425 resultados para endoscopic


Relevância:

20.00% 20.00%

Publicador:

Resumo:

This thesis presents an investigation on endoscopic optical coherence tomography (OCT). As a noninvasive imaging modality, OCT emerges as an increasingly important diagnostic tool for many clinical applications. Despite of many of its merits, such as high resolution and depth resolvability, a major limitation is the relatively shallow penetration depth in tissue (about 2∼3 mm). This is mainly due to tissue scattering and absorption. To overcome this limitation, people have been developing many different endoscopic OCT systems. By utilizing a minimally invasive endoscope, the OCT probing beam can be brought to the close vicinity of the tissue of interest and bypass the scattering of intervening tissues so that it can collect the reflected light signal from desired depth and provide a clear image representing the physiological structure of the region, which can not be disclosed by traditional OCT. In this thesis, three endoscope designs have been studied. While they rely on vastly different principles, they all converge to solve this long-standing problem.

A hand-held endoscope with manual scanning is first explored. When a user is holding a hand- held endoscope to examine samples, the movement of the device provides a natural scanning. We proposed and implemented an optical tracking system to estimate and record the trajectory of the device. By registering the OCT axial scan with the spatial information obtained from the tracking system, one can use this system to simply ‘paint’ a desired volume and get any arbitrary scanning pattern by manually waving the endoscope over the region of interest. The accuracy of the tracking system was measured to be about 10 microns, which is comparable to the lateral resolution of most OCT system. Targeted phantom sample and biological samples were manually scanned and the reconstructed images verified the method.

Next, we investigated a mechanical way to steer the beam in an OCT endoscope, which is termed as Paired-angle-rotation scanning (PARS). This concept was proposed by my colleague and we further developed this technology by enhancing the longevity of the device, reducing the diameter of the probe, and shrinking down the form factor of the hand-piece. Several families of probes have been designed and fabricated with various optical performances. They have been applied to different applications, including the collector channel examination for glaucoma stent implantation, and vitreous remnant detection during live animal vitrectomy.

Lastly a novel non-moving scanning method has been devised. This approach is based on the EO effect of a KTN crystal. With Ohmic contact of the electrodes, the KTN crystal can exhibit a special mode of EO effect, termed as space-charge-controlled electro-optic effect, where the carrier electron will be injected into the material via the Ohmic contact. By applying a high voltage across the material, a linear phase profile can be built under this mode, which in turn deflects the light beam passing through. We constructed a relay telescope to adapt the KTN deflector into a bench top OCT scanning system. One of major technical challenges for this system is the strong chromatic dispersion of KTN crystal within the wavelength band of OCT system. We investigated its impact on the acquired OCT images and proposed a new approach to estimate and compensate the actual dispersion. Comparing with traditional methods, the new method is more computational efficient and accurate. Some biological samples were scanned by this KTN based system. The acquired images justified the feasibility of the usage of this system into a endoscopy setting. My research above all aims to provide solutions to implement an OCT endoscope. As technology evolves from manual, to mechanical, and to electrical approaches, different solutions are presented. Since all have their own advantages and disadvantages, one has to determine the actual requirements and select the best fit for a specific application.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Whipple's disease is a chronic systemic infection produced by the actinomycete Tropheryma whipplei. Endoscopic tests are key in the diagnosis as they allow biopsy and histopathological examination for definitive diagnosis of this entity. We present a case of Whipple's disease where capsule endoscopy, uncommon for the diagnosis of this condition, was essential for it and its performance before and after antibiotic treatment allows to describe the macroscopic evolution of the findings in the small bowel. This case illustrates the usefulness of capsule endoscopy to allow complete examination of the small bowel disease in which up to 30% of patients may present with normal endoscopy.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Introduction: Flexible endoscopic treatment is one of the alternative approaches for the management of Zenker's diverticum. The present paper shows our short-term and long-term results with flexible endoscopic cricopharyngeal myotomy/septotomy. Patients and methods: A retrospective analysis of our experience in patients with Zenker's diverticulum treated using a flexible endoscope, assisted by a flexible diverticuloscope, between 2002 and 2015. Myotomy/septotomy was performed with a needle-knife papillotome under deep sedation or general anesthesia. Results: Among the 64 patients treated, two died within 10 days of surgery from causes not directly related to the procedure, and one presented with pharyngo-esophageal perforation, which recovered with conservative management at 47 days after admission. Four additional patients were lost to short-term follow-up. Among the 57 remaining patients, 52 had complete relief of dysphagia after 6 weeks. Eleven of these had recurrent symptoms on the mid and the long term. Eight were retreated with the same flexible endoscopic technique, one with a hybrid endoscopic approach, one with classical open surgery and one refused retreatment. After a mean follow-up of 2 years and a half, 33 of 37 patients reported absent or minimal dysphagia, controllable with punctual dietary restrictions. Conclusions: Flexible endoscopic treatment for Zenker's diverticulum is effective and safe. It represents an option on an equal footing to rigid endoscopy and classical open surgery and may also be used when the latter two are technically impracticable or contraindicated.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Study Design: Biomechanical testing of vertebral body screw pullout resistance with relevance to top screw pullout in endoscopic anterior scoliosis constructs. Objectives: To analyse the effect of screw positioning and angulation on pullout resistance of vertebral body screws, where the pullout takes place along a curved path as occurs in anterior scoliosis constructs. Summary of Background Data: Top screw pullout is a significant clinical problem in endoscopic anterior scoliosis surgery, with rates of up to 18% reported in the literature. Methods: A custom designed biomechanical test rig was used to perform pullout tests of Medtronic anterior vertebral screws where the pullout occurred along an arc of known radius. Using synthetic bone blocks, a range of pullout radii and screw angulations were tested, in order to determine an ‘optimal’ configuration. The optimal configuration was then compared with standard screw positioning using a series of tests on ovine vertebrae (n=29). Results: Screw angulation has a small but significant effect on pullout resistance, with maximum strength being achieved at 10 degree cephalad angulation. Combining 10 degree cephalad angulation with maximal spacing between the top two screws (maximum pullout radius) increased the pullout resistance by 88% compared to ‘standard’ screw positioning (screws inserted perpendicular to rod at mid-body height). Conclusions: The positioning of the top screw in anterior scoliosis constructs can significantly alter its pullout resistance.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Adolescent Idiopathic Scoliosis (AIS) has been associated with reduced pulmonary function believed to be due to a restriction of lung volume by the deformed thoracic cavity. A recent study by our group examined the changes in lung volume pre and post anterior thoracoscopic scoliosis correction using pulmonary function testing (1), however the anatomical changes in ribcage shape and left/right lung volume after thoracoscopic surgery which govern overall respiratory capacity are unknown. The aim of this study was to use 3D rendering from CT scan data to compare lung and ribcage anatomical changes from pre to two years post thoracoscopic anterior scoliosis correction. The study concluded that 3D volumetric reconstruction from CT scans is a powerful means of evaluating changes in pulmonary and thoracic anatomy following surgical AIS correction. Most likely, lung volume changes following thoracoscopic scoliosis correction are multifactorial and affected by changes in height (due to residual growth), ribcage shape, diaphragm positioning, Cobb angle correction in the thoracic spine. Further analysis of the 3D reconstructions will be performed to assess how each of these factors affect lung volume in this patient cohort.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Throughout history, developments in medicine have aimed to improve patient quality of life, and reduce the trauma associated with surgical treatment. Surgical access to internal organs and bodily structures has been traditionally via large incisions. Endoscopic surgery presents a technique for surgical access via small (1 Omm) incisions by utilising a scope and camera for visualisation of the operative site. Endoscopy presents enormous benefits for patients in terms of lower post operative discomfort, and reduced recovery and hospitalisation time. Since the first gall bladder extraction operation was performed in France in 1987, endoscopic surgery has been embraced by the international medical community. With the adoption of the new technique, new problems never previously encountered in open surgery, were revealed. One such problem is that the removal of large tissue specimens and organs is restricted by the small incision size. Instruments have been developed to address this problem however none of the devices provide a totally satisfactory solution. They have a number of critical weaknesses: -The size of the access incision has to be enlarged, thereby compromising the entire endoscopic approach to surgery. - The physical quality of the specimen extracted is very poor and is not suitable to conduct the necessary post operative pathological examinations. -The safety of both the patient and the physician is jeopardised. The problem of tissue and organ extraction at endoscopy is investigated and addressed. In addition to background information covering endoscopic surgery, this thesis describes the entire approach to the design problem, and the steps taken before arriving at the final solution. This thesis contributes to the body of knowledge associated with the development of endoscopic surgical instruments. A new product capable of extracting large tissue specimens and organs in endoscopy is the final outcome of the research.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The relationship between radiologic union and clinical outcome in thoracoscopic scoliosis surgery is not clear, as apparent non-union of a spinal fusion does not always correspond to a poor clinical result. The aim of this study was to evaluate CT fusion rates 24 months after thoracoscopic anterior scoliosis surgery, and to explore the relationship between fusion scores and; (i) rod diameter, (ii) graft type, (iii) fusion level, (iv) occurrence of post-operative implant failure, and (v) lateral position of the fusion mass in the intervertebral disc space. We propose that moderate fusion scores on the Sucato scale secure successful clinical outcomes in thoracoscopic scoliosis surgery.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The relationship between radiologic union and clinical outcomes in thoracoscopic scoliosis surgery is not clear, as apparent non-union of a spinal fusion does not always correspond to a poor clinical result. The aim of this study was to evaluate for the first time the interbody fusion rates using low dose CT scans at minimum 24 months after thoracoscopic scoliosis surgery, and to explore the relationship between fusion scores and; (i) rod diameter, (ii) graft type, (iii) fusion level, (iv) implant failure, and (v) lateral position in the disc space. The study found that moderate fusion scores on the Sucato scale secure successful clinical outcomes in thoracoscopic scoliosis surgery.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

"This letter aims to highlight the multisensory integration weighting mechanisms that may account for the results in studies investigating haptic feedback in laparoscopic surgery. The current lack of multisensory theoretical knowledge in laparoscopy is evident, and “a much better understanding of how multimodal displays in virtual environments influence human performance is required” ...publisher website

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Current diagnostic methods for assessing the severity of articular cartilage degenerative conditions, such as osteoarthritis, are inadequate. There is also a lack of techniques that can be used for real-time evaluation of the tissue during surgery to inform treatment decision and eliminate subjectivity. This book, derived from Dr Afara’s doctoral research, presents a scientific framework that is based on near infrared (NIR) spectroscopy for facilitating the non-destructive evaluation of articular cartilage health relative to its structural, functional, and mechanical properties. This development is a component of the ongoing research on advanced endoscopic diagnostic techniques in the Articular Cartilage Biomechanics Research Laboratory of Professor Adekunle Oloyede at Queensland University of Technology (QUT), Brisbane Australia.