991 resultados para implant-supported prosthesis


Relevância:

100.00% 100.00%

Publicador:

Resumo:

OBJECTIVE: The aim of this study was to gather information and discuss the predictability of implant-supported prostheses in patients with bruxism by performing a literature review. METHODS: In order to select the studies included in this review, a detailed search was performed in PubMed and Medline databases, using the following key words: bruxism, dental implants, implant supported prosthesis, and dental restoration failure. Items that were included are: case reports, randomized controlled trials, in vitro studies, literature and systematic reviews, with or without meta-analysis, of the last 20 years that addressed the theme. Articles without abstracts, animal studies, articles in languages other than English and articles from journals unrelated to the dental field were excluded. RESULTS: after analysis according to inclusion and exclusion criteria, 28 articles were selected from a total of 54. It is known from the array of scientific articles which have assessed, either through retrospective, prospective or experimental studies, that the biomechanical and biological impact of bruxism on implant-supported prostheses is small, and that the literature has contributed little to exemplify the prosthetic limits of safety for the specialist from a clinical point of view. CONCLUSION: Although there is still no general consensus on this matter, most of the literature review articles do provide clinical guidelines that contribute to implant supported prostheses longevity and stability in patients with bruxism.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Introduction: The oral rehabilitation with dental implants is a very viable treatment modality for patients. Therefore the discovery of osseointegration, dentistry has reached the trigger with respect to treatment with a high predictability of success. For this various principles, since the surgical protocols, the choice of material and even the technique for the manufacture of implant-supported prosthesis influence a good prognosis for treatment. Objective: Therefore, it is proposed this study a literature review of the fundamentals of osseointegration, explaining the historical and technical parameters of implantology, focusing in what the literature currently is studying with more intensity, the acceleration of osseointegration. Conclusion:well conducted procedures promotes the best aimed success in implantology. Rough surfaces shows great are for implant-bone contact and better mechanical results. The bone quality is fundamental in results foresigh.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This case report shows how the prognosis of severe mandibular atrophy can be improved with the use of short dental implants. A Caucasian 54 years-old male patient received four dental implants in the anterior mandibular region. Four months later, the definitive prosthesis was delivered. At the 8-year follow-up period, no complaints or loss of integration were reported. Short dental implants with complete, fixed definitive prosthesis can be a successful treatment in the mandibular arch.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Excessive cantilever lengths of fixed implant-supported prostheses may have functional and biomechanical disadvantages. This study reports the clinical outcomes of unconventional implants placed for distal support of a fixed implant-supported prostheses. Seven extraoral implants with intraosseous lengths of 2.5 to 4.0 mm were placed in four patients. Distal cantilevers had a mean length of 29.8 mm (range, 18.6 to 39.3 mm). No bone loss or other adverse events were found. The prosthetic plan was maintained in all patients. Within the limits of the employed research design, this concept seems to be a successful option for fixed complete implant-supported prosthesis treatment.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Background: Several theories, such as the biological width formation, the inflammatory reactions due to the implant-abutment microgap contamination, and the periimplant stress/strain concentration causing bone microdamage accumulation, have been suggested to explain early periimplant bone loss. However, it is yet not well understood to which extent the implant-abutment connection type may influence the remodeling process around dental implants. Aim: to evaluate clinical, bacteriological, and biomechanical parameters related to periimplant bone loss at the crestal region, comparing external hexagon (EH) and Morse-taper (MT) connections. Materials and methods: Twelve patients with totally edentulous mandibles received four custom made Ø 3.8 x 13 mm implants in the interforaminal region of the mandible, with the same design, but different prosthetic connections (two of them EH or MT, randomly placed based on a split-mouth design), and a immediate implant- supported prosthesis. Clinical parameters (periimplant probing pocket depth, modified gingival index and mucosal thickness) were evaluated at 6 sites around the implants, at a 12 month follow-up. The distance from the top of the implant to the first bone-to-implant contact – IT-FBIC was evaluated on standardized digital peri-apical radiographs acquired at 1, 3, 6 and 12 months follow-up. Samples of the subgingival microbiota were collected 1, 3 and 6 months after implant loading. DNA were extracted and used for the quantification of Tanerella forsythia, Porphyromonas gingivalis, Aggragatibacter actinomycetemcomitans, Prevotella intermedia and Fusobacterium nucleatum. Comparison among multiple periods of observation were performed using repeated-measures Analysis of Variance (ANOVA), followed by a Tukey post-hoc test, while two-period based comparisons were made using paired t- test. Further, 36 computer-tomographic based finite element (FE) models were accomplished, simulating each patient in 3 loading conditions. The results for the peak EQV strain in periimplant bone were interpreted by means of a general linear model (ANOVA). Results: The variation in periimplant bone loss assessed by means of radiographs was significantly different between the connection types (P<0.001). Mean IT-FBIC was 1.17±0.44 mm for EH, and 0.17±0.54 mm for MT, considering all evaluated time periods. All clinical parameters presented not significant differences. No significant microbiological differences could be observed between both connection types. Most of the collected samples had very few pathogens, meaning that these regions were healthy from a microbiological point of view. In FE analysis, a significantly higher peak of EQV strain (P=0.005) was found for EH (mean 3438.65 µ∑) compared to MT (mean 840.98 µ∑) connection. Conclusions: Varying implant-abutment connection type will result in diverse periimplant bone remodeling, regardless of clinical and microbiological conditions. This fact is more likely attributed to the singular loading transmission through different implant-abutment connections to the periimplant bone. The present findings suggest that Morse-taper connection is more efficient to prevent periimplant bone loss, compared to an external hexagon connection.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This case report details the successful rehabilitation of an edentulous patient using a complete upper prosthesis and a lower implant retained overdenture. The provision of care was split between a specialist centre and a primary care setting. This approach reduced inconvenience to the patient. Modern surgical and prosthodontic techniques also reduced the total delivery time. After initial consultation a new set of complete dentures was prescribed with changes in design to the originals. The patient was also planned for placement of two mandibular implants to stabilise and retain the mandibular denture. The first line of treatment involved provision of a new set of dentures constructed by the patient's general dental practitioner. Dental implants were then placed in a specialist centre and the patient returned to the dental practice for attachment of the lower denture to the dental implants. The benefits and success of mandibular implant retained dentures are well documented. With delivery of the overdenture, the patient reported increased satisfaction with his prostheses which allowed him to eat a greater range of foods and enabled him to feel confident when speaking and socialising.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The purposes of this study were to photoelastically measure the biomechanical behavior of 4 implants retaining different cantilevered bar mandibular overdenture designs and to compare a fixed partial denture (FPD). A photoelastic model of a human edentulous mandible was fabricated, which contained 4 screw-type implants (3.75 x 10 mm) embedded in the parasymphyseal area. An FPD and 3 overdenture designs with the following attachments were evaluated: 3 plastic Hader clips, 1 Hader clip with 2 posterior resilient cap attachments, and 3 ball/O-ring attachments. Vertical occlusal forces of 100 N were applied between the central incisor and unilaterally to the right and left second premolars and second molars. Stresses that developed in the supporting structure were monitored photoelastically and recorded photographically. The results showed that the anterior loading, the overdenture with 3 plastic Hader clips, displayed the largest stress concentration at the medium implant. With premolar loading, the FPD and overdenture with 3 plastic Hader clips displayed the highest stresses to the ipsilateral terminal implant. With molar loading, the overdenture with 3 ball/O-ring attachments displayed the most uniform stress distribution in the posterior edentulous ridge, with less overloading in the terminal implant. It was concluded that vertical forces applied to the bar-clip overdenture and FPD created immediate stress patterns of greater magnitude and concentration on the ipsilateral implants, whereas the ball/O-ring attachments transferred minimal stress to the implants. The increased cantilever in the FPD caused the highest stresses to the terminal implant.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Different transfer impression techniques for implant-supported prostheses have been suggested to obtain a working cast. This article describes and illustrates clinical and laboratory pros-thodontic procedures to transfer implant positions with splinted transfer copings and without impression material to form a laboratory analog transfer template. With this technique, a preliminary cast is modified to place the analogs according to a corrected position and obtain the master cast. Although this technique does not record adjacent tissues, it is a simple procedure, less time consuming, and easily performed.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Background: Considering that an increasing number of patients are victims of mutilator surgical resections, these studies are important for treatment success of rehabilitation of patients presenting oronasal communication.Purpose: The aim of this study was to assess the stress distribution through photoelasticity in palatal obturator prostheses with different attachment systems for implants.Methods: Two photoelastic models were obtained from an experimental maxillary model presenting an oronasal communication. One model was fabricated without implant, and the other with 2 implants 10 mm in length inserted in the left crest. Four colorless palatal obturator prostheses were fabricated. One prosthesis presented no attachment system, whereas the remaining prostheses were adapted to 3 attachment systems. The assembly was positioned in a circular polariscope for application of axial load.Results: The results were based on photographic records of stress in the photoelastic model submitted to loading. The records revealed higher stress concentration on the bar-clip system followed by the O'ring/bar-clip and O'ring systems, respectively. A homogeneous stress distribution was observed on the photoelastic model with the mucous-supported prosthesis.Conclusions: The attachment systems generated different characteristics of stress distribution that was concentrated surrounding the implants. The bar-clip system exhibited the highest stress concentration on the alveolar crest.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Complete and partial loss of maxillary bone may jeopardize oral physiology and generate complications as oral-sinus-nasal communication. Palatal obturator prostheses are a treatment alternative for rehabilitation of these patients. The aim of this study was to assess stress distribution, through photoelasticity, on palatal obturator prostheses associated with different attachment systems (o'ring, bar clip, and o'ring/bar clip) of implants and submitted to relining. Two photoelastic models were fabricated according to an experimental maxillary model with oral-sinus-nasal communication. One model did not present implants, whereas the other included 2 implants with 13.0 mm in length in the left ridge. Four colorless maxillary obturator prostheses were fabricated and relined with soft silicone. One of these prostheses presented no attachment system, whereas the remaining prostheses included attachment systems adapted to the implants. The assembly (model/attachment system/prosthesis) was positioned in a circular polariscope during loading with 100 N at 10 mm/s. The results were based on observation during the experiment and photographic records of stress on the photoelastic model. The bar clip system exhibited the highest stress concentration followed by o'ring/bar clip and o'ring systems. The attachment systems presented different stress distribution with greater concentration surrounding the implants and homogenous stress distribution on the photoelastic model without implants. The highest concentration of fringes occurred, in ascending order, with o'ring, o'ring/bar clip, and bar clip systems.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Objectives: The present study used strain gauge analysis to perform an in vitro evaluation of the effect of axial loading on 3 elements of implant-supported partial fixed prostheses, varying the type of prosthetic cylinder and the loading points. Material and methods: Three internal hexagon implants were linearly embedded in a polyurethane block. Microunit abutments were connected to the implants applying a torque of 20 Ncm, and prefabricated Co-Cr cylinders and plastic prosthetic cylinders were screwed onto the abutments, which received standard patterns cast in Co-Cr alloy (n=5). Four strain gauges (SG) were bonded onto the surface of the block tangentially to the implants, SG 01 mesially to implant 1, SG 02 and SG 03 mesially and distally to implant 2, respectively, and SG 04 distally to implant 3. Each metallic structure was screwed onto the abutments with a 10 Ncm torque and an axial load of 30 kg was applied at five predetermined points (A, B, C, D, E). The data obtained from the strain gauge analyses were analyzed statistically by RM ANOVA and Tukey's test, with a level of significance of p<0.05. Results: There was a significant difference for the loading point (p=0.0001), with point B generating the smallest microdeformation (239.49 mu epsilon) and point D the highest (442.77 mu epsilon). No significant difference was found for the cylinder type (p=0.748). Conclusions: It was concluded that the type of cylinder did not affect in the magnitude of microdeformation, but the axial loading location influenced this magnitude.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The aim of this study was to evaluate stress distribution of the peri-implant bone by simulating the biomechanical influence of implants with different diameters of regular or platform switched connections by means of 3-dimensional finite element analysis. Five mathematical models of an implant-supported central incisor were created by varying the diameter (5.5 and 4.5 mm, internal hexagon) and abutment platform (regular and platform switched). For the cortical bone, the highest stress values (rmax and rvm) were observed in situation R1, followed by situations S1, R2, S3, and S2. For the trabecular bone, the highest stress values (rmax) were observed in situation S3, followed by situations R1, S1, R2, and S2. The influence of platform switching was more evident for cortical bone than for trabecular bone and was mainly seen in large platform diameter reduction.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The retaining screw of the implant-supported dental prosthesis is the weakest point of the crown/implant system. Furthermore, crown height is another important factor that may increase the lever arm. Therefore, the aim of this study was to assess the stress distribution in implant prosthetic screws with different heights of the clinical crown of the prosthesis using the method of three-dimensional finite element analysis. Three models were created with implants (3.75 mm × 10 mm) and crowns (heights of 10, 12.5 and 15 mm). The results were visualised by means of von Mises stress maps that increased the crown heights. The screw structure exhibited higher levels of stresses in the oblique load. The oblique loading resulted in higher stress concentration when compared with the axial loading. It is concluded that the increase of the crown was damaging to the stress distribution on the screw, mainly in oblique loading. © 2013 Taylor & Francis.