954 resultados para cooling equipment
Resumo:
The objective of this work was to determine physiological stress markers, neutrophil:lymphocyte ratio (N/L) and corticoid concentrations, in gestating sows under different cooling systems. A sprinkling cooling system (SS) and a system based on fan-assisted evaporative cellulose pad (PS) were used. SS showed higher N/L ratio (1.095) than PS (0.850). Corticoid concentrations showed high variability. Corticosteroids are more efficient short-term stress indicators while N/L ratio is a good medium and long-term stress indicator. According to N/L ratio, gestating sows under PS benefit from a higher level of welfare.
Resumo:
The Equipment and Vehicle Revolving Fund report covers all equipment and vehicle purchases through the highway materials and equipment revolving fund during FY 2015.
Resumo:
This piece of work which is Identification of Research Portfolio for Development of Filtration Equipment aims at presenting a novel approach to identify promising research topics in the field of design and development of filtration equipment and processes. The projected approach consists of identifying technological problems often encountered in filtration processes. The sources of information for the problem retrieval were patent documents and scientific papers that discussed filtration equipments and processes. The problem identification method adopted in this work focussed on the semantic nature of a sentence in order to generate series of subject-action-object structures. This was achieved with software called Knowledgist. List of problems often encountered in filtration processes that have been mentioned in patent documents and scientific papers were generated. These problems were carefully studied and categorized. Suggestions were made on the various classes of these problems that need further investigation in order to propose a research portfolio. The uses and importance of other methods of information retrieval were also highlighted in this work.
Resumo:
The rotational speed of high-speed electric machines is over 15 000 rpm. These machines are compact in size when compared to the power rate. As a consequence, the heat fluxes are at a high level and the adequacy of cooling becomes an important design criterion. In the high-speed machines, the air gap between the stator and rotor is a narrow flow channel. The cooling air is produced with a fan and the flow is then directed to the air gap. The flow in the gap does not provide sufficient cooling for the stator end windings, and therefore additional cooling is required. This study investigates the heat transfer and flow fields around the coil end windings when cooling jets are used. As a result, an innovative and new assembly is introduced for the cooling jets, with the benefits of a reduced amount of hot spots, a lower pressure drop, and hence a lower power need for the cooling fan. The gained information can also be applied to improve the cooling of electric machines through geometry modifications. The objective of the research is to determine the locations of the hot spots and to find out induced pressure losses with different jet alternatives. Several possibilities to arrange the extra cooling are considered. In the suggested approach cooling is provided by using a row of air jets. The air jets have three main tasks: to cool the coils effectively by direct impingement jets, to increase and cool down the flow that enters the coil end space through the air gap, and to ensure the correct distribution of the flow by forming an air curtain with additional jets. One important aim of this study is the arrangement of cooling jets in such manner that hot spots can be avoided to wide extent. This enables higher power density in high-speed motors. This cooling system can also be applied to the ordinary electric machines when efficient cooling is needed. The numerical calculations have been performed using a commercial Computational Fluid Dynamics software. Two geometries have been generated: cylindrical for the studied machine and Cartesian for the experimental model. The main parameters include the positions, arrangements and number of jets, the jet diameters, and the jet velocities. The investigated cases have been tested with two widely used turbulence models and using a computational grid of over 500 000 cells. The experimental tests have been made by using a simplified model for the end winding space with cooling jets. In the experiments, an emphasis has been given to flow visualisation. The computational analysis shows good agreement with the experimental results. Modelling of the cooling jet arrangement enables also a better understanding of the complex system of heat transfer at end winding space.
Resumo:
Työn tavoitteena oli tutkia hyvän asiakasreferenssin ominaisuuksia suodatinvalmistaja Laroxin myynnin ja huollon sekä yrityksen asiakkaiden näkökulmasta. Larox voi käyttää saatua tietoa referenssien tehokkaampaan valintaan ja hyödyntämiseen. Kaksi internet-kyselyä toteutettiin, välineenä Webropol. Alustava kysely sunnattiin Laroxin myynnille ja huollolle. Kysely koostui viidestä kategoriasta asiakasreferenssejä, joiden tärkeyttä arvioitiin, sekä vapaista vastauksista. Tunnistettuja hyvän asiakasreferenssin ominaisuuksia ovat hyvä suhde referenssiasiakkaaseen, positiiviset jarehelliset suosittelut asiakkaalta, referenssilaitteen hyvä toimintakyky ja asiakas joka ymmärtää huollon tärkeyden. Pääkysely suunnattiin Laroxin asiakkaille. Tilastollisilla analyyseilla tutkittiin koetun riskin mallinmuuttujien välisiä yhteyksiä. Analyysit eivät paljastaneet merkittäviä riippuvuuksia asiakasreferenssin ominaisuuksien tärkeydessä eritaustaisten vastaajien tai tilannetekijöiden välillä, mutta asiakasreferenssin ominaisuuksien faktorit tukevat mallia. Referenssilaitteiden toimintakyky vaikuttaa tärkeimmältä ja huollon tärkeys on myös merkittävä.
Resumo:
Container Handling Equipment Monitoring System (CHEMS) is a system developed by Savcor One Oy. CHEMS measures important information for container ports performance and produces performance indicators. The aim of this thesis was to clarify performance measurement contents to Savcor and to develop, as an example, performance measures to Steveco Oy's container operations. The theoretical part of the thesis clarifies performance measurement and which of its components are important to container port. Performance measurement and measures are presented from the operational level's point of view, in which CHEMS is planned to aim. The theory of development process of performance measures is introduced at the end of the theoretical part. To make sure that performance measures are efficiently used, Steveco Oy's performance measures are developed in cooperation with the users. The measurement in operational level is continuous and the results must be reacted asquickly as possible. CHEMS is very suitable to continuous measurement and to produce real time-measures of container operations which are hard to get any otherway.
Resumo:
Every medical practitioner is confronted on a daily basis with emergencies. Among these, life-threatening emergencies can have disastrous consequences in term of morbidity and mortality; 22 cardiac arrests and 10 deaths were reported among the 1,650 Swiss practices during a 5 year period. The occurrence of life-threatening emergencies at the office necessitates, according to the type and place of the practice, the skills of the practitioner and the organization of his practice, the implementation of procedures, equipments (for example room equipped with a defibrillator, respiratory nebulizer, splints, emergency drugs) and specific continuous education programs that should be encouraged and made available to the whole medical corporation.
Resumo:
In this thesis the membrane filtration equipment for plate type ceramic membranes was developed based on filtration results achieved with different kinds of wastewaters. The experiments were mainly made with pulp and board mill wastewaters, but some experiments were also made with a bore well water and a stone cutting mine wastewater. The ceramicmembranes used were alpha-alumina membranes with a pore size of 100 nm. Some ofthe membranes were coated with a gamma-alumina layer to reduce the membrane pore size to 10 nm, and some of them were modified with different metal oxides in order to change the surface properties of the membranes. The effects of operationparameters, such as cross-flow velocity, filtration pressure and backflushing on filtration performance were studied. The measured parameters were the permeateflux, the quality of the permeate, as well as the fouling tendency of the membrane. A dynamic membrane or a cake layer forming on top of the membrane was observed to decrease the flux and increase separa-tion of certain substances, especially at low cross-flow velocities. When the cross-flow velocities were increased the membrane properties became more important. Backflushing could also be used to decrease the thickness of the cake layer and thus it improved the permeate flux. However, backflushing can lead to a reduction of retentions in cases where the cake layer is improving them. The wastewater quality was important for the thickness of the dynamic membrane and the membrane pore size influenced the permeate flux. In general, the optimization of operation conditions is very important for the successful operation of a membrane filtration system. The filtration equipment with a reasonable range of operational conditions is necessary, especiallywhen different kinds of wastewaters are treated. This should be taken into account already in the development stage of a filtration equipment.
Resumo:
The introduction of affordable, consumer-oriented 3-D printers is a milestone in the current "maker movement," which has been heralded as the next industrial revolution. Combined with free and open sharing of detailed design blueprints and accessible development tools, rapid prototypes of complex products can now be assembled in one's own garage--a game-changer reminiscent of the early days of personal computing. At the same time, 3-D printing has also allowed the scientific and engineering community to build the "little things" that help a lab get up and running much faster and easier than ever before.
Resumo:
BACKGROUND: Therapeutic hypothermia following hypoxic ischaemic encephalopathy in term infants was introduced into Switzerland in 2005. Initial documentation of perinatal and resuscitation details was poor and neuromonitoring insufficient. In 2011, a National Asphyxia and Cooling Register was introduced. AIMS: To compare management of cooled infants before and after introduction of the register concerning documentation, neuromonitoring, cooling methods and evaluation of temperature variability between cooling methods. STUDY DESIGN: Data of cooled infants before the register was in place (first time period: 2005-2010) and afterwards (second time period: 2011-2012) was collected with a case report form. RESULTS: 150 infants were cooled during the first time period and 97 during the second time period. Most infants were cooled passively or passively with gel packs during both time periods (82% in 2005-2010 vs 70% in 2011-2012), however more infants were cooled actively during the second time period (18% versus 30%). Overall there was a significant reduction in temperature variability (p < 0.001) comparing the two time periods. A significantly higher proportion of temperature measurements within target temperature range (72% versus 77%, p < 0.001), fewer temperature measurements above (24% versus 7%, p < 0.001) and more temperatures below target range (4% versus 16%, p < 0.001) were recorded during the second time period. Neuromonitoring improved after introduction of the cooling register. CONCLUSION: Management of infants with HIE improved since introducing the register. Temperature variability was reduced, more temperature measurements in the target range and fewer temperature measurements above target range were observed. Neuromonitoring has improved, however imaging should be performed more often.
Resumo:
Työn tavoitteena oli arvioida ja selvittää toimittajasuhteeseen vaikuttavia tekijöitä JOT Automation Group Oyj.n ja sen alihankkijoiden välisessä yhteistyössä ja muodostaa yrityksen kilpailukykyä parantava toimittaja-arviointiprosessi. Työssä keskityttiin tarkastelemaan yleisillä materiaali- ja komponenttimarkkinoilla toimivia toimittajia elektroniikkateollisuuden tuotantojärjestelmien valmistuksessa. Ensin tutustuttiin toimittajasuhdetta ja sen arviointia käsitelleeseen kirjallisuuteen. Teorian tueksi tehtiin haastatteluja ja kartoitettiin ensisijaisia tarpeita ja tavoitteita arviointiprosessille. Valmis prosessi testattiin käytännössä kahden eri case-esimerkin avulla. Prosessista muodostui kahteen eri työkaluun jakautunut kokonaisuus, joista auditointi arvioi toimittajan kyvykkyyttä vastatta sille asetettuihin vaatimuksiin. Toimittajan suorituskyvyn mittaaminen puolestaan testaa ja vertaa jatkuvasti toiminnan todellista tasoa auditoinnissa saatuihin tuloksiin. Työ sisältää selvityksen ja ohjeistuksen toimittaja-arviointiprosessin käytöstä. Prosessin käyttö alentaa toimittajaan kohdistuvaa materiaalien saatavuuteen ja hankintaan liittyviä riskejä. Esimerkeistä saadut kokemukset osoittivat, että prosessin avulla päästään pureutumaan tärkeisiin ydinalueisiin ja kehittämään niitä sekä toimittajalle, että ostajayritykselle edullisella tavalla. Toimittaja-arviointiprosessista kehittyy toimintatapa yrityksen ja sen toimittajan välisen suhteen ylläpitämiseksi.
Resumo:
Kivihiokkeen valmistus on energiaintensiivistä. Käytetystä energiasta muuttuu yli 90 prosenttia lämmöksi. Hiomolla käytetystä lämmöksi muuttuneesta tehosta voidaan paperikoneelle siirtää noin puolet. Mekaanisen massan valmistuksen ja paperikoneen vesikierrot erotetaan toisistaan häiriöaineiden kulkeutumisen estämiseksi. Vesikiertojen erottamisella katkaistaan myös lämmön siirtyminen hiomolta paperikoneelle massojen mukana. Käyttämällä lämmönsiirtimiä hiomon vesien jäähdytyksessä, voidaan hiomon hiomakoneiden suihkuvesivesilämpötilaa alentaa. Lämmönsiirto vaikuttaa paperikoneella annostelumassojen laimennusten kautta perälaatikkolämpötilaa kohottavasti. Työn tehtäväksi määritettiin kesäkuukausina esiintyvä hiomakoneiden suihkuveden raakavesijäähdytyksen tarpeen poistaminen ensisijaisesti niin, että ylimäärälämpö hyödynnetään tehtaalla. Työn muiksi tavoitteiksi muodostui annostelumassojen lämpötilan hallinta, etenkin muutokset, joilla voidaan nostaa hylkymassan annostelulämpötilaa. Työn kokeellinen osa tehtiin UPM Kymmene Oyj Kajaanin tehtailla syksyn 2004 aikana. Työssä tutkittiin WinGEMS simulointiohjelmalla tehtyjen mallien avulla lämmön siirtymistä hiomon ja paperikone 2:n välillä, sekä lämmönsiirtoa pois tasealueelta. Simulointimalli nykytilanteesta rakennettiin yksityiskohtaisesti nykyisen tuotantoprosessin kaltaiseksi ja siitä muokattiin eri vaihtoehtoja, joilla ratkaistiin tutkimukselle asetetut tehtävät. Kytkentämuutoksilla pystyttiin siirtämään hiomolta yli 85 % hiomakoneiden suihkuveden ylimäärälämmöstä ilman uusia laitehankintoja. Asentamalla lopuksi lämmönsiirrin hiomon puhdassuodoslinjaan, hiomakoneiden suihkuveden jäähdytystarve poistettiin kokonaan. Samalla alennettiin valkaisuun menevän massan lämpötilaa, jolloin peroksidivalkaisun kemikaalikulutus väheni yli 10 %. Lämmönsiirrinverkostosta tehtiin kesätilanteen pinch-analyysi, jolla selvitettiin prosessin lämmitys ja jäähdytystarpeet. Analyysin perusteella selvisi, että kytkennöissä ei rikota pinch sääntöjä ja, että prosessissa esiintyy kynnysongelma, jossa prosessi tarvitsee ainoastaan jäähdytystä.
Resumo:
Elektroniikan pienentyessä ja tehotiheyden kasvaessa tarvitaan paremmin suunniteltuja jäähdytysjärjestelyjä. Suunnittelun apuna voidaan käyttää perinteisiä lämmönsiirtoyhtälöitä, virtauslaskentaa ja mittauksia. Tässä työssä on suunniteltu ja rakennettu mittauslaitteisto nimenomaan elektroniikan komponenttien ja jäähdytyselementtien lämpötilojen ja painehäviöiden mittaamiseen. Koeajona laitteistolla on mitattu jäähdytyselementin lämpötilajakauma kahdella eri virtausnopeudella ja lämpötilalla sekä verrattu niitä aikaisemmin mitattuihin tapauksiin sekä Fluent- virtauslaskentaohjelmalla laskettuihin tuloksiin.
Resumo:
Opinnäytetyön tavoitteena oli analysoida ja kehittää lopputuotteiden varastointia Halton Oy:ssä. Työ toteutettiin, koska yrityksen laajasta tuotevalikoimasta monia nimikkeitä varastoidaan tällä hetkellä ja ne sitovat runsaasti pääomaa varastoon. Lisäksi yrityksellä on vain rajallinen varastointitila käytettävissä ja sitä haluttiin hyödyntää optimaalisesti. Työssä suunniteltiin yritykselle varastoitavien tuotenimikkeiden hallintaprosessi ja lisäksi tutkittiin kuinka yritys voisi tarjota tuotteitaan nopeammin tärkeimmille ulkomaan markkina-alueille. Työn alussa huomio kohdistui myynniltään vähemmän merkittäviin varastonimikkeisiin, joita analysoitiin suunniteltujen kriteerien avulla. Tarkoituksena oli selvittää, mitkä varastonimikkeistä voitaisiin siirtää tilausohjautuviksi. Tärkeimpinä analysointikriteereinä käytettiin nimikkeiden alhaista myyntimäärää, lyhyttä tuotannonläpimenoaikaa sekä varastoitavien nimikkeiden lukumäärää tuoteryhmässä. Työssä huomioitiin kuitenkin myös muita mahdollisia syitä varastointiin. Lisäksi tehtiin havaintoja tilausohjautuvista nimikkeistä, jotka saattaisivat tarvita varastointia. Suunniteltuun hallintaprosessiin sisältyi kriteerien lisäksi myös varastotasojen määrittäminen yrityksen nykyisen varastomallin pohjalta. Työssä tutkittiin kuitenkin myös mahdollisia tulevaisuuden varastomalleja, joiden tarkoituksena olisi parantaa asiakaspalvelua ulkomailla. Tutkimus keskittyi pääasiassa nimikkeiden kysyntöjen analysointiin eri varastomallien myyntialueilla.