413 resultados para fluence verbale
Resumo:
Purpose: The dose delivery accuracy of 30 clinical step and shoot intensity modulated radiation therapy plans was investigated using the single integrated multileaf collimator controller of the Varian Truebeam linear accelerator (linac) (Varian Medical Systems, Palo Alto, CA) and compared with the dose delivery accuracy on a previous generation Varian 2100CD C-Series linac.
Methods and Materials: Ten prostate, 10 prostate and pelvic node, and 10 head-and-neck cases were investigated in this study. Dose delivery accuracy on each linac was assessed using Farmer ionization chamber point dose measurements, 2-dimensional planar ionization chamber array measurements, and the corresponding Varian dynamic log files. Absolute point dose measurements, fluence delivery accuracy, leaf position accuracy, and the overshoot effect were assessed for each plan.
Results: Absolute point dose delivery accuracy increased by 1.5% on the Truebeam compared with the 2100CD linac. No improvement in fluence delivery accuracy between the linacs, at a gamma criterion of 3%/3 mm was measured using the 2-dimensional ionization chamber array, with median (interquartile range) gamma passing rates of 98.99% (97.70%-99.72%) and 99.28% (98.26%-99.75%) for the Truebeam and 2100CD linacs, respectively. Varian log files also showed no improvement in fluence delivery between the linacs at 3%/3 mm, with median gamma passing rates of 99.97% (99.93%-99.99%) and 99.98% (99.94%-100%) for the Truebeam and 2100CD linacs, respectively. However, log files revealed improved leaf position accuracy and fluence delivery at 1%/1 mm criterion on the Truebeam (99.87%; 99.78%-99.94%) compared with the 2100CD linac (97.87%; 91.93%-99.49%). The overshoot effect, characterized on the 2100CD linac, was not observed on the Truebeam.
Conclusions: The integrated multileaf collimator controller on the Varian Truebeam improves clinical treatment delivery accuracy of step and shoot intensity modulated radiation therapy fields compared with delivery on a Varian C-series linac. © 2014.
Resumo:
This study aims to evaluate the use of Varian radiotherapy dynamic treatment log (DynaLog) files to verify IMRT plan delivery as part of a routine quality assurance procedure. Delivery accuracy in terms of machine performance was quantified by multileaf collimator (MLC) position errors and fluence delivery accuracy for patients receiving intensity modulated radiation therapy (IMRT) treatment. The relationship between machine performance and plan complexity, quantified by the modulation complexity score (MCS) was also investigated. Actual MLC positions and delivered fraction of monitor units (MU), recorded every 50 ms during IMRT delivery, were extracted from the DynaLog files. The planned MLC positions and fractional MU were taken from the record and verify system MLC control file. Planned and delivered beam data were compared to determine leaf position errors with and without the overshoot effect. Analysis was also performed on planned and actual fluence maps reconstructed from the MLC control file and delivered treatment log files respectively. This analysis was performed for all treatment fractions for 5 prostate, 5 prostate and pelvic node (PPN) and 5 head and neck (H&N) IMRT plans, totalling 82 IMRT fields in ∼5500 DynaLog files. The root mean square (RMS) leaf position errors without the overshoot effect were 0.09, 0.26, 0.19 mm for the prostate, PPN and H&N plans respectively, which increased to 0.30, 0.39 and 0.30 mm when the overshoot effect was considered. Average errors were not affected by the overshoot effect and were 0.05, 0.13 and 0.17 mm for prostate, PPN and H&N plans respectively. The percentage of pixels passing fluence map gamma analysis at 3%/3 mm was 99.94 ± 0.25%, which reduced to 91.62 ± 11.39% at 1%/1 mm criterion. Leaf position errors, but not gamma passing rate, were directly related to plan complexity as determined by the MCS. Site specific confidence intervals for average leaf position errors were set at -0.03-0.12 mm for prostate and -0.02-0.28 mm for more complex PPN and H&N plans. For all treatment sites confidence intervals for RMS errors with the overshoot was set at 0-0.50 mm and for the percentage of pixels passing a gamma analysis at 1%/1 mm a confidence interval of 68.83% was set also for all treatment sites. This work demonstrates the successful implementation of treatment log files to validate IMRT deliveries and how dynamic log files can diagnose delivery errors not possible with phantom based QC. Machine performance was found to be directly related to plan complexity but this is not the dominant determinant of delivery accuracy.
Resumo:
Efficacy of inverse planning is becoming increasingly important for advanced radiotherapy techniques. This study's aims were to validate multicriteria optimization (MCO) in RayStation (v2.4, RaySearch Laboratories, Sweden) against standard intensity-modulated radiation therapy (IMRT) optimization in Oncentra (v4.1, Nucletron BV, the Netherlands) and characterize dose differences due to conversion of navigated MCO plans into deliverable multileaf collimator apertures. Step-and-shoot IMRT plans were created for 10 patients with localized prostate cancer using both standard optimization and MCO. Acceptable standard IMRT plans with minimal average rectal dose were chosen for comparison with deliverable MCO plans. The trade-off was, for the MCO plans, managed through a user interface that permits continuous navigation between fluence-based plans. Navigated MCO plans were made deliverable at incremental steps along a trajectory between maximal target homogeneity and maximal rectal sparing. Dosimetric differences between navigated and deliverable MCO plans were also quantified. MCO plans, chosen as acceptable under navigated and deliverable conditions resulted in similar rectal sparing compared with standard optimization (33.7 ± 1.8Gy vs 35.5 ± 4.2Gy, p = 0.117). The dose differences between navigated and deliverable MCO plans increased as higher priority was placed on rectal avoidance. If the best possible deliverable MCO was chosen, a significant reduction in rectal dose was observed in comparison with standard optimization (30.6 ± 1.4Gy vs 35.5 ± 4.2Gy, p = 0.047). Improvements were, however, to some extent, at the expense of less conformal dose distributions, which resulted in significantly higher doses to the bladder for 2 of the 3 tolerance levels. In conclusion, similar IMRT plans can be created for patients with prostate cancer using MCO compared with standard optimization. Limitations exist within MCO regarding conversion of navigated plans to deliverable apertures, particularly for plans that emphasize avoidance of critical structures. Minimizing these differences would result in better quality treatments for patients with prostate cancer who were treated with radiotherapy using MCO plans.
Resumo:
Surface modification of thin aluminium films is both produced and characterised by exciting surface plasmon polaritons in an attenuated total reflection geometry: silica prism/aluminium/aluminium oxide system. The modification is performed, under ambient conditions, by exposure to a low fluence (
Resumo:
Thin, oxidised Al films grown an one face of fused silica prisms are exposed. tinder ambient conditions, to single shots from an excimer laser operating at wavelength 248 nm. Preliminary characterisation of the films using attenuated total reflection yields optical and thickness data for the Al and Al oxide layers; this step facilitates the subsequent, accurate tuning of the excimer laser pulse to the: surface plasmon resonance at the Al/(oxide)/air interface and the calculation of the fluence actually absorbed by the thin film system. Ablation damage is characterised using scanning electron, and atomic force microscopy. When the laser pulse is incident, through the prism on the sample at less than critical angle, the damage features are molten in nature with small islands of sub-micrometer dimension much in evidence, a mechanism of film melt-through and subsegment blow-off due to the build up of vapour pressure at the substrate/film interface is appropriate. By contrast, when the optical input is surface plasmon mediated, predominately mechanical damage results with the film fragmenting into large flakes of dimensions on the order of 10 mu m. It is suggested that the ability of surface plasmons to transport energy leads to enhanced, preferential absorption of energy at defect sites causing stress throughout the film which exceeds the ultimate tensile stress for the film: this in turn leads to film break-up before melting can onset. (C) 1998 Elsevier Science B.V.
Resumo:
Surface plasmon enhancement of laser ablation of thin Al films is examined with a view to its application in metal film patterning and nano-structuring. Al films, deposited on silica prisms, are first characterized by attenuated total reflection using a broadband UV source and appropriate interference filter. The films are subsequently subjected to excimer laser radiation of wavelength 248 nm under conditions both of direct incidence from the air side of the film, and of surface plasmon excitation in which light is incident through the prism at greater than critical angle. For a given level of ablation damage in a particular film the fluence required using the surface plasmon technique is 3-5 times less than that needed when direct incidence is used. This is roughly in line with the energy absorbed in the film. From a practical standpoint it is clear that ablation of metal films can be achieved with much lower fluences than has hitherto been possible, thus reducing the requirements on laser output and relaxing the power handling constraints on any input optical elements.
Resumo:
The motivation for this study was to reduce physics workload relating to patient- specific quality assurance (QA). VMAT plan delivery accuracy was determined from analysis of pre- and on-treatment trajectory log files and phantom-based ionization chamber array measurements. The correlation in this combination of measurements for patient-specific QA was investigated. The relationship between delivery errors and plan complexity was investigated as a potential method to further reduce patient-specific QA workload. Thirty VMAT plans from three treatment sites - prostate only, prostate and pelvic node (PPN), and head and neck (H&N) - were retrospectively analyzed in this work. The 2D fluence delivery reconstructed from pretreatment and on-treatment trajectory log files was compared with the planned fluence using gamma analysis. Pretreatment dose delivery verification was also car- ried out using gamma analysis of ionization chamber array measurements compared with calculated doses. Pearson correlations were used to explore any relationship between trajectory log file (pretreatment and on-treatment) and ionization chamber array gamma results (pretreatment). Plan complexity was assessed using the MU/ arc and the modulation complexity score (MCS), with Pearson correlations used to examine any relationships between complexity metrics and plan delivery accu- racy. Trajectory log files were also used to further explore the accuracy of MLC and gantry positions. Pretreatment 1%/1 mm gamma passing rates for trajectory log file analysis were 99.1% (98.7%-99.2%), 99.3% (99.1%-99.5%), and 98.4% (97.3%-98.8%) (median (IQR)) for prostate, PPN, and H&N, respectively, and were significantly correlated to on-treatment trajectory log file gamma results (R = 0.989, p < 0.001). Pretreatment ionization chamber array (2%/2 mm) gamma results were also significantly correlated with on-treatment trajectory log file gamma results (R = 0.623, p < 0.001). Furthermore, all gamma results displayed a significant correlation with MCS (R > 0.57, p < 0.001), but not with MU/arc. Average MLC position and gantry angle errors were 0.001 ± 0.002 mm and 0.025° ± 0.008° over all treatment sites and were not found to affect delivery accuracy. However, vari- ability in MLC speed was found to be directly related to MLC position accuracy. The accuracy of VMAT plan delivery assessed using pretreatment trajectory log file fluence delivery and ionization chamber array measurements were strongly correlated with on-treatment trajectory log file fluence delivery. The strong corre- lation between trajectory log file and phantom-based gamma results demonstrates potential to reduce our current patient-specific QA. Additionally, insight into MLC and gantry position accuracy through trajectory log file analysis and the strong cor- relation between gamma analysis results and the MCS could also provide further methodologies to both optimize the VMAT planning and QA process.
Resumo:
The use of high linear energy transfer radiations in the form of carbon ions in heavy ion beam lines or alpha particles in new radionuclide treatments has increased substantially over the past decade and will continue to do so due to the favourable dose distributions they can offer versus conventional therapies. Previously it has been shown that exposure to heavy ions induces pan-nuclear phosphorylation of several DNA repair proteins such as H2AX and ATM in vitro. Here we describe similar effects of alpha particles on ex vivo irradiated primary human peripheral blood lymphocytes. Following alpha particle irradiation pan-nuclear phosphorylation of H2AX and ATM, but not DNA-PK and 53BP1, was observed throughout the nucleus. Inhibition of ATM, but not DNA-PK, resulted in the loss of pan-nuclear phosphorylation of H2AX in alpha particle irradiated lymphocytes. Pan-nuclear gamma-H2AX signal was rapidly lost over 24h at a much greater rate than foci loss. Surprisingly, pan-nuclear gamma-H2AX intensity was not dependent on the number of alpha particle induced double strand breaks, rather the number of alpha particles which had traversed the cell nucleus. This distinct fluence dependent damage signature of particle radiation is important in both the fields of radioprotection and clinical oncology in determining radionuclide biological dosimetry and may be indicative of patient response to new radionuclide cancer therapies.
Resumo:
Photodynamic therapy and photodynamic antimicrobial chemotherapy are widely used, but despite this, the relationships between fluence, wavelength of irradiation and singlet oxygen (1O2) production are poorly understood. To establish the relationships between these factors in medically-relevant materials, the effect of fluence on 1O2 production from a tetrakis(4-N-methylpyridyl)porphyrin (TMPyP)-incorporated 2-hydroxyethyl methacrylate: methyl methacrylate: methacrylic acid (HEMA:MMA:MAA) copolymer, a total energy of 50.48 J/cm², was applied at varying illumination power, and times. 1O2 production was characterised using anthracene-9,10-dipropionic acid, disodium salt (ADPA) using a recently described method. Using two light sources, a white LED array and a white halogen source, the LED array was found to produce less 1O2 than the halogen source when the same power (over 500-600 nm) and time conditions were applied. Importantly, it showed that the longest wavelength Q band (590 nm) is primarily responsible for 1O2 generation, and that a linear relationship exists between increasing power and time and the production of singlet oxygen.
Resumo:
Photodynamic therapy and photodynamic antimicrobial chemotherapy are widely used, but despite this, the relationships between fluence, wavelength of irradiation and singlet oxygen ((1) O2 ) production are poorly understood. To establish the relationships between these factors in medically relevant materials, the effect of fluence on (1) O2 production from a tetrakis(4-N-methylpyridyl)porphyrin (TMPyP)-incorporated 2-hydroxyethyl methacrylate: methyl methacrylate: methacrylic acid (HEMA: MMA:MAA) copolymer, a total energy of 50.48 J/cm(2) , was applied at varying illumination power, and times. (1) O2 production was characterized using anthracene-9,10-dipropionic acid, disodium salt (ADPA) using a recently described method. Using two light sources, a white LED array and a white halogen source, the LED array was found to produce less (1) O2 than the halogen source when the same power (over 500 - 600 nm) and time conditions were applied. Importantly, it showed that the longest wavelength Q band (590 nm) is primarily responsible for (1) O2 generation, and that a linear relationship exists between increasing power and time and the production of singlet oxygen.
Resumo:
Este estudo investiga a influência da interação imagem-texto de três álbuns ilustrados de língua inglesa no desenvolvimento do repertório linguístico de crianças pré-leitoras. Numa metodologia de estudo de caso, adotando uma abordagem qualitativa e socio construtivista num contexto real de educação pré-escolar, três grupos de crianças portuguesas foram filmados ao longo de várias sessões de leitura repetida em voz alta e em inglês, e de sessões de recontos trabalhados em pequenos grupos. Após a transcrição das gravações, o corpus resultante foi analisado com base numa teoria fundamentada de compreensão literária e em escalas de leitura emergente. Os resultados mostraram que as crianças adotaram uma postura fortemente analítica face aos álbuns, direcionando as suas respostas para as ilustrações e usando-as como apoio na construção de significados. Os resultados mostraram também que cada interanimação visual e verbal ofereceu diversas oportunidades para o uso das línguas em presença, o português e o inglês, tendo o formato e a estrutura inerentes a cada álbum contribuído de forma muito relevante para as respostas das crianças. Contudo, os álbuns com uma dinâmica imagem-texto mais complexa proporcionaram um maior envolvimento das crianças, provocando mais discussão em torno das ilustrações e criando mais oportunidades para mediação do uso da segunda língua. Os resultados revelaram ainda a importância da interação durante as leituras repetidas, na compreensão e na análise narrativa, num processo de desenvolvimento da linguagem. Com base nestes resultados, apontam-se conclusões, com implicações para os contextos educativos, quer ao nível da língua materna, quer ao nível da segunda língua, nomeadamente em relação: à seleção de álbuns e à valorização das ilustrações e ainda à importância de leituras repetidas em voz alta e à discussão realizada pelas crianças.
Resumo:
Os nitretos binários semicondutores do grupo III, e respetivos compostos, são vastamente estudados devido à sua possível aplicabilidade em dispositivos optoeletrónicos, tais como díodos emissores de luz (LEDs) e LASERs, assim como dispositivos para a eletrónica de elevadas temperatura, potência e frequência. Enquanto se concretizou a comercialização na última década de LEDs e LASERs recorrendo ao ternário In1-yGayN, estudos das propriedades fundamentais estruturais e óticas, assim como de técnicas de processamento no desenvolvimento de novas aplicações de outros ternários do grupo III-N encontram-se na sua fase inicial. Esta tese apresenta a investigação experimental de filmes finos epitaxiais de Al1-xInxN crescidos sobre camadas tampão de GaN e de Al1-yGayN e o estudo do recozimento e implantação de super-redes (SL) compostas por pontos quânticos de GaN (QD) envolvidos por camadas de AlN. Apesar do hiato energético do Al1-xInxN poder variar entre os 0,7 eV e os 6,2 eV e, por isso, numa gama, consideravelmente superior à dos ternários Al1-yGayN e InyGa1-yN, o primeiro é o menos estudado devido a dificuldades no crescimento de filmes com elevada qualidade cristalina. É efetuada, nesta tese, uma caracterização estrutural e composicional de filmes finos de Al1-xInxN crescidos sobre camadas tampão de GaN e de Al1-yGayN usando técnicas de raios-X, feixe de iões e de microscopia. Mostra-se que o Al1-xInxN pode ser crescido com elevada qualidade cristalina quando a epitaxia do crescimento se aproxima da condição de rede combinada do Al1-xInxN e da camada tampão (GaN ou Al1-yGayN), isto é, com conteúdo de InN de ~18%, quando crescido sobre uma camada de GaN. Quando o conteúdo de InN é inferior/superior à condição de rede combinada, fenómenos de relaxação de tensão e deterioração do cristal tais como o aumento da rugosidade de superfície prejudicam a qualidade cristalina do filme de Al1-xInxN. Observou-se que a qualidade dos filmes de Al1-xInxN depende fortemente da qualidade cristalina da camada tampão e, em particular, da sua morfologia e densidade de deslocações. Verificou-se que, dentro da exatidão experimental, os parâmetros de rede do ternário seguem a lei empírica de Vegard, ou seja, variam linearmente com o conteúdo de InN. Contudo, em algumas amostras, a composição determinada via espetrometria de retrodispersão de Rutherford e difração e raios-X mostra valores discrepantes. Esta discrepância pode ser atribuída a defeitos ou impurezas capazes de alterar os parâmetros de rede do ternário. No que diz respeito às SL dos QD e camadas de AlN, estudos de recozimento mostraram elevada estabilidade térmica dos QD de GaN quando estes se encontram inseridos numa matriz de AlN. Por implantação iónica, incorporou-se európio nestas estruturas e, promoveu-se a ativação ótica dos iões de Eu3+ através de tratamentos térmicos. Foram investigados os efeitos da intermistura e da relaxação da tensão ocorridos durante o recozimento e implantação nas propriedades estruturais e óticas. Verificou-se que para fluências elevadas os defeitos gerados por implantação são de difícil remoção. Contudo, a implantação com baixa fluência de Eu, seguida de tratamento térmico, promove uma elevada eficiência e estabilidade térmica da emissão vermelha do ião lantanídeo incorporado nos QD de GaN. Estes resultados são, particularmente relevantes, pois, na região espetral indicada, a eficiência quântica dos LEDs convencionais de InGaN é baixa.
Resumo:
A inativação fotodinâmica tem sido usada com sucesso na inativação de microorganismos. Diversos aspetos da inativação fotodinâmica foram já estudados para diferentes microrganismos, contudo, existe ainda pouca informação disponível no que diz respeito à inativação de bacteriófagos por processos fotodinâmicos. Este trabalho pretendeu elucidar e avaliar vários aspetos da fotoinativação de vírus, em particular de bacteriófagos, incluindo (i) o efeito de diversos parâmetros de luz utilizados na fotoinativação de bacteriófagos; (ii) a eficiência da inativação fotodinâmica de diferentes tipos de bacteriófagos (fagos do tipo DNA e RNA); (iii) o principal mecanismo através do qual a inativação fotodinâmica tem lugar; (iv) o efeito da fotoinativação nas proteínas do bacteriófago; e (v) o possível desenvolvimento de resistência e recuperação da viabilidade após vários tratamentos fotodinâmicos consecutivos. Para avaliar o efeito dos diferentes parâmetros de luz, suspensões fágicas com 107 UFP mL-1 foram irradiadas com diferentes fontes e doses de luz, intensidades luminosas e tempos de irradiação (30,90 e 270 min) na presença de 0,5; 1,0 e 5,0 μM dos derivados porfirínicos catiónicos Tri- Py+-Me-PF e Tetra-Py+-Me. A eficiência da fotoinativação de diferentes fagos do tipo DNA e RNA, foi avaliada através da irradiação da suspensão fágica com luz branca (40 W m-2) durante 270 min na presença de 0,5 e 5,0 μM do derivado porfirínico Tri-Py+-Me-PF, respetivamente para os fagos do tipo RNA e DNA. O mecanismo através do qual a fotoinativação de fagos de DNA (fago do tipo T4) e de RNA (fago Qb) tem lugar foi avaliado por exposição da suspensão fágica à luz branca com uma potência de 40 W m-2, na presença de fotossensibilizador (Tri-Py+-Me-PF e Tetra-Py+-Me) e inibidores, quer do oxigénio singuleto (azida de sódio e L-histidina) quer de radicais livres (Dmanitol e L-cisteína). Os danos nas proteínas do fago do tipo T4, induzidos pelas espécies reativas de oxigénio geradas por 5,0 μM Tri-Py+-Me-PF, foram avaliados pelo método convencional de SDS-PAGE e por espectroscopia de infravermelho. O possível desenvolvimento de resistência e recuperação da viabilidade após a inativação fotodinâmica dos bacteriófagos foi avaliado após dez ciclos consecutivos de tratamento fotodinâmico incompletos (120 min sob irradiação de luz branca a uma potência de 40 W m-2) na presença de 5,0 μM do derivado porfirínico Tri-Py+-Me-PF. Os resultados deste trabalho mostraram que (i) quando uma quantidade de energia (dose de luz) determinada foi aplicada numa suspensão fágica, a partir de uma mesma fonte irradiação, a fotoinactivação do fago foi tanto mais eficiente quanto mais baixa foi a potência luminosa aplicada; (ii) os bacteriófagos foram eficientemente inativados até ao limite de deteção (redução de 6-7 log); (ii) os fagos do tipo RNA foram inativados mais facilmente do que os fagos do tipo DNA (tempos de exposição mais curtos e com concentração de fotossensibilizador dez vezes menor do que a usada para inativar os fagos do tipo DNA); (iii) o mecanismo do tipo II (via produção de oxigénio singuleto) foi o principal mecanismo através do qual a fotoinativação dos bacteriófagos teve lugar; (iv) foi possível detectar danos no perfil proteico após tratamento fotodinâmico e a espectroscopia de infravermelho apresentou-se como uma metodologia promissora de screening para avaliação dos danos induzidos pela inativação fotodinâmica em proteínas; e (v) após dez ciclos consecutivos de tratamento fotodinâmico, o fago do tipo T4 não revelou nenhum tipo de resistência ao tratamento fotodinâmico nem recuperou a sua viabilidade. Como conclusão, a inativação fotodinâmica microbiana é uma tecnologia bastante eficaz para a fotoinativação de bacteriófagos do tipo DNA e RNA sem invólucro, a qual pode ser considerada como uma alternativa ao tratamento convencional com agentes antivíricos, mesmo com intensidades luminosas baixas, sem o risco associado de desenvolvimento de mecanismos de resistência.
Resumo:
Les troubles du spectre de l'autisme (TSAR se caractérisent par des altérations au niveau de la réciprocité des interactions sociales, des habiletés de communication verbale et non verbale, ainsi que la présence de comportements et champs d'intérêts stéréotypés. Compte tenu des conclusions décrivant leurs parents comme vivant plus de stress comparativement aux parents d'enfants non diagnostiqués sur le spectre de l'autisme, il devient nécessaire d'offrir un soutien susceptible d'alléger leur quotidien et celui de leur enfant. Le recueil de données sur l'application d'une intervention novatrice qu'est l'intégration permanente d'un chien d'assistance au sein du milieu familial offrirait une contribution considérable basée sur les conclusions des études précédentes. Le modèle conceptuel de la présente étude réfère aux transactions entre la régulation diurne du cortisol, la perception de stress parental, la sévérité des atteintes comportementales de l'enfant ainsi que les représentations d'attachement de la mère. L'approche analytique s'oriente ainsi sur le caractère multidimensionnel des variables et s'intéresse particulièrement aux différences intra-individuelles dans l'adaptation parentale illustrée par l'activité totale de cortisol sur une période de 15 semaines. L'ensemble des données soulève la présence d'une sous-activation de l'axe 1-IPA ainsi qu'une perception de niveaux élevés de stress parental. Suivant une approche centrée sur la personne, les analyses ont permis de dégager deux profils distincts de régulation basés sur l'activité totale de cortisol salivaire. La présence du chien d'assistance au sein de la famille apporte des changements notables décrits par une diminution de la réponse du cortisol au réveil spécifique au sous-groupe de mères ayant un profil de sécrétion supérieur. L'étude apporte une démonstration empirique d'une hétérogénéité des patrons de régulation hormonale issus d'un même échantillon caractérisé par le vécu d'un stress chronique. L'efficacité d'une nouvelle forme d'intervention pouvant soulager les difficultés rencontrées par les parents est discutée selon un point de vue transdisciplinaire.
Resumo:
The objectives of this paper are to ascertain the main factors involved in the phenological mechanism of alder flowering in Central Europe by understanding the in - fluence of the main meteorological parameters, the North Atlantic Oscillation (NAO) effect and the study of the Chill and Heat requirements to overcome dormancy. Airborne pollen (1995–2007) was collected in Poznań (Poland) by means a volumetric spore trap. Temperatures for February, and January and February averages of the NAO are generally key factors affecting the timing of the alder pollen seasons. Chilling accumulation (which started in Poznań at the beginning of November, while the end took place during the month of January) of 985 CH with a threshold temperature of -0.25ºC, followed by 118 GDDºC with a threshold temperature of 0.5ºC, were necessary to overcome dormancy and produce the onset of flowering. The calculated dormancy requirements, mean tem - peratures of the four decades of the year, and January and February average NAO index recorded during the period before flowering, were used to construct linear and multiple regression models in order to forecast the start date of the alder pollen seasons Its ac - curacy was tested using data from 2007, and the difference between the predicted and observed dates ranged from 3–7 days