253 resultados para embolization
Resumo:
Lymphangioleiomyomatosis is a rare pulmonary disease encountered almost exclusively in women of reproductive age. Pulmonary involvement is characterized by multiple thin-walled cysts in the lungs, recurrent pneumothorax, obstructive lung disorders, and progression to chronic respiratory failure over a mean period of 10 years. Certainty of diagnosis requires a lung biopsy, but international criteria have been proposed for a diagnosis without such a biopsy. International recommendations were recently issued for the diagnosis and treatment of lymphangioleiomyomatosis. Treatment is principally symptomatic and relies on the management of bronchial obstruction by bronchodilators; of hypoxemia by oxygen therapy; of pleural complications by pleurodesis, most often surgical; and of renal angiomyolipomas by percutaneous embolization in cases of hemorrhagic risk. Hormone treatment is not recommended. Hopes are high for mTor inhibitors (sirolimus and everolimus) and treatment trials are currently underway. Lung transplantation must be considered when chronic respiratory failure occurs in patients younger than 60 years.
Resumo:
OBJECTIVES: This study sought to investigate whether self-expanding stents are more effective than balloon-expandable stents for reducing stent malapposition at 3 days after implantation in patients with ST-segment elevation myocardial infarction undergoing primary percutaneous coronary intervention. BACKGROUND: Acute myocardial infarction is associated with vasoconstriction and large thrombus burden. Resolution of vasoconstriction and thrombus load during the first hours to days after primary percutaneous coronary intervention may lead to stent undersizing and malapposition, which may subsequently lead to stent thrombosis or restenosis. In addition, aggressive stent deployment may cause distal embolization. METHODS: Eighty patients with ST-segment elevation myocardial infarction undergoing primary percutaneous coronary intervention were randomized to receive a self-expanding stent (STENTYS, STENTYS SA, Paris, France) (n = 43) or a balloon-expandable stent (VISION, Abbott Vascular, Santa Clara, California; or Driver, Medtronic, Minneapolis, Minnesota) (n = 37) at 9 European centers. The primary endpoint was the proportion of stent strut malapposition at 3 days after implantation measured by optical coherence tomography. Secondary endpoints included major adverse cardiac events (cardiac death, recurrent myocardial infarction, emergent bypass surgery, or clinically driven target lesion revascularization). RESULTS: At 3 days after implantation, on a per-strut basis, a lower rate of malapposed stent struts was observed by optical coherence tomography in the self-expanding stent group than in the balloon-expandable group (0.58% vs. 5.46%, p < 0.001). On a per-patient basis, none of the patients in the self-expanding stent group versus 28% in the balloon-expandable group presented ≥5% malapposed struts (p < 0.001). At 6 months, major adverse cardiac events were 2.3% versus 0% in the self-expanding and balloon-expandable groups, respectively (p = NS). CONCLUSIONS: Strut malapposition at 3 days is significantly lower in ST-segment elevation myocardial infarction patients allocated to self-expanding stents when than in those allocated to balloon-expandable stents. The impact of this difference on clinical outcome and the risk of late stent thrombosis need to be evaluated further. (Randomized Comparison Between the STENTYS Self-expanding Coronary Stent and a Balloon-expandable Stent in Acute Myocardial Infarction [APPOSITION II]; NCT01008085).
Resumo:
Splenic arterial interventions are increasingly performed to treat various clinical conditions, including abdominal trauma, hypersplenism, splenic arterial aneurysm, portal hypertension, and splenic neoplasm. When clinically appropriate, these procedures may provide an alternative to open surgery. They may help to salvage splenic function in patients with posttraumatic injuries or hypersplenism and to improve hematologic parameters in those who otherwise would be unable to undergo high-dose chemotherapy or immunosuppressive therapy. Splenic arterial interventions also may be performed to exclude splenic artery aneurysms from the parent vessel lumen and prevent aneurysm rupture; to reduce portal pressure and prevent sequelae in patients with portal hypertension; to treat splenic artery steal syndrome and improve liver perfusion in liver transplant recipients; and to administer targeted treatment to areas of neoplastic disease in the splenic parenchyma. As the use of splenic arterial interventions increases in interventional radiology practice, clinicians must be familiar with the splenic vascular anatomy, the indications and contraindications for performing interventional procedures, the technical considerations involved, and the potential use of other interventional procedures, such as radiofrequency ablation, in combination with splenic arterial interventions. Familiarity with the complications that can result from these interventional procedures, including abscess formation and pancreatitis, also is important.
Resumo:
BACKGROUND AND PURPOSE: Endovascular treatment of wide-neck bifurcation aneurysms often results in incomplete occlusion or aneurysm recurrence. The goals of this study were to compare results of coil embolization with or without the assistance of self-expandable stents and to examine how stents may influence neointima formation. MATERIALS AND METHODS: Wide-neck bifurcation aneurysms were constructed in 24 animals and, after 4-6 weeks, were randomly allocated to 1 of 5 groups: 1) coil embolization using the assistance of 1 braided stent (n = 5); 2) coil embolization using the assistance of 2 braided stents in a Y configuration (n = 5); 3) coil embolization without stent assistance (n = 6); 4) Y-stenting alone (n = 4); and 5) untreated controls (n = 4). Angiographic results were compared at baseline and at 12 weeks, by using an ordinal scale. Neointima formation at the neck at 12 weeks was compared among groups by using a semiquantitative grading scale. Bench studies were performed to assess stent porosities. RESULTS: Initial angiographic results were improved with single stent-assisted coiling compared with simple coiling (P = .013). Angiographic results at 12 weeks were improved with any stent assistance (P = .014). Neointimal closure of the aneurysm neck was similar with or without stent assistance (P = .908), with neointima covering coil loops but rarely stent struts. Y-stent placement alone had no therapeutic effect. Bench studies showed that porosities can be decreased with stent compaction, but a relatively stable porous transition zone was a limiting factor. CONCLUSIONS: Stent-assisted coiling may improve results of embolization by allowing more complete initial coiling, but these high-porosity stents did not provide a scaffold for more complete neointimal closure of aneurysms.
Resumo:
PURPOSE: The combination of embolic beads with a multitargeted tyrosine kinase inhibitor that inhibits tumor vessel growth is suggested as an alternative and improvement to the current standard doxorubicin-eluting beads for use in transarterial chemoembolization. This study demonstrates the in vitro loading and release kinetics of sunitinib using commercially available embolization microspheres and evaluates the in vitro biologic efficacy on cell cultures and the resulting in vivo pharmacokinetics profiles in an animal model. MATERIALS AND METHODS: DC Bead microspheres, 70-150 µm and 100-300 µm (Biocompatibles Ltd., Farnham, United Kingdom), were loaded by immersion in sunitinib solution. Drug release was measured in saline in a USP-approved flow-through apparatus and quantified by spectrophotometry. Activity after release was confirmed in cell culture. For pharmacokinetics and in vivo toxicity evaluation, New Zealand white rabbits received sunitinib either by intraarterial injection of 100-300 µm sized beads or per os. Plasma and liver tissue drug concentrations were assessed by liquid chromatography-tandem mass spectroscopy. RESULTS: Sunitinib loading on beads was close to complete and homogeneous. A total release of 80% in saline was measured, with similar fast-release profiles for both sphere sizes. After embolization, drug plasma levels remained below the therapeutic threshold (< 50 ng/mL), but high concentrations at 6 hours (14.9 µg/g) and 24 hours (3.4 µg/g) were found in the liver tissue. CONCLUSIONS: DC Bead microspheres of two sizes were efficiently loaded with sunitinib and displayed a fast and almost complete release in saline. High liver drug concentrations and low systemic levels indicated the potential of sunitinib-eluting beads for use in embolization.
Resumo:
Drug-eluting microspheres are used for embolization of hypervascular tumors and allow for local controlled drug release. Although the drug release from the microspheres relies on fast ion-exchange, so far only slow-releasing in vitro dissolution methods have been correlated to in vivo data. Three in vitro release methods are assessed in this study for their potential to predict slow in vivo release of sunitinib from chemoembolization spheres to the plasma, and fast local in vivo release obtained in an earlier study in rabbits. Release in an orbital shaker was slow (t50%=4.5h, 84% release) compared to fast release in USP 4 flow-through implant cells (t50%=1h, 100% release). Sunitinib release in saline from microspheres enclosed in dialysis inserts was prolonged and incomplete (t50%=9 days, 68% release) due to low drug diffusion through the dialysis membrane. The slow-release profile fitted best to low sunitinib plasma AUC following injection of sunitinib-eluting spheres. Although limited by lack of standardization, release in the orbital shaker fitted best to local in vivo sunitinib concentrations. Drug release in USP flow-through implant cells was too fast to correlate with local concentrations, although this method is preferred to discriminate between different sphere types.
Resumo:
Five years of experience with endovascular infrarenal aneurysm repair at our institution is reviewed. Implantation of endoprostheses in 88 patients has been performed by surgeons using exclusively intravascular ultrasound (IVUS) and fluoroscopy. IVUS identified the target site of deployment in all cases. In-hospital morbidity was 22% (19/88). Two percent mortality (2/88) and 5% early conversion (4/88) as a consequence of type I endoleaks were noted only in the first 53 patients with early devices (NS). Early endoleaks were present in 36% (32/88) including twenty-two type I, five type II and five type III endoleaks. Proximal endoleaks were associated with early devices (P<0.001), and technical difficulties with deployment. Tube grafts used in the beginning, performed poorly with 54% (7/13) type I endoleaks. Endoleaks diminished to 10% (9/88) by spontaneous closure and secondary endovascular procedures that were necessary in 24% (21/88) and consisted of coil embolization/cuff extension (9), late conversion (6), and limb recanalization or femoral cross-over bypass (6). Endovascular aneurysm repair using IVUS is a valid alternative technique. Improved devices and systematic use of bifurcated endoprostheses for infrarenal aneurysms reduce the occurrence of type I endoleaks.
Resumo:
This review assesses the presentation, management, and outcome of delayed postpancreatectomy hemorrhage (PPH) and suggests a novel algorithm as possible standard of care.An electronic search of Medline and Embase databases from January 1990 to February 2010 was undertaken. A random-effect meta-analysis for success rate and mortality of laparotomy vs. interventional radiology after delayed PPH was performed.Fifteen studies comprising of 248 patients with delayed PPH were included. Its incidence was of 3.3%. A sentinel bleed heralding a delayed PPH was observed in 45% of cases. Pancreatic leaks or intraabdominal abscesses were found in 62%. Interventional radiology was attempted in 41%, and laparotomy was undertaken in 49%. On meta-analysis comparing laparotomy vs. interventional radiology, no significant difference could be found in terms of complete hemostasis (76% vs. 80%; P = 0.35). A statistically significant difference favored interventional radiology vs. laparotomy in term of mortality (22% vs. 47%; P = 0.02).Proper management of postoperative complications, such as pancreatic leak and intraabdominal abscess, minimizes the risk of delayed PPH. Sentinel bleeding needs to be thoroughly investigated. If a pseudoaneurysm is detected, it has to be treated by interventional angiography, in order to prevent a further delayed PPH. Early angiography and embolization or stenting is safe and should be the procedure of choice. Surgery remains a therapeutic option if no interventional radiology is available, or patients cannot be resuscitated for an interventional treatment.
Resumo:
PURPOSE: Colonoscopy is reported to be a safe procedure that is routinely performed for the diagnosis and treatment of colorectal diseases. Splenic rupture is considered to be a rare complication with high mortality and morbidity that requires immediate diagnosis and management. Nonoperative management (NOM), surgical treatment (ST), and, more recently, proximal splenic artery embolization (PSAE) have been proposed as treatment options. The goal of this study was to assess whether PSAE is safe even in high-grade ruptures. METHODS: We report two rare cases of post colonoscopy splenic rupture. A systematic review of the literature from 2002 to 2010 (first reported case of PSAE) was performed and the three types of treatment compared. RESULTS: All patients reviewed (77 of 77) presented with intraperitoneal hemorrhage due to isolated splenic trauma. Splenic rupture was high-grade in most patients when grading was possible. Six of 77 patients (7.8Â %) were treated with PSAE, including the 2 cases reported herein. Fifty-seven patients (74Â %) underwent ST. NOM was attempted first in 25 patients with a high failure rate (11 of 25 [44Â %]) and requiring a salvage procedure, such as PSAE or ST. Previous surgery (31 of 59 patients), adhesions (10 of 13), diagnostic colonoscopies (49 of 71), previous biopsies or polypectomies (31 of 57) and female sex (56 of 77) were identified as risk factors. In contrast, splenomegaly (0 of 77 patients), medications that increase the risk of bleeding (13 of 30) and difficult colonoscopies (16 of 51) were not identified as risk factors. PSAE was safe and effective even in elderly patients with comorbidities and those taking medications that increase the risk of bleeding, and the length of the hospital stay was similar to that after ST. CONCLUSION: We propose a treatment algorithm based on clinical and radiological criteria. Because of the high failure rate after NOM, PSAE should be the treatment of choice to manage grade I through IV splenic ruptures after colonoscopy in hemodynamically stabilized patients.
Resumo:
Interventional paediatric and congenital cardiology is expanding at a rapid pace. Validated techniques (such as aortic or pulmonary valve dilatations and occlusion of persistent ductus arteriosus and atrial septal defects) are improving thanks to the use of smaller introducers and sheaths, low-profile balloons and novel devices. Moreover, catheter-based interventions have emerged as an attractive alternative to surgery in other fields: pulmonary valve replacement, balloon and stent implantation for native and recurrent coarctation, and percutaneous closure of ventricular septal defects. On the other hand, percutaneous interventions in the paediatric population may be limited by patient size or the anatomy of the defect. Hybrid approaches involving both cardiac interventionists and surgeons are being developed to overcome these limitations. Based on a better understanding of cardiac development, fetal cardiac interventions are being attempted in order to alter the history of severe obstructive lesions. Finally, some interventional procedures still carry a low success rate-for example, pulmonary vein stenosis, even with the use of conventional stents. Biodegradable stents and devices are being developed and may find an application in this setting as well as in others. The purpose of this review is to highlight the advances in paediatric interventional cardiology since the beginning of the third millennium.
Resumo:
Background: Chemoembolization is used to treat liver malignancies. However recurrence occurs frequently, possibly because of neoangiogenesis triggered by ischemia caused by the embolic agent. In this context, the combination of an embolic agent with an anti-angiogenic drug seems appealing. This study characterizes the in vitro loading and release profile of sunitinib eluting beads of different sizes and their pharmacokinetic profile in a rabbit model. Methods: 70-150 μm and 100-300 μm drug eluting beads (DC Bead, Biocompatibles UK) were loaded by incubation in a sunitinib hydrochloride solution. Drug was quantified by spectrophotometry at 430 nm. Drug release was measured over one-week periods and normalized using an internal standard in 30% ethanol in NaCl 0.9%. New-Zealand white rabbits were used. Eight animals received 0.2 ml of 100-300 μm DC Bead loaded with 6 mg of sunitinib in the hepatic artery (group 1) and 4 animals received 6 mg of sunitinib p.o. (group 2). Half of the animals were sacrificed after 6 hours and half after24 hours. Liver enzymes were measured at 0, 6 and 24 hours in both groups. Plasmatic sunitinib concentration was determined by tandem mass spectroscopy (LC MS/MS) at 0, 1, 2, 3, 4, 5, 6 and 24 hours. At sacrifice, the livers were harvested and sunitinib concentration in liver tissue was assessed by LC MS/MS. Results: High drug loading was obtained for both microsphere bead sizes. Particle shrinking was observed with adsorption of sunitinib. Almost complete release of sunitinib was detected under physiological conditions, with very similar release for 70-150 μm and 100-300 μm (t50%=1.2 h) DC Bead. Conclusions: Sunitinib eluting beads are well tolerated by rabbits when administered in the hepatic artery. No unexpected toxicity was observed. Very high drug concentration can be obtained at the site of embolization with minimal systemic passage.
Resumo:
Objective:This review assesses the presentation,management, and outcome of delayed postpancreatectomy hemorrhage (PPH) and suggests a novel algorithm as possible standard of care.Methods: An electronic search of Medline and Embase databases from January 1990 to February 2010 was undertaken. A random-effect meta-analysis for success rate and mortality of laparotomy vs. interventional radiology after delayed PPH was performed.Results: Fifteen studies including 248 patients with delayed PPH were included. Its incidence was 3?3%. A sentinel bleed heralding a delayed PPH was observed in 45% of cases. Pancreatic leaks or intraabdominal abscesses were found in 62%. Interventional radiology was attempted in 41%, and laparotomy was undertaken in 49%. On meta-analysis comparing laparotomy vs. interventional radiology, no significant difference could be observed in term of complete hemostasis (76% vs. 80%; P = 0?35). A statistically significant difference favored interventional radiology vs. laparotomy in term of mortality (22% vs. 47%; P = 0?02).Conclusion: Proper and early management of postoperative complications, such as pancreatic leak and intraabdominal abscess, minimizes the risk of delayed PPH. Sentinel bleeding needs to be thoroughly investigated. If a pseudoaneurysm is detected, it has to be treated by interventional angiography, in order to prevent a further delayed PPH. Early angiography and embolization or stenting is safe and should be the procedure of choice. Surgery remains a therapeutic option if no interventional radiology is available, or patients cannot be resuscitated for an interventional treatment.
Resumo:
Acute pancreatitis can complicate non-selective transcatheter arterial embolization of hepatocellular carcinoma with an incidence ranging from 1,7% (acute clinical pancreatitis) to 40% (biological pancreatitis). This complication is thought to be related to embolization of extrahepatic arterial collaterals.We report herein a case of acute clinical pancreatitis developing within 24 hours after a second course of selective transcatheter arterial chemo-embolization into the proper hepatic artery. Neither anatomical arterial variation nor particular risk factor for acute pancreatitis could be identified. This complication is unusual after selective arterial embolization. Because it may clinically mimick a postembolization syndrome, dosage of serum pancreatic enzymes should be performed systematically in case of abdominal pain following chemoembolization.
Resumo:
OBJECTIVES: This study aimed to characterize myocardial infarction after percutaneous coronary intervention (PCI) based on cardiac marker elevation as recommended by the new universal definition and on the detection of late gadolinium enhancement (LGE) by cardiovascular magnetic resonance (CMR). It is also assessed whether baseline inflammatory biomarkers are higher in patients developing myocardial injury. BACKGROUND: Cardiovascular magnetic resonance accurately assesses infarct size. Baseline C-reactive protein (CRP) and neopterin predict prognosis after stent implantation. METHODS: Consecutive patients with baseline troponin (Tn) I within normal limits and no LGE in the target vessel underwent baseline and post-PCI CMR. The Tn-I was measured until 24 h after PCI. Serum high-sensitivity CRP and neopterin were assessed before coronary angiography. RESULTS: Of 45 patients, 64 (53 to 72) years of age, 33% developed LGE with infarct size of 0.83 g (interquartile range: 0.32 to 1.30 g). A Tn-I elevation >99% upper reference limit (i.e., myocardial necrosis) (median Tn-I: 0.51 μg/l, interquartile range: 0.16 to 1.23) and Tn-I > 3× upper reference limit (i.e., type 4a myocardial infarction [MI]) occurred in 58% and 47% patients, respectively. LGE was undetectable in 42% and 43% of patients with periprocedural myocardial necrosis and type 4a MI, respectively. Agreement between LGE and type 4a MI was moderate (kappa = 0.45). The levels of CRP or neopterin did not significantly differ between patients with or without myocardial injury, detected by CMR or according to the new definition (p = NS). CONCLUSIONS: This study reports the lack of substantial agreement between the new universal definition and CMR for the diagnosis of small-size periprocedural myocardial damage after complex PCI. Baseline levels of CRP or neopterin were not predictive for the development of periprocedural myocardial damage.