1000 resultados para electronic apex locator


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background Historically, the paper hand-held record (PHR) has been used for sharing information between hospital clinicians, general practitioners and pregnant women in a maternity shared-care environment. Recently in alignment with a National e-health agenda, an electronic health record (EHR) was introduced at an Australian tertiary maternity service to replace the PHR for collection and transfer of data. The aim of this study was to examine and compare the completeness of clinical data collected in a PHR and an EHR. Methods We undertook a comparative cohort design study to determine differences in completeness between data collected from maternity records in two phases. Phase 1 data were collected from the PHR and Phase 2 data from the EHR. Records were compared for completeness of best practice variables collected The primary outcome was the presence of best practice variables and the secondary outcomes were the differences in individual variables between the records. Results Ninety-four percent of paper medical charts were available in Phase 1 and 100% of records from an obstetric database in Phase 2. No PHR or EHR had a complete dataset of best practice variables. The variables with significant improvement in completeness of data documented in the EHR, compared with the PHR, were urine culture, glucose tolerance test, nuchal screening, morphology scans, folic acid advice, tobacco smoking, illicit drug assessment and domestic violence assessment (p = 0.001). Additionally the documentation of immunisations (pertussis, hepatitis B, varicella, fluvax) were markedly improved in the EHR (p = 0.001). The variables of blood pressure, proteinuria, blood group, antibody, rubella and syphilis status, showed no significant differences in completeness of recording. Conclusion This is the first paper to report on the comparison of clinical data collected on a PHR and EHR in a maternity shared-care setting. The use of an EHR demonstrated significant improvements to the collection of best practice variables. Additionally, the data in an EHR were more available to relevant clinical staff with the appropriate log-in and more easily retrieved than from the PHR. This study contributes to an under-researched area of determining data quality collected in patient records.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Layered materials exhibit intriguing electronic characteristics and the search for new types of two-dimensional (2D) structures is of importance for future device fabrication. Using state-of-art first principle calculations, we identify and characterize the structural and electronic properties of two 2D layered arsenic materials, namely, arsenic and its alloy AsSb. The stable 2D structural configuration of arsenic is confirmed to be the low-buckled two-dimensional hexagonal structure by phonon and binding energy calculations. The monolayer exhibits indirect semiconducting properties with gap around 1.5 eV (corrected to 2.2 eV by hybrid function), which can be modulated into a direct semiconductor within a small amount of tensile strain. These semiconducting properties are preserved when cutting into 1D nanoribbons, but the band gap is edge dependent. It is interesting to find that an indirect to direct gap transition can be achieved under strain modulation of the armchair ribbon. Essentially the same phenomena can be found in layered AsSb, except a weak Rashba induced band splitting is present in AsSb due to the nonsymmetric structure and spin orbit coupling. When an additional layer is added on the top, a semiconductor–metal transition will occur. The findings here broaden the family of 2D materials beyond graphene and transition metal dichalcogenides and provide useful information for experimental fabrication of new layered materials with possible application in optoelectronics.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background The use of Electronic Medical Record (EMR) systems is increasing internationally, though developing countries, such as Saudi Arabia, have tended to lag behind in the adoption and implementation of EMR systems due to several barriers. The literature shows that the main barriers to EMR in Saudi Arabia are lack of knowledge or experience using EMR systems and staff resistance to using the implemented EMR system. Methods A quantitative methodology was used to examine health personnel knowledge and acceptance of and preference for EMR systems in seven Saudi public hospitals in Jeddah, Makkah and Taif cities. Results Both English literacy and education levels were significantly correlated with computer literacy and EMR literacy. Participants whose first language was not Arabic were more likely to prefer using an EMR system compared to those whose first language was Arabic. Conclusion This study suggests that as computer literacy levels increase, so too do staff preferences for using EMR systems. Thus, it would be beneficial for hospitals to assess English language proficiency and computer literacy levels of staff prior to implementing an EMR system. It is recommended that hospitals need to offer training and targeted educational programs to the potential users of the EMR system. This would help to increase English language proficiency and computer literacy levels of staff as well as staff acceptance of the system.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper describes the use of exploratory focus groups to inform the development of a survey instrument in a sequential phase mixed methods study investigating differences in secondary students’ career choice capability. Five focus groups were conducted with 23 year 10 students in the state of New South Wales (NSW), Australia. Analysis of the focus group data informed the design of the instrument for the second phase of the research project: a large-scale cross-sectional survey. In this paper, we discuss the benefits of using sequential phase mixed method approaches when inquiring into complex phenomena such as human capability.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The main aim of the present study was to estimate size segregated doses from e-cigarette aerosols as a function of the airway generation number in lung lobes.. After a 2-second puff, 7.7×1010 particles (DTot) with a surface area of 3.6×103 mm2 (STot), and 3.3×1010 particles with a surface area of 4.2×103 mm2 were deposited in the respiratory system for the electronic and conventional cigarettes, respectively. Alveolar and tracheobronchial deposited doses were compared to the ones received by non-smoking individuals in Western countries, showing a similar order of magnitude. Total regional doses (DR), in head and lobar tracheobronchial and alveolar regions, ranged from 2.7×109 to 1.3×1010 particles and 1.1×109 to 5.3×1010 particles, for the electronic and conventional cigarettes, respectively. DR in the right-upper lung lobe was about twice that found in left-upper lobe and 20% greater in right-lower lobe than the left-lower lobe.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Anthony Dunne’s Hertzian Tales is an exploration of the aesthetic and conceptual aspects of industrial design and its potential to bring about social change for the users of electronic objects. It is a provoking and – to first-time readers – positively alarming social commentary on the interrelationship between electronic product design and culture, and the powerful but largely under-explored potential of electronic innovation to trigger social awareness. Hertzian Tales proposes an innovative approach to critical design and therefore serves as a reflection on and a critique of the commercial design practices at large. In this second edition, Dunne reiterates the original rationale for his project: a concern that the majority of industrial designers have unwittingly joined a treadmill culture of post-industrial mass-production – turning out electronic goods that have long simply met the brief of an optimally functioning and eagerly consumable technology.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Proposed in this paper is a low-cost, half-duplex optical communication bus for control signal isolation in modular or multilevel power electronic converters. The concept is inspired by the Local Interconnect Network (LIN) serial network protocol as used in the automotive industry. The proposed communications bus utilises readily available optical transceivers and is suitable for use with low-cost microcontrollers for distributed control of multilevel converters. As a signal isolation concept, the proposed optical bus enables very high cell count modular multilevel cascaded converters (MMCCs) for high-bandwidth, high-voltage and high-power applications. Prototype hardware is developed and the optical bus concept is validated experimentally in a 33-level MMCC converter operating at 120 Vrms and 60 Hz.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Density functional theory (DFT) calculations were performed to study the structural, mechanical, electrical, optical properties, and strain effects in single-layer sodium phosphidostannate(II) (NaSnP). We find the exfoliation of single-layer NaSnP from bulk form is highly feasible because the cleavage energy is comparable to graphite and MoS2. In addition, the breaking strain of the NaSnP monolayer is comparable to other widely studied 2D materials, indicating excellent mechanical flexibility of 2D NaSnP. Using the hybrid functional method, the calculated band gap of single-layer NaSnP is close to the ideal band gap of solar cell materials (1.5 eV), demonstrating great potential in future photovoltaic application. Furthermore, strain effect study shows that a moderate compression (2%) can trigger indirect-to-direct gap transition, which would enhance the ability of light absorption for the NaSnP monolayer. With sufficient compression (8%), the single-layer NaSnP can be tuned from semiconductor to metal, suggesting great applications in nanoelectronic devices based on strain engineering techniques.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose This paper aims to understand how experiential value can generate awareness, image, perceived quality and loyalty to the moderate drinking brand. Electronic games are increasingly used by social marketers in an attempt to support target audiences uptake of social behaviours. However, little is known of the value this creates for target audiences and its impact on the uptake of a social behaviour brand. Design/methodology/approach A survey of male adolescents (n = 137) was conducted to test proposed relationships between experiential value and consumer-based brand equity dimensions. The research tested the game “Don’t Turn a Night Out into a Nightmare” that was developed by the Australian Federal Government as part of a social marketing campaign. Data were analysed using linear regression and MANCOVA. Findings The findings indicate that there are significant relationships between consumer-based brand equity dimensions for the social behaviour brand of moderate drinking, indicating relevance of a commercial marketing theory for social marketing. Furthermore, findings show that different combinations of experiential value dimensions have an impact on different components of consumer-based brand equity. These findings indicate that when social marketers are developing electronic games, they must create different combinations of value in game play to achieve awareness, positive image, high perceived quality and, ultimately, loyalty to a behaviour. Practical implications Social marketers seeking to use electronic games to influence the uptake of behaviour brands such as moderate drinking must provide a more complete value package. Originality/value This paper is the first to examine how experiential value can influence the creation of brand equity for a social behaviour brand.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The antenatal paper hand-held record (PHR) has been used extensively in general practice (GP) shared-care management of pregnant women, but recently the antenatal electronic health record (EHR) was introduced. This study aimed to examine the experiences of women and health care providers who use the PHR and the EHR, and find out the relative role of these records in the integration of care. Purposive homogenous samples of women and health care providers were interviewed as users of the PHR in phase 1 and the EHR in phase 2 of the study. Qualitative data were collected via interview with women and GPs and focus groups held with hospital health care providers. Interviews were coded manually and analysed using qualitative content analysis. Fifteen women participated in phase 1 and 12 in phase 2. Seventeen GPs participated in phase 1 and 15 in phase 2. Five focus groups with hospital health care providers were conducted in each phase. Results were categorised into four themes: 1. Record purpose; 2. Perception of the record; 3. Content of the record, and; 4. Sharing information in the record. Both women and health care providers were familiar with the PHR, but identified that some information was missing or not utilised well, and reported underuse of the EHR. The study identified continued widespread use of the PHR and several issues concerning the use of the EHR. An improvement in the strategic implementation of the EHR is suggested as a mechanism to facilitate its wider adoption.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Graphitic like layered materials exhibit intriguing electronic structures and thus the search for new types of two-dimensional (2D) monolayer materials is of great interest for developing novel nano-devices. By using density functional theory (DFT) method, here we for the first time investigate the structure, stability, electronic and optical properties of monolayer lead iodide (PbI2). The stability of PbI2 monolayer is first confirmed by phonon dispersion calculation. Compared to the calculation using generalized gradient approximation, screened hybrid functional and spin–orbit coupling effects can not only predicts an accurate bandgap (2.63 eV), but also the correct position of valence and conduction band edges. The biaxial strain can tune its bandgap size in a wide range from 1 eV to 3 eV, which can be understood by the strain induced uniformly change of electric field between Pb and I atomic layer. The calculated imaginary part of the dielectric function of 2D graphene/PbI2 van der Waals type hetero-structure shows significant red shift of absorption edge compared to that of a pure monolayer PbI2. Our findings highlight a new interesting 2D material with potential applications in nanoelectronics and optoelectronics.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The paper hand-held record (PHR) has been used extensively in general practice (GP) shared care management of pregnant women, and recently, the first Mater Shared Electronic Health Record (MSEHR) was introduced. The aim of this qualitative study was to examine women’s experiences using the records and the contribution of the records to integrate care. At the 36-week antenatal visit in a maternity tertiary centre clinic, women were identified as a user of either the PHR or the MSEHR and organised into Phase 1 and Phase 2 studies respectively. Fifteen women were interviewed in Phase 1 and 12 women in Phase 2. Semi-structured interviews were used for data collection, and analysed using qualitative content analysis. Four main themes were identified: (1) purpose of the record; (2) perceptions of the record; (3) content of the record, and; (4) sharing the record. Findings indicate that the PHR is a well-liked maternity tool. The findings also indicate there is under-usage of the MSEHR due to health-care providers failing to follow up and discuss the option of using the electronic health record option or if a woman has completed the log-in process. This paper adds to an already favourable body of knowledge about the use of the PHR. It is recommended that continued implementation of the MSEHR be undertaken to facilitate its use.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

During their entire lives, people are exposed to the pollutants present in indoor air. Recently, Electronic Nicotine Delivery Systems, mainly known as electronic cigarettes, have been widely commercialized: they deliver particles into the lungs of the users but a “second-hand smoke” has yet to be associated to this indoor source. On the other hand, the naturally-occurring radioactive gas, i.e. radon, represents a significant risk for lung cancer, and the cumulative action of these two agents could be worse than the agents separately would. In order to deepen the interaction between radon progeny and second-hand aerosol from different types of cigarettes, a designed experimental study was carried out by generating aerosol from e-cigarette vaping as well as from second-hand traditional smoke inside a walk-in radon chamber at the National Institute of Ionizing Radiation Metrology (INMRI) of Italy. In this chamber, the radon present in air comes naturally from the floor and ambient conditions are controlled. To characterize the sidestream smoke emitted by cigarettes, condensation particle counters and scanning mobility particle sizer were used. Radon concentration in the air was measured through an Alphaguard ionization chamber, whereas the measurement of radon decay product in the air was performed with the Tracelab BWLM Plus-2S Radon daughter Monitor. It was found an increase of the Potential Alpha-Energy Concentration (PAEC) due to the radon decay products attached to aerosol for higher particle number concentrations. This varied from 7.47 ± 0.34 MeV L−1 to 12.6 ± 0.26 MeV L−1 (69%) for the e-cigarette. In the case of traditional cigarette and at the same radon concentration, the increase was from 14.1 ± 0.43 MeV L−1 to 18.6 ± 0.19 MeV L−1 (31%). The equilibrium factor increases, varying from 23.4% ± 1.11% to 29.5% ± 0.26% and from 30.9% ± 1.0% to 38.1 ± 0.88 for the e-cigarette and traditional cigarette, respectively. These growths still continue for long time after the combustion, by increasing the exposure risk.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The objective of this study was to compare the short-term respiratory effects due to the inhalation of electronic and conventional tobacco cigarette-generated mainstream aerosols through the measurement of the exhaled nitric oxide (eNO). To this purpose, twenty-five smokers were asked to smoke a conventional cigarette and to vape an electronic cigarette (with and without nicotine), and an electronic cigarette without liquid (control session). Electronic and tobacco cigarette mainstream aerosols were characterized in terms of total particle number concentrations and size distributions. On the basis of the measured total particle number concentrations and size distributions, the average particle doses deposited in alveolar and tracheobronchial regions of the lungs for a single 2-s puff were also estimated considering a subject performing resting (sitting) activity. Total particle number concentrations in the mainstream resulted equal to 3.5 ± 0.4 × 109, 5.1 ± 0.1 × 109, and 3.1 ± 0.6 × 109 part. cm− 3 for electronic cigarettes without nicotine, with nicotine, and for conventional cigarettes, respectively. The corresponding alveolar doses for a resting subject were estimated equal to 3.8 × 1010, 5.2 × 1010 and 2.3 × 1010 particles. The mean eNO variations measured after each smoking/vaping session were equal to 3.2 ppb, 2.7 ppb and 2.8 ppb for electronic cigarettes without nicotine, with nicotine, and for conventional cigarettes, respectively; whereas, negligible eNO changes were measured in the control session. Statistical tests performed on eNO data showed statistically significant differences between smoking/vaping sessions and the control session, thus confirming a similar effect on human airways whatever the cigarette smoked/vaped, the nicotine content, and the particle dose received.