910 resultados para indirect and composite estimators


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Objectives. To verify the hypothesis that crack analysis and a mechanical test would rank a series of composites in a similar order with respect to polymerization stress. Also, both tests would show similar relationships between stress and composite elastic modulus and/or shrinkage. Methods. Soda-lime glass discs (2-mm thick) with a central perforation (3.5-mm diameter) received four Vickers indentations 500 mu m from the cavity margin. The indent cracks were measured (500x) prior and 10 min after the cavity was restored with one of six materials (Kalore/KL, Gradia/GR, Ice/IC, Wave/WV, Majesty Flow/MF, and Majesty Posterior/MP). Stresses at the indent site were calculated based on glass fracture toughness and increase in crack length. Stress at the bonded interface was calculated using the equation for an internally pressurized cylinder. The mechanical test used a universal testing machine and glass rods (5-mm diameter) as substrate. An extensometer monitored specimen height (2 mm). Nominal stress was calculated dividing the maximum shrinkage force by the specimen cross-sectional area. Composite elastic modulus was determined by nanoindentation and post-gel shrinkage was measured using strain gages. Data were subjected to one-way ANOVA/Tukey or Kruskal-Wallis/Mann-Whitney tests (alpha: 5%). Results. Both tests grouped the composites in three statistical subsets, with small differences in overlapping between the intermediate subset (MF, WV) and the highest (MP, IC) or the lowest stress materials (KL, GR). Higher stresses were developed by composites with high modulus and/or high shrinkage. Significance. Crack analysis demonstrated to be as effective as the mechanical test to rank composites regarding polymerization stress. (c) 2012 Academy of Dental Materials. Published by Elsevier Ltd. All rights reserved.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

BACKGROUND: In Brazil nationally representative donor data are limited on human immunodeficiency virus (HIV) prevalence, incidence, and residual transfusion risk. The objective of this study was to analyze HIV data obtained over 24 months by the Retrovirus Epidemiology Donor Study-II program in Brazil. STUDY DESIGN AND METHODS: Donations reactive to third-and fourth-generation immunoassays (IAs) were further confirmed by a less-sensitive (LS) IA algorithm and Western blot (WB). Incidence was calculated for first-time (FT) donors using the LS-EIA results and for repeat donors with a model developed to include all donors with a previous negative donation. Residual risk was projected by multiplying composite FT and repeat donor incidence rates by HIV marker-negative infectious window periods. RESULTS: HIV prevalence among FT donors was 92.2/ 105 donations. FT and repeat donor and composite incidences were 38.5 (95% confidence interval [CI], 25.651.4), 22.5 (95% CI, 17.6-28.0), and 27.5 (95% CI, 22.0-33.0) per 100,000 person-years, respectively. Male and community donors had higher prevalence and incidence rates than female and replacement donors. The estimated residual risk of HIV transfusion transmission was 11.3 per 106 donations (95% CI, 8.4-14.2), which could be reduced to 4.2 per 106 donations (95% CI, 3.2-5.2) by use of individual-donation nucleic acid testing (NAT). CONCLUSION: The incidence and residual transfusion risk of HIV infection are relatively high in Brazil. Implementation of NAT will not be sufficient to decrease transmission rates to levels seen in the United States or Europe; therefore, other measures focused on decreasing donations by at-risk individuals are also necessary.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Objective: To analyze the association between maternal obesity and postnatal infectious complications in high-risk pregnancies. Methods: Prospective study from August 2009 through August 2010 with the following inclusion criteria: women up to the 5th postpartum day; age L 18 years; high-risk pregnancy; singleton pregnancy with live fetus at labor onset; delivery at the institution; maternal weight measured on day of delivery. The nutritional status in late pregnancy was assessed by the body mass index (BMI), with the application of the Atalah et al. curve. Patients were graded as underweight, adequate weight, overweight, or obese. Postpartum complications investigated during the hospital stay and 30 days post-discharge were: surgical wound infection and/or secretion, urinary infection, postpartum infection, fever, hospitalization, antibiotic use, and composite morbidity (at least one of the complications mentioned). Results: 374 puerperal women were included, graded according to the final BMI as: underweight (n = 54, 14.4%); adequate weight (n = 126, 33.7%); overweight (n = 105, 28.1%); and obese (n = 89, 23.8%). Maternal obesity was shown to have a significant association with the following postpartum complications: surgical wound infection (16.7%, p = 0.042), urinary infection (9.0%, p = 0.004), antibiotic use (12.3%, p < 0.001), and composite morbidity (25.6%, p = 0.016). By applying the logistic regression model, obesity in late pregnancy was found to be an independent variable regardless of the composite morbidity predicted (OR: 2.09; 95% CI: 1.15-3.80, p = 0.015). Conclusion: Maternal obesity during late pregnancy in high-risk patients is independently associated with postpartum infectious complications, which demonstrates the need for a closer follow-up of maternal weight gain in these pregnancies.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Purpose: To evaluate whether Nd:YAG laser irradiation of etched and unetched dentin through an uncured adhesive affected the microtensile bond strength (pTBS). Materials and Methods: Flat dentin surfaces were created in 19 extracted human third molars. Adper Single Bond (SB) adhesive was applied over etched (groups 1 to 3) or unetched dentin (groups 4 to 6). The dentin was then irradiated with a Nd:YAG laser through the uncured adhesive, using 0.75 or 1 W power settings, except for the control groups (groups 1 and 4). The adhesive was light cured and composite crowns were built up. After 24 h, the teeth were sectioned into beams, with cross-sectional areas of 0.49 mm(2), and were stressed under tension. Data were statistically analyzed using two-way ANOVA and Tukey's test (alpha = 5%). Dentin surfaces of fractured specimens and the interfaces of untested beams were observed under scanning electron microscopy (SEM). Results: Acid etching, laser irradiation, and their interaction significantly affected bonding (p < 0.05). Laser irradiation did not improve bonding of etched dentin to resin (p > 0.05). However, higher pTBS means were found on unetched lased dentin (groups 5 and 6), but only in comparison to group 4, where neither lasing nor etching was performed. Groups 4 to 6 showed the lowest pTBS means among all groups tested (p < 0.05). Laser irradiation did not change the characteristics of the hybrid layers created, while solidification globules were observed on lased dentin surfaces under SEM. Conclusion: Laser irradiation of dentin through the uncured adhesive did not significantly improve the pTBS in comparison to the suggested manufacturer's technique.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This paper reports the results of full-scale tests in beam-to-column connections for composite slim floor systems, including tests on Bare Steel connection and composite connection. The tested system consists of a concrete-filled composite column and a composite floor where an asymmetric steel beam is connected to a composite column by shear steel plates. Tests results previously obtained on partially encased composite beams were used to define the position of the headed studs in the slim floor system. Based on the obtained results of connections, the composite and Bare Steel connection behaved as semi-rigid and nominally pinned respectively. The tests results also indicated a significant contribution of the slim floor to the moment capacity of the connection. (C) 2011 Elsevier Ltd. All rights reserved.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Abstract Background Gyr cows are well adapted to tropical conditions, resistant to some tropical diseases and have satisfactory milk production. However, Gyr dairy herds have a high prevalence of subclinical mastitis, which negatively affects their milk yield and composition. The objectives of this study were (i) to evaluate the effects of seasonality, mammary quarter location (rear x front), mastitis-causing pathogen species, and somatic cell count (SCC) on milk composition in Gyr cows with mammary quarters as the experimental units and (ii) to evaluate the effects of seasonality and somatic cell count (SCC) on milk composition in Gyr cows with cows as the experimental units. A total of 221 lactating Gyr cows from three commercial dairy farms were selected for this study. Individual foremilk quarter samples and composite milk samples were collected once a month over one year from all lactating cows for analysis of SCC, milk composition, and bacteriological culture. Results Subclinical mastitis reduced lactose, nonfat solids and total solids content, but no difference was found in the protein and fat content between infected and uninfected quarters. Seasonality influenced milk composition both in mammary quarters and composite milk samples. Nevertheless, there was no effect of mammary quarter position on milk composition. Mastitis-causing pathogens affected protein, lactose, nonfat solids, and total solids content, but not milk fat content. Somatic cell count levels affected milk composition in both mammary quarters and composite samples of milk. Conclusions Intramammary infections in Gyr cows alter milk composition; however, the degree of change depends on the mastitis-causing pathogen. Somatic cell count is negatively associated with reduced lactose and nonfat solids content in milk. Seasonality significantly affects milk composition, in which the concentration of lactose, fat, protein, nonfat solids and total solids differs between dry and wet seasons in Gyr cows.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

In this research work I analyzed the instrumental seismicity of Southern Italy in the area including the Lucanian Apennines and Bradano foredeep, making use of the most recent seismological database available so far. I examined the seismicity occurred during the period between 2001 and 2006, considering 514 events with magnitudes M ≥ 2.0. In the first part of the work, P- and S-wave arrival times, recorded by the Italian National Seismic Network (RSNC) operated by the Istituto Nazionale di Geofisica e Vulcanologia (INGV), were re-picked along with those of the SAPTEX temporary array (2001–2004). For some events located in the Upper Val d'Agri, I also used data from the Eni-Agip oil company seismic network. I computed the VP/VS ratio obtaining a value of 1.83 and I carried out an analysis for the one-dimensional (1D) velocity model that approximates the seismic structure of the study area. After this preliminary analysis, making use of the records obtained in the SeSCAL experiment, I incremented the database by handpicking new arrival times. My final dataset consists of 15,666 P- and 9228 S-arrival times associated to 1047 earthquakes with magnitude ML ≥ 1.5. I computed 162 fault-plane solutions and composite focal mechanisms for closely located events. I investigated stress field orientation inverting focal mechanism belonging to the Lucanian Apennine and the Pollino Range, both areas characterized by more concentrated background seismicity. Moreover, I applied the double difference technique (DD) to improve the earthquake locations. Considering these results and different datasets available in the literature, I carried out a detailed analysis of single sub-areas and of a swarm (November 2008) recorded by SeSCAL array. The relocated seismicity appears more concentrated within the upper crust and it is mostly clustered along the Lucanian Apennine chain. In particular, two well-defined clusters were located in the Potentino and in the Abriola-Pietrapertosa sector (central Lucanian region). Their hypocentral depths are slightly deeper than those observed beneath the chain. I suggest that these two seismic features are representative of the transition from the inner portion of the chain with NE-SW extension to the external margin characterized by dextral strike-slip kinematics. In the easternmost part of the study area, below the Bradano foredeep and the Apulia foreland, the seismicity is generally deeper and more scattered and is associated to the Murge uplift and to the small structures present in the area. I also observed a small structure NE-SW oriented in the Abriola-Pietrapertosa area (activated with a swarm in November 2008) that could be considered to act as a barrier to the propagation of a potential rupture of an active NW-SE striking faults system. Focal mechanisms computed in this study are in large part normal and strike-slip solutions and their tensional axes (T-axes) have a generalized NE-SW orientation. Thanks to denser coverage of seismic stations and the detailed analysis, this study is a further contribution to the comprehension of the seismogenesis and state of stress of the Southern Apennines region, giving important contributions to seismotectonic zoning and seismic hazard assessment.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Accurate placement of lesions is crucial for the effectiveness and safety of a retinal laser photocoagulation treatment. Computer assistance provides the capability for improvements to treatment accuracy and execution time. The idea is to use video frames acquired from a scanning digital ophthalmoscope (SDO) to compensate for retinal motion during laser treatment. This paper presents a method for the multimodal registration of the initial frame from an SDO retinal video sequence to a retinal composite image, which may contain a treatment plan. The retinal registration procedure comprises the following steps: 1) detection of vessel centerline points and identification of the optic disc; 2) prealignment of the video frame and the composite image based on optic disc parameters; and 3) iterative matching of the detected vessel centerline points in expanding matching regions. This registration algorithm was designed for the initialization of a real-time registration procedure that registers the subsequent video frames to the composite image. The algorithm demonstrated its capability to register various pairs of SDO video frames and composite images acquired from patients.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

In dentistry the restoration of decayed teeth is challenging and makes great demands on both the dentist and the materials. Hence, fiber-reinforced posts have been introduced. The effects of different variables on the ultimate load on teeth restored using fiber-reinforced posts is controversial, maybe because the results are mostly based on non-standardized in vitro tests and, therefore, give inhomogeneous results. This study combines the advantages of in vitro tests and finite element analysis (FEA) to clarify the effects of ferrule height, post length and cementation technique used for restoration. Sixty-four single rooted premolars were decoronated (ferrule height 1 or 2 mm), endodontically treated and restored using fiber posts (length 2 or 7 mm), composite fillings and metal crowns (resin bonded or cemented). After thermocycling and chewing simulation the samples were loaded until fracture, recording first damage events. Using UNIANOVA to analyze recorded fracture loads, ferrule height and cementation technique were found to be significant, i.e. increased ferrule height and resin bonding of the crown resulted in higher fracture loads. Post length had no significant effect. All conventionally cemented crowns with a 1-mm ferrule height failed during artificial ageing, in contrast to resin-bonded crowns (75% survival rate). FEA confirmed these results and provided information about stress and force distribution within the restoration. Based on the findings of in vitro tests and computations we concluded that crowns, especially those with a small ferrule height, should be resin bonded. Finally, centrally positioned fiber-reinforced posts did not contribute to load transfer as long as the bond between the tooth and composite core was intact.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This study evaluated the enamel loss and composite remnants after debonding and clean-up. The tested null hypothesis is that there are no differences between different polishing systems regarding removing composite remnants without damaging the tooth surface. Brackets were bonded to 75 extracted human molars and removed after a storage period of 100 hours. The adhesive remnant index (ARI) was evaluated. The clean-up was carried out with five different procedures: 1. carbide bur; 2. carbide bur and Brownie and Greenie silicone polishers; 3. carbide bur and Astropol polishers; 4. carbide bur and Renew polishers; and 5. carbide bur, Brownie, Greenie and PoGo polishers. Silicone impressions were made at baseline (T0) and after debonding (T1) and polishing (T2) to produce plaster replicas. The replicas were analysed with a three-dimensional laser scanner and measured with analytical software. Statistical analysis was performed with the Kruskal-Wallis test and pairwise Wilcoxon tests with Bonferroni-Holm adjustment (α = 0.05). Enamel breakouts after debonding were detectable in 27 per cent of all cases, with a mean volume loss of 0.02 mm(3) (±0.03 mm(3)) and depth of 44.9 μm (±48.3 μm). The overall ARI scores was 3 with a few scores of 1 and 2. The composite remnants after debonding had a mean volume of 2.48 mm(3) (±0.92 mm(3)). Mean volume loss due to polishing was 0.05 mm(3) (±0.26 mm(3)) and the composite remnants had a mean volume of 0.22 mm(3) (±0.32 mm(3)). There were no statistically significant differences in volumetric changes after polishing (P = 0.054) between the different clean-up methods. However, sufficient clean-up without enamel loss was difficult to achieve.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Class II cavities were prepared in extracted lower molars filled and cured in three 2-mm increments using a metal matrix. Three composites (Spectrum TPH A4, Ceram X mono M7 and Tetric Ceram A4) were cured with both the SmartLite PS LED LCU and the Spectrum 800 continuous cure halogen LCU using curing cycles of 10, 20 and 40 seconds. Each increment was cured before adding the next. After a seven-day incubation period, the composite specimens were removed from the teeth, embedded in self-curing resin and ground to half the orofacial width. Knoop microhardness was determined 100, 200, 500, 1000, 1500, 2500, 3500, 4500 and 5500 microm from the occlusal surface at a distance of 150 microm and 1000 microm from the metal matrix. The total degree of polymerization of a composite specimen for any given curing time and curing light was determined by calculating the area under the hardness curve. Hardness values 150 microm from the metal matrix never reached maximum values and were generally lower than those 1000 microm from the matrix. The hardest composite was usually encountered between 200 microm and 1000 microm from the occlusal surface. For every composite-curing time combination, there was an increase in microhardness at the top of each increment (measurements at 500, 2500 and 4500 microm) and a decrease towards the bottom of each increment (measurements at 1500, 3500 and 5500 microm). Longer curing times were usually combined with harder composite samples. Spectrum TPH composite was the only composite showing a satisfactory degree of polymerization for all three curing times and both LCUs. Multiple linear regression showed that only the curing time (p < 0.001) and composite material (p < 0.001) had a significant association with the degree of polymerization. The degree of polymerization achieved by the LED LCU was not significantly different from that achieved by the halogen LCU (p = 0.54).

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Smoothing splines are a popular approach for non-parametric regression problems. We use periodic smoothing splines to fit a periodic signal plus noise model to data for which we assume there are underlying circadian patterns. In the smoothing spline methodology, choosing an appropriate smoothness parameter is an important step in practice. In this paper, we draw a connection between smoothing splines and REACT estimators that provides motivation for the creation of criteria for choosing the smoothness parameter. The new criteria are compared to three existing methods, namely cross-validation, generalized cross-validation, and generalization of maximum likelihood criteria, by a Monte Carlo simulation and by an application to the study of circadian patterns. For most of the situations presented in the simulations, including the practical example, the new criteria out-perform the three existing criteria.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Objective: The aim of this literature review, performed within the framework of the Swiss governmental Program of Evaluation of Complementary Medicine (PEK), was to investigate costs of complementary and alternative medicine (CAM). Materials and Methods: A systematic literature search was conducted in 11 electronic databases. All retrieved titles and reference lists were also hand-searched. Results: 38 publications were found: 23 on CAM of various definitions (medical and non-medical practitioners, over-the-counter products), 13 on homeopathy, 2 on phytotherapy. Studies investigated different kinds of costs (direct or indirect) and used different methods (prospective or retrospective questionnaires, data analyses, cost-effectiveness models). Most studies report 'out of pocket' costs, because CAM is usually not covered by health insurance. Costs per CAM-treatment / patient / month were AUD 7-66, CAD 250 and GBP 13.62 +/- 1.61. Costs per treatment were EUR 205 (range: 15-1,278), USD 414 +/- 269 and USD 1,127. In two analyses phytotherapy proved to be cost-effective. One study revealed a reduction of 1.5 days of absenteeism from work in the CAM group compared to conventionally treated patients. Another study, performed by a health insurance company reported a slight increase in direct costs for CAM. Costs for CAM covered by insurance companies amounted to approximately 0.2-0.5% of the total healthcare budget (Switzerland, 2003). Publications had several limitations, e.g. efficacy of therapies was rarely reported. As compared to conventional patients, CAM patients tend to cause lower costs. Conclusion: Results suggest lower costs for CAM than for conventional patients, but the limited methodological quality lowers the significance of the available data. Further well-designed studies and models are required.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Summary. Background: Accurate estimates of the incidence of thrombotic thrombocytopenic purpura (TTP) are important to assess the resources required for current treatments as well as to anticipate the need to develop new treatments. Previous estimates have been indirect and have not reported data on patients with ADAMTS-13 deficiency. Objective: To determine the incidence of patients with TTP-hemolytic uremic syndrome (HUS) in three categories: all patients with clinically suspected TTP-HUS, patients with idiopathic TTP-HUS, and patients with severe ADAMTS-13 deficiency. Methods: Incidence rates were estimated from the Oklahoma TTP-HUS Registry, analyzing all 206 consecutive patients from January 1, 1996 to June 30, 2004 who were treated with plasma exchange for their initial episode of clinically suspected TTP-HUS. ADAMTS-13 activity was measured in 186 (90%) of the 206 patients. Results: The age–sex–race standardized annual incidence rates were 11.29 × 106 (95% CI: 9.70–12.88) for all patients with clinically suspected TTP-HUS; 4.46 × 106 (95% CI: 3.43–5.50) for patients with idiopathic TTP-HUS; and 1.74 × 106 (95% CI: 1.06–2.41) for patients with severe ADAMTS-13 deficiency (<5% activity). In all three categories, the incidence rates were greater for women and for blacks. For patients with severe ADAMTS-13 deficiency, the age–sex standardized incidence rate ratio of blacks to non-blacks was 9.29 (95% CI: 4.33–19.93). Conclusions: Accurate incidence rate estimates for all patients with clinically suspected TTP-HUS, idiopathic TTP-HUS, and TTP associated with severe ADAMTS-13 deficiency have been determined. The greater incidence among women and blacks is comparable with their increased risk for other autoimmune disorders.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

AIM: To assess survival rates and complications of root-filled teeth restored with or without post-and-core systems over a mean observation period of >or=4 years. METHODOLOGY: A total of 325 single- and multirooted teeth in 183 subjects treated in a private practice were root filled and restored with either a cast post-and-core or with a prefabricated titanium post and composite core. Root-filled teeth without post-retained restorations served as controls. The restored teeth served as abutments for single unit metal-ceramic or composite crowns or fixed bridges. Teeth supporting cantilever bridges, overdentures or telescopic crowns were excluded. RESULTS: Seventeen teeth in 17 subjects were lost to follow-up (17/325: 5.2%). The mean observation period was 5.2 +/- 1.8 (SD) years for restorations with titanium posts, 6.2 +/- 2.0 (SD) years for cast post-and-cores and 4.4 +/- 1.7 (SD) years for teeth without posts. Overall, 54% of build-ups included the incorporation of a titanium post and 26.5% the cementation of a cast post-and-core. The remaining 19.5% of the teeth were restored without intraradicular retention. The adjusted 5-year tooth survival rate amounted to 92.5% for teeth restored with titanium posts, to 97.1% for teeth restored with cast post-and-cores and to 94.3% for teeth without post restorations, respectively. The most frequent complications included root fracture (6.2%), recurrent caries (1.9%), post-treatment periradicular disease (1.6%) and loss of retention (1.3%). CONCLUSION: Provided that high-quality root canal treatment and restorative protocols are implemented, high survival and low complication rates of single- and multirooted root-filled teeth used as abutments for fixed restorations can be expected after a mean observation period of >or=4 years.