421 resultados para magnet


Relevância:

10.00% 10.00%

Publicador:

Resumo:

Modulation and control of a cascade multilevel inverter, which has a high potential in future wind generation applications, are presented. The inverter is a combination of a high power, three level “bulk inverter” and a low power “conditioning inverter”. To minimize switching losses, the bulk inverter operates at a low frequency producing square wave outputs while high frequency conditioning inverter is used to suppress harmonic content produced by the bulk inverter output. This paper proposes an improved Space Vector Modulation (SVM) algorithm and a neutral point potential balancing technique for the inverter. Furthermore, a maximum power tracking controller for the Permanent Magnet Synchronous Generator (PMSG) is described in detail. The proposed SVM technique eliminates most of the computational burdens on the digital controller and renders a greater controllability under varying DC-link voltage conditions. The DC-link capacitor voltage balancing of both bulk and conditioning inverters is carried out using Redundant State Selection (RSS) method and is explained in detail. Experimental results are presented to verify the proposed modulation and control techniques.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A field oriented control (FOC) algorithm is simulated and implemented for use with a permanent magnet synchronous motor (PMSM). Rotor position is sensed using Hall effect switches on the stator because other hardware position sensors attached to the rotor may not be desirable or cost effective for certain applications. This places a limit on the resolution of position sensing – only a few Hall effect switches can be placed. In this simulation, three sensors are used and the position information is obtained at higher resolution by estimating it from the rotor dynamics, as shown in literature previously. This study compares the performance of the method with an incremental encoder using simulations. The FOC algorithm is implemented using Digital Motor Control (DMC) and IQ Texas Instruments libraries from a Simulink toolbox called Embedded Coder, and downloaded into a TI microcontroller (TMS320F28335) known as the Piccolo via Code Composer Studio (CCS).

Relevância:

10.00% 10.00%

Publicador:

Resumo:

In a book seeking to redraw the boundaries between interdisciplinary and transnational modernisms, this chapter contributes to the reorientation in modernist studies by revisiting "primitivism." While no one freely identifies as “primitive,” the spectre of primitivism was a magnet of attraction as well as of critical refusal. It resided on the knife-edge of envy and denunciation, as well as for the projection of alternate imaginative utopias and the worst forms of racial chauvinism. This chapter asserts that primitivism endures as a provocation as much as a utopian aspiration, but it also provides a different understanding of cultures on the "periphery", which is how Antipodean art history has understood itself. The spectre of primitivism not only amplifies the quandaries of modernist cultures—both alerting one to the aesthetic alternatives to modernist cultures, yet also highlighting the fate of traditional culture pitted against modernist cultures, it also suggests the quandaries of a peripheral modernity.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Demagnetization to zero remanent value or to a predetermined value is of interest to magnet manufacturers and material users. Conventional methods of demagnetization using a varying alternating demagnetizing field, under a damped oscillatory or conveyor system, result in either high cost for demagnetization or large power dissipation. A simple technique using thyristors is presented for demagnetizing the material. Power consumption is mainly in the first two half-cycles of applied voltage. Hence power dissipation is very much reduced. An optimum value calculation for a thyristor triggering angle for demagnetizing high coercive materials is also presented.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A low cost 12 T pulsed magnet system has been integrated with a closed-cycle helium refrigerator. The copper solenoid is directly immersed in liquid nitrogen for reduced electrical resistance and more efficient heat transfer. This ensures a minimal delay of few minutes between pulses. The sample is mounted on the cold finger of the refrigerator and, along with the surrounding vacuum shroud, is inserted into the bore of the solenoid. When combined with software lock-in signal processing to reduce noise, quick but accurate measurements can be performed at temperatures 4 K-300 K up to 12 T. Quantum Hall effect data in a p-channel SiGe/Si heterostructure has been used to calibrate the instrument against a commercial superconducting magnet. Its versatility as a routine characterization tool is demonstrated bymeasuring parallel conduction in Si/SiGe modulation doped heterostructures.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This project has delivered outcomes that address major agronomic and crop protection issues closely linked to the profitability and sustainability of cotton production enterprises in CQ. From an agronomic perspective, the CQ environment was always though to support economically viable cotton production in a wide sowing window from the middle of September to early January prior to this research. The ideal positioning of Bollgard II varieties in the CQ planting window was, therefore, critical to the future of the local cotton industry because growers needed baseline information to determine how best to take advantage of the higher yield potential offered by the Bt cotton technology, optimise irrigation water use and fibre characteristics. The project’s outputs include a number of key agronomic findings. Over three growing seasons, Bollgard II crop planted in the traditional sowing window from the middle of September to the end of October consistently produced the highest yields. The project delivers a clear and quantitative assessment of the impacts of planting outside the traditional cropping window - a yield penalty of between 1-4 bales/ha for November and December planted cotton. Whilst yield penalties associated with December-planted crops are clearly linked to declining heat units in the second half of the crop and a cool finish, those associated with November-planted cotton are not consistent with the theoretical yield potential for this sowing date. Further research to understand and minimize the physiological constraints on November-planted cotton would give CQ cotton growers far greater flexibility to develop mixed/double/rotation cropping farming systems that are relevant to the rapidly evolving nature of Agricultural production in Australia. The equivalence of cultivar types with clearly distinguishable, genetically based growth habits, demonstrated in this project, gives growers important information for making varietal choices. The entomological outcomes of this project represent strategic and tactical tools that are highly relevant to the viability and profitability of the cotton industry in Australia. The future of the cotton industry is inextricably linked to the survival and efficacy of GM cotton. Research done in the Callide irrigation area demonstrates the unquestionable potential for development of alternative and highly effective resistance management strategies for Bollgard II using novel technologies and strategies based on products such as Magnet®. Magnet® and similar technologies will be increasingly important in strategies to preserve the shelf life and efficacy of current and future generations of GM technology. However, more research will be required to address logistical and operational issues related to these new technologies before they can be fully exploited in commercial production systems. From an economic perspective, SLW is the sleeping giant in terms of insect nemeses of cotton, particularly from the standpoint of climate change and an increasingly warmer production environment. An effective sampling and management strategy for SLW which has been delivered by this project will go a long way towards minimising production costs in an environment characterised by rapidly rising input costs. SLW has the potential to permanently debilitate the national cotton industry by influencing market sentiment and quality perceptions. Field validation of the SLW population sampling models and management options in the Dawson irrigation area cotton and southern Queensland during 2006-07 documents the robustness of the entomological research outcomes achieved through this project.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

We review here research on semiochemicals for cotton pest management carried out in successive Cotton Co-operative Research Centres from 1998 to 2012. Australian cotton is now dominated by transgenic (Bt) varieties, which provide a strong platform for integrated pest management of key pests such as Helicoverpa spp., but new technologies are required to manage the development of resistance in Helicoverpa spp. to transgenic cotton and the problems posed by emerging and secondary pests, especially sucking insects. A long-range attractant for Helicoverpa moths, based on plant volatiles, has been commercialised as Magnet®. The product has substantial area-wide impacts on moth populations, and only limited effects on beneficial insects. Potential roles are being investigated for this product in resistance management of Helicoverpa spp. on transgenic cotton. Short-range, non-volatile compounds on organ surfaces of plants that do not support development of Helicoverpa spp. have been identified; these compounds deter feeding or oviposition, or are toxic to insect pests. One such product, Sero X®, is effective on Helicoverpa spp. and sucking pests such as whiteflies (Bemisia tabaci), green mirids (Creontiades dilutus), and other hemipteran insects, and is in the advanced stages of commercialisation.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

ZLI-1167 is a ternary mixture of nematic liquid crystals with negative diamagnetic anisotropy. It has, therefore, been used as a solvent where the spinning of the samples around the vertical axis in the conventional electromagnets without destroying the orientation of the dissolved molecules is possible in NMR experiments. This results in sharp lines with widths up to 1 Hz in the spectra.1,2 In an NMR system using a superconducting magnet (where the magnetic field direction is along the axis of spinning of the sample), it is possible to use even the nematic liquid crystals with positive diamagnetic anisotropy such as N-(p'-methoxybenzylidene)-p-n-butylaniline (MBBA) or N-(p'-ethoxybenzylidene)-p-n-butylaniline (EBBA) to obtain the spectra with sample spinning with equally sharp lines.3 The orientational behaviour of the dissolved molecules as a function of relative concentrations of the two solvents is investigated and the results are reported in the present communication.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

ALICE (A Large Ion Collider Experiment) is the LHC (Large Hadron Collider) experiment devoted to investigating the strongly interacting matter created in nucleus-nucleus collisions at the LHC energies. The ALICE ITS, Inner Tracking System, consists of six cylindrical layers of silicon detectors with three different technologies; in the outward direction: two layers of pixel detectors, two layers each of drift, and strip detectors. The number of parameters to be determined in the spatial alignment of the 2198 sensor modules of the ITS is about 13,000. The target alignment precision is well below 10 micron in some cases (pixels). The sources of alignment information include survey measurements, and the reconstructed tracks from cosmic rays and from proton-proton collisions. The main track-based alignment method uses the Millepede global approach. An iterative local method was developed and used as well. We present the results obtained for the ITS alignment using about 10^5 charged tracks from cosmic rays that have been collected during summer 2008, with the ALICE solenoidal magnet switched off.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Ion implantation systems, used for producing high-current ion beams, employ wide-beam ion sources which are rotated through 90 degrees . These sources need mass analyser optics which are different from the conventional design. The authors present results of calculation of the image distance as a function of entrance and exit angles of a sector magnet mass analyser having such a source. These computations have been performed for the magnetic deflection angles 45 degrees , 60 degrees and 90 degrees . The details of the computations carried out using the computer program MODBEAM, developed for this purpose, are also discussed.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Dehydrogenation of ammonia borane was carried out in fluor alcohol solvent in order to obtain compounds that are more likely candidates suitable for regeneration. Even though ammonia borane undergoes self-dissociation in 2,2,2-trifluoroethanol to liberate H-2, decent hydrogen release rates were obtained by using Co-Co2B, Ni-Ni3B, and Co-Ni-B nanocomposites as catalysts. These catalysts are magnetic in nature and hence can be separated from the reaction mixture using a magnet for re-use. The final by-product NH4+ B(OCH2CF3)(4)(-) obtained after the catalytic dehydrogenation of ammonia borane was thoroughly characterized using H-1, B-11, and C-13 NMR and IR spectroscopies. The FTIR data showed that the B-O bond in NH4+ B(OCH2CF3)(4)(-) is slightly weaker compared to boric acid. Preliminary investigations on the regenerative routes for ammonia borane from the by-product NH4+ B(OCH2CF3)(4)(-) showed indications of the formation of BNHx species. (C) 2010 Professor T. Nejat Veziroglu. Published by Elsevier Ltd. All rights reserved.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Design, fabrication and preliminary testing of a flat pump with millimetre thickness are described in this paper. The pump is entirely made of polymer materials barring the magnet and copper coils used for electromagnetic actuation. The fabrication is carried out using widely available microelectronic packaging machinery and techniques. Therefore, the fabrication of the pump is straightforward and inexpensive. Two types of prototypes are designed and built. One consists of copper coils that are etched on an epoxy plate and the other has wound insulated wire of 90 mu m diameter to serve as a coil. The overall size of the first pump is 25 mm x 25 mm x 3.6 mm including the 3.1 mm-thick NdFeB magnet of diameter 12 mm. It consists of a pump chamber of 20 mm x 20 mm x 0.8 mm with copper coils etched from a copper-clad epoxy plate using dry-film lithography and milled using a CNC milling machine, two passive valves and the pump-diaphragm made of Kapton film of 0.089 mm thickness. The second pump has an overall size of 35 mm x 35 mm x 4.4 mm including the magnet and the windings. A breadboard circuit and DC power supply are used to test the pump by applying an alternating square-wave voltage pulse. A water slug in a tube attached to the inlet is used to observe and measure the air-flow induced by the pump against atmospheric pressure. The maximum flow rate was found to be 15 ml/min for a voltage of 2.5 V and a current of 19 mA at 68 Hz.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Common water ice (ice I-h) is an unusual solid-the oxygen atoms form a periodic structure but the hydrogen atoms are highly disordered due to there being two inequivalent O-H bond lengths'. Pauling showed that the presence of these two bond lengths leads to a macroscopic degeneracy of possible ground states(2,3), such that the system has finite entropy as the temperature tends towards zero. The dynamics associated with this degeneracy are experimentally inaccessible, however, as ice melts and the hydrogen dynamics cannot be studied independently of oxygen motion(4). An analogous system(5) in which this degeneracy can be studied is a magnet with the pyrochlore structure-termed 'spin ice'-where spin orientation plays a similar role to that of the hydrogen position in ice I-h. Here we present specific-heat data for one such system, Dy2Ti2O7, from which we infer a total spin entropy of 0.67Rln2. This is similar to the value, 0.71Rln2, determined for ice I-h, SO confirming the validity of the correspondence. We also find, through application of a magnetic field, behaviour not accessible in water ice-restoration of much of the ground-state entropy and new transitions involving transverse spin degrees of freedom.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

We drive a d-dimensional Heisenberg magnet using an anisotropic current. The continuum Langevin equation is analysed using a dynamical renormalization group and numerical simulations. We discover a rich steady-state phase diagram, including a critical point in a new nonequilibrium universality class, and a spatiotemporally chaotic phase. The latter may be controlled in a robust manner to target spatially periodic steady states with helical order.