804 resultados para freshwater sensitivity


Relevância:

20.00% 20.00%

Publicador:

Resumo:

In the present longitudinal study, we investigated attachment quality in Portuguese mother–infant and in father–infant dyads, and evaluated whether attachment quality was related to parental sensitivity during parent–infant social interaction or to the amount of time each parent spent with the infant during play and in routine caregiving activities (e.g., feeding, bathing, play). The sample consisted of 82 healthy full-term infants (30 girls, 53 boys, 48 first born), and their mothers and fathers from mostly middle-class households. To assess parental sensitivity, mothers and fathers were independently observed during free play interactions with their infants when infants were 9 and 15 months old. The videotaped interactions were scored by masked coders using the Crittenden’s CARE-Index. When infants were 12 and 18 months old, mother–infant and father–infant dyads were videotaped during an adaptation of Ainsworth’s Strange Situation. Parents also described their level of involvement in infant caregiving activities using a Portuguese version of the McBride and Mills Parent Responsibility Scale. Mothers were rated as being more sensitive than fathers during parent–infant free play at both 9 and 15 months. There also was a higher prevalence of secure attachment in mother–infant versus father–infant dyads at both 12 and 18 months. Attachment security was predicted by the amount of time mothers and fathers were involved in caregiving and play with the infant, and with parents’ behavior during parent–infant free play.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

High speed trains, when crossing regions with abrupt changes in vertical stiffness of the track and/or subsoil, may generate excessive ground and track vibrations. There is an urgent need for specific analyses of this problem so as to allow reliable esimates of vibration amplitude. Full understanding of these phenomena will lead to new construction solutions and mitigation of undesirable features. In this paper analytical transient solutions of dynamic response of one-dimensional systems with sudden change of foundation stiffness are derived. Results are expressed in terms of vertical displacement. Sensitivity analysis of the response amplitude is also performed. The analytical expressions presented herein, to the authors’ knowledge, have not been published yet. Although related to one-dimensional cases, they can give useful insight into the problem. Nevertheless, in order to obtain realistic response, vehicle- rail interaction cannot be omitted. Results and conclusions are confirmed using general purpose commercial software ANSYS. In conclusion, this work contributes to a better understanding of the additional vibration phenomenon due to vertical stiffness variation, permitting better control of the train velocity and optimization of the track design.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This work reports on the results of double immunodiffusion (ID), counterimmunoelectrophoresis (CIE), complement fixation (CF) and indirect immunofluorescence (IIF) techniques in the serodiagnosis of paracoccidioidomycosis. The study was undertaken on four groups of individuals: 46 patients with untreated paracoccidioidomycosis, 22 patients with other deep mycoses, 30 with other infectious diseases (tuberculosis and cutaneous leishmaniasis) and 47 blood donors as negative controls. Data were obtained using Paracoccidioides brasiliensis antigens, i.e.,a yeast culture filtrate for ID, CIE and CF, and a yeast cell suspension for IIF. The sensitivity, specificity and efficiency values were measured according to GALEN & GAMBINO8.The gel precipitation tests (ID and CIE) showed the greatest sensitivity (91.3 and 95.6%, respectively), maximum specificity (100%) and the highest efficiency values when compared to the CF and IIF tests.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Dissertação apresentada para a obtenção do grau de doutor em Bioquímica pela Universidade Nova de Lisboa, Faculdade de Ciências e Tecnologia

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We report here the results obtained in epidemiologic surveys of histoplasmosis and paracoccidioidomycosis carried out in Brazil using the histoplasmin and paracoccidioidin delayed hypersensitivity skin tests. Most of these data have not been previously published in scientific journals and are now reported here in two tables respectively concerning histoplasmosis (88 surveys) and paracoccidioidomycosis (58 surveys). The guidelines to be followed in surveys of this nature are also commented upon.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

An epizootic outbreak of rabies occurred in 1995 in Ribeirão Preto, SP, with 58 cases of animal rabies (54 dogs, 3 cats and 1 bat) confirmed by the Pasteur Institute of São Paulo, and one human death. The need to provide care to a large number of people for the application of equine rabies immune globulin (ERIG) prevented the execution of the skin sensitivity test (SST) and often also the execution of desensitization, procedures routinely used up to that time at the Emergency Unit of the University Hospital of the Faculty of Medicine of Ribeirão Preto, University of São Paulo (EU-UHFMRP-USP), a reference hospital for the application of heterologous sera. In view of our positive experience of several years with the abolition of SST and of the use of premedication before the application of antivenom sera, we used a similar schedule for ERIG application. Of the 1489 victims of animal bites, 1054 (71%) received ERIG; no patient was submitted to SST and all received intravenously anti-histamines (anti-H1 + anti-H2) and corticosteroids before the procedure. The patients were kept under observation for 60 to 180 minutes and no adverse reaction was observed. On the basis of these results, since December 1995 ERIG application has been decentralized in Ribeirão Preto and has become the responsibility of the Emergency Unit of the University Hospital and the Central Basic Health Unit, where the same routine is used. Since then, 4216 patients have received ERIG (1818 at the Basic Health Unit and 2398 at the EU-UHFMRP), with no problems. The ideal would be the routine use of human rabies immune globulin (HRIG) in public health programs, but this is problematic, because of their high cost. However, while this does not occur, the use of SST is no longer justified at the time of application of ERIG, in view of the clinical evidence of low predictive value and low sensitivity of SST involving the application of heterologous sera. It is very important to point out that a negative SST result may lead the health team to a feeling of false safety that no adverse reaction will occur, but this is not true for the anaphylactoid reactions. The decision to use premedication, which is based on knowledge about anaphylaxis and on the pharmacology of the medication used, is left to the judgment of health professionals, who should always be prepared for eventual untoward events.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Falciparum malaria represents a serious and an increasing world public health problem due to the acquired parasite's resistance to the most available drugs. In some endemic areas, quinidine, a diastereoisomer of the antimalarial quinine, has been employed for replacing the latter. In order to evaluate the use of quinidine as an alternative to the increasing loss of quinine effectiveness in Brazilian P. falciparum strains, as has been observed in the Amazon area, we have assayed quinidine, quinine and chloroquine. The in vitro microtechnique was employed. All isolates showed to be highly resistant to chloroquine. Resistance to quinine was not noted although high MIC (minimal inhibitory concentration) values have been observed. These data corroborate the decreasing sensitivity to quinine in strains from Brazil. Quinidine showed IC50 from 0.053 to 4.577 mumol/L of blood while IC50 from 0.053 to 8.132 mumol/L of blood was estimated for quinine. Moreover, clearance of the parasitemia was observed in concentrations lower than that used for quinidine in antiarrhythmic therapy, confirming our previous data. The results were similar to African isolate.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Ecological Water Quality - Water Treatment and Reuse

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Cyanobacteria deteriorate the water quality and are responsible for emerging outbreaks and epidemics causing harmful diseases in Humans and animals because of their toxins. Microcystin-LR (MCT) is one of the most relevant cyanotoxin, being the most widely studied hepatotoxin. For safety purposes, the World Health Organization recommends a maximum value of 1 μg L−1 of MCT in drinking water. Therefore, there is a great demand for remote and real-time sensing techniques to detect and quantify MCT. In this work a Fabry–Pérot sensing probe based on an optical fibre tip coated with a MCT selective thin film is presented. The membranes were developed by imprinting MCT in a sol–gel matrix that was applied over the tip of the fibre by dip coating. The imprinting effect was obtained by curing the sol–gel membrane, prepared with (3-aminopropyl) trimethoxysilane (APTMS), diphenyl-dimethoxysilane (DPDMS), tetraethoxysilane (TEOS), in the presence of MCT. The imprinting effect was tested by preparing a similar membrane without template. In general, the fibre Fabry–Pérot with a Molecular Imprinted Polymer (MIP) sensor showed low thermal effect, thus avoiding the need of temperature control in field applications. It presented a linear response to MCT concentration within 0.3–1.4 μg L−1 with a sensitivity of −12.4 ± 0.7 nm L μg−1. The corresponding Non-Imprinted Polymer (NIP) displayed linear behaviour for the same MCT concentration range, but with much less sensitivity, of −5.9 ± 0.2 nm L μg−1. The method shows excellent selectivity for MCT against other species co-existing with the analyte in environmental waters. It was successfully applied to the determination of MCT in contaminated samples. The main advantages of the proposed optical sensor include high sensitivity and specificity, low-cost, robustness, easy preparation and preservation.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The diagnosis of American cutaneous leishmaniasis (ACL) is frequently based on clinical and epidemiological data associated with the results of laboratory tests. Some laboratory methods are currently being applied for the diagnosis of ACL, among them the indirect immunofluorescence reaction (IIFR), the Montenegro skin test (MST), histopathological examination, and the polymerase chain reaction (PCR). The performance of these methods varies in a considerable proportion of patients. After the standardization of an immunoenzymatic test (ELISA) for the detection of IgG in the serum of patients with ACL using a crude Leishmania braziliensis antigen, the results obtained were compared to those of other tests routinely used for the diagnosis. The tests revealed the following sensitivity, when analyzed separately: 85% for ELISA IgG, 81% for PCR, 64.4% for MST, 58.1% for IIFR, and 34% for the presence of parasites in the biopsy. ELISA was positive in 75% of patients with ACL presenting a negative MST, in 84.8% of ACL patients with negative skin or mucous biopsies for the presence of the parasite, and in 100% of cases with a negative PCR. Thus, ELISA presented a higher sensitivity than the other tests and was useful as a complementary method for the diagnosis of ACL.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

To compare sensitivity, specificity, positive predictive value (PPV) and negative predictive value (NPV) of self-diagnosis for head lice infestation with visual inspection, we conducted a study in an urban slum in Brazil. Individuals were asked about active head lice infestation (self-diagnosis); we performed visual inspection and thereafter wet combing (gold standard). Of the 175 individuals included, 77 (44%) had an active head lice infestation. For self-diagnosis, sensitivity (80.5%), specificity (91.8%), PPV (88.6%) and NPV (85.7%) were high. Sensitivity of visual inspection was 35.1%. Public health professionals can use self-diagnosis as a diagnostic tool, to estimate accurately prevalence of pediculosis in a community, and to monitor ongoing intervention strategies.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: Prospective testing for posttransplant circulating anti-HLA antibodies seems to be a critical noninvasive tool, but confirmatory data are lacking. MATERIALS AND METHODS: Over the last 3 years, peritubular capillary (PTC) C4d deposition was prospectively sought by an immunofluorescence technique applied to frozen tissue in biopsies obtained for allograft dysfunction. Screening for circulating anti-HLA class I/II alloantibodies (AlloAb) by the flow cytometric test was performed simultaneously. RESULTS: We evaluated 132 sets of biopsies and simultaneous serum samples. PTC C4d deposition was demonstrated in 15.9% (21/132) of biopsies. Circulating anti-HLA I/II AlloAb were detected in 25% (33/132) of serum samples. Employing receiver-operator characteristic (ROC) curves for all C4d-positive biopsies, screening for AlloAb showed a global specificity of 82% and sensitivity of 61.9%. When this analysis was restricted to biopsies obtained in the first month posttransplantation, the sensitivity increased to 81.8%, but the specificity decreased to 76.9%. After the first month posttransplantation, we observed sensitivity of 40.0% and a specificity of 86.4%. In the first month posttransplantation, all patients with a diagnosis of acute antibody-mediated rejection displayed circulating anti-HLA class I/II, but not always at the same time as the C4d-positive biopsy. CONCLUSIONS: In the first month posttransplantation, prospective monitoring of anti-HLA antibodies may be useful. The high sensitivity allows the identification of patients at risk, affording an earlier diagnosis of antibody-mediated rejection. After the first month, the test can be used to evaluate allograft dysfunction episodes, since positivity is highly suggestive of an antibody-mediated process.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVES: Evaluate the sensitivity/specificity of immunoperoxidase method in comparison with the standard immunofluorescence. MATERIAL AND METHODS: Retrospective review of 87 biopsies made for allograft dysfunction. Immunofluorescence (IF) was performed in frozen allograft biopsies using monoclonal antibody anti-C4d from Quidel®. The indirect immunoperoxidase (IP) technique was performed in paraffin-embebbed tissue with polyclonal antiserum from Serotec®. Biopsies were independently evaluated by two nephropathologist according Banff 2007 classification. RESULTS: By IF, peritubular C4d deposition were detected in 60 biopsies and absent in 27 biopsies. The evaluation of biopsy by IP was less precise due to the presence of background and unspecific staining. We find 13.8% (12/87) of false negative and Banff classification concordance in 79.3% (69/87) of cases (table1). The ROC curve study reveal a specificity of 100% and sensitivity of 80.0 % of IP method in relation to the gold standard (area under curve:0.900; 95% Confidence interval :0.817-0.954; p=0.0001). Banff Classification C4d Cases Immunofluorescence Immunoperoxidase n =87 Diffuse Negative 3 (3.4%) Focal Negative 9 (10.3%) Negative Negative 27 (31.0%) Diffuse Diffuse 33 (37.9%) Focal Focal 9 (10.3%) Diffuse Focal 6 (6.9%) CONCLUSION: The IP method presents a good specificity, but lesser sensitivity to C4d detection in allograft dysfunction. The evaluation is more difficult, requiring more experience of the observer than IF method. If frozen tissue is unavailable, the use of IP for C4d detection is acceptable.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The toxic effect of binary and tertiary combinations of Euphorbia hirta Linn latex powder with other plant molluscicidal compounds, were evaluated against the freshwater snails Lymnaea (Radix) acuminata and Indoplanorbis exustus in pond. These combinations showed significant time and dose dependent effect against both the snails. These compounds at higher doses were also lethal to freshwater fish Channa punctatus (Bloch) (Channidae {Ophicephalidae}), which shares the habitat with these snails, but the LC90 (24h) doses of snails have no apparent killing properties in fish populations when treated in mixed population of snails and fish.