Despite increasingly stringent energy performance regulations for new homes, southeast Queensland has a high and growing penetration of, and reliance on, air conditioners to provide thermal comfort to housing inhabitants. This reliance impacts on electricity infrastructure investment which is the key driving force behind rising electricity prices. This paper reports initial findings of a research project that seeks to better understand three key issues: (i) how families manage their thermal comfort in summer and how well their homes limit overheating; (ii) the extent to which the homes have been constructed according to the building approval documentation; and (iii) the impact that these issues have on urban design, especially in relation to electricity infrastructure in urban developments.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Irradiance profile around the receiver tube (RT) of a parabolic trough collector (PTC) is a key effect of optical performance that affects the overall energy performance of the collector. Thermal performance evaluation of the RT relies on the appropriate determination of the irradiance profile. This article explains a technique in which empirical equations were developed to calculate the local irradiance as a function of angular location of the RT of a standard PTC using a vigorously verified Monte Carlo ray tracing model. A large range of test conditions including daily normal insolation, spectral selective coatings and glass envelop conditions were selected from the published data by Dudley et al. [1] for the job. The R2 values of the equations are excellent that vary in between 0.9857 and 0.9999. Therefore, these equations can be used confidently to produce realistic non-uniform boundary heat flux profile around the RT at normal incidence for conjugate heat transfer analyses of the collector. Required values in the equations are daily normal insolation, and the spectral selective properties of the collector components. Since the equations are polynomial functions, data processing software can be employed to calculate the flux profile very easily and quickly. The ultimate goal of this research is to make the concentrating solar power technology cost competitive with conventional energy technology facilitating its ongoing research.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Links between human health and wellbeing, and contact with nature are well understood in the fields of health and psychology, and more recently are gaining attention in the built environment industry. In 1984, E.O. Wilson coined the term ‘biophilia’ to describe the tendency for humans to have an innately emotional response to other living organisms. A growing number of researchers around the world are now exploring the impact of nature in urban environments (i.e. biophilic urbanism) on the human condition, including many indicators of human physical and mental health, recovery and performance. There is also an emergence of research on the potential for biophilic urbanism to address other challenges related to climate change mitigation and adaptation. This paper presents key findings from a review of key literature to date, discussing opportunities for biophilic urbanism to both improve occupant experience and performance, as well as addressing other sustainability objectives including climate change mitigation and adaptation. The paper presents an emerging framework for considering biophilic design opportunities and highlights implications for the built environment industry. This research draws on an Australian project considering biophilic urbanism in the response to climate change, within the Sustainable Built Environment National Research Centre. This includes findings from a literature review, a survey pilot study and two workshops undertaken in Perth and Brisbane with a variety of industry and government stakeholders.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

[ES]El documento que se presenta tiene como finalidad realizar la certificación energética de una vivienda perteneciente a un bloque residencial situado en Leioa. Además, se estudian diferentes medidas para obtener un mejor comportamiento térmico y se analiza la viabilidad económica de las mismas

Relevância:

60.00% 60.00%

Publicador:

Resumo:

O potencial eólico do Brasil, de vento firme e com viabilidade econômica de aproveitamento, é de 143 GW. Isso equivale ao dobro de toda a capacidade da geração já instalada no país. No Brasil, a energia eólica tem uma sazonalidade complementar à energia hidrelétrica, porque os períodos de melhor condição de vento coincidem com os de menor capacidade dos reservatórios. O projeto desenvolvido neste trabalho nasceu de uma chamada pública do FINEP, e sob os auspícios do recém criado CEPER. Ao projeto foi incorporado um caráter investigativo, de contribuição científica original, resultando em um produto de tecnologia inovadora para aerogeradores de baixa potência. Dentre os objetivos do projeto, destacamos a avaliação experimental de turbinas eólicas de 5000 W de potência. Mais especificamente, dentro do objetivo geral deste projeto estão incluídas análise estrutural, análise aerodinâmica e análise de viabilidade de novos materiais a serem empregados. Para cada uma das diferentes áreas de conhecimento que compõem o projeto, será adotada a metodologia mais adequada. Para a Análise aerodinâmica foi realizada uma simulação numérica preliminar seguida de ensaios experimentais em túnel de vento. A descrição dos procedimentos adotados é apresentada no Capítulo 3. O Capítulo 4 é dedicado aos testes elétricos. Nesta etapa, foi desenvolvido um banco de testes para obtenção das características específicas das máquinas-base, como curvas de potência, rendimento elétrico, análise e perdas mecânicas e elétricas, e aquecimento. Este capítulo termina com a análise crítica dos valores obtidos. Foram realizados testes de campo de todo o conjunto montado. Atualmente, o aerogerador de 5kW encontra-se em operação, instrumentado e equipado com sistema de aquisição de dados para consolidação dos testes de confiabilidade. Os testes de campo estão ocorrendo na cidade de Campos, RJ, e abrangeram as seguintes dimensões de análise; testes de eficiência para determinação da curva de potência, níveis de ruído e atuação de dispositivos de segurança. Os resultados esperados pelo projeto foram atingidos, consolidando o projeto de um aerogerador de 5000W.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The coupled heat, air and moisture transfer between building envelopes and indoor air is complicated, and has a significant influence on the indoor environment and the energy performance of buildings. In the paper, a model for predicting coupled multi-zone hygrothermal-airflow transfer is presented. Both heat and moisture transfer in the building envelope and multi-zone indoor airflow are simultaneously considered; their interactions are modeled. The coupled system model is implemented into Matlab–Simulink, and is validated by using a series of testing tools and experiments. The new program is applied to investigate the moisture transfer effect on indoor air humidity and building energy consumption in different climates (hot-humid, temperate and hot-dry climates). The results show that not accounting for hygrothermal effects in modeling will result in overestimation of energy costs for hot and humid climate situations and possible over sizing of plant leading to inefficient operation.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The Kyoto Protocol and the European Energy Performance of Buildings Directive put an onus on governments
and organisations to lower carbon footprint in order to contribute towards reducing global warming. A key
parameter to be considered in buildings towards energy and cost savings is its indoor lighting that has a major
impact on overall energy usage and Carbon Dioxide emissions. Lighting control in buildings using Passive
Infrared sensors is a reliable and well established approach; however, the use of only Passive Infrared does not
offer much savings towards reducing carbon, energy, and cost. Accurate occupancy monitoring information can
greatly affect a building’s lighting control strategy towards a greener usage. This paper presents an approach for
data fusion of Passive Infrared sensors and passive Radio Frequency Identification (RFID) based occupancy
monitoring. The idea is to have efficient, need-based, and reliable control of lighting towards a green indoor
environment, all while considering visual comfort of occupants. The proposed approach provides an estimated
13% electrical energy savings in one open-plan office of a University building in one working day. Practical
implementation of RFID gateways provide real-world occupancy profiling data to be fused with Passive
Infrared sensing towards analysis and improvement of building lighting usage and control.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

This work provides a first-time-study of Azepanium-based ionic liquids (ILs) as electrolyte components for electrochemical double layer capacitors (EDLCs). Herein, two Azepanium-based ILs, namely N-methyl, N-butyl-azepanium bis(trifluoromethanesulfonyl)imide (Azp(14)TFSI) and N-methyl, N-hexyl-azepanium bis(trifluoromethanesulfonyl)imide (Azp(16)TFSI) were compared with the established IL N-butyl, N-methylpyrrolidinium bis(trifluoromethanesulfonyl)imide (Pyr(14)TFSI) in terms of viscosity, conductivity, thermal stability and electrochemical behavior in EDLC systems. The ILs' operative potentials were found to be comparable, leading to operative voltages up to 3.5 V without significant electrolyte degradation. 

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Glazed Double Skin Facades (DSF) offer the potential to improve the performance of all-glass building skins, common to commercial office buildings in which full facade glazing has almost become the standard. Single skin glazing results in increased heating and cooling costs over opaque walls, due to lower thermal resistance of glass, and the increased impact of solar gain through it. However, the performance benefit of DSF technology continues to be questioned and its operation poorly understood, particularly the nature of airflow through the cavity. This paper deals specifically with the experimental analysis of the air flow characteristics in an automated double skin façade. The benefit of the DSF as a thermal buffer, and to limit overheating is evaluated through analysis of an extensive set of parameters including air and surface temperatures at each level in the DSF, airflow readings in the cavity and at the inlet and outlet, solar and wind data, and analytically derived pressure differentials. The temperature and air-flow are monitored in the cavity of a DSF using wireless sensors and hot wire anemometers respectively. Automated louvre operation and building set-points are monitored via the BMS. Thermal stratification and air flow variation during changing weather conditions are shown to effect the performance of the DSF considerably and hence the energy performance of the building. The relative pressure effects due to buoyancy and wind are analysed and quantified. This research aims to developed and validate models of DSFs in the maritime climate, using multi-season data from experimental monitoring. This extensive experimental study provides data for training and validation of models.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Tese de mestrado integrado em Engenharia da Energia e do Ambiente, apresentada à Universidade de Lisboa, através da Faculdade de Ciências, 2015

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Dissertação para obtenção do grau de Mestre em Engenharia Civil na Área de Edificações

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Trabalho Final de Mestrado para obtenção do grau de Mestre em Engenharia Mecânica

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Dissertação para obtenção do grau de Mestre em Engenharia Civil na Área de Especialização em Edificações