964 resultados para denture, complete
Resumo:
Objective Adapt the 6 minutes walking test (6MWT) to artificial gait in complete spinal cord injured (SCI) patients aided by neuromuscular electrical stimulation. Method Nine male individuals with paraplegia (AIS A) participated in this study. Lesion levels varied between T4 and T12 and time post injured from 4 to 13 years. Patients performed 6MWT 1 and 6MWT 2. They used neuromuscular electrical stimulation, and were aided by a walker. The differences between two 6MWT were assessed by using a paired t test. Multiple r-squared was also calculated. Results The 6MWT 1 and 6MWT 2 were not statistically different for heart rate, distance, mean speed and blood pressure. Multiple r-squared (r2 = 0.96) explained 96% of the variation in the distance walked. Conclusion The use of 6MWT in artificial gait towards assessing exercise walking capacity is reproducible and easy to apply. It can be used to assess SCI artificial gait clinical performance.
Resumo:
In 2004, Costa-Santos and cols. reported 24 patients from 19 Brazilian families with 17α-hydroxylase deficiency and showed that p.W406R and p.R362C corresponded to 50% and 32% of CYP17A1 mutant alleles, respectively. The present report describes clinical and molecular data of six patients from three inbred Brazilian families with 17α-hydroxlyse deficiency. All patients had hypogonadism, amenorrhea and hypertension at diagnosis. Two sisters were found to be 46,XY with both gonads palpable in the inguinal region. All patients presented hypergonadotrophic hypogonadism, with high levels of ACTH (> 104 ng/mL), suppressed plasmatic renin activity, low levels of potassium (< 2.8 mEq/L) and elevated progesterone levels (> 4.4 ng/mL). Three of them, including two sisters, were homozygous for p.W406R mutation and the other three (two sisters and one cousin) were homozygous for p.R362C. The finding of p.W406R and p.R362C in the CYP17A1 gene here reported in additional families, confirms them as the most frequent mutations causing complete combined 17α-hydroxylase/17,20-lyase deficiency in Brazilian patients.
Resumo:
OBJECTIVE: This study aimed to asses oral health conditions in a population aged 60 years and over living in Botucatu, Southeastern Brazil. A cross-sectional population-based study was carried out using a random sample (N=372) of the urban population aged 60 years and over from the city of Botucatu, in 2005. World Health Organization criteria and codes for oral health epidemiological surveys were used. Re-examination was carried out in 10% of individuals aiming to evaluate intra-examiner agreement. Statistical analysis was performed by one-way ANOVA or Kruskal-Wallis ANOVA, as applicable. Also, the t-test was used in the absence of homoscedasticity. Fisher's exact test was used for situations where the categories with less than five units were observed. Adjusted residuals and multiple-comparison analysis were conducted to identify associations between variable categories and subgroups. The intra-examiner agreement was 98% and Kappa statistics result was 0.95. Loss component represented 90.68% of DMF-T index, which was 29.85. The prevalence of edentulism was 63.17%. Upper and lower dentures were found in 80% and 58% respectively, with complete denture as the most commonly used. In those studied, 15% required upper and 38% lower dentures. There was more need for complete denture in both jaws. Approximately 20% had soft tissue alterations. For periodontal conditions, most sextants were excluded (81.81%). Periodontal pockets (4 - 5 mm) were seen in 11.29% of the examined individuals. The oral health status of the elderly population in Botucatu is poor, as well as in other Brazilian cities. The results of this study may help planning collective health actions, giving an accurate description of the oral problems among the elderly.
Resumo:
The wear resistance of denture teeth is important to the longevity of removable prostheses of edentulous patients. The ability of denture teeth to maintain a stable occlusal relationship over time may be influenced by this property. The purpose of this in vitro study was to evaluate the wear resistance of polymethyl methacrylate (PMMA) denture teeth based on their chemical composition when opposed by a ceramic antagonist. The maxillary canines (n=10) of 3 PMMA denture teeth (Trubyte Biotone, cross-linked PMMA; Trilux, highly cross-linked IPN (interpenetrating polymer network)-PMMA; and Vivodent, highly cross-linked PMMA) were secured in an in vitro 2-body wear-testing apparatus that produced sliding contact of the specimens (4.5 cycles/s, sliding distance of 20 mm, under 37°C running water) against glazed or airborne particle abraded ceramic. Wear resistance was measured as height loss (mm) under 300 g (sliding force) after 100,000 cycles, using a digital measuring microscope. Mean values were analyzed by 2-way ANOVA and Tukey's test (a=0.05). The wear of Trubyte Biotone (0.93 ± 0.14 mm) was significantly higher than that of both other types of teeth tested against abraded ceramic (p<0.05). The Vivodent tooth (0.64 ± 0.17 mm) exhibited the best wear resistance among the denture teeth tested against airborne particle abraded ceramic. There were no statistically significant differences (p>0.05) in wear among the 3 denture teeth evaluated against glazed ceramic. Trilux and Vivodent teeth tested against either glazed or airborne particle abraded ceramic did not differ significantly from each other (p<0.05). All teeth showed significantly more wear against airborne particle abraded ceramic than against glazed ceramic (p<0.05). In conclusion, the three types of PMMA denture teeth presented significantly different wear resistance against the abraded ceramic. The high-strength PMMA denture teeth were more wear-resistant than the conventional PMMA denture tooth.
Correlation between margin fit and microleakage in complete crowns cemented with three luting agents
Resumo:
Microleakage can be related to margin misfit. Also, traditional microleakage techniques are time-consuming. This study evaluated the existence of correlation between in vitro margin fit and a new microleakage technique for complete crowns cemented with 3 different luting agents. Thirty human premolars were prepared for full-coverage crowns with a convergence angle of 6 degrees, chamfer margin of 1.2 mm circumferentially, and occlusal reduction of 1.5 mm. Ni-Cr cast crowns were cemented with either zinc phosphate (ZP) (S.S. White), resin-modified glass-ionomer (RMGI) (Rely X Luting Cement) or a resin-based luting agent (RC) (Enforce). Margin fit (seating discrepancy and margin gap) was evaluated according to criteria in the literature under microscope with 0.001 mm accuracy. After thermal cycling, crowns were longitudinally sectioned and microleakage scores at tooth-cement interface were obtained and recorded at ×100 magnification. Margin fit parameters were compared with the one-way ANOVA test and microleakage scores with Kruskal-Wallis and Dunn's tests (alpha=0.05). Correlation between margin fit and microleakage was analyzed with the Spearman's test (alpha=0.05). Seating discrepancy and marginal gap values ranged from 81.82 µm to 137.22 µm (p=0.117), and from 75.42 µm to 78.49 µm (p=0.940), respectively. Marginal microleakage scores were ZP=3.02, RMGI=0.35 and RC=0.12 (p<0.001), with no differences between RMGI and RC scores. The correlation coefficient values ranged from -0.27 to 0.30 (p>0.05). Conclusion: Margin fit parameters and microleakage showed no strong correlations; cast crowns cemented with RMGI and RC had lower microleakage scores than ZP cement.
Resumo:
Fluorinated denture base acrylic resins can present more stable physical properties when compared with conventional polymers. This study evaluated the incorporation of a fluoroalkyl methacrylate (FMA) mixture in a denture base material and its effect on roughness and flexural strength. A swelling behavior assessment of acrylic resin specimens (n=3, per substance) after 12 h of FMA or methyl methacrylate (MMA) immersion was conducted to determine the solvent properties. Rectangular specimens (n=30) were allocated to three groups, according to the concentration of FMA substituted into the monomer component of a heat-polymerized acrylic resin (Lucitone 550), as follows: 0% (control), 10% and 20% (v/v). Acrylic resin mixed with concentrations of 25% or more did not reach the dough stage and was not viable. The surface roughness and flexural strength of the specimens were tested. Variables were analyzed by ANOVA and Tukey's test (a=0.05). Immersion in FMA produced negligible swelling, and MMA produced obvious swelling and dissolution of the specimens. Surface roughness at concentrations of 0%, 10% and 20% were: 0.25 ± 0.04, 0.24 ± 0.04, 0.22 ± 0.03 mm (F=1.78; p=0.189, not significant). Significant differences were found for flexural strength (F=15.92; p<0.001) and modulus of elasticity (F=7.67; p=0.002), with the following results: 96 ± 6, 82 ± 5, 84 ± 6 MPa, and 2,717 ± 79, 2,558 ± 128, 2574 ± 87 MPa, respectively. The solvent properties of FMA against acrylic resin are weak, which would explain why concentrations over 20% were not viable. Surface changes were not detected after the incorporation of FMA in the denture base acrylic resin tested. The addition of FMA into denture base resin may lower the flexural strength and modulus of elasticity, regardless of the tested concentration.
Resumo:
OBJECTIVE: Removable partial dentures (RPD) require different hygiene care, and association of brushing and chemical cleansing is the most recommended to control biofilm formation. However, the effect of cleansers has not been evaluated in RPD metallic components. The aim of this study was to evaluate in vitro the effect of different denture cleansers on the weight and ion release of RPD. MATERIAL AND METHODS: Five specimens (12x3 mm metallic disc positioned in a 38x18x4 mm mould filled with resin), 7 cleanser agents [Periogard (PE), Cepacol (CE), Corega Tabs (CT), Medical Interporous (MI), Polident (PO), 0.05% sodium hypochlorite (NaOCl), and distilled water (DW) (control)] and 2 cobalt-chromium alloys [DeguDent (DD), and VeraPDI (VPDI)] were used for each experimental situation. One hundred and eighty immersions were performed and the weight was analyzed with a high precision analytic balance. Data were recorded before and after the immersions. The ion release was analyzed using mass spectrometry with inductively coupled plasma. Data were analyzed by two-way ANOVA and Tukey HSD post hoc test at 5% significance level. RESULTS: Statistical analysis showed that CT and MI had higher values of weight loss with higher change in VPDI alloy compared to DD. The solutions that caused more ion release were NaOCl and MI. CONCLUSIONS: It may be concluded that 0.05% NaOCl and Medical Interporous tablets are not suitable as auxiliary chemical solutions for RPD care.
Resumo:
Removable partial dentures (RPD) demand specific hygienic cleaning and the combination of brushing with immersion in chemical solutions has been the most recommended method for control of biofilm. However, the effect of the cleansers on metallic components has not been widely investigated. This study evaluated the effect of different cleansers on the surface of RPD. Five disc specimens (12 mm x 3 mm metallic disc centered in a 38 x 18 x 4 mm mould filled with resin) were obtained for each experimental situation: 6 solutions [Periogard (PE), Cepacol (CE), Corega Tabs (CT), Medical Interporous (MI), Polident (PO), 0.05% sodium hypochlorite (NaOCl), and distilled water (DW) control] and 2 Co-Cr alloys [DeguDent (DD) and VeraPDI (VPDI)] were used for each experimental situation. A 180-day immersion was simulated and the measurements of roughness (Ra, µm) of metal and resin were analyzed using 2-way ANOVA and Tukey’s test. The surface changes and tarnishes were examined with a scanning electronic microscopy (SEM). In addition, energy dispersive x-ray spectrometry (EDS) analysis was carried out at representative areas. Visually, NaOCl and MI specimens presented surface tarnishes. The roughness of materials was not affected by the solutions (p>0.05). SEM images showed that NaOCl and MI provided surface changes. EDS analysis revealed the presence of oxygen for specimens in contact with both MI and NaOCl solutions, which might suggest that the two solutions promoted the oxidation of the surfaces, thus leading to spot corrosion. Within the limitations of this study, it may be concluded that the NaOCl and MI may not be suitable for cleaning of RPD.
Resumo:
This article reports the case of a 55-year-old female patient who presented with unsatisfactory temporary crowns in the right mandibular premolars and molars, and a premolar-to-molar fixed partial denture in the left side. The clinical and radiographic examinations revealed a fracture of the left first premolar that was a retainer of the fixed partial denture and required extraction. Initially, the acrylic resin crowns were replaced by new ones, and a provisional RPD was made using acrylic resin and orthodontic wire clasps to resolve the problem arising from the loss of the fixed partial denture. Considering the patient's high esthetic demands, the treatment options for the definitive prosthetic treatment were discussed with her and rehabilitation with implant-supported dentures was proposed because the clinical conditions of the residual alveolar ridge were suitable for implant installation, and the patient's general health was excellent. However, the patient did not agree because she knew of a failed case of implant-retained denture in a diabetic individual and was concerned. The patient was fully informed that implant installation was the best indication for her case, but the arguments were not sufficient to change her decision. The treatment possibilities were presented and the patient opted for a clasp-retained removable partial denture (RPD) associated with the placement of crowns in the pillar teeth. The temporary RPD was replaced by the definitive RPD constructed subsequently. Although RPD was not the first choice, satisfactory esthetic and functional outcomes were achieved, overcaming the patient's expectations. This case report illustrates that the dentist must be prepared to deal with situations where, for reasons that cannot be managed, the patient does not accept the treatment considered as the most indicated for his/her case. Alternatives must be proposed and the functional and esthetic requirements must be fulfilled in the best possible manner.
Resumo:
OBJECTIVES: To evaluate the color stability and hardness of two denture liners obtained by direct and indirect techniques, after thermal cycling and immersion in beverages that can cause staining of teeth. MATERIAL AND METHODS: Seventy disc-shaped specimens (18 x 3 mm) processed by direct (DT) and indirect techniques (IT) were made from Elite soft (n=35) and Kooliner (n=35) denture liners. For each material and technique, 10 specimens were subjected to thermal cycling (3,000 cycles) and 25 specimens were stored in water, coffee, tea, soda and red wine for 36 days. The values of color change, Shore A hardness (Elite soft) and Knoop hardness (Kooliner) were obtained. The data were subjected to ANOVA, Tukey's multiple-comparison test, and Kruskal-Wallis test (P<0.05). RESULTS: The thermal cycling promoted a decrease on hardness of Kooliner regardless of the technique used (Initial: 9.09± 1.61; Thermal cycling: 7.77± 1.47) and promoted an increase in the hardness in the DT for Elite Soft (Initial: 40.63± 1.07; Thermal cycling: 43.53± 1.03); hardness of Kooliner (DT: 8.76± 0.95; IT: 7.70± 1.62) and Elite Soft (DT: 42.75± 1.54; IT=39.30± 2.31) from the DT suffered an increase after the immersion in the beverages. The thermal cycling promoted color change only for Kooliner in the IT. Immersion in the beverages did not promote color change for Elite in both techniques. The control group of the DT of Kooliner showed a significant color change. Wine and coffee produced the greatest color change in the DT only for Elite Soft when compared to the other beverages. CONCLUSION: The three variation factors promoted alteration on hardness and color of the tested denture lining materials.
Resumo:
The present study evaluated the effect of repeated simulated microwave disinfection on physical and mechanical properties of Clássico, Onda-Cryl and QC-20 denture base acrylic resins. Aluminum patterns were included in metallic or plastic flasks with dental stone following the traditional packing method. The powder/liquid mixing ratio was established according to the manufacturer's instructions. After water-bath polymerization at 74ºC for 9 h, boiling water for 20 min or microwave energy at 900 W for 10 min, the specimens were deflasked after flask cooling and finished. Each specimen was immersed in 150 mL of distilled water and underwent 5 disinfection cycles in a microwave oven set at 650 W for 3 min. Non-disinfected and disinfected specimens were subjected to the following tets: Knoop hardness test was performed with 25 g load for 10 s, impact strength test was done using the Charpy system with 40 kpcm, and 3-point bending test (flexural strength) was performed at a crosshead speed of 0.5 mm/min until fracture. Data were analyzed statistically by ANOVA and Tukey's test (α= 0.05%). Repeated simulated microwave disinfections decreased the Knoop hardness of Clássico and Onda-Cryl resins and had no effect on the impact strength of QC-20. The flexural strength was similar for all tested resins.
Resumo:
The present work describes a new species of Baurusuchidae from Upper Cretaceous sediments of the Bauru Basin, and provides the first complete postcranial description for the family. Many postcranial features observed in the new species are also present in other notosuchian taxa, and are thus considered plesiomorphic for the genus. These are: long cervical neural spines; robust deltopectoral crest of the humerus; large proximal portion in the radiale that contacts the ulna; ulnare anterior distal projection; supra-acetabular crest well developed laterally; post-acetabular process posterodorsally deflected; presence of an anteromedial crest in the femur; fourth trocanter of femur posteriorly positioned; tibia with a laterally curved shaft; calcaneum tuber posteroventrally oriented; osteoderms ornamented with grooves and imbricated in the tail. On the other hand, we found the following sacral and carpal features to be unique among all mesoeucrocodylians analyzed: transverse processes of sacral vertebrae dorsolaterally deflected; presence of a longitudinal crest in the lateral surface of sacral vertebrae; pisiform carpal with a condyle-like surface. The majority of these cited features corroborates a cursorial locomotion for the new species described in the present study, suggesting that members of the family Baurusuchidae were also cursorial species.
Resumo:
We investigate synchronization in a Kuramoto-like model with nearest neighbor coupling. Upon analyzing the behavior of individual oscillators at the onset of complete synchronization, we show that the time interval between bursts in the time dependence of the frequencies of the oscillators exhibits universal scaling and blows up at the critical coupling strength. We also bring out a key mechanism that leads to phase locking. Finally, we deduce forms for the phases and frequencies at the onset of complete synchronization.
Resumo:
The complete genome sequences of two Brazilian wild-type rabies viruses (RABV), a BR-DR1 isolate from a haematophagous bat (Desmodus rotundus) and a BR-AL1 isolate from a frugivorous bat (Artibeus lituratus), were determined. The genomes of the BR-DR1 and RR-AL1 had 11,923 and 11,922 nt, respectively, and both encoded the five standard genes of rhabdoviruses. The complete nucleotide sequence identity between the BR-DR1 and BR-AL1 isolates was 97%. The BR-DR1 and BR-AL1 isolates had some conserved functional sites revealed by the fixed isolates, whereas both isolates had unique amino acid substitutions in the antigenic region IV of the nucleocapsid gene. Therefore, it is speculated that both isolates were nearly identical in virologic character. According to our phylogenetic analysis based on the complete genomes, both isolates belonged to genotype 1, and to the previously defined ""vampire bat-related RABV lineage"" which consisted of mainly D. rotundus- and A. lituratus- isolates; however, a branch pattern with high bootstrap values suggested that BR-DR1 was more closely related to the 9001FRA isolate, which was collected from a dog bitten by a bat in French Guiana, than to BR-AL1. This result suggests that the vampire bat-related RABV lineage includes Brazilian vampire bat and Brazilian frugivorous bat RABV and is further divided into Brazilian vampire bat and Brazilian frugivorous bat RABV sub-lineages. The phylogenetic analysis based on the complete genomes was valuable in discriminating among very closely related isolates.
Resumo:
Objective: To verify the relationship between maxillary and mandibular effective lengths and dental crowding in patients with Class II malocclusions. Materials and Methods: The sample comprised 80 orthodontic patients with complete Class II malocclusions in the permanent dentition (47 male, 33 female) who were divided into two groups according to the amount of mandibular tooth-arch size discrepancy. The maxillary and mandibular effective lengths (Co-A and Co-Gn) and tooth-arch size discrepancies were measured on the initial cephalograms and dental casts, respectively. Intergroup comparisons of apical base lengths were performed with independent t-tests. Correlation between base length and dental crowding was examined by means of Pearson's correlation coefficient (P < .05). Results: Patients with Class II malocclusion and moderate to severe crowding had significantly smaller maxillary and mandibular effective lengths than subjects with the same malocclusion and slight mandibular crowding. A weak inverse correlation was also found between maxillary and mandibular effective lengths and the severity of dental crowding. Conclusion: Decreased maxillary and mandibular effective lengths constitute an important factor associated with dental crowding in patients with complete Class II malocclusion. (Angle Orthod. 2011;81:217-221.)