965 resultados para hydraulic pump
Resumo:
Spontaneous mutants resistant to fluoroquinolones were obtained by exposing Serratia marcescens NIMA (wild-type strain) to increasing concentrations of ciprofloxacin both in liquid and on solid media. Frequencies of mutation ranged from 10-7 to 10-9. Active expulsion of antibiotic was explored as a possible mechanism of resistance in mutants as well as changes in topoisomerase target genes. The role of extrusion mechanisms in determining the emergence of multidrug-resistant bacteria was also examined. Mutants resistant to high concentrations of fluoroquinolones had a single mutation in their gyrA QRDR sequences, whereas the moderate resistance in the rest of mutants was due to extrusion of the drug
Resumo:
Spontaneous mutants resistant to fluoroquinolones were obtained by exposing Serratia marcescens NIMA (wild-type strain) to increasing concentrations of ciprofloxacin both in liquid and on solid media. Frequencies of mutation ranged from 10-7 to 10-9. Active expulsion of antibiotic was explored as a possible mechanism of resistance in mutants as well as changes in topoisomerase target genes. The role of extrusion mechanisms in determining the emergence of multidrug-resistant bacteria was also examined. Mutants resistant to high concentrations of fluoroquinolones had a single mutation in their gyrA QRDR sequences, whereas the moderate resistance in the rest of mutants was due to extrusion of the drug
Resumo:
This thesis gives an overview of the validation process for thermal hydraulic system codes and it presents in more detail the assessment and validation of the French code CATHARE for VVER calculations. Three assessment cases are presented: loop seal clearing, core reflooding and flow in a horizontal steam generator. The experience gained during these assessment and validation calculations has been used to analyze the behavior of the horizontal steam generator and the natural circulation in the geometry of the Loviisa nuclear power plant. The cases presented are not exhaustive, but they give a good overview of the work performed by the personnel of Lappeenranta University of Technology (LUT). Large part of the work has been performed in co-operation with the CATHARE-team in Grenoble, France. The design of a Russian type pressurized water reactor, VVER, differs from that of a Western-type PWR. Most of thermal-hydraulic system codes are validated only for the Western-type PWRs. Thus, the codes should be assessed and validated also for VVER design in order to establish any weaknesses in the models. This information is needed before codes can be used for the safety analysis. Theresults of the assessment and validation calculations presented here show that the CATHARE code can be used also for the thermal-hydraulic safety studies for VVER type plants. However, some areas have been indicated which need to be reassessed after further experimental data become available. These areas are mostly connected to the horizontal stem generators, like condensation and phase separation in primary side tubes. The work presented in this thesis covers a large numberof the phenomena included in the CSNI code validation matrices for small and intermediate leaks and for transients. Also some of the phenomena included in the matrix for large break LOCAs are covered. The matrices for code validation for VVER applications should be used when future experimental programs are planned for code validation.
Resumo:
Electrically driven Er3+ doped Si slot waveguides emitting at 1530 nm are demonstrated. Two different Er3+ doped active layers were fabricated in the slot region: a pure SiO2 and a Si-rich oxide. Pulsed polarization driving of the waveguides was used to characterize the time response of the electroluminescence (EL) and of the signal probe transmission in 1 mm long waveguides. Injected carrier absorption losses modulate the EL signal and, since the carrier lifetime is much smaller than that of Er3+ ions, a sharp EL peak was observed when the polarization was switched off. A time-resolved electrical pump & probe measurement in combination with lock-in amplifier techniques allowed to quantify the injected carrier absorption losses. We found an extinction ratio of 6 dB, passive propagation losses of about 4 dB/mm, and a spectral bandwidth > 25 nm at an effective d.c. power consumption of 120 μW. All these performances suggest the usage of these devices as electro-optical modulators.
Resumo:
Työssä on tutkittu pumpun valintaa integroidussa simulointiympäristössä. Tutkimuksen avulla on tarkoitus kehittää tieto- ja malligallerian (Galleria) infrastuktuuria ja käytössä olevia työvälineitä siihen suuntaan, että ulkoisten valitsinkomponenttien implementoiminen Gallerian tietokantaan olisi lähitulevaisuudessa helppoa ja nopeaa. Prosessi-integraation tieto- ja malligalleria on infrastruktuurimäärittely ja työvälineistö prosessikomponenttien ja osaprosessien simulointiin tarvittavien malli- ja parametritietojen kirjastoimiseksi internetpohjaiseen tietokantaan, josta ne ovat simulointiohjelmien käyttäjien ja muiden prosessisuunnittelijoiden helposti saatavilla. Tutkimuksen kirjallisessa osassa on keskitytty tutkimaan pumpun valinnan etenemistä ja valintaan vaikuttavia tekijöitä prosessisuunnittelijan näkökulmasta. Tutkimuksen soveltavassa osassa luotiin pumpunvalitsin ja sitä testattiiin Galleria- ympäristöä vastaavassa kehitysympäristössä. Pumpunvalitsimen kehittämisessä on käytetty apuna laitevalmistajalta saatua prosessikomponenttitietoa. Pumpunvalitsimen toteutus perustuu pumpun hydrauliseen valintaan ja esimerkkitapauksena käytettiin keskipakopumppua
Resumo:
Tässä diplomityössä käsitellään pumppujen maailmanlaajuista varaosa-jakelua. Työn pääpaino on varaosien moniportaisen jakeluverkon toimitusketjun logistiikassa. Asiakaspalvelussa varaosien nopea saatavuus on ratkaisevassa asemassa, jotta asiakkaiden tehtaiden käynnissäpito voidaan turvata. Työn tavoitteena oli kehittää Ahlström Pumpuille uusi globaali toimintamalli varaosien jakeluun. Tämä uusi varaosien jakelumalli on kehitetty pääasiassa sopimusasiakkaille, jotka ovat halukkaita ulkoistamaan varaosatoimintonsa. Mallia sovelletaan käytäntöön varaosien jakelussa ensiksi Suomessa ja Ruotsissa. Myöhemmin on tarkoitus kopioida mallia myös muualle. Malli on pyritty rakentamaan siten, että siihen voidaan helposti liittää muita Ahlström Pumppujen tarjoamia palveluita. Työssä koottu materiaali perustuu pääasiassa haastatteluihin, palavereihin, erilaisiin sisäisiin raportteihin, kirjallisuuteen ja itsenäiseen selvitystyöhön. Työssä on myös tutustuttu kolmen eri yrityksen after-sales- ja varaosatoimintaan.
Resumo:
Työn tavoitteena oli laatia euron käyttöönottosuunnitelma. Ensin selvitettiin euron syntyvaiheet ja yhteisen valuutan käsittelysäännöt. Sen jälkeen käydään läpi eräs käyttökelpoinen suunnitelma euron käyttöönottamiseksi, johon kuuluu euron käyttöönoton and speed up the implementation of external selection components. Model and Parametrisation Gallery for Process Integration is specification of an infrastructure and a set of tools which are built for storing process component and model library data into an internet based database from where it can be easily used by simulator users and other process designers. This work consists of two parts. In the literature survey pump selection and the factors that affects selection particularly on process designers point of view are studied. In the applied part a pump selector was created and tested in the test environment which is comparable to Gallery environment. This was done to ease the deployment of the selector to the actual working environment. Process component data of a manufacturer was used on the development of the pump selector. The execution of the selector is based on the hydraulic selection of pumps. Centrifugal pump was used as an example case.
Resumo:
Several possible methods of increasing the efficiency and power of hydro power plants by improving the flow passages are investigated in this stydy. The theoretical background of diffuser design and its application to the optimisation of hydraulic turbine draft tubes is presented in the first part of this study. Several draft tube modernisation projects that have been carried out recently are discussed. Also, a method of increasing the efficiency of the draft tube by injecting a high velocity jet into the boundary layer is presented. Methods of increasing the head of a hydro power plant by using an ejector or a jet pump are discussed in the second part of this work. The theoretical principles of various ejector and jet pump types are presented and four different methods of calculating them are examined in more detail. A self-made computer code is used to calculate the gain in the head for two example power plants. Suitable ejector installations for the example plants are also discussed. The efficiency of the ejector power was found to be in the range 6 - 15 % for conventional head increasers, and 30 % for the jet pump at its optimum operating point. In practice, it is impossible to install an optimised jet pump with a 30 % efficiency into the draft tube as this would considerabely reduce the efficiency of the draft tube at normal operating conditions. This demonstrates, however, the potential for improvement which lies in conventional head increaser technology. This study is based on previous publications and on published test results. No actual laboratory measurements were made for this study. Certain aspects of modelling the flow in the draft tube using computational fluid dynamics are discussed in the final part of this work. The draft tube inlet velocity field is a vital boundary condition for such a calculation. Several previously measured velocity fields that have successfully been utilised in such flow calculations are presented herein.
Resumo:
This thesis analyses the calculation of FanSave and PumpSave energy saving tools calculation. With these programs energy consumption of variable speed drive control for fans and pumps can be compared to other control methods. With FanSave centrifugal and axial fans can be examined and PumpSave deals with centrifugal pumps. By means of these programs also suitable frequency converter can be chosen from the ABB collection. Programs need as initial values information about the appliances like amount of flow and efficiencies. Operation time is important factor when calculating the annual energy consumption and information about it are the length and profile. Basic theory related to fans and pumps is introduced without more precise instructions for dimensioning. FanSave and PumpSave contain various methods for flow control. These control methods are introduced in the thesis based on their operational principles and suitability. Also squirrel cage motor and frequency converter are introduced because of their close involvement to fans and pumps. Second part of the thesis contains comparison between results of FanSave’s and PumpSave’s calculation and performance curve based calculation. Also laboratory tests were made with centrifugal and axial fan and also with centrifugal pump. With the results from this thesis the calculation of these programs can be adjusted to be more accurate and also some new features can be added.
Resumo:
The aim of the study is to obtain a mathematical description for an alternative variant of controlling a hydraulic circuit with an electrical drive. The electrical and hydraulic systems are described by basic mathematical equations. The flexibilities of the load and boom is modeled with assumed mode method. The model is achieved and proven with simulations. The controller is constructed and proven to decrease oscillations and improve the dynamic response of the system.
Resumo:
Off-pump coronary bypass grafting may decrease the rate of stroke, due to minimal aortic manipulation. For venous grafts, clampless hemostasis when performing the proximal anastomosis can be achieved using the Heartstring device. We describe a technique using a single device to suture two veins to one aortotomy. This technique requires less space and could be advantageous in very short, small, and calcified aortas. In to our experience, this technique is rapid, simple, easy to reproduce, and cost-saving.
Resumo:
Consensus diagnostic recommendations to distinguish GORD from eosinophilic oesophagitis (EoE) by response to a trial of proton pump inhibitors (PPIs) unexpectedly uncovered an entity called 'PPI-responsive oesophageal eosinophilia' (PPI-REE). PPI-REE refers to patients with clinical and histological features of EoE that remit with PPI treatment. Recent and evolving evidence, mostly from adults, shows that patients with PPI-REE and patients with EoE at baseline are clinically, endoscopically and histologically indistinguishable and have a significant overlap in terms of features of Th2 immune-mediated inflammation and gene expression. Furthermore, PPI therapy restores oesophageal mucosal integrity, reduces Th2 inflammation and reverses the abnormal gene expression signature in patients with PPI-REE, similar to the effects of topical steroids in patients with EoE. Additionally, recent series have reported that patients with EoE responsive to diet/topical steroids may also achieve remission on PPI therapy. This mounting evidence supports the concept that PPI-REE represents a continuum of the same immunological mechanisms that underlie EoE. Accordingly, it seems counterintuitive to differentiate PPI-REE from EoE based on a differential response to PPI therapy when their phenotypic, molecular, mechanistic and therapeutic features cannot be reliably distinguished. For patients with symptoms and histological features of EoE, it is reasonable to consider PPI therapy not as a diagnostic test, but as a therapeutic agent. Due to its safety profile, ease of administration and high response rates (up to 50%), PPI can be considered a first-line treatment before diet and topical steroids. The reasons why some patients with EoE respond to PPI, while others do not, remain to be elucidated.
Resumo:
Apart from its role as a flow generator for ventilation the diaphragm has a circulatory role. The cyclical abdominal pressure variations from its contractions cause swings in venous return from the splanchnic venous circulation. During exercise the action of the abdominal muscles may enhance this circulatory function of the diaphragm. Eleven healthy subjects (25 ± 7 year, 70 ± 11 kg, 1.78 ± 0.1 m, 3 F) performed plantar flexion exercise at ~4 METs. Changes in body volume (ΔVb) and trunk volume (ΔVtr) were measured simultaneously by double body plethysmography. Volume of blood shifts between trunk and extremities (Vbs) was determined non-invasively as ΔVtr-ΔVb. Three types of breathing were studied: spontaneous (SE), rib cage (RCE, voluntary emphasized inspiratory rib cage breathing), and abdominal (ABE, voluntary active abdominal expiration breathing). During SE and RCE blood was displaced from the extremities into the trunk (on average 0.16 ± 0.33 L and 0.48 ± 0.55 L, p < 0.05 SE vs. RCE), while during ABE it was displaced from the trunk to the extremities (0.22 ± 0.20 L p < 0.001, p < 0.05 RCE and SE vs. ABE respectively). At baseline, Vbs swings (maximum to minimum amplitude) were bimodal and averaged 0.13 ± 0.08 L. During exercise, Vbs swings consistently increased (0.42 ± 0.34 L, 0.40 ± 0.26 L, 0.46 ± 0.21 L, for SE, RCE and ABE respectively, all p < 0.01 vs. baseline). It follows that during leg exercise significant bi-directional blood shifting occurs between the trunk and the extremities. The dynamics and partitioning of these blood shifts strongly depend on the relative predominance of the action of the diaphragm, the rib cage and the abdominal muscles. Depending on the partitioning between respiratory muscles for the act of breathing, the distribution of blood between trunk and extremities can vary by up to 1 L. We conclude that during exercise the abdominal muscles and the diaphragm might play a role of an "auxiliary heart."