurately estimated the 3D orientation of the shoulders, elbows and wrists joint during swimming with accuracy adequate for the purposes of research. In conclusion, the proposed method to evaluate the 3D joint kinematics through IMMU was revealed to be a useful tool for both sport and clinical contexts.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

One of the most precisely measured quantities in particle physics is the magnetic moment of the muon, which describes its coupling to an external magnetic field. It is expressed in form of the anomalous magnetic moment of the muon a_mu=(g_mu-2)/2 and has been determined experimentally with a precision of 0.5 parts per million. The current direct measurement and the theoretical prediction of the standard model differ by more than 3.5 standard deviations. Concerning theory, the contribution of the QED and weak interaction to a_mu can be calculated with very high precision in a perturbative approach.rnAt low energies, however, perturbation theory cannot be used to determine the hadronic contribution a^had_mu. On the other hand, a^had_mu may be derived via a dispersion relation from the sum of measured cross sections of exclusive hadronic reactions. Decreasing the experimental uncertainty on these hadronic cross sections is of utmost importance for an improved standard model prediction of a_mu.rnrnIn addition to traditional energy scan experiments, the method of Initial State Radiation (ISR) is used to measure hadronic cross sections. This approach allows experiments at colliders running at a fixed centre-of-mass energy to access smaller effective energies by studying events which contain a high-energetic photon emitted from the initial electron or positron. Using the technique of ISR, the energy range from threshold up to 4.5GeV can be accessed at Babar.rnrnThe cross section e+e- -> pi+pi- contributes with approximately 70% to the hadronic part of the anomalous magnetic moment of the muon a_mu^had. This important channel has been measured with a precision of better than 1%. Therefore, the leading contribution to the uncertainty of a_mu^had at present stems from the invariant mass region between 1GeV and 2GeV. In this energy range, the channels e+e- -> pi+pi-pi+pi- and e+e- -> pi+pi-pi0pi0 dominate the inclusive hadronic cross section. The measurement of the process e+e- -> pi+pi-pi+pi- will be presented in this thesis. This channel has been previously measured by Babar based on 25% of the total dataset. The new analysis includes a more detailed study of the background contamination from other ISR and non-radiative background reactions. In addition, sophisticated studies of the track reconstruction as well as the photon efficiency difference between the data and the simulation of the Babar detector are performed. With these auxiliary studies, a reduction of the systematic uncertainty from 5.0% to 2.4% in the peak region was achieved.rnrnThe pi+pi-pi+pi- final state has a rich internal structure. Hints are seen for the intermediate states rho(770)^0 f_2(1270), rho(770)^0 f_0(980), as well as a_1(1260)pi. In addition, the branching ratios BR(jpsi -> pi+pi-pi+pi-) and BR(psitwos -> jpsi pi+pi-) are extracted.rn

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The future goal of modern physics is the discovery of physics beyond the Standard Model. One of the most significant hints for New Physics can be seen in the anomalous magnetic moment of the muon - one of the most precise measured variables in modern physics and the main motivation of this work. This variable is associated with the coupling of the muon, an elementary particle, to an external electromagnetic field and is defined as a = (g - 2)/2, whereas g is the gyromagnetic factor of the muon. The muon anomaly has been measured with a relative accuracy of 0.5·10-6. However, a difference between the direct measurement and the Standard Model prediction of 3.6 standard deviations can be observed. This could be a hint for the existence of New Physics. Unfortunately, it is, yet, not significant enough to claim an observation and, thus, more precise measurements and calculations have to be performed.rnThe muon anomaly has three contributions, whereas the ones from quantum electrodynamics and weak interaction can be determined from perturbative calculations. This cannot be done in case of the hadronic contributions at low energies. The leading order contribution - the hadronic vacuum polarization - can be computed via a dispersion integral, which needs as input hadronic cross section measurements from electron-positron annihilations. Hence, it is essential for a precise prediction of the muon anomaly to measure these hadronic cross sections, σ(e+e-→hadrons), with high accuracy. With a contribution of more than 70%, the final state containing two charged pions is the most important one in this context.rnIn this thesis, a new measurement of the σ(e+e-→π+π-) cross section and the pion form factor is performed with an accuracy of 0.9% in the dominant ρ(770) resonance region between 600 and rn900 MeV at the BESIII experiment. The two-pion contribution to the leading-order (LO) hadronic vacuum polarization contribution to (g - 2) from the BESIII result, obtained in this work, is computed to be a(ππ,LO,600-900 MeV) = (368.2±2.5stat±3.3sys)·10-10. With the result presented in this thesis, we make an important contribution on the way to solve the (g - 2) puzzle.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

OBJECTIVE: The aim of this study was to assess the glycosaminoglycan (GAG) content in hip joint cartilage in mature hips with a history of slipped capital femoral epiphysis (SCFE) using delayed gadolinium-enhanced MRI of cartilage (dGEMRIC). METHODS: 28 young-adult subjects (32 hips) with a mean age of 23.8+/-4.0 years (range: 18.1-30.5 years) who were treated for mild or moderate SCFE in adolescence were included into the study. Hip function and clinical symptoms were evaluated with the Harris hip score (HHS) system at the time of MRI. Plain radiographic evaluation included Tonnis grading, measurement of the minimal joint space width (JSW) and alpha-angle measurement. The alpha-angle values were used to classify three sub-groups: group 1=subjects with normal femoral head-neck offset (alpha-angle <50 degrees ), group 2=subjects with mild offset decrease (alpha-angle 50 degrees -60 degrees ), and group 3=subjects with severe offset decrease (alpha-angle >60 degrees ). RESULTS: There was statistically significant difference noted for the T1(Gd) values, lateral and central, between group 1 and group 3 (p-values=0.038 and 0.041). The T1(Gd) values measured within the lateral portion were slightly lower compared with the T1(Gd) values measured within the central portion that was at a statistically significance level (p-value <0.001). HHS, Tonnis grades and JSW revealed no statistically significant difference. CONCLUSION: By using dGEMRIC in the mid-term follow-up of SCFE we were able to reveal degenerative changes even in the absence of joint space narrowing that seem to be related to the degree of offset pathology. The dGEMRIC technique may be a potential diagnostic modality in the follow-up evaluation of SCFE.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

To evaluate whether it is feasible to measure the segmental flux of small bowel content using MR phase-contrast (PC) pulse sequences.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Evaluation of a novel non-invasive tool for postoperative follow-up of patients postelective saphenous vein coronary artery bypass graft (CABG) was performed. Ten patients were included. Their bypass grafts supplied the right coronary artery (7), marginal branches (1), diagonal branches (2), and the circumflex artery (n=1). Each bypass was examined intraoperatively using Doppler flow measurement. Patients were examined with a 3-Tesla magnetic resonance imaging (MRI) scanner (MAGNETOM Verio, Siemens, Erlangen, Germany) within one week postsurgery using MR-angiography with an intravasal contrast agent and velocity encoded phase-contrast flow measurements. Intraoperative Doppler flow measurements revealed regular flow patterns in all vascular territories supplied. The median intraoperative flow rate was 50 ml/min with an inter-quartile range (IQR) of 42-70 ml/min. The clinical postoperative course was uneventful. MRI showed all grafts to be patent. The median postoperative flow rate was 50 ml/min (IQR: 32-65 ml/min). MRI flow rates agreed well with intraoperative Doppler flow measurements (mean difference: -2.8±20.1 ml/min). This initial study demonstrates that 3-Tesla MRI flow measurements correlated well with Doppler thus reconfirming the graft patency postCABG. Further refinement and broader application of this technique may facilitate follow-up postCABG potentially replacing empiric clinical judgment by reliable non-invasive imaging.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Right ventricular (RV) systolic function is prognostically important, but its assessment by echocardiography remains challenging, in part because of the multitude of available measurement methods. The purpose of this prospective study was to rank these methods against the reference of RV ejection fraction (EF) as obtained in a broad clinical population by magnetic resonance imaging (MRI).

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Auditory hallucinations comprise a critical domain of psychopathology in schizophrenia. Repetitive transcranial magnetic stimulation (TMS) has shown promise as an intervention with both positive and negative reports. The aim of this study was to test resting-brain perfusion before treatment as a possible biological marker of response to repetitive TMS. Twenty-four medicated patients underwent resting-brain perfusion magnetic resonance imaging with arterial spin labeling (ASL) before 10 days of repetitive TMS treatment. Response was defined as a reduction in the hallucination change scale of at least 50%. Responders (n=9) were robustly differentiated from nonresponders (n=15) to repetitive TMS by the higher regional cerebral blood flow (CBF) in the left superior temporal gyrus (STG) (P<0.05, corrected) before treatment. Resting-brain perfusion in the left STG predicted the response to repetitive TMS in this study sample, suggesting this parameter as a possible bio-marker of response in patients with schizophrenia and auditory hallucinations. Being noninvasive and relatively easy to use, resting perfusion measurement before treatment might be a clinically relevant way to identify possible responders and nonresponders to repetitive TMS.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

OBJECTIVES: To assess influence of durotomy on spinal cord blood flow (SCBF) in chondrodystrophic dogs with thoracolumbar disk extrusion. STUDY DESIGN: Prospective cohort study. ANIMALS: Chondrodystrophic dogs with thoracolumbar disk extrusion (n = 11). METHODS: Diagnosis was based on neurologic signs, magnetic resonance imaging (MRI) findings, and surgical confirmation. Regional SCBF was measured 3 times intraoperatively by laser-Doppler flowmetry: (1) before surgical decompression; (2) immediately after decompression by hemilaminectomy-durotomy; and (3) after 15 minutes of lesion lavage. A standardized hemilaminectomy and durotomy performed by the same neurosurgeon, was used to minimize factors that could influence measurement readings. RESULTS: A significant increase in intraoperative SCBF was found immediately after spinal cord decompression and durotomy in dogs but SCBF returned to previous levels or lower after 15 minutes of lavage. Changes in SCBF were not associated with duration of clinical signs; neurologic status, degree of spinal cord compression, or signal intensity changes as assessed by MRI. CONCLUSION: Durotomy does not increase SCBF in dogs with disk extrusion associated spinal cord compression.