946 resultados para comparison of the member countries
Resumo:
To test the hypothesis that 3,5,3'-triiodothyroacetic acid (Triac) is more active as a TSH suppressor than on peripheral parameters of thyroid hormone action, the following parameters were studied: basal metabolic rate, sleeping energy expenditure (SEE), sex hormone-binding globulin, and cholesterol. In a double blind trial, 14 subjects received during 3 weeks (phase 1) 180 micrograms T4 or 1700 micrograms Triac daily, divided into 3 doses, to suppress thyroidal secretion. The dosage was doubled for the next 3 weeks (phase 2). Under T4 treatment, TSH reached 0.11 mU/L during phase 1 and less than 0.03 mU/L during phase 2. With Triac, a marked TSH inhibition occurred after 1 week (0.17 mU/L), followed by an escape during the following 2 weeks (0.63 mU/L). During phase 2, an almost complete TSH suppression was obtained (0.03 mU/L). Both Triac doses suppressed endogenous thyroid hormone secretion, as evidenced by T4 and rT3 levels. Both substances induced a 2-fold stimulation of sex hormone-binding globulin during phase 2. Serum cholesterol decreased similarly, without affecting the high/low density lipoprotein ratio. T4 increased SEE by 4.1% and 8.5% during phases 1 and 2. Triac failed to induce the expected peripheral metabolic responses of the thyroid hormones, as demonstrated by an unchanged SEE and basal metabolic rate. These results clearly show a preferential action of Triac on TSH suppression.
Resumo:
A Comparison of the Management Models of Protected Areas between China and the African South Region allows reading and evaluating the similarities and differences in the use of management model as a management tool for protected areas in China and South African Region. Specifically, some positive and negative features of the management approaches for the two regions. Secondary data was collected from various related literature such as policy documents, students‟ dissertations/thesis, scientific articles and magazines. Based on the method above, the study found out that China's first nature reserve was the Dingus Mountain Nature Reserve in Zhaoqing, Guangdong province established in 1956. By the end of 2005, about 2,349 nature reserves of various kinds were set up throughout the country, covering a total area of 149.95 million ha and accounting for 15 percent of the total land territory. The study further found that Southern Africa has approximately 4,390 protected areas out of 11487920 total land areas and Eastern Africa has approximately 1838144 protected areas, which is equivalent to 15.0% of the total land areas. South Africa in this region had its first declared natural park in 1926 after Paul Kruger (a war hero) had alerted the authorities of the extinguishing threat of some animal species of region.
Resumo:
Introduction: The original and modified Wells score are widely used prediction rules for pre-test probability assessment of deep vein thrombosis (DVT). The objective of this study was to compare the predictive performance of both Wells scores in unselected patients with clinical suspicion of DVT.Methods: Consecutive inpatients and outpatients with a clinical suspicion of DVT were prospectively enrolled. Pre-test DVT probability (low/intermediate/high) was determined using both scores. Patients with a non-high probability based on the original Wells score underwent D-dimers measurement. Patients with D-dimers <500 mu g/L did not undergo further testing, and treatment was withheld. All others underwent complete lower limb compression ultrasound, and those diagnosed with DVT were anticoagulated. The primary study outcome was objectively confirmed symptomatic venous thromboembolism within 3 months of enrollment.Results: 298 patients with suspected DVT were included. Of these, 82 (27.5%) had DVT, and 46 of them were proximal. Compared to the modified score, the original Wells score classified a higher proportion of patients as low-risk (53 vs 48%; p<0.01) and a lower proportion as high-risk (17 vs 15%; p=0.02); the prevalence of proximal DVT in each category was similar with both scores (7-8% low, 16-19% intermediate, 36-37% high). The area under the receiver operating characteristic curve regarding proximal DVT detection was similar for both scores, but they both performed poorly in predicting isolated distal DVT and DVT in inpatients.Conclusion: The study demonstrates that both Wells scores perform equally well in proximal DVT pre-test probability prediction. Neither score appears to be particularly useful in hospitalized patients and those with isolated distal DVT. (C) 2011 Elsevier Ltd. All rights reserved.
Resumo:
Given the adverse impact of image noise on the perception of important clinical details in digital mammography, routine quality control measurements should include an evaluation of noise. The European Guidelines, for example, employ a second-order polynomial fit of pixel variance as a function of detector air kerma (DAK) to decompose noise into quantum, electronic and fixed pattern (FP) components and assess the DAK range where quantum noise dominates. This work examines the robustness of the polynomial method against an explicit noise decomposition method. The two methods were applied to variance and noise power spectrum (NPS) data from six digital mammography units. Twenty homogeneously exposed images were acquired with PMMA blocks for target DAKs ranging from 6.25 to 1600 µGy. Both methods were explored for the effects of data weighting and squared fit coefficients during the curve fitting, the influence of the additional filter material (2 mm Al versus 40 mm PMMA) and noise de-trending. Finally, spatial stationarity of noise was assessed.Data weighting improved noise model fitting over large DAK ranges, especially at low detector exposures. The polynomial and explicit decompositions generally agreed for quantum and electronic noise but FP noise fraction was consistently underestimated by the polynomial method. Noise decomposition as a function of position in the image showed limited noise stationarity, especially for FP noise; thus the position of the region of interest (ROI) used for noise decomposition may influence fractional noise composition. The ROI area and position used in the Guidelines offer an acceptable estimation of noise components. While there are limitations to the polynomial model, when used with care and with appropriate data weighting, the method offers a simple and robust means of examining the detector noise components as a function of detector exposure.
Resumo:
The most widely used formula for estimating glomerular filtration rate (eGFR) in children is the Schwartz formula. It was revised in 2009 using iohexol clearances with measured GFR (mGFR) ranging between 15 and 75 ml/min × 1.73 m(2). Here we assessed the accuracy of the Schwartz formula using the inulin clearance (iGFR) method to evaluate its accuracy for children with less renal impairment comparing 551 iGFRs of 392 children with their Schwartz eGFRs. Serum creatinine was measured using the compensated Jaffe method. In order to find the best relationship between iGFR and eGFR, a linear quadratic regression model was fitted and a more accurate formula was derived. This quadratic formula was: 0.68 × (Height (cm)/serum creatinine (mg/dl))-0.0008 × (height (cm)/serum creatinine (mg/dl))(2)+0.48 × age (years)-(21.53 in males or 25.68 in females). This formula was validated using a split-half cross-validation technique and also externally validated with a new cohort of 127 children. Results show that the Schwartz formula is accurate until a height (Ht)/serum creatinine value of 251, corresponding to an iGFR of 103 ml/min × 1.73 m(2), but significantly unreliable for higher values. For an accuracy of 20 percent, the quadratic formula was significantly better than the Schwartz formula for all patients and for patients with a Ht/serum creatinine of 251 or greater. Thus, the new quadratic formula could replace the revised Schwartz formula, which is accurate for children with moderate renal failure but not for those with less renal impairment or hyperfiltration.
Resumo:
BACKGROUND: Protein-energy malnutrition is highly prevalent in aged populations. Associated clinical, economic, and social burden is important. A valid screening method that would be robust and precise, but also easy, simple, and rapid to apply, is essential for adequate therapeutic management. OBJECTIVES: To compare the interobserver variability of 2 methods measuring food intake: semiquantitative visual estimations made by nurses versus calorie measurements performed by dieticians on the basis of standardized color digital photographs of servings before and after consumption. DESIGN: Observational monocentric pilot study. SETTING/PARTICIPANTS: A geriatric ward. The meals were randomly chosen from the meal tray. The choice was anonymous with respect to the patients who consumed them. MEASUREMENTS: The test method consisted of the estimation of calorie consumption by dieticians on the basis of standardized color digital photographs of servings before and after consumption. The reference method was based on direct visual estimations of the meals by nurses. Food intake was expressed in the form of a percentage of the serving consumed and calorie intake was then calculated by a dietician based on these percentages. The methods were applied with no previous training of the observers. Analysis of variance was performed to compare their interobserver variability. RESULTS: Of 15 meals consumed and initially examined, 6 were assessed with each method. Servings not consumed at all (0% consumption) or entirely consumed by the patient (100% consumption) were not included in the analysis so as to avoid systematic error. The digital photography method showed higher interobserver variability in calorie intake estimations. The difference between the compared methods was statistically significant (P < .03). CONCLUSIONS: Calorie intake measures for geriatric patients are more concordant when estimated in a semiquantitative way. Digital photography for food intake estimation without previous specific training of dieticians should not be considered as a reference method in geriatric settings, as it shows no advantages in terms of interobserver variability.
Resumo:
Landfill gas emissions are one of the main sources of anthropogenic methane (CH4), a major greenhouse gas. In this paper, an economically attractive alternative to minimize greenhouse gas emissions from municipal solid waste landfills was sought. This alternative consists in special biofilters as landfill covers with oxidative capacity in the presence of CH4. To improve the quality/cost ratio of the project, compost was chosen as one of the cover substrates and soil (Typic red yellow-silt-clay Podzolic) as the other. The performance of four substrates was studied in laboratory experiments: municipal solid waste (MSW) compost, soil, and two soil-compost at different proportions. This study aimed to evaluate the suitability and environmental compatibility as a means of CH4 oxidation in biofilters. Four biofilters were constructed in 60 cm PVC tubes with an internal diameter of 10 cm. Each filter contained 2.3 L of oxidizing substrate at the beginning of the experiment. The gas used was a mixture of CH4 and air introduced at the bottom of each biofilter, at a flow of 150 mL min-1, by a flow meter. One hundred days after the beginning of the experiment, the best biofilter was the MSW compost with an oxidation rate of 990 g m-3 day-1 , corresponding to an efficiency of 44 %. It can be concluded that the four substrates studied have satisfactory oxidative capacity, and the substrates can be used advantageously as cover substrate of MSW landfills.
Resumo:
The accuracy of peritoneoscopy and liver biopsy in the diagnosis of hepatic cirrhosis was compared in 473 consecutive patients submitted to both procedures. One hundred and fifty-two of them had cirrhosis diagnosed by one or both methods. There was 73% agreement between the two procedures. `Apparent' false-negative results were 17·7% for peritoneoscopy and 9·3% for liver biopsy. The incidence of false-negative results in the diagnosis of cirrhosis can be reduced by combining both procedures.
Resumo:
Document Type: Meeting Abstract
Resumo:
This work compares the detector performance and image quality of the new Kodak Min-R EV mammography screen-film system with the Fuji CR Profect detector and with other current mammography screen-film systems from Agfa, Fuji and Kodak. Basic image quality parameters (MTF, NPS, NEQ and DQE) were evaluated for a 28 kV Mo/Mo (HVL = 0.646 mm Al) beam using different mAs exposure settings. Compared with other screen-film systems, the new Kodak Min-R EV detector has the highest contrast and a low intrinsic noise level, giving better NEQ and DQE results, especially at high optical density. Thus, the properties of the new mammography film approach those of a fine mammography detector, especially at low frequency range. Screen-film systems provide the best resolution. The presampling MTF of the digital detector has a value of 15% at the Nyquist frequency and, due to the spread size of the laser beam, the use of a smaller pixel size would not permit a significant improvement of the detector resolution. The dual collection reading technology increases significantly the low frequency DQE of the Fuji CR system that can at present compete with the most efficient mammography screen-film systems.
Resumo:
Dissociated cerebral hemisphere cells from 4- to 7-day-old chick embryos were cultured either on a collagen or a polylysine substrate in a serum-containing medium. Neurons were characterized by the demonstration of acetylcholinesterase, the presence of D2/N-CAM glycoprotein and neurofilament proteins. The proliferation of neuronal precursor cells was shown by morphological observations, autoradiographic analysis and measurements of [3H]-thymidine incorporation. Neuronal precursors derived from the 6-day-old embryos showed the highest proliferative activity. Neuroblast proliferation was found to be dependent on the culture substrates (i.e. polylysine or collagen), which yielded either isolated cells or cell aggregates, and the latter favored the mitogenic effect.