898 resultados para correlation coefficients


Relevância:

60.00% 60.00%

Publicador:

Resumo:

The purpose of this experiment was to assess the test-retest reliability of input-output parameters of the cortico-spinal pathway derived from transcranial magnetic (TMS) and electrical (TES) stimulation at rest and during muscle contraction. Motor evoked potentials (MEPs) were recorded from the first dorsal interosseous muscle of eight individuals on three separate days. The intensity of TMS at rest was varied from 5% below threshold to the maximal output of the stimulator. During trials in which the muscle was active, TMS and TES intensities were selected that elicited MEPs of between 150 and 300 X at rest. MEPs were evoked while the participants exerted torques up to 50% of their maximum capacity. The relationship between MEP size and stimulus intensity at rest was sigmoidal (R-2 = 0.97). Intra-class correlation coefficients (ICC) ranged between 0.47 and 0.81 for the parameters of the sigmoid function. For the active trials, the slope and intercept of regression equations of MEP size on level of background contraction were obtained more reliably for TES (ICC = 0.63 and 0.78, respectively) than for TMS (ICC = 0.50 and 0.53, respectively), These results suggest that input-output parameters of the cortico-spinal pathway may be reliably obtained via transcranial stimulation during longitudinal investigations of cortico-spinal plasticity. (C) 2001 Elsevier Science B.V. All rights reserved.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The effects of such solutes such as halides and water on the physical properties of room temperature ionic liquids (RTILs) have been extensively studied, This work examines the effect of the solute carbon dioxide on the RTIL 1-ethyl-3-methylimidazolium bis(trifluoromethane-sulfonyl)imide ([C(2)mim][NTf2]) and its influence on the electrochemical characterization of the important redox couple ferrocene/ferrocenium (Fc/Fc(+)). The system was studied using cyclic voltammetry, chronoamperometry, and electron spin resonance (ESR) spectroscopy. Addition Of 100% CO2 to a solution of Fc in [C(2)mim][NTf2] resulted in a substantial increase in both the limiting oxidative current and diffusion coefficient of Fc. Arrhenius plots of Fc diffusion coefficients in the pure and CO2-saturated ionic liquid revealed a decrease in activation energy of translational diffusion from 29.0 (+/- 0.5) kJ mol(-1) to 14.7 (+/- 1.6) kJ mol(-1), suggesting a reduction in the viscosity of the ionic liquid with addition Of CO2. ESR spectroscopy was then used to calculate the rotational correlation coefficients of a probe molecule, 2,2,6,6-tetramethyl-1-piperinyloxyl (TEMPO), to add supporting evidence to this hypothesis. Arrhenius plots of rotational correlation coefficients in the pure and CO2-saturated ionic liquid resulted in a similar drop in activation energy from 28.7 (+/- 2.1) kJ mol(-1) to 18.2 (+/- 5.6) kJ mol(-1). The effect of this solute on the ionic liquid [C(2)mim][NTf2] and on the electrochemical measurements of the Fc/Fc(+) couple emphasizes the necessity of fastidious sample preparation, as it is clear that the voltammetric currents of the electroactive species under study are influenced by the presence of CO2 in solution. The voltammetric response of the electroactive species in RTILs cannot be assumed to be independent of other solutes.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Objectives: To determine the interobserver reliability of radiologists' interpretations of mobile chest radiographs for nursing home-acquired pneumonia. Design: A cross-sectional reliability study. Setting: Nursing homes and an acute care hospital. Participants: Four radiologists reviewed 40 mobile chest radiographs obtained from residents of nursing homes who met a clinical definition of lower respiratory tract infections. Measurements: Radiologists were asked to interpret radiographs with respect to the film quality; presence, pattern, and extent of an infiltrate; and the presence of a pleural effusion or adenopathy. Interrater reliability was evaluated using the intraclass correlation coefficient derived from a 2-way random effects model. Results: On average the radiologists reported that 6 of the 40 films were of very good or excellent quality and 16 of the 40 were of fair or poor quality. When the finding of an infiltrate was dichotomized (0 = no; 1 = possible, probable, or definite) all 4 radiologists agreed on 21 of the 37 chest radiographs. The intraclass correlation coefficient for the presence or absence of infiltrates was 0.54 (95% confidence intervals [CI] 0.38 to 0.69). For the 14 radiographs where infiltrates were observed by all radiologists, intraclass correlation coefficients for the presence of pleural effusions was 0.08 (95% CI -0.10 to 0.41), hilar adenopathy 0.54 (95% CI 0.29 to 0.79), and mediastinal adenopathy 0.49 (95% CI 0.21 to 0.76). Conclusion: In conclusion, the interrater agreement among radiologists for mobile chest radiographs in establishing the presence or absence of an infiltrate can be judged to be "fair." Treatment decisions need to include clinical findings and should not be made based on radiographic findings alone. © 2006 American Medical Directors Association.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Data obtained with any research tool must be reproducible, a concept referred to as reliability. Three techniques are often used to evaluate reliability of tools using continuous data in aging research: intraclass correlation coefficients (ICC), Pearson correlations, and paired t tests. These are often construed as equivalent when applied to reliability. This is not correct, and may lead researchers to select instruments based on statistics that may not reflect actual reliability. The purpose of this paper is to compare the reliability estimates produced by these three techniques and determine the preferable technique. A hypothetical dataset was produced to evaluate the reliability estimates obtained with ICC, Pearson correlations, and paired t tests in three different situations. For each situation two sets of 20 observations were created to simulate an intrarater or inter-rater paradigm, based on 20 participants with two observations per participant. Situations were designed to demonstrate good agreement, systematic bias, or substantial random measurement error. In the situation demonstrating good agreement, all three techniques supported the conclusion that the data were reliable. In the situation demonstrating systematic bias, the ICC and t test suggested the data were not reliable, whereas the Pearson correlation suggested high reliability despite the systematic discrepancy. In the situation representing substantial random measurement error where low reliability was expected, the ICC and Pearson coefficient accurately illustrated this. The t test suggested the data were reliable. The ICC is the preferred technique to measure reliability. Although there are some limitations associated with the use of this technique, they can be overcome.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Aims - To study the interchangeability of the measurements of the optic disc topography obtained by one computerised image analyser and one confocal laser tomographic scanner. Methods - One eye of 28 patients with glaucoma or glaucoma suspects was studied. All cases had simultaneous stereoscopic disc photographs taken with the fundus camera Topcon TRC-SS and optic disc examination with the Heidelberg retina tomograph (HRT) during the same visit. The optic disc photographs were digitised and analysed with the Topcon ImageNet (TI) system. Three variables of the optic disc topography provided by the TI and the HRT were compared - cup volume (CV), rim area (RA), and cup area to disc area ratio (CA/DA). Results - The mean values of CV and RA provided by the TI (0.52 (SD 0.32) mm and 1.58 (0.39) mm , respectively) were greater (p <0.01) than the mean values of CV and RA determined by the HRT (0.32 (0.25) mm , and 1.33 (0.47) mm , respectively). The mean value of CA/DA provided by the TI (0.42 (0.14)) and the HRT (0.42 (0.18)) was similar (p = 0.93). Correlation coefficients between measurements obtained by the two methods ranged from 0.53 to 0.73. Conclusion - There was a significant discrepancy in the measurements of rim area and cup volume of the optic disc obtained by a computerised image analyser and a laser scanning tomograph.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Purpose: To compare two fast threshold strategies of visual field assessment; SITA Fast (HSF) and Tendency Orientated Perimetry (TOP), in detecting visual field loss in patients with glaucoma. Methods: Seventy-six glaucoma, ocular hypertensive and normal patients had HSF and TOP performed in random order. Quantitative comparisons for the global visual field indices - mean deviation and defect (MD) for HSF and TOP, and pattern standard deviation (PSD) for HSF and loss variance (LV) for TOP - were made using correlation coefficients. Humphrey global parameters were converted to Octopus equivalents, and method comparison analysis was used to determine agreement between the two strategies. Test duration times were compared using t-test. Sensitivity and specificity for these two algorithms were determined according to predetermined criteria. Results: High correlation coefficient values were obtained for MD measurements between HSF and TOP (r=-0.89, P

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The technique of diffusive gradients in thin films (DGT) is often employed to quantify labile metals in situ; however, it is a challenge to perform the measurements in-field. This study evaluated the capability of field-portable X-ray fluorescence (FP-XRF) to swiftly generate elemental speciation information with DGT. Biologically available metal ions in environmental samples passively preconcentrate in the thin films of DGT devices, providing an ideal and uniform matrix for XRF nondestructive detection. Strong correlation coefficients (r > 0.992 for Mn, Cu, Zn, Pb and As) were obtained for all elements during calibration. The limits of quantitation (LOQ) for the investigated elements of FP-XRF on DGT devices are 2.74 for Mn, 4.89 for Cu, 2.89 for Zn, 2.55 for Pb, and 0.48 for As (unit: µg cm(-2)). When Pb and As co-existed in the solution trials, As did not interfere with Pb detection when using Chelex-DGT. However, there was a significant enhancement of the Pb reading attributed to As when ferrihydrite binding gels were tested, consistent with Fe-oxyhydroxide surfaces absorbing large quantities of As. This study demonstrates the value of the FP-XRF technique to rapidly and nondestructively detect the metals accumulated in DGT devices, providing a new and simple diagnostic tool for on-site environmental monitoring of labile metals/metalloids

Relevância:

60.00% 60.00%

Publicador:

Resumo:

BACKGROUND: The new generation of activity monitors allow users to upload their data to the internet and review progress. The aim of this study is to validate the Fitbit Zip as a measure of free-living physical activity.

FINDINGS: Participants wore a Fitbit Zip, ActiGraph GT3X accelerometer and a Yamax CW700 pedometer for seven days. Participants were asked their opinion on the utility of the Fitbit Zip. Validity was assessed by comparing the output using Spearman's rank correlation coefficients, Wilcoxon signed rank tests and Bland-Altman plots. 59.5% (25/47) of the cohort were female. There was a high correlation in steps/day between the Fitbit Zip and the two reference devices (r = 0.91, p < 0.001). No statistically significant difference between the Fitbit and Yamax steps/day was observed (Median (IQR) 7477 (3597) vs 6774 (3851); p = 0.11). The Fitbit measured significantly more steps/day than the Actigraph (7477 (3597) vs 6774 (3851); p < 0.001). Bland-Altman plots revealed no systematic differences between the devices.

CONCLUSIONS: Given the high level of correlation and no apparent systematic biases in the Bland Altman plots, the use of Fitbit Zip as a measure of physical activity. However the Fitbit Zip recorded a significantly higher number of steps per day than the Actigraph.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

BACKGROUND: Assessing methodological quality of primary studies is an essential component of systematic reviews. Following a systematic review which used a domain based system [United States Preventative Services Task Force (USPSTF)] to assess methodological quality, a commonly used numerical rating scale (Downs and Black) was also used to evaluate the included studies and comparisons were made between quality ratings assigned using the two different methods. Both tools were used to assess the 20 randomized and quasi-randomized controlled trials examining an exercise intervention for chronic musculoskeletal pain which were included in the review. Inter-rater reliability and levels of agreement were determined using intraclass correlation coefficients (ICC). Influence of quality on pooled effect size was examined by calculating the between group standardized mean difference (SMD).

RESULTS: Inter-rater reliability indicated at least substantial levels of agreement for the USPSTF system (ICC 0.85; 95% CI 0.66, 0.94) and Downs and Black scale (ICC 0.94; 95% CI 0.84, 0.97). Overall level of agreement between tools (ICC 0.80; 95% CI 0.57, 0.92) was also good. However, the USPSTF system identified a number of studies (n = 3/20) as "poor" due to potential risks of bias. Analysis revealed substantially greater pooled effect sizes in these studies (SMD -2.51; 95% CI -4.21, -0.82) compared to those rated as "fair" (SMD -0.45; 95% CI -0.65, -0.25) or "good" (SMD -0.38; 95% CI -0.69, -0.08).

CONCLUSIONS: In this example, use of a numerical rating scale failed to identify studies at increased risk of bias, and could have potentially led to imprecise estimates of treatment effect. Although based on a small number of included studies within an existing systematic review, we found the domain based system provided a more structured framework by which qualitative decisions concerning overall quality could be made, and was useful for detecting potential sources of bias in the available evidence.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

PURPOSE:

This study investigated the heritability of lens thickness (LT) and relative lens thickness (LT/axial length, rLT) measured by Lenstar among Chinese children and adolescents in the Guangzhou Twin Eye study.

METHODS:

Twins aged 8 to 22 years were enrolled from the Guangzhou Twin Registry. A series of LT and axial length (AL) measurements using the Lenstar were taken for each twin. Zygosity was confirmed by genotyping in all same-sex twin pairs. Heritability was assessed by structural variance component genetic modeling, after adjustment for age and sex with the Mx program.

RESULTS:

Seven hundred sixty-eight twin pairs (482 monozygotic [MZ] and 286 dizygotic [DZ] twins) were available for data analysis. The mean (standard deviation) LT and rLT were 3.45 (0.18) mm and 0.142 (0.01), respectively. The intraclass correlation coefficients (ICCs) for LT were 0.90 for the MZ and 0.39 for the DZ twins; and those for rLT were 0.90 for the MZ and 0.40 for the DZ twins, respectively. The best-fitting model yielded 89.5% (95% CI: 87.8%-91.0%) of additive genetic effects and 10.5% (95% CI: 9.0%-12.2%) of unique environmental effects for LT, and 89.3% (95% CI: 89.2%-89.3%) of additive genetic effects and 10.7% (95% CI: 10.7%-11.4%) of unique environmental effects for rLT.

CONCLUSIONS:

This study confirms that the LT in young healthy subjects may be mainly affected by additive genetic factors. High heritability remains even when the data are corrected for the influence of AL with the use of rLT.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Food preparation and storage behaviors in the home deviating from the ‘best practice’ food safety recommendations may result in food borne illnesses. Currently, there are limited tools available to fully evaluate the consumer knowledge, perceptions and behavior in the area of refrigerator safety. The current study aimed to develop a valid and reliable tool in the form of a questionnaire (CFSQCRSQ) for assessing systematically all these aspects. Items relating to refrigerator safety knowledge (n=17), perceptions (n=46), reported behavior (n=30) were developed and pilot tested by an expert reference group and various consumer groups to assess face and content validity (n=20), item difficulty and item consistency (n=55) and construct validity (n=23). The findings showed that the CFSQCRSQ has acceptable face and content validity with acceptable levels of item difficulty. Item consistency was observed for 12 out of 15 refrigerator safety knowledge. Further, all five of the subscales of consumer perceptions of refrigerator safety practices relating to risk of developing foodborne disease food poisoning showed acceptable internal consistency (Cronbach’s α value > 0.8). Construct validity of the CFSQCRSQ was shown to be very good (p=0.022). The CFSQCRSQ exhibited acceptable test-retest reliability at 14 days with majority of knowledge items (93.3%) and reported behavior items (96.4%) having correlation coefficients of greater than 0.70. Overall, the CFSQCRSQ was deemed valid and reliable in assessing refrigerator safety knowledge and behavior and therefore has the potential for future use in identifying groups of individuals at increased risk of deviating from recommended refrigerator safety practices as well as the assessment of refrigerator safety knowledge, behavior for use before and after an intervention.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

O presente trabalho tem como objetivo analisar a cinética de secagem do bacalhau salgado verde (Gadus morhua) em secador convectivo. É apresentada a análise da composição físico-química dos bacalhaus utilizados nos ensaios experimentais, bem como o estudo das isotermas de sorção do produto, através de experiências e modelação matemática. Dos modelos usados para o ajuste das isotermas de sorção do bacalhau salgado verde, o que melhor se adaptou aos resultados experimentais foi o modelo de GAB Modificado, com coeficientes de correlação variando entre 0,992 e 0,998. Para o controlo do processo de secagem (nomeadamente os parâmetros temperatura, humidade relativa e velocidade do ar) foi utilizada lógica difusa, através do desenvolvimento de controladores difusos para o humidificador, desumidificador, resistências de aquecimento e ventilador. A modelação do processo de secagem foi realizada através de redes neuronais artificiais (RNA), modelo semi-empírico de Page e modelo difusivo de Fick. A comparação entre dados experimentais e simulados, para cada modelo, apresentou os seguintes erros: entre 1,43 e 11,58 para o modelo de Page, 0,34 e 4,59 para o modelo de Fick e entre 1,13 e 6,99 para a RNA, com médias de 4,38, 1,67 e 2,93 respectivamente. O modelo obtido pelas redes neuronais artificiais foi submetido a um algoritmo de otimização, a fim de buscar os parâmetros ideais de secagem, de forma a minimizar o tempo do processo e maximizar a perda de água do bacalhau. Os parâmetros ótimos obtidos para o processo de secagem, após otimização realizada, para obter-se uma humidade adimensional final de 0,65 foram: tempo de 68,6h, temperatura de 21,45°C, humidade relativa de 51,6% e velocidade de 1,5m/s. Foram também determinados os custos de secagem para as diferentes condições operacionais na instalação experimental. Os consumos por hora de secagem variaram entre 1,15 kWh e 2,87kWh, com uma média de 1,94kWh.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

A multiresidue gas chromatographic method for the determination of six fungicides (captan, chlorthalonil, folpet, iprodione, procymidone and vinclozolin) and one acaricide (dicofol) in still and fortified wines was developed. Solid-phase microextraction (SPME) was chosen for the extraction of the compounds from the studied matrices and tandem mass spectrometry (MS/MS) detection was used. The extraction consists in a solvent free and automated procedure and the detection is highly sensitive and selective. Good linearity was obtained with correlation coefficients of regression (R2) > 0.99 for all the compounds. Satisfactory results of repeatability and intermediate precision were obtained for most of the analytes (RSD < 20%). Recoveries from spiked wine ranged from 80.1% to 112.0%. Limits of quantification (LOQs) were considerably below the proposedmaximumresidue limits (MRLs) for these compounds in grapes and below the suggested limits for wine (MRLs/10), with the exception of captan.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

A promoção de competências de leitura é um tema central, tanto na educação regular, como na educação especial em crianças em idade pré-escolar e escolar. Todavia, as competências de leitura de indivíduos adultos com incapacidade intelectual são um domínio muito pouco estudado. São também escassos os estudos direcionados à avaliação dessas competências. Esta investigação propõe uma tradução/ adaptação do APAR (Assessment of Phonological Awareness and Reading), um protocolo de avaliação da consciência fonológica (CF) e da leitura especificamente concebido para a população em estudo. Procura-se também analisar os processos cognitivos envolvidos na leitura nos quais a intervenção produzirá resultados mais significativos e confirmar uma relação positiva entre a avaliação prévia de competências escolares em contexto formativo profissional e o efetivo desenvolvimento de competências de leitura. Foram avaliadas em dois momentos (pré e pós-teste) a CF e competências de leitura de 12 adultos com incapacidade intelectual ligeira, sendo estes sujeitos a um programa de intervenção, visando áreas menos desenvolvidas das suas competências que possibilitassem desempenhos de leitura mais fortes. Ao nível da análise quantitativa, foram comparados os resultados obtidos nos dois momentos de administração. No tratamento estatístico recorreu-se a análises de correlação de Spearman para determinar a presença de indicadores de desempenho ao nível da CF e ao cálculo de coeficientes de correlação de Pearson e Spearman para controlar variáveis externas como idade, sexo e habilitações literárias. Os resultados obtidos revelam desempenhos fracos ao nível da leitura/ compreensão textual e, em particular, da CF em pré-teste e ganhos significativos globais após implementação de uma intervenção baseada em medidas de avaliação prévia de competências de leitura/compreensão e CF

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Carbamate compounds are an important group of cholinesterase inhibitors. There is a need for creating awareness regarding the risks of the inadequate carbamate use in the residential areas due to potential adverse human effects. Carbaryl is a commonly used pesticide worldwide. A simple, fast, and high throughput method was developed employing liquid chromatography with fluorescence detector to determine carbaryl residues in rat feces. The extraction was performed by using a rapid, easy, cheap, effective, reliable, and safe (QuEChERS) method, using acetonitrile as the extracting solvent. The parameters for the performance of the extraction method were optimized, such as ratio of mass of sample per volume of extraction solvent, QuEChERS content, and cleanup columns. Linear response was obtained for all calibration curves (solven and matrix-matched) over the established concentration range (5 500 mg/L) with a correlation coefficients higher than 0.999. The achieved recovery was 97.9% with relative standard deviation values of 1.1% (n D 4) at 167 mg/kg fortified concentration level and the limits of detection and quantification were 27.7 and 92.3 mg/kg respectively.