820 resultados para continuous speech
Resumo:
The present paper reviews the findings of 30 years of verbal/manual dual task studies, the method most commonly used to assess lateralization of speech production in non-clinical samples. Meta-analysis of 64 results revealed that both the type of manual task used and the nature of practice that is given influence the size of the laterality effect. A meta-analysis of 36 results examining the effect size of sex differences in estimate,, of lateralization of speech production indicated that males appear to show, slightly larger laterality effects than females. (C) 2002 Elsevier Science Ltd. All rights reserved.
Resumo:
Landscape metrics are widely applied in landscape ecology to quantify landscape structure. However, many are poorly tested and require rigorous validation if they are to serve as reliable indicators of habitat loss and fragmentation, such as Montreal Process Indicator 1.1e. We apply a landscape ecology theory, supported by exploratory and confirmatory statistical techniques, to empirically test landscape metrics for reporting Montreal Process Indicator 1.1e in continuous dry eucalypt forests of sub-tropical Queensland, Australia. Target biota examined included: the Yellow-bellied Glider (Petaurus australis); the diversity of nectar and sap feeding glider species including P. australis, the Sugar Glider P. breviceps, the Squirrel Glider P. norfolcensis, and the Feathertail Glider Acrobates pygmaeus; six diurnal forest birds species; total diurnal bird species diversity; and the density of nectar-feeding diurnal bird species. Two scales of influence were considered: the stand-scale (2 ha), and a series of radial landscape extents (500 m - 2 km; 78 - 1250 ha) surrounding each fauna transect. For all biota, stand-scale structural and compositional attributes were found to be more influential than landscape metrics. For the Yellow-bellied Glider, the proportion of trace habitats with a residual element of old spotted-gum/ironbark eucalypt trees was a significant landscape metric at the 2 km landscape extent. This is a measure of habitat loss rather than habitat fragmentation. For the diversity of nectar and sap feeding glider species, the proportion of trace habitats with a high coefficient of variation in patch size at the 750 m extent was a significant landscape metric. None of the landscape metrics tested was important for diurnal forest birds. We conclude that no single landscape metric adequately captures the response of the region's forest biota per se. This poses a major challenge to regional reporting of Montreal Process Indicator 1.1e, fragmentation of forest types.
Resumo:
Compression amplification significantly alters the acoustic speech signal in comparison to linear amplification. The central hypothesis of the present study was that the compression settings of a two-channel aid that best preserved the acoustic properties of speech compared to linear amplification would yield the best perceptual results, and that the compression settings that most altered the acoustic properties of speech compared to linear would yield significantly poorer speech perception. On the basis of initial acoustic analysis of the test stimuli recorded through a hearing aid, two different compression amplification settings were chosen for the perceptual study. Participants were 74 adults with mild to moderate sensorineural hearing impairment. Overall, the speech perception results supported the hypothesis. A further aim of the study was to determine if variation in participants' speech perception with compression amplification (compared to linear amplification) could be explained by the individual characteristics of age, degree of loss, dynamic range, temporal resolution, and frequency selectivity; however, no significant relationships were found.
Resumo:
Some results are obtained for non-compact cases in topological vector spaces for the existence problem of solutions for some set-valued variational inequalities with quasi-monotone and lower hemi-continuous operators, and with quasi-semi-monotone and upper hemi-continuous operators. Some applications are given in non-reflexive Banach spaces for these existence problems of solutions and for perturbation problems for these set-valued variational inequalities with quasi-monotone and quasi-semi-monotone operators.
Resumo:
In the paper we present two continuous selection theorems in hyperconvex metric spaces and apply these to study xed point and coincidence point problems as well as variational inequality problems in hyperconvex metric spaces.
Resumo:
This paper considers the question of which is better: the batch or the continuous activated sludge processes? It is an important question because dissension still exists in the wastewater industry as to the relative merits of each of the processes. A review of perceived differences in the processes from the point of view of two related disciplines, process engineering and biotechnology, is presented together with the results of previous comparative studies. These reviews highlight possible areas where more understanding is required. This is provided in the paper by application of the flexibility index to two case studies. The flexibility index is a useful process design tool that measures the ability of the process to cope with long term changes in operation.
Resumo:
Knowledge of differences in voice and speech characteristics between novice and professional broadcasters is essential for effective education of broadcast journalism students. Because newsreaders rely on optimal voice production, information pertaining to vocal hygiene is also important. The first aim of this study was to compare the voice and speech characteristics of professional newsreaders, student newsreaders and control participants. The second aim was to compare the awareness and use of vocal hygiene across these groups. Professional radio newsreaders, broadcast journalism students and two matched control groups were included in the study. Each participant recorded a news bulletin and completed a questionnaire on vocal hygiene. Data analysis of the recording included objective analysis and perceptual ratings by a panel of three judges. Significant student-professional differences were found. Compared to both the students and the control groups, the professional newsreaders had greater variation in speaking fundamental frequency, a faster rate of speech, fewer pronunciation errors and higher perceptual ratings on vocal quality, emphasis, continuity, phrasing and style of newsreading. Female professional newsreaders had a higher speaking fundamental frequency than both their control participants and the student newsreaders. Comparison of vocal hygiene awareness revealed few significant differences between any of the groups.
Resumo:
This paper is situated within a theoretical discussion that asserts a positive correlation between indirectness and politeness, and uses these claims as a springboard for an examination of polite ways of issuing directives in eighteenth century Chinese. On the basis of an analysis of directive speech acts from dialogue in the novel Honglou meng, it argues that the concept of indirectness, as it applies to the illocutionary transparency of individual speech acts, has no particular value in the culture and language of eighteenth century Chinese men. It is found that other linguistic devices such as particles, the reduplication of verbs, terms of address, and the presence and sequencing of supportive moves are far more significant to the communication of politeness. The findings suggest a need to rethink current theoretical positions on this subject and move beyond the analysis of individual speech acts to examine the role discourse structure and management play in the enactment of politeness. (C) 2002 Elsevier Science B.V. All rights reserved.
Resumo:
We investigate nonclassical Stokes-operator variances in continuous-wave polarization-squeezed laser light generated from one and two optical parametric amplifiers. A general expression of how Stokes-operator variances decompose into two-mode quadrature operator variances is given. Stokes parameter variance spectra for four different polarization-squeezed states have been measured and compared with a coherent state. Our measurement results are visualized by three-dimensional Stokes-operator noise volumes mapped on the quantum Poincare sphere. We quantitatively compare the channel capacity of the different continuous-variable polarization states for communication protocols. It is shown that squeezed polarization states provide 33% higher channel capacities than the optimum coherent beam protocol.
Resumo:
We generate a pair of entangled beams from the interference of two amplitude squeezed beams. The entanglement is quantified in terms of EPR paradox and inseparability criteria, with both results clearly beating the standard quantum limit. We experimentally analyze the effect of decoherence on each criterion and demonstrate qualitative differences. We also characterize the number of required and excess photons present in the entangled beams and provide contour plots of the efficacy of quantum information protocols in terms of these variables.
Resumo:
We report the experimental demonstration of quantum teleportation of the quadrature amplitudes of a light field. Our experiment was stably locked for long periods, and was analyzed in terms of fidelity F and with signal transfer T-q=T++T- and noise correlation V-q=Vinparallel to out+Vinparallel to out-. We observed an optimum fidelity of 0.64+/-0.02, T-q=1.06+/-0.02, and V-q=0.96+/-0.10. We discuss the significance of both T-q>1 and V-q
Resumo:
We present the quantum theory of the far-off-resonance continuous-wave Raman laser using the Heisenberg-Langevin approach. We show that the simplified quantum Langevin equations for this system are mathematically identical to those of the nondegenerate optical parametric oscillator in the time domain with the following associations: pump pump, Stokes signal, and Raman coherence idler. We derive analytical results for both the steady-state behavior and the time-dependent noise spectra, using standard linearization procedures. In the semiclassical limit, these results match with previous purely semiclassical treatments, which yield excellent agreement with experimental observations. The analytical time-dependent results predict perfect photon statistics conversion from the pump to the Stokes and nonclassical behavior under certain operational conditions.