999 resultados para contact hour


Relevância:

20.00% 20.00%

Publicador:

Resumo:

This project advances the knowledge of rail wear and crack formation due to rail/wheel contact in Australian heavy-haul railway lines. This comprehensive study utilised numerous techniques including: simulation using a twin-disk test-rig, scanning electron microscope particle analysis and finite element modeling for material failure prediction. Through this work, new material failure models have been developed which may be used to predict the lifetime and reliability of materials undergoing severe contact conditions.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Contrary to what many practitioners believe, current generation contact lenses are easy to fit, are well tolerated, provide superior vision, are physiologically compatible with the anterior ocular structures, cause few serious complications and are cost effective. These factors will be explored with examples of advancements that have occurred in contact lens practice over the past two decades. Consideration will also be given to the role of optometrists, the contact lens industry and educational institutions in promoting contact lenses as an alternative form of vision correction.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose:Multifocal contact lenses (MCLs) have been available for decades. A review of the literature suggests that while, historically, these lenses have been partially successful, they have struggled to compete with monovision (MV). More recent publications suggest that there has been an improvement in the performance of these lenses. This study set out to investigate whether the apparent improved lens performance reported in the literature is reflected in clinical practice. Methods:Data collected over the last 5yrs via the International Contact Lens Prescribing Survey Consortium was reviewed for patients over the age of 45yrs. The published reports of clinical trials were reviewed to assess lens performance over the time period. Results:Data review was of 16,680 presbyopic lens fits in 38 countries. The results are that 29% were fit with MCLs, 8% MV and 63% single vision (SV). A previous survey conducted in Australia during 1988-89 reported that 9% of presbyopes were fit with MCLs, 29% MV and 63% SV. The results from our survey for Australia alone were 28% (MV 13%) vs 9% (MV 29%) suggesting an increase in usage of MCLs from 1988-89 to 2010. A review of the literature indicates the reported level of visual acuities with MCLs in comparison to MV has remained equivalent over this time period, yet preference has switch from MV to MCLs. Conclusions:There is evidence that currently more MCLs than MV are being fit to presbyopes, compared to 1988-89. This increased use is likely due to the improved visual performance of these lenses, which is not demonstrated with acuity measures but reported by wearers, suggesting that patient-based subjective ratings are currently the best way to measure visual performance.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

"Contact Lens Complications has become established as the definitive guide to the ocular response to contact lens wear. In this highly anticipated third edition, award-winning contact lens author, clinician and researcher, Professor Nathan Efron, presents a thoroughly revised and expanded, clinician-friendly account of how to identify, understand and manage contact lens complications in modern-day practice. Professor Efron is renowned for his ability to distil often complex principles of ocular physiology and pathology into an easy-to-read, highly structured format. The subject matter is systematically laid out, with various complications arranged logically by tissue structure - which is the way practitioners naturally approach clinical problems. Beautifully presented and lavishly illustrated with full-colour schematic diagrams and clinical pictures, this book can serve as both a practical chair-side manual and authoritative reference."--publisher website

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Rigid lenses, which were originally made from glass (between 1888 and 1940) and later from polymethyl methacrylate or silicone acrylate materials, are uncomfortable to wear and are now seldom fitted to new patients. Contact lenses became a popular mode of ophthalmic refractive error correction following the discovery of the first hydrogel material – hydroxyethyl methacrylate – by Czech chemist Otto Wichterle in 1960. To satisfy the requirements for ocular biocompatibility, contact lenses must be transparent and optically stable (for clear vision), have a low elastic modulus (for good comfort), have a hydrophilic surface (for good wettability), and be permeable to certain metabolites, especially oxygen, to allow for normal corneal metabolism and respiration during lens wear. A major breakthrough in respect of the last of these requirements was the development of silicone hydrogel soft lenses in 1999 and techniques for making the surface hydrophilic. The vast majority of contact lenses distributed worldwide are mass-produced using cast molding, although spin casting is also used. These advanced mass-production techniques have facilitated the frequent disposal of contact lenses, leading to improvements in ocular health and fewer complications. More than one-third of all soft contact lenses sold today are designed to be discarded daily (i.e., ‘daily disposable’ lenses).

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The deposition of biological material (biofouling) onto polymeric contact lenses is thought to be a major contributor to lens discomfort and hence discontinuation of wear. We describe a method to characterize lipid deposits directly from worn contact lenses utilizing liquid extraction surface analysis coupled to tandem mass spectrometry (LESA-MS/MS). This technique effected facile and reproducible extraction of lipids from the contact lens surfaces and identified lipid molecular species representing all major classes present in human tear film. Our data show that LESA-MS/MS is a rapid and comprehensive technique for the characterization of lipid-related biofouling on polymer surfaces.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The insulated rail joint (IRJ) is an essential component in a track circuit that controls the signaling system. Failure of IRJs leads to improper functioning of the signals,with potential for catastrophic results. Therefore, IRJs are regarded as safety-critical sections of rail network; hence, all of their components must be maintained in pristine design condition.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The 48 hour game making challenge has been running since 2007. In recent years, we have not only been running a 'game jam' for the local community but we have also been exploring the way in which the event itself and the place of the event has the potential to create its own stories. The 2014 challenge is part of a series of data collection opportunities focussed on the game jam itself and the meaning making that the participants engage in about the event. We continued the data collection commenced in 2012: "Game jams are the creative festivals of the game development community and a game jam is very much an event or performance; its stories are those of subjective experience. Participants return year after year and recount personal stories from previous challenges; arrival in the 48hr location typically inspires instances of individual memory and narration more in keeping with those of a music festival or an oft frequented holiday destination. Since its inception, the 48hr has been heavily documented, from the photo-blogging of our first jam and the twitter streams of more recent events to more formal interviews and documentaries (see Anderson, 2012). We have even had our own moments of Gonzo journalism with an on-site press room one year and an ‘embedded’ journalist another year (Keogh, 2011). In the last two years of the 48hr we have started to explore ways and means to collect more abstract data during the event, that is, empirical data about movement and activity. The intent behind this form of data collection was to explore graphic and computer generated visualisations of the event, not for the purpose of formal analysis but in the service of further story telling." [exerpt from truna aka j.turner, Thomas & Owen, 2013) See: truna aka j.turner, Thomas & Owen (2013) Living the indie life: mapping creative teams in a 48 hour game jam and playing with data, Proceedings of the 9th Australasian Conference on Interactive Entertainment, IE'2013, September 30 - October 01 2013, Melbourne, VIC, Australia

Relevância:

20.00% 20.00%

Publicador:

Resumo:

New technologies for examination of the anterior eye in contact lens practice don’t appear to have taken a huge leap in the past decade however there a several novel adaptations of existing technology worthy of note. In other areas of health we have self-diagnosis via smartphone or other gadgets adapted as medical devices. In practice and research in vitro and in vivo new adaptive technologies have expanded our capabilities in assessing the anterior eye, in particular corneal and conjunctival confocal microscopy.